KNOWLES 2403-260

2403 260 00051
RECEIVER-612-2-SC
Page 1 of 19
©2011 Knowles Electronics
2403 260 00051
Contents
1.
Theory of operation............................................................................................................................. 3
2.
Mechanical Layout and Dimensions.................................................................................................... 4
2.1. Main Dimensions .........................................................................................................................4
2.2. PWB Layout .................................................................................................................................5
2.3. Spring Force .................................................................................................................................5
2.4. Force on component ...................................................................................................................6
2.5. Part Marking/Labeling .................................................................................................................7
2.6. Material List .................................................................................................................................8
3.
Electrical and Acoustical Specifications............................................................................................... 9
3.1. Frequency response ....................................................................................................................9
3.2. Electro-Acoustic Parameters .....................................................................................................10
3.3. Power handling..........................................................................................................................10
3.4. Measurement setup ..................................................................................................................11
3.5. Measured Parameters ...............................................................................................................11
3.6. Measurement adapter ..............................................................................................................12
4.
Environmental Conditions ................................................................................................................. 13
4.1. Storage.......................................................................................................................................13
4.2. Transportation ...........................................................................................................................13
4.3. Functionality ..............................................................................................................................13
5.
Environmental tests .......................................................................................................................... 14
5.1. Qualification tests......................................................................................................................14
5.2. Reliability tests ..........................................................................................................................14
5.3. Sample Size, Sequence ..............................................................................................................14
5.4. Period of Shelf-Life ....................................................................................................................14
5.5. Testing Procedures ....................................................................................................................14
6.
Related Documents ........................................................................................................................... 18
7.
Change History .................................................................................................................................. 19
8.
Disclaimer .......................................................................................................................................... 19
Release – Revision: F
Page 2 of 19
©2011 Knowles Electronics
2403 260 00051
1.
Theory of operation
Receiver 612-2-SC is a high end micro size receiver specifically designed for mobile phone and other
applications where high quality sound is needed and only very little space for components is available.
Release – Revision: F
Page 3 of 19
©2011 Knowles Electronics
2403 260 00051
2.
Mechanical Layout and Dimensions
2.1. Main Dimensions
Release – Revision: F
Page 4 of 19
©2011 Knowles Electronics
2403 260 00051
2.2. PWB Layout
2.3. Spring Force
Release – Revision: F
Page 5 of 19
©2011 Knowles Electronics
2403 260 00051
2.4. Force on component
FORCES ON DIFFERENT STATE OF COMPONENT
STATE
FROM FRONT TO BACK
FROM SIDE 1 TO SIDE 1
FROM SIDE 2 TO SIDE 2
POT
MEMBRANE
PULL OF FORCE (Cover)
Release – Revision: F
MIN. SURFACE
OF PREASURE
[mm²]
3
10
-
Page 6 of 19
MAX
PERMANENT
FORCE [N]
10
10
10
0
0
0
MAX HANDLING
FORCE [N]
15
15
15
10
0
5
©2011 Knowles Electronics
2403 260 00051
2.5. Part Marking/Labeling
The samples have a serial number on bottom (pot) side
Release – Revision: F
Page 7 of 19
©2011 Knowles Electronics
2403 260 00051
2.6. Material List
1.
Material of basket:
Polycarbonate (Halogen free)
2.
Material of membrane:
Polyarylate-Compound
3.
Material of pot:
soft magnetic Iron
4.
Material of magnet:
Nd Fe B
5.
Material of contact
CrNi Steel gold plated
6.
Material of cover:
Brass
7.
Dimensions:
6x12x2 mm
8.
Mass:
0,35 g
Release – Revision: F
Page 8 of 19
©2011 Knowles Electronics
2403 260 00051
3.
Electrical and Acoustical Specifications
3.1. Frequency response
Typical frequency response measured on baffle according to chapter 2.4
(distance d = 1cm, p= 10mW, without back cavity)
Release – Revision: F
f
[Hz]
lower limit
[dB SPL]
(floating)
Tolerance window
upper limit
[dB SPL]
(floating)
160
300
350
400
1000
2500
4000
7500
8000
10000
70
85
88
88
83
83
84
88
75
75
80
94
94
87
87
89
96
96
Page 9 of 19
f
[Hz]
upper limit
[%THD]
300
400
600
6300
40
20
5
5
©2011 Knowles Electronics
2403 260 00051
3.2. Electro-Acoustic Parameters
Loudspeaker mounted in adapter acc. to 2.6.
