LITEON LTL2G3VEK Property of lite-on only Datasheet

LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
Features
* High luminous intensity output.
* Low power consumption.
* High efficiency.
* Versatile mounting on P.C. board or panel.
* I.C. Compatible/low current requirements.
* Popular T-13/4 diameter.
Package
Dimensions
Part No.
LTL2G3VEK
Lens
Water
Clear
Source Color
AlInGaP Red
Notes:
1. All dimensions are in millimeters (inches).
2. Tolerance is ±0.25mm(.010") unless otherwise noted.
3. Protruded resin under flange is 1.0mm(.04") max.
4. Lead spacing is measured where the leads emerge from the package.
5. Specifications are subject to change without notice.
Part
No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
1
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
Absolute Maximum Ratings at TA=25℃
Parameter
Power Dissipation
Peak Forward Current
(1/10 Duty Cycle, 0.1ms Pulse Width)
DC Forward Current
Derating Linear From 40℃
Reverse Voltage
Maximum Rating
Unit
120
mW
130
mA
50
mA
0.75
mA/℃
5
V
Operating Temperature Range
-40℃ to + 80℃
Storage Temperature Range
-55℃ to + 100℃
Lead Soldering Temperature
[1.6mm(.063") From Body]
Part
No. : LTL2G3VEK
BNS-OD-C131/A4
260℃ for 5 Seconds
Page :
2
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
Electrical / Optical Characteristics at TA=25℃
Parameter
Symbol
Min.
Typ.
IV
1900
3500
mcd
2θ1/2
20
deg
Peak Emission Wavelength
λP
632
nm
Dominant Wavelength
λd
624
nm
Spectral Line Half-Width
∆λ
20
nm
Forward Voltage
VF
2.0
Reverse Current
IR
Luminous Intensity
Viewing Angle
Max.
Unit
Test Condition
IF = 20mA
Note 1
Note 2 (Fig.5)
Measurement
@Peak (Fig.1)
Note 4
2.5
V
IF = 20mA
100
µA
VR = 5V
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
4. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
Part
No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
3
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
Typical
(25℃
Part
No. : LTL2G3VEK
BNS-OD-C131/A4
Electrical
Ambient
/
Optical
Temperature
Characteristics
Unless
Otherwise
Curves
Noted)
Page :
4
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
Packing Spec
1000, 500 or 250 pcs per packing bag
8 packing bags per inner carton
total 8000 pcs per inner carton
8 Inner cartons per outer carton
total 64000 pcs per outer carton
In every shipping lot, only the last pack will be non-full packing
Part
No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
5
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
Bin Code List
For Reference
Luminous Intensity
Unit : mcd @20mA
Bin Code
Min.
Max.
S
1900
2500
T
2500
3200
U
3200
4200
V
4200
5500
W
5500
7200
Note: Tolerance of each bin limit is ±15%
Dominant Wavelength
Unit : nm @20mA
Bin Code
Min.
Max.
H27
613.5
617.0
H28
617.0
621.0
H29
621.0
625.0
H30
625.0
629.0
H31
629.0
633.0
Note: Tolerance of each bin limit is ±1nm
Part
No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
6
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
CAUTIONS
1. Application
The LEDs described here are intended to be used for ordinary electronic equipment (such as office equipment,
communication equipment and household applications).Consult Liteon’s Sales in advance for information on
applications in which exceptional reliability is required, particularly when the failure or malfunction of the
LEDs may directly jeopardize life or health (such as in aviation, transportation, traffic control equipment,
medical and life support systems and safety devices).
2. Storage
The storage ambient for the LEDs should not exceed 30°C temperature or 70% relative humidity.
It is recommended that LEDs out of their original packaging are used within three months.
For extended storage out of their original packaging, it is recommended that the LEDs be stored in
a sealed container with appropriate desiccant or in desiccators with nitrogen ambient.
3. Cleaning
Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LEDs if necessary.
4. Lead Forming & Assembly
During lead forming, the leads should be bent at a point at least 3mm from the base of LED lens.
Do not use the base of the lead frame as a fulcrum during forming.
Lead forming must be done before soldering, at normal temperature.
During assembly on PCB, use minimum clinch force possible to avoid excessive mechanical stress.
5. Soldering
When soldering, leave a minimum of 2mm clearance from the base of the lens to the soldering point.
Dipping the lens into the solder must be avoided.
Do not apply any external stress to the lead frame during soldering while the LED is at high temperature.
Recommended soldering conditions :
Soldering iron
Temperature
Soldering time
300°C Max.
3 sec. Max.
(one time only)
Wave soldering
Pre-heat
Pre-heat time
Solder wave
Soldering time
100°C Max.
