Omron LY2S General purpose relay Datasheet

General Purpose Relay
■
■
■
■
■
LY
Arc barrier equipped
High dielectric strength (2,000 VAC)
Long dependable service life assured
by AgCdO contacts
Choose models with single or
bifurcated contacts, LED indicator,
diode surge suppression, push-to-test
button, or RC circuit
All models meet UL and CSA
approvals; VDE, LR, and SEV
approved versions are available
DVE
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., LY1-DC6).
Type
Standard
Terminal
Plug-in/solder
PCB
LED indicator
Diode surge
suppression
LED indicator
and diode surge
suppression
RC circuit
LED indicator
and RC circuit
Plug-in/solder
Contact
form
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
4PDT
SPDT
DPDT
SPDT
DPDT
Part number
Single contact
Standard
Upper
bracket
mounting
mounting
bracket
LY1
LY1F
LY2
LY2F
LY3
LY3F
LY4
LY4F
LY1-0
—
LY2-0
—
LY3-0
—
LY4-0
—
LY1N
—
LY2N
—
LY3N
—
LY4N
—
LY1-D
—
LY2-D
—
LY3-D
—
LY4-D
—
LY1N-D2
—
LY2N-D2
—
LY4N-D2
—
LY1-CR
—
LY2-CR
—
LY1N-CR
—
LY2N-CR
—
Lower
mounting
bracket
LY1S
LY2S
LY3S
LY4S
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bifurcated contact
Standard
Upper
bracket
mounting
mounting
bracket
—
—
LY2Z
LY2ZF
—
—
—
—
—
—
LY2Z-0
—
—
—
—
—
—
—
LY2ZN
—
—
—
—
—
—
—
LY2Z-D
—
—
—
—
—
—
—
LY2ZN-D2 —
—
—
—
—
LY2Z-CR
—
—
—
LY2ZN-CR —
Note: 1. Types with specifications other than those listed are available. Contact your OMRON Sales representative.
2. To order connecting sockets and mounting tracks, see “Accessories” section.
Lower
mounting
bracket
—
LY2ZS
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
LY
LY
Ordering Information, continued
Type
Push-to-test
button
Terminal
Plug-in/solder
LED indicator and Plug-in/solder
push-to-test button
Contact
form
SPDT
DPDT
3PDT
4PDT
DPDT
4PDT
Part number
Single contact
Standard
Upper
bracket
mounting
mounting
bracket
LY1l4
—
LY2l4
—
LY3l4
—
LY4l4
—
LY2l4N
—
LY4l4N
—
Lower
mounting
bracket
—
—
—
—
—
—
Bifurcated contact
Standard
Upper
bracket
mounting
mounting
bracket
—
—
LY2Zl2
—
—
—
—
—
LY2Zl2N
—
—
—
Lower
mounting
bracket
—
—
—
—
—
—
Note: 1. Types with specifications other than those listed are available. Contact your OMRON Sales representative.
2. To order connecting sockets and mounting tracks, see “Accessories” section.
■ ACCESSORIES
Connecting Sockets
To Order: Select the appropriate part numbers for sockets, clips, and mounting tracks (if required) from the following charts.
Track mounted sockets
Relay
SPDT
DPDT
3PDT
4PDT
Socket*
PTF08A-E
Relay hold-down clip
Standard
PYC-A1
RC circuit
Y92H-3
Mounting track
PFP-100N/PFP-50N &
PFP-M or PFP-100N2
PFP-S (Option spacer)
PTF11A
PTF14A-E
* Track mounted socket can be used as a front connecting socket.
Back connecting sockets
Relay
SPDT
DPDT
3PDT
4PDT
Solder
terminal
socket
PT08
Wire wrap
Relay hold-down clip
terminal
socket
Standard
Push-to-test RC circuit
PT08QN PYC-P
PYC-P2
PYC-1
PT11
PT14
PT11QN
PT14QN
Socket Mounting Plate
Mtg. plate
PYC-S
1
PYP-1
10
–
12
–
18
PYP-18
PTP-1-3
PTP-1
–
PTP-10
PTP-12
–
–
–
Note: Types PYP-18, PTP-12 and PTP-10 may be cut to any desired length.
