Numonyx M29W128GH60N6E 128 mbit (16 mb x 8 or 8 mb x 16, page, uniform block) 3 v supply flash memory Datasheet

M29W128GH
M29W128GL
128 Mbit (16 Mb x 8 or 8 Mb x 16, page, uniform block)
3 V supply Flash memory
Features
■
■
Supply voltage
– VCC = 2.7 to 3.6 V for Program, Erase and
Read
– VCCQ = 1.65 to 3.6 V for I/O buffers
– VPPH = 12 V for Fast Program (optional)
Asynchronous Random/Page Read
– Page size: 8 words or 16 bytes
– Page access: 25, 30 ns
– Random access: 60 (only available upon
customer request) or 70, 80 ns
■
Fast Program commands
– 32 words (64-byte write buffer)
■
Enhanced Buffered Program commands
– 256 words
■
TSOP56 (N)
14 x 20 mm
BGA
TBGA64 (ZA)
10 x 13 mm
– Faster Production/Batch Programming
– Faster Block and Chip Erase
Programming time
– 16 µs per byte/word typical
– Chip program time: 5 s with VPPH and 8 s
without VPPH
■
VPP/WP pin for Fast Program and Write:
protects first or last block regardless of block
protection settings
■
Software protection:
– Volatile protection
– Non-volatile protection
– Password protection
■
Memory organization
– M29128GH/L: 128 main blocks,
128 Kbytes/64 Kwords each
■
■
Program/Erase controller
– Embedded byte/word program algorithms
Common Flash interface
– 64 bit security code
■
128 word extended memory block
– Extra block used as security block or to
store additional information
■
Low power consumption
– Standby and automatic standby
■
Minimum 100,000 Program/Erase cycles per
block
■
ECOPACK® packages
■
Program/ Erase Suspend and Resume
– Read from any block during Program
Suspend
– Read and Program another block during
Erase Suspend
■
Unlock Bypass/Block Erase/Chip Erase/Write
to Buffer/Enhanced Buffered Program
commands
Table 1.
Device summary
Root part number
Device code
M29W128GH: uniform, last block protected by VPP/WP
227Eh + 2221h + 2201h
M29W128GL: uniform, first block protected by VPP/WP
227Eh + 2221h + 2200h
March 2008
Rev 4
1/94
www.numonyx.com
1
Contents
M29W128GH, M29W128GL
Contents
1
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2
Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3
4
2/94
2.1
Address inputs (A0-A22) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2
Data inputs/outputs (DQ0-DQ7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3
Data inputs/outputs (DQ8-DQ14) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.4
Data inputs/outputs or address inputs (DQ15A-1) . . . . . . . . . . . . . . . . . . 13
2.5
Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.6
Output Enable (G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.7
Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.8
VPP/Write Protect (VPP/WP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.9
Reset (RP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.10
Ready/Busy output (RB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.11
Byte/word organization select (BYTE) . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.12
VCC supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.13
VCCQ input/output supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.14
Vss ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1
Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2
Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.3
Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.4
Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.5
Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.6
Automatic Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.7
Auto Select mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.7.1
Read electronic signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.7.2
Verify extended memory block protection indicator . . . . . . . . . . . . . . . . 19
3.7.3
Verify block protection status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.7.4
Hardware Block Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Hardware protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
M29W128GH, M29W128GL
5
Software protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1
Volatile protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.2
Non-volatile protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.3
6
Contents
5.2.1
Non-volatile protection bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.2.2
Non-volatile Protection Bit Lock bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Password protection mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Command interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1
6.2
6.3
Standard commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1.1
Read/Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1.2
Auto Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1.3
Read CFI Query command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.1.4
Chip Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.1.5
Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.1.6
Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.1.7
Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.1.8
Program Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.1.9
Program Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.1.10
Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Fast Program commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.2.1
Write to Buffer Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.2.2
Enhanced Buffered Program command . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.2.3
Buffered Program Abort and Reset command . . . . . . . . . . . . . . . . . . . . 36
6.2.4
Write to Buffer Program Confirm command . . . . . . . . . . . . . . . . . . . . . . 37
6.2.5
Enhanced Buffered Program Confirm command . . . . . . . . . . . . . . . . . . 37
6.2.6
Unlock Bypass command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.2.7
Unlock Bypass Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.2.8
Unlock Bypass Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.2.9
Unlock Bypass Chip Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.2.10
Unlock Bypass Write to Buffer Program command . . . . . . . . . . . . . . . . 38
6.2.11
Unlock Bypass Enhanced Buffered Program command . . . . . . . . . . . . 38
