LEM LT4000-S Current transducer lt 4000- Datasheet

Current Transducer LT 4000-S
IPN
=
4000 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
with ± 24 V
ISN
KN
VC
IC
Vd
@ ± 4000 A max
@ ± 6000 A max
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
4000
0 .. ± 6000
R M min
R M max
0
0
10
2
A
A
Ω
Ω
800
mA
1 : 5000
± 24
V
35 (@ ± 24 V) + IS mA
6
kV
Accuracy - Dynamic performance data
XG
ε
Overall accuracy @ IPN , TA = 25°C
Linearity
L
± 0.5
< 0.1
Typ
%
%
Max
± 0.8
± 0.8
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
- 25°C .. + 70°C
± 0.6
tr
di/dt
f
Response time 1) @ 90 % of IP max
di/dt accurately followed
Frequency bandwidth (- 1 dB)
<1
> 50
DC .. 100
mA
mA
µs
A/µs
kHz
Notes :
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 70°C
Mass
Standards 2)
1)
2)
•Closed loop (compensated) current
transducer using the Hall effect
•Insulated plastic case recognized
according to UL 94-V0.
Advantages
•Excellent accuracy
•Very good linearity
•Low temperature drift
•Optimized response time
•Wide frequency bandwidth
•No insertion losses
•High immunity to external
interference
•Current overload capability.
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives
•Battery supplied applications
•Uninterruptible Power Supplies
General data
TA
TS
RS
m
Features
- 25 .. + 70
- 40 .. + 85
15
6
EN 50178
°C
°C
Ω
kg
(UPS)
•Switched Mode Power Supplies
(SMPS)
•Power supplies for welding
applications.
With a di/dt of 100 A/µs
A list of corresponding tests is available
980728/8
LEM Components
w w w .lem.com
Dimensions LT 4000-S
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Secondary terminals
Terminal + : supply voltage + 24 V
Terminal M : measure
Terminal - : supply voltage - 24 V
Connection
Top view
Mechanical characteristics
•General tolerance
•Fastening
•Primary through-hole
•Connection of secondary
fastening torque
Remarks
± 1.0 mm
4 holes ∅ 10.5 mm
∅ 102 mm
M5 threaded studs
2.2 Nm
•IS is positive when IP flows in the direction of the arrow.
•Temperature of the primary conductor should not exceed
100°C.
•Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.