Relay
SPDT
DPDT
3PDT
4PDT
2
PC terminal socket
PT08-0
PT11-0
PT14-0
Relay hold-down clip
Standard
PYC-P
Push-to-test
PYC-P2
RC circuit
PYC-1
LY
LY
Specifications
■ CONTACT DATA
Single contact
SPDT
Resistive load
(p.f. = 1)
Load
Rated load
Contact material
Carry current
Max. operating
voltage
Max. operating
current
Max. switching
capacity
Min. permissible
load
15 A at 110 VAC
15 A at 24 VDC
AgCdO
15 A
250 VAC
125 VDC
15 A
1,700 VA
360 W
100 mA, 5 VDC
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
10 A at 110 VAC
7 A at 24 VDC
1,100 VA
170 W
DPDT, 3PDT, 4PDT
Resistive load
Inductive load
(p.f. = 1)
(p.f. = 0.4)
(L/R = 7 ms)
10 A at 110 VAC 7.5 A at 110 VAC
10 A at 24 VDC
5 A at 24 VDC
Bifurcated contact
DPDT
Resistive load
Inductive load
(p.f. = 1)
(p.f. = 0.4)
(L/R = 7 ms)
5 A at 110 VAC
4 A at 110 VAC
5 A at 24 VDC
4 A at 24 VDC
10 A
7A
10 A
7A
1,100 VA
240 W
830 VA
120 W
550 VA
120 W
10 mA, 5 VDC
440 VA
100 W
■ COIL DATA
1- and 2-pole types – AC
Rated
voltage (V)
6
12
24
50
100/110
110/120
200/220
220/240
Rated current (mA)
50 Hz
214.10
106.50
53.80
25.70
11.70/12.90
9.90/10.80
6.20/6.80
4.80/5.30
60 Hz
183
91
46
22
10/11
8.40/9.20
5.30/5.80
4.20/4.60
Coil
resistance
(Ω)
12.20
46
180
788
3,750
4,430
12,950
18,790
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.04
0.08
0.17
0.33
0.69
1.30
3.22
5.66
14.54
24.60
19.20
32.10
54.75
94.07
83.50
136.40
Pick-up
Dropout
voltage
voltage
(% of rated voltage)
80% max. 30% min.
Maximum
voltage
Power
consumption
(VA, W)
110%
Approx.
1.00 to 1.20
(60 Hz)
Approx.
0.90 to 1.10
(60 Hz)
1- and 2-pole types – DC
Rated
voltage (V)
Rated current (mA)
Coil
resistance
(Ω)
6
12
24
48
100/110
150
75
36.90
18.50
9.10/10
40
160
650
2,600
11,000
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.16
0.33
0.73
1.37
3.20
5.72
10.60
21
45.60
86.20
Pick-up
Dropout
voltage
voltage
(% of rated voltage)
80% max. 10% min.
Maximum
voltage
Power
consumption
(VA, W)
110%
Approx.
0.90
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for
AC rated current, and ±15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Class B coil insulation is available.
3
LY
LY
■ COIL DATA(continued)
3-pole type – AC
Rated
voltage (V)
6
12
24
50
100/110
120
200/220
240
Rated current (mA)
50 Hz
310
159
80
38
15.90/18.30
17.30
10.50/11.60
9.40
60 Hz
270
134
67
33
13.60/15.60
14.8
9.00/9.90
8
Coil
resistance
(Ω)
6.70
24
100
410
2,300
2,450
8,650
10,400
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.03
0.05
0.12
0.21
0.44
0.79
2.24
3.87
10.50
18.50
11.50
20.60
34.80
59.50
38.60
74.60
Pick-up
Dropout
voltage
voltage
(% of rated voltage)
80% max. 30% min.
Maximum
voltage
Power
consumption
(VA, W)
110%
Approx.
1.60 to 2.00
(60 Hz)
Pick-up
voltage
Maximum
voltage
Power
consumption
(VA, W)
110%
Approx.
1.40
Pick-up
Dropout
voltage
voltage
(% of rated voltage)
80% max. 30% min.
Maximum
voltage
Power
consumption
(VA, W)
110%
Approx.