60 sec. Max.
260°C Max.
10 sec. Max.
Note: Excessive soldering temperature and/or time might result in deformation of the LED lens or catastrophic
failure of the LED. IR reflow is not suitable process for through hole type LED lamp product.
Part No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
7
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
6. Drive Method
An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs
connected in parallel in an application, it is recommended that a current limiting resistor be incorporated
in the drive circuit, in series with each LED as shown in Circuit A below.
Circuit model A
LED
Circuit model B
LED
(A) Recommended circuit
(B) The brightness of each LED might appear different due to the differences in the I-V characteristics
of those
LEDs
7. ESD (Electrostatic Discharge)
Static Electricity or power surge will damage the LED.
Suggestions to prevent ESD damage:
„ Use a conductive wrist band or anti- electrostatic glove when handling these LEDs
„ All devices, equipment, and machinery must be properly grounded
„ Work tables, storage racks, etc. should be properly grounded
„ Use ion blower to neutralize the static charge which might have built up on surface of the LEDs
plastic lens as a result of friction between LEDs during storage and handing
Part No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
8
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
Suggested checking list :
Training and Certification
1. Everyone working in a static-safe area is ESD-certified?
2. Training records kept and re-certification dates monitored?
Static-Safe Workstation & Work Areas
1. Static-safe workstation or work-areas have ESD signs?
2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V?
3. All ionizer activated, positioned towards the units?
4. Each work surface mats grounding is good?
Personnel Grounding
1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or
conductive shoes with conductive flooring?
2. If conductive footwear used, conductive flooring also present where operator stand or walk?
3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*?
4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs?
5. All wrist strap or heel strap checkers calibration up to date?
Note: *50V for Blue LED.
Device Handling
1. Every ESDS items identified by EIA-471 labels on item or packaging?
2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe
workstation?
3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items?
4. All flexible conductive and dissipative package materials inspected before reuse or recycle?
Others
1. Audit result reported to entity ESD control coordinator?
2. Corrective action from previous audits completed?
3. Are audit records complete and on file?
Part No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
9
of
10
LITE-ON
TECHNOLOGY
CORPORATION
Property of Lite-On Only
8. Reliability Test
Classification
Test
Item
Operation Life
High Temperature
High Humidity
Storage
Endurance
Test
Environmental
Test
High Temperature
High Humidity
Reverse BIAS
Test
Condition
Reference
Standard
Ta= Under Room Temperature As
Per Data Sheet Maximum Rating
*Test Time= 1000HRS (-24HRS,+72HRS)
MIL-STD-750D:1026 (1995)
MIL-STD-883D:1005 (1991)
JIS C 7021:B-1 (1982)
Ta= 65±5℃
RH= 90 ~ 95%
MIL-STD-202F: 103B(1980)
JIS C 7021 : B-11(1982)
Test Time= 240HRS±2HRS
Ta= 65±5℃
RH= 90 ~ 95%
VR=5V
Test Time = 500HRS (-24HRS, +48HRS)
JIS C 7021 : B-11(1982)
High Temperature
Storage
Ta= 105±5℃
*Test Time= 1000HRS (-24HRS,+72HRS)
MIL-STD-883D:1008 (1991)
JIS C 7021:B-10 (1982)
Low Temperature
Storage
Ta= -55±5℃
*Test Time=1000HRS (-24HRS,+72HRS)
JIS C 7021:B-12 (1982)
Temperature
Cycling
105℃ ~ 25℃ ~ -55℃ ~ 25℃
30mins
5mins
30mins 5mins
10 Cycles
MIL-STD-202F:107D (1980)
MIL-STD-750D:1051(1995)
MIL-STD-883D:1010 (1991)
JIS C 7021: A-4(1982)
Thermal
Shock
105 ± 5℃ ~ -55℃ ± 5℃
10mins
10mins
10 Cycles
MIL-STD-202F:107D(1980)
MIL-STD-750D:1051(1995)
MIL-STD-883D:1011 (1991)
Solder
Resistance
T.sol = 260 ± 5℃
Dwell Time= 10 ± 1secs
MIL-STD-202F:210A(1980)
MIL-STD-750D:2031(1995)
JIS C 7021: A-1(1982)
Solderability
T. sol = 230 ± 5℃
Dwell Time= 5 ± 1secs
MIL-STD-202F:208D(1980)
MIL-STD-750D:2026(1995)
MIL-STD-883D:2003(1991)
JIS C 7021: A-2(1982)
9. Others
The appearance and specifications of the product may be modified for improvement, without prior notice.
Part No. : LTL2G3VEK
BNS-OD-C131/A4
Page :
10
of
10
Similar pages