Emerson Network Power LPS63 Universal input Datasheet

Embedded Power for
Business-Critical Continuity
Rev. 07.23.07
LPS60-M Series
1 of 3
LPS60-M Series
60 Watts
RoHS
Medical
Total Power:
Input Voltage:
# of Outputs:
60 - 80 Watts
85 - 264 VAC
120 - 300VDC
Single
Electrical Specifications
Special Features
•
•
•
•
•
•
•
•
•
•
Medical safety approvals
Universal input
3" x 5" footprint
Remote sense
Built in EMI filter
Low output ripple
Adjustable output voltage
Overload protection
110 KHz switching frequency
LPX60 enclosure kit available
Input
Input range
85 - 264 VAC (wide range)
120 - 300VDC
Frequency
47-440 Hz
Inrush current
Input current
<18A peak @ 115VAC, <36A peak @230 VAC,
cold start @ 25°C
1.5A max. (RMS) @ 115 VAC
Efficiency
70% typical at full load
EMI filter
FCC Class A conducted; CISPR22 Class A conducted;
EN55022 Class A conducted; VDE0878 PT3 Class A conducted
Safety ground leakage
current
<75μA @ 50/60Hz; 264VAC input
Output
Maximum power
Adjustment range
60W for convection; 80W with 30CFM forced air
-5, +10% minimum
Hold-up time
20ms @ 60W load, 115VAC nominal line
Overload protection
Safety
VDE
UL
CSA
CE
0750/EN60950 (IEC601)
21310-3336-0015
UL2601
E182560
CSA 22.2 No.601.1
LR109492
Mark (LVD)
Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating
Overvoltage protection 5V output; 5.7 - 6.7VDC. Other outputs 10% to 25%
above nominal output
Remote sense
Compensates for 0.5V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
Rev. 07.23.07
LPS60-M Series
2 of 3
Environmental Specifications
Operating temperature: 0° to 50°C ambient derate each output as 2.5%
per degree from 50° to 70°C, -20°C startup
Storage temperature:
-40°C to +85°C
Electromagnetic
susceptibility:
Humidity:
Power Derating Curve
80W
30 CFM Forced Air Cooling
designed to meet IEC801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95% RH
Vibration:
Three orthogonal axes, sweep at 1cot/min, 5 min.
dwell at four major resonances 0.75G peak 5Hz to
500Hz, operational
Temperature coefficient ±0.04% per °C
MTBF demonstrated
>550,000 hours at full load and 25°C ambient
conditions
Output
Power
(Watts)
60W
40W
Natural
Convection
Cooling
20W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
0.22"
(5.6)
M2
GND
SK201
3.00"
(76.2)
1
2
3
4
5
6
2.55"
(64.8)
SK 1
1
N
3
L
4.56"
(115.8)
0.22"
(5.6)
1.69"
(42.9)
0.12"
(3)
_+
Remote Sense
Connector
Voltage
Adj. Pot
SK 2
0.15" (4)
DIA (4 places)
5.00"
(127)
30W
0W
Mechanical Drawing
M1
40W
Embedded Power for
Business-Critical Continuity
Ordering Information
Americas
LPS63-M
12V
0A
5A
6.7A
7.5A
±2%
120mV
LPS64-M
15V
0A
4A
5.3A
6A
±2%
150mV
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
LPS65-M
24V
0A
2.5A
3.3A
3.8A
±2%
240mV
Europe (UK)
Model
Number
Maximum Load
Minimum
with Convection
Load
Cooling
Output
Voltage
Maximum Load
with 30CFM
forced Air
Peak
Regulation2
Load1
Ripple
P/P (PARD)3
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10μF (tantalum capacitor) in parallel with a 0. μF capacitor at rated
line voltage and load ranges.
Rev. 07.23.07
LPS60-M Series
3 of 3
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
Pin Assignments
Connector LPS62-M
LPS63-M
LPS65-M
SK1-1
SK1-3
Neutral
Line
Neutral
Line
Neutral
Line
SK2-1
SK2- 2
SK2- 3
SK2-4
SK2-5
SK2-6
SK201-1
SK201-2
+12V
+12V
+12V
Common
Common
Common
+Sense
-Sense
+15V
+15V
+15V
Common
Common
Common
+Sense
-Sense
+24
+24
+24
Common
Common
Common
+Sense
-Sense
Mating Connectors
AC Input:
DC Outputs:
Molex 09-50-8031 (USA) Not required for (-T) option
09-91-0300 (UK)
PINS: 08-58-0111
Molex 09-50-8061 (USA) Not required for (-T) option
09-91-0600 (UK)
PINS: 08-52-0113
Remote Sense: Molex 22-01-2025
PINS: 08-52-0113
Astec Connector Kit #70-841-006, includes all of the above
1.
2.
Specifications subject to change without notice.
All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm)
3.
4.
5.
Mounting holes M1 and M2 should be grounded for EMI purposes.
Mounting hole M1 is safety ground connection.
Specifications are for convection rating at factory settings at 115 VAC input,
25°C unless otherwise stated.
6.
7.
Warranty: 2 year
Weight: 0.75lbs/0.34kg
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.astecpower.com
www.artesyn.com
[email protected]
[email protected]
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Similar pages