1.95 to 2.50
(60 Hz)
Pick-up
Dropout
voltage
voltage
(% of rated voltage)
80% max. 10% min.
Maximum
voltage
Power
consumption
(VA, W)
110%
Approx.
1.50
3-pole type – DC
Rated
voltage (V)
Rated current (mA)
Coil
resistance
(Ω)
6
12
24
48
100/110
234
112
58.60
28.20
12.70/13
25.70
107
410
1,700
8,500
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.11
0.21
0.45
0.98
1.89
3.87
8.53
13.90
29.60
54.30
Dropout
voltage
(% of rated voltage)
80% max. 10% min.
4-pole type – AC
Rated
voltage (V)
6
12
24
50
100/110
120
200/220
240
Rated current (mA)
50 Hz
386
199
93.60
46.80
22.50/25.50
19.00
11.50/13.10
11.00
60 Hz
330
170
80
40
19/21.80
16.40
9.80/11.20
9.50
Coil
resistance
(Ω)
5
20
78
350
1,800
2,200
6,700
9,000
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.02
0.04
0.10
0.17
0.38
0.67
1.74
2.88
10.50
17.30
9.30
19
33.10
57.90
33.20
63.40
4-pole type – DC
Rated
voltage (V)
Rated current (mA)
Coil
resistance
(Ω)
6
12
24
48
100/110
240
120
69
30
15/15.90
25
100
350
1,600
6,900
Coil inductance
(ref. value) (H)
Armature Armature
OFF
ON
0.09
0.21
0.39
0.84
1.41
2.91
6.39
13.60
32
63.70
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for
AC rated current, and ±15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Class B coil insulation is available.
4
LY
LY
■ CHARACTERISTICS
Contact resistance
Operate time
Release time
Operating frequency
Mechanically
Under rated load
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Electrically
Weight
50 mΩ max.
25 ms max.
25 ms max.
18,000 operations/hour
1,800 operations/hour
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s2 (approx. 100 G)
200 m/s2 (approx. 20 G)
-40° to 70°C (-40° to 158°F)
35 to 85% RH
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
SPDT, DPDT: Approx. 40 g (1.41 oz), 3PDT: Approx. 50 g (1.76 oz)
4PDT: Approx. 70 g (2.47 oz)
Note: Data shown are of initial value.
■ CHARACTERISTIC DATA
Rated operating current (A)
Rated operating voltage (V)
LY3, LY4
LY2Z
Rated operating current (A)
LY2
Rated operating current (A)
LY1
Rated operating current (A)
Maximum switching capacity
Rated operating voltage (V)
Rated operating voltage (V)
Rated operating voltage (V)
Rated operating current (A)
Rated operating current (A)
LY3, LY4
LY2Z
Service life (operations x 106)
Service life (operations x 106)
LY2
Service life (operations x 106)
LY1
Service life (operations x 106)
Electrical service life
Rated operating current (A)
Rated operating current (A)
5
LY
LY
Dimensions
Unit: mm (inch)
■ RELAYS
LY1
LY3
Terminal
arrangement
(Bottom view)
Terminal
arrangement
(Bottom view)
LY1-0, LY2-0, LY3-0, LY4-0
LY2
LY4
Terminal
arrangement
(Bottom view)
Mounting holes for LY1-0, LY2-0, LY3-0, LY4-0
(Bottom view)
Note: The above drawing shows LY2-0. With LY1-0,
dimension "*" should read as 6.35 (.25).
LY1F, LY2F
SPDT
Mounting
holes
Note: The above drawing shows LY1F. With LY2F, dimension “*”
should read as eight 3.05 mm (0.12 in) dia. holes.
6
Terminal
arrangement
(Bottom view)
LY3F
DPDT
3PDT
4PDT
Mounting
holes
LY
LY4F
LY1S, LY2S
LY
Mounting holes
Round hole
Rectangular hole
Note: The above drawing shows LY2S-US. With LY1S-US, dimension “*”
should read as eight 2.03 mm (0.08 in) dia. holes.