1. Rated impedance
Z:
32Ω
2. Voice coil resistance
R:
28.8Ω±10%
3. Resonance frequency (measured @10mW)
f0:
350Hz±15%
4. Maximum usable excursion xmax
p-p:
0.6mm p-p
5. Nominal characteristic sensitivity (calculated for 1W in 1m)
average from 1kHz to 3kHz
65±2dB
5.1. Measured characteristic sensitivity (at 10mW in 1cm)
average from 1kHz to 3kHz
85±2dB
6. THD
7. Rub & buzz
according chapter 2.1.
< 60dBSPL (300Hz -1500Hz) in 1cm at 10mW (566mVeff)
All acoustic measurements at 23±2°C
3.3. Power handling
Receiver mounted in lifetime test device (open rear/open front)
1. Max short term power
75mW (RMS)
Signal: pink noise HP 2nd order 800Hz, LP 10th order 6,3kHz, crest factor 2
2. Max continuous power
(500h)
10mW (RMS)
Signal: pink noise shaped according to diagram below:
HP10th order 100Hz, HP 2nd order 400Hz, LP 10th order 6,3kHz, crest factor 2
Release – Revision: F
Page 10 of 19
©2011 Knowles Electronics
2403 260 00051
3.4. Measurement setup
IEC BAFFLE
Rq,including wiring <0,3Ω
freefield
microphone 1/4“
power amplifier
analyzer
≈
d
3.5. Measured Parameters
3.5.1.
Sensitivity
SPL is expressed in dB rel 20µPa, computed according to IEC 268-5.
Measurement set up and parameters according chapter 3.4.
This test is performed for 100% of products in the production line.
3.5.2.
Frequency response
Frequency response is measured according test set up in chapter 3.4 data sheet and checked against
the tolerance window defined in chapter 3.1. This Test is performed for 100% of products in the
production line.
3.5.3.
Total harmonic distortion (THD)
Is measured according IEC 268-5 (2nd to 5th harmonics) and test set up in chapter 3.4. This test is
performed for 100% of products in the production line.
3.5.4.
Rub& Buzz
Rub & Buzz will be measured in the Inline-measuring device with a sinusoidal sweep. Rub & Buzz is
defined as the maximum level of no harmonic energy, expressed as signal to non-harmonic content
ratio, in a certain frequency-range. Signal and evaluation criteria are according to chapter 3.2. This test
is performed for 100% of products in the production line.
Release – Revision: F
Page 11 of 19
©2011 Knowles Electronics
2403 260 00051
3.6. Measurement adapter
Release – Revision: F
Page 12 of 19
©2011 Knowles Electronics
2403 260 00051
4.
Environmental Conditions
4.1. Storage
The transducer fulfils the specified data after treatment according to the conditions of
ETS 300 019-2-1
Specification of environmental test: Storage
Test spec. T 1.2: Weather protected, not temperature controlled storage
locations.
4.2. Transportation
The transducer fulfils the specified data after treatment according to the conditions of
ETS 300 019-2-2
Specification of environmental test: Transportation
Test Spec. T 2.3: Public Transportation
4.3. Functionality
The transducer fulfils the specified data after treatment according to the conditions of
ETS 300 019-2-5
ETS 300 019-2-7
Release – Revision: F
Specification of environmental test: Ground vehicle installations
Test spec. T 5.1: Protected installation
Specification of environmental test: Portable and non-stationary use
Test spec. T 7.3E: Partly weather protected and non-weather protected
locations.
Page 13 of 19
©2011 Knowles Electronics
2403 260 00051
5.
Environmental tests
5.1. Qualification tests
According to our milestone plan (Product Creation Process), a complete qualification test will be done
at design validation of products manufactured under serial conditions.
1x per year and product family a requalification takes place. The qualification process covers all tests
described under 5.5 and a complete inspection.
5.2. Reliability tests
1x per month and product family samples are taken and submitted to tests described under 5.5.2
5.3. Sample Size, Sequence
Unless otherwise stated 20 arbitrary new samples will be used to perform each test for both,
qualification and requalification test as described under 5.1 and 5.2.
