LEM LT505-S Current transducer lt 505- Datasheet

Current Transducer LT 505-S
IPN
=
500 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance @
with ± 15 V
with ± 24 V
ISN
KN
VC
IC
Vd
Vb
@ ± 500
@ ± 800
@ ± 500
@ ± 1200
500
0 .. ± 1200
TA = 70°C
TA = 85°C
RM min RM max RM min RM max
A max
A max
A max
A max
0
0
0
0
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
R.m.s. rated voltage 1), safe separation
basic isolation
65
15
145
22
0
0
15
15
60
12
140
18
A
A
Features
•Closed loop (compensated) current
transducer using the Hall effect
Ω
Ω
Ω
Ω
100
mA
1 : 5000
± 15 .. 24
V
30 (@ ± 24 V) + IS mA
6
kV
1750
V
3500
V
•Insulated plastic case recognized
according to UL 94-V0.
Advantages
•Excellent accuracy
•Very good linearity
•Low temperature drift
•Optimized response time
•Wide frequency bandwidth
•No insertion losses
•High immunity to external
interference
•Current overload capability.
Accuracy - Dynamic performance data
XG
ε
Overall accuracy @ IPN , TA = 25°C
Linearity
L
± 0.6
< 0.1
Typ
%
%
Max
± 0.4
± 0.5
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
- 10°C .. + 85°C
± 0.3
tr
di/dt
f
Response time 2) @ 90 % of IP max
di/dt accurately followed
Frequency bandwidth (- 1 dB)
<1
> 50
DC .. 150
mA
mA
µs
A/µs
kHz
Applications
•AC variable speed drives and servo
motor drives
•Static converters for DC motor drives
•Battery supplied applications
•Uninterruptible Power Supplies
(UPS)
•Switched Mode Power Supplies
General data
TA
TS
RS
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
m
Mass
Standards 3)
Notes :
1)
2)
3)
(SMPS)
TA = 70°C
TA = 85°C
- 10 .. + 85
- 25 .. + 100
65
69
400
EN 50178
Pollution class 2. With a non insulated primary bar which fills the
through-hole
With a di/dt of 100 A/µs
A list of corresponding tests is available
LEM Components
°C
°C
Ω
Ω
g
•Power supplies for welding
applications.
980708/6
w w w .lem.com
Dimensions LT 505-S
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Secondary terminals
Terminal + : supply voltage + 15 .. 24 V
Terminal M : measure
Terminal - : supply voltage - 15 .. 24 V
Connection
Top view
Mechanical characteristics
•General tolerance
•Fastening
•Primary through-hole
•Connection of secondary
Remarks
± 0.5 mm
4 holes ∅ 6.5 mm
40.5 x 40.5 mm
Faston 6.3 x 0.8 mm
•IS is positive when IP flows in the direction of the arrow.
•Temperature of the primary conductor should not exceed
100°C.
•Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Similar pages