LY3S
Round hole
Rectangular hole
LY4S
Round hole
Rectangular hole
7
LY
LY
■ ACCESSORIES
Unit: mm (inch)
Track mounted sockets (UL File No. E87929) (CSA Report No. LR31928)
PTF08A-E
Terminal arrangement/
mounting holes
(Top view)
PTF11A
Terminal arrangement/
mounting holes
(Top view)
Track mounting sockets (UL File No. E87929) (CSA Report No. LR31928)
PTF14A-E
Terminal arrangement/
mounting holes
(Top view)
Mounting height of
relay with socket
(Applies to all PTF■
■ A sockets)
Note: 1. UL/CSA does not apply to wire wrap (Q) type sockets.
2. Values in brackets for LY■
■ CR.
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT08
8
Terminal arrangement
(Bottom view)
PT11
Terminal arrangement
(Bottom view)
LY
LY
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT14
Terminal arrangement
(Bottom view)
Mounting height of relay with socket
(Applies to all PT sockets)
PT
Note: Values in brackets for LY■
■ CR.
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT08QN
Panel cut-out and terminal
arrangement are the same
as Type PT08.
PT11QN
Panel cut-out and terminal
arrangement are the same
as Type PT11.
PT14QN
Panel cut-out and terminal
arrangement are the same
as Type PT14.
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT08-0
Terminal arrangement is
the same as Type PT08.
Mounting holes
(Bottom view)
PT11-0
Terminal arrangement is
the same as Type PT11.
Mounting holes
(Bottom view)
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT14-0
Terminal arrangement is
the same as Type PT14.
Mounting holes
(Bottom view)
9
LY
LY
■ ACCESSORIES (continued)
Unit: mm (inch)
Relay hold-down clips
PYC-A1
For PTF■
■ A socket
PYC-S
For relay mounting plates
(Applicable to Type PYP-1 and PYP-18
socket mounting plates only.)
PYC-P
For PT■
■ socket
Relay hold-down clips
PYC-P2
For push-to-test button type with
PT■
■ socket
Y92H-3
For RC circuit type
PYC-1
For RC circuit type
Mounting track/end plate/spacer
PFP-100N/PFP-50N mounting track
10
PFP-M end plate
LY
LY
PFP-100N2 mounting track
PFP-S spacer
* This dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in the case of PFP-50N.
** L = Length
PFP-50N
............... L = 497.84 mm (19.60 in)
PFP-100N ............... L = 990.60 mm (39.00 in)
PFP-100N2 ............... L = 990.60 mm (39.00 in)
*** A total of twelve 24.89 x 4.57 mm (0.98 x 0.18 in) elliptic holes are provided, with six holes cut from each end of the track at a pitch
of 9.91 (0.39) between holes.
Socket mounting plates [t=1.52 (.06)]
Socket needed
PT08, PT08QN
PT11, PT11QN
PT14, PT14QN
PYP-1
PTP-10
PTP-1-3
PTP-1
Number of socket specs.
1
10
PYP-1
–
PTP-1-3
–
PTP-1
PTP-10
12
–
PTP-1-2
–
18
PYP-18
_
–
PYP-18
PTP-12
11
LY
LY
■ RELAY OPTIONS
LED Indicator
Specifications and dimensions same as the Standard Type with the following exception. With the LED indicator type, the rated current
is approximately 0 to 5.0 mA higher than the Standard Type.
Terminal arrangement/Internal connections (Bottom view)
LY2N
DC coil rating type
AC coil rating type
Note: 1. The coil terminals 10 and 11 of Type LY3N become (-) and (+) and terminals 13 and 14 of Type LY4N become (-) and (+),
respectively.
2. Pay special attention to the polarities when using the DC type.
Diode Surge Suppression
Specifications and dimensions same as the Standard Type with the following exception. Ambient operating temperature: -25° to 40°C
(-13° to 104°F)
Without Diode
With Diode
Terminal arrangement/Internal connections (Bottom view)
LY2(N)-D(2)
LY2-D
6, 12, 24, 48
100/110 VDC
Note: 1.
2.
3.
4.
12
LY2N-D2
6, 12, 24, 48 VDC
Pay special attention to the polarities when using the DC type.
The release time is somewhat longer, but satisfies the standard specifications of 25 ms.