6.2.12
Unlock Bypass Reset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Protection commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
6.3.1
Enter Extended Memory Block command . . . . . . . . . . . . . . . . . . . . . . . 42
6.3.2
Exit Extended Memory Block command . . . . . . . . . . . . . . . . . . . . . . . . 42
6.3.3
Lock Register command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3/94
Contents
7
M29W128GH, M29W128GL
6.3.4
Password Protection mode command set . . . . . . . . . . . . . . . . . . . . . . . 43
6.3.5
Non-volatile Protection mode command set . . . . . . . . . . . . . . . . . . . . . 44
6.3.6
NVPB Lock Bit command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
6.3.7
Volatile Protection mode command set . . . . . . . . . . . . . . . . . . . . . . . . . 46
6.3.8
Exit Protection command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.1
7.2
7.3
Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.1.1
Password Protection Mode Lock bit (DQ2) . . . . . . . . . . . . . . . . . . . . . . 51
7.1.2
Non-volatile Protection Mode Lock bit (DQ1) . . . . . . . . . . . . . . . . . . . . . 51
7.1.3
Extended Block Protection bit (DQ0) . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.1.4
DQ15 to DQ3 reserved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.2.1
Data Polling bit (DQ7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.2.2
Toggle bit (DQ6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.2.3
Error bit (DQ5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.2.4
Erase Timer bit (DQ3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
7.2.5
Alternative Toggle bit (DQ2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Buffered Program Abort bit (DQ1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
8
Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
9
DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
10
Package mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
11
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Appendix A Block addresses and read/modify protection groups . . . . . . . . . . 78
Appendix B Common Flash interface (CFI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Appendix C Extended memory block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
C.1
Factory locked extended memory block . . . . . . . . . . . . . . . . . . . . . . . . . . 87
C.2
Customer lockable extended memory block . . . . . . . . . . . . . . . . . . . . . . . 88
Appendix D Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4/94
M29W128GH, M29W128GL
12
Contents
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
5/94
List of tables
M29W128GH, M29W128GL
List of tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
Table 17.
Table 18.
Table 19.
Table 20.
Table 21.
Table 22.
Table 23.
Table 24.
Table 25.
Table 26.
Table 27.
Table 28.
Table 29.
Table 30.
Table 31.
Table 32.
Table 33.
Table 34.
Table 35.
Table 36.
Table 37.
Table 38.
Table 39.
Table 40.
Table 41.
Table 42.
6/94
Device summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
VPP/WP functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Bus operations, 8-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Bus operations, 16-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Read electronic signature - auto select mode - programmer method (8-bit mode) . . . . . . 21
Read electronic signature - auto select mode - programmer method (16-bit mode) . . . . . 21
Block protection - auto select mode - programmer method (8-bit mode) . . . . . . . . . . . . . . 22
Block protection - auto select mode - programmer method (16-bit mode) . . . . . . . . . . . . . 22
Standard commands, 8-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Standard commands, 16-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Fast Program commands, 8-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Fast Program commands, 16-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Enhanced Buffered Program commands, 16-bit mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Block Protection commands, 8-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Block Protection commands, 16-bit mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Program, Erase times and Program, Erase endurance cycles . . . . . . . . . . . . . . . . . . . . . . 50
Lock Register bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Block protection status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Status Register bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Operating and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Power-up waiting timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Device capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Read AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Write AC characteristics, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Write AC characteristics, Chip Enable Controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Reset AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Accelerated Program and Data Polling/Data Toggle AC characteristics . . . . . . . . . . . . . . 74
TSOP56 – 56 lead plastic thin small outline, 14 x 20 mm, package mechanical data . . . . 75
TBGA64 10 x 13 mm - 8 x 8 active ball array, 1 mm pitch, package mechanical data. . . . 76
Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Block addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Query structure overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
CFI query identification string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
CFI query system interface information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Device geometry definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Primary algorithm-specific extended query table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Security code area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Extended memory block address and data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
M29W128GH, M29W128GL
List of figures
List of figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Figure 11.
Figure 12.
Figure 13.