5.4. Period of Shelf-Life
The period of shelf-life is 2 years.
5.5. Testing Procedures
5.5.1.
Storage Tests
5.5.1.1.
Low Temperature Storage Test
Parameter
Test Method and
Conditions
Duration
Evaluation Standard
Low Temperature
Storage
-40°C
168h
Measurements after 2 hours
recovery time.
(Ref. EN 60068-2-1)
rel. humidity not
controlled
All samples fully operable.
All acoustical parameters
according specification with
tolerances increased by 50 %.
5.5.1.2.
High Temperature Storage Test
Parameter
Test Method and
Conditions
Duration
Evaluation Standard
Dry Heat Storage
+85°C
168h
(Ref. EN 60068-2-2)
rel. humidity not
controlled
Measurements after 2 hours
recovery time.
All samples fully operable.
All acoustical parameters
according specification with
tolerances increased by 50 %.
Release – Revision: F
Page 14 of 19
©2011 Knowles Electronics
2403 260 00051
5.5.1.3.
Temperature Cycle Test
Parameter
Test Method and
Conditions
Duration
Evaluation Standard
Change of Temperature
-40°C/+85°C
5 cycles
(Ref. EN 60068-2-14)
Transition time <3 min.
See Figure 5-1 below
>2h for each
temperature
Measurements after 2 hours
recovery time.
All samples fully operable.
All acoustical parameters
according specification with
tolerances increased by 50 %.
+85°C
-40°C
2h
3m
2h
3m
2h
3m
2h
3m
2h
3m
2h
3m
2h
3m
2h
3m
2h
3m
2h
3m
Figure 5-1: Temperature Cycle Test
5.5.1.4.
Temperature / Humidity Cycle Test
Parameter
Test Method and
Conditions
Duration
Evaluation Standard
Measurements after 2 hours
recovery time.
Damp heat, cyclic
+25°C/+55°C
6 cycles.
(Ref. IEC 60068-2-30)
90% to 95% RH.
24h at each
temperature
Temp. change time <3h
See Figure 5-2 below
All samples fully operable.
All acoustical parameters
according specification with
tolerances increased by 50 %.
Caution: no condensed
water on products!
Figure 5-2: Temperature / Relative Humidity Cycle Test
5.5.2.
+55°C
+25°C
9h
Release – Revision: F
3h
9h
3h
9h
3h
9h
3h
9h
3h
9h
3h
9h
Page 15 of 19
3h
9h
3h
9h
3h
9h
3h
9h
3h
9h
3h
©2011 Knowles Electronics
2403 260 00051
Operating Tests
5.5.2.1.
Cold Operation Test
Parameter
Test Method and
Conditions
Duration
Evaluation Standard
Cold Operation Test
-20°C
72h
(Ref. EN 60068-2-1)
rel. humidity not
controlled
Measurements after 2 hours
recovery time.
All samples fully operable.
THD may be increased after
test. All other acoustical
parameters according
specification with tolerances
increased by 50 %.
signal acc. Chapter 3.3
5.5.2.2.
Dry Heat Operation Test
Parameter
Test Method and
Conditions
Duration
Evaluation Standard
Dry Heat Operation
+70°C
500h
(Ref. EN 60068-2-2)
rel. humidity not
controlled
Measurements after 2 hours
recovery time.
All samples fully operable.
The allowable change in
sensitivity shall not be greater
than 3 dB. All other acoustical
parameters according
specification with tolerances
increased by 50 %.
signal acc. Chapter 3.3
5.5.3.
Salt Mist Test
Parameter
Test Method and
Conditions
Duration
Evaluation Standard
Salt Mist
The part must be
subjected to 2 hours
spray of 5% NaCl salt
mist, at 35°C then be
left at 40°C and 95%
RH for 22h.
3 cycles
The samples shall be washed
after the test with distilled water
and dried at T< 50°C.
(Ref. IEC60068-2-52,
Kb / Severity 2
Release – Revision: F
Component may have reduced
performance, but must still
function properly. The allowable
sensitivity difference shall not
be greater than ±3dB from
initial sensitivity.
Page 16 of 19
©2011 Knowles Electronics
2403 260 00051
5.5.4.