The reverse-breakdown voltage of the diode is 1,000 VDC.
Available on DC versions only.
LY2N-D2
100/110 VDC
LY
LY
■ RELAY OPTIONS
RC Circuit
Specifications and dimensions same as the Standard Type with the following exceptions.
Characteristic Data
Without RC circuit
With RC circuit
LY1-CR, LY2(Z)-CR
Terminal arrangement/Internal connections (Bottom view)
LY1-CR
LY2(Z)-CR
Note: 1. The above drawing shows LY2(Z)-CR. With LY1-CR, “*” should read eight 2.03 mm (0.08 in) dia. holes.
2. Available on AC versions only.
Push-to-test Button
Specifications and dimensions same as the Standard Type with the following exceptions.
LY■
■ 12
LY112, LY212
Note: Type LY112 has the same dimensions and appearances as Type LY212 shown except that dimension “*” is 2.03 mm (0.08 in)
dia. holes
LY312
LY412
13
LY
LY
■ APPROVALS
UL recognized type (File No. E41643)
Type
LY■
■
Contact form
SPDT
LY■
■
DPDT
LY■
■
3PDT
4PDT
Coil ratings
6 to 240 VAC
6 to 120 VDC
Contact ratings
15 A, 240 VAC (Inductive)
15 A, 28 VDC (Resistive)
TV-5 (ACTV)
1/2 HP, 120 VAC (Motor)
13 A, 120 VAC (Resistive)
12 A, 240 VAC (Inductive)
10 A, 28 VDC (Resistive)
TV-3 (ACTV)
1/2 HP, 120 VAC (Motor)
10 A, 240 VAC (Inductive)
10 A, 28 VDC (Resistive)
1/2 HP, 240 VAC (Motor)
Coil ratings
6 to 240 VAC
6 to 120 VDC
Contact ratings
15 A, 120 VAC (Inductive)
10 A, 240 VAC (Inductive)
15 A, 28 VDC (Resistive)
TV-5 (ACTV)
13 A, 28 VDC (Resistive)
12 A, 120 VAC (Inductive)
10 A, 240 VAC (Inductive)
1/3 HP, 120 VAC (Motor)
TV-3 (ACTV)
10 A, 240 VAC (Inductive)
10 A, 28 VDC (Resistive)
CSA certified type (File No. LR31928)
Type
LY■
■
Contact form
SPDT
LY■
■
DPDT
LY■
■
3PDT
4PDT
VDE approved type (File No. 9903 [SPDT, DPDT & 3PDT], File No. 9947 [4PDT])
Type
LY■
■ -VD
Contact form
SPDT
LY■
■ -VD
DPDT
3PDT
4PDT
Coil ratings
6, 12, 24, 50,
110, 220 VAC
and 6, 12, 24,
48, 110 VDC
Contact ratings
10 A, 220 VAC (Resistive)
10 A, 28 VDC (Resistive)
7 A, 220 VAC (Inductive)
7 A, 28 VDC (Inductive)
7 A, 220 VAC (Resistive)
7 A, 28 VDC (Resistive)
4 A, 220 VAC (Inductive)
4 A, 28 VDC (Inductive)
LR (Lloyd's Register) approved type (File No. 562KOB-204523)
Type
LY■
■
Contact form
DPDT
4PDT
Coil ratings
6 to 240 VAC
6 to 110 VDC
Contact ratings
7.5 A, 230 VAC (Inductive)
5 A, 24 VDC (Inductive)
SEV listed type (File No. D7 91/82 [2- & 4-pole], D 91/204a [1- & 3-pole])
Type
LY■
■ -SV
Contact form
SPDT
LY■
■ -SV
DPDT
3PDT
4PDT
Coil ratings
6 to 240 VAC
6 to 110 VDC
Contact ratings
15 A, 220 VAC (Resistive)
15 A, 24 VDC (Resistive)
10 A, 220 VAC (Resistive)
10 A, 24 VDC (Resistive)
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, VDE, and SEV) may be different from the performance
characteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
14
LY
LY
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
01/00
Specifications subject to change without notice.
Printed in the U.S.A.
15
Similar pages