Shock Resistance Test (Free Fall Test) - unprotected product
Parameter
Test Method and
Conditions
Conditions /
Sample size
Evaluation Standard
Mechanical shock
Drop of sample without
fixation of release plane
from a height of 1.5m
onto concrete floor.
Each 3 shocks
in both
directions of the
3 axes.
Component may have reduced
performance, but must still
function properly. The allowable
sensitivity difference shall not
be greater than ±3dB from
initial sensitivity.
(Ref. IEC60068-2-32
Ed), Procedure 1
(18 drops in
total)
5.5.5.
Impact Durability Test (Tumble Test) – protected product
Parameter
Test Method and
Conditions
Conditions /
Sample size
Evaluation Standard
Impact durability (in a
Tumble Tester)
Speaker in drop test box
or representative
mechanics. Random
drops on steel base.
30 units
180 drops, 1m
Component may have reduced
performance, but must still
function properly. The
allowable sensitivity difference
shall not be greater than ±3 dB
from initial sensitivity.
(Ref. IEC60068-2-32
Ed)
DUT power off
(SPR a7.1.1)
5.5.6.
Resistance to Electrostatic Discharge
Parameter
Test Method and
Conditions
Conditions /
Sample size
Evaluation Standard
Resistance to ESD
One pole is grounded and
the ESD pulse is applied
to the other pole. The
speaker must be stressed
first with one polarisation
and then with the other
polarisation. DUT must be
discharged between each
ESD exposure.
10 exposures on
each polarity / 5
units
All samples fully operable.
IEC61000-4-2 Level 4
(SPR c 2.5.1)
DUT Power off
All acoustical parameters
according specification with
tolerances increased by
50%.
Level 4: contact +/- 8kV,
air +/- 15kV
Release – Revision: F
Page 17 of 19
©2011 Knowles Electronics
2403 260 00051
6.
Related Documents
IEC 268-5
IEC 68-2
EN 60068-2
ISO 2859 - 1
ISO 3951
ETS 300 019-2-1
ETS 300 019-2-2
ETS 300 019-2-5
ETS 300 019-2-7
Release – Revision: F
Sound System equipment
Part 5: Loudspeaker
Environmental testing
Environmental testing
Sampling procedures for inspection by attributes
Part 1: Sampling plans indexed by acceptable quality level (AQL) for lot-by-lot
inspection
Sampling procedures and charts for inspection by variables for percent
defectives.
Specification of environmental test: Storage
Test spec. T 1.2: Weather protected, not temperature controlled storage
locations
Specification of environmental test: Transportation
Test spec. T 2.3: Public Transportation
Specification of environmental test: Ground vehicle installations
Test spec. T 5.1: Protected installation
Specification of environmental test: Portable and non-stationary use
Test spec. T 7.3E: Partly weather protected and non-weather protected
locations
Page 18 of 19
©2011 Knowles Electronics
2403 260 00051
7.
Change History
Status
Version
Date
ECR
Comment / Changes
Initials of
owner
Obsolete
A
19.08.10
2909
First release
CP/ET/AS
Obsolete
B
07.01.11
3055
Update frequency response/lifetime test signal
AH
Obsolete
C
24.03.11
3125
Update printing code/migration to Knowles template
SA/CP
Obsolete
D
26.05.11
3180
Update printing code illustration/shelf life
CP/PD
Obsolete
E
26.07.11
3207
Shelf life 2 years
CP
Release
F
03.01.12
3428
Correct THD curve/new frontpage picture
Change of short term max power
OL/CP/AH
8.
Disclaimer
Stresses above the Absolute Maximum Ratings may cause permanent damage to the device. These are
stress ratings only. The device may not function when operated at these or any other conditions
beyond those indicated under “Electrical and Acoustical Specifications”. Exposure beyond those
indicated under “Electrical and Acoustical Specifications” for extended periods may affect device
reliability.
This product is not qualified for use in
automotive applications
Frequency range in telecom application:
300 Hz – 3,4 kHz
The information contained in this literature is based on our experience to date and is believed to be reliable and it is subject to change without notice. It is
intended as a guide for use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in
connection with its use. Dimensions contained herein are for reference purposes only. For specific dimensional requirements consult factory. This publication
is not to be taken as a license to operate under, or recommendation to infringe any exiting patents. This supersedes and voids all previous literature.
Release – Revision: F
Page 19 of 19
©2011 Knowles Electronics