Figure 14.
Figure 15.
Figure 16.
Figure 17.
Figure 18.
Figure 19.
Figure 20.
Figure 21.
Figure 22.
Figure 23.
Figure 24.
Figure 25.
Figure 26.
Figure 27.
Figure 28.
Figure 29.
Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
TSOP connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TBGA connections (top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Block addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Software protection scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
NVPB Program/Erase algorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Lock Register program flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Data polling flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Toggle flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
AC measurement load circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
AC measurement I/O waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Power-up waiting timings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Random Read AC waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Random Read AC waveforms (16-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Page Read AC waveforms (16-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Write Enable Controlled Program waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . 66
Write Enable Controlled Program waveforms (16-bit mode) . . . . . . . . . . . . . . . . . . . . . . . 67
Chip Enable Controlled Program waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . 69
Chip Enable Controlled Program waveforms (16-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . 70
Chip/Block Erase waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Reset AC waveforms (no program/erase ongoing). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Reset during program/erase operation AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Accelerated program timing waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Data polling AC waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Toggle/Alternative Toggle bit polling AC waveforms (8-bit mode) . . . . . . . . . . . . . . . . . . . 74
TSOP56 – 56 lead plastic thin small outline, 14 x 20 mm, package outline . . . . . . . . . . . . 75
TBGA64 10 x 13 mm - 8 x 8 active ball array, 1 mm pitch, package outline . . . . . . . . . . . 76
Write to Buffer Program flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Enhanced Buffered Program flowchart and pseudocode . . . . . . . . . . . . . . . . . . . . . . . . . . 91
7/94
Description
1
M29W128GH, M29W128GL
Description
The M29W128GH and M29W128GL are 128 Mbit (8 Mb x 16 or 16 Mb x 8) non-volatile
Flash memories that can be read, erased and reprogrammed. These operations can be
performed using a single low voltage (2.7 to 3.6 V) supply. On power-up the memory
defaults to its Read mode.
The memory array is divided into 64-Kword/128-Kbyte uniform blocks that can be erased
independently so it is possible to preserve valid data while old data is erased. Program and
Erase commands are written to the command interface of the memory. An on-chip
Program/Erase controller simplifies the process of programming or erasing the memory by
taking care of all of the special operations that are required to update the memory contents.
The end of a program or erase operation can be detected and any error conditions
identified. The command set required to control the memory is consistent with JEDEC
standards.
Chip Enable, Output Enable and Write Enable signals control the bus operation of the
memory. They allow simple connection to most microprocessors, often without additional
logic.
The M29W128GH and M29W128GL support Asynchronous Random Read and Page Read
from all blocks of the memory array. The devices also feature a Write to Buffer Program
capability that improves the programming throughput by programming in one shot a buffer of
32 words/64 bytes. The Enhanced Buffered Program feature is also available to speed up
the programming throughput, allowing to program 256 words in one shot (only in x 16
mode). The VPP/WP signal can be used to enable faster programming of the device.
The M29W128GH and M29W128GL have an extra block, the extended block, of 128 words
in x 16 mode or of 256 bytes in x 8 mode that can be accessed using a dedicated command.
The extended block can be protected and so is useful for storing security information.
However the protection is not reversible, once protected the protection cannot be undone.
The device features different levels of hardware and software block protection to avoid
unwanted program or erase (modify):
●
Hardware protection:
–
●
The VPP/WP provides a hardware protection of the highest and lowest block on
the M29W128GH, M29W128GL, respectively.
Software protection:
–
Volatile protection
–
Non-volatile protection
–
Password protection
The M29W128GH and M29W128GL are offered in TSOP56 (14 x 20 mm), and TBGA64
(10 x 13 mm, 1 mm pitch), packages. The memories are delivered with all the bits erased
(set to ‘1’).
8/94
M29W128GH, M29W128GL
Table 2.
Description
Signal names
Name
A0-A22
Description
Direction
Address inputs
Inputs
DQ0-DQ7
Data inputs/outputs
I/O
DQ8-DQ14
Data inputs/outputs
I/O
Data input/output or address input
I/O
DQ15A−1
E
Chip Enable
Input
G
Output Enable
Input
W
Write Enable
Input
RP
Reset
Input
RB
Ready/Busy output
Output
BYTE
Byte/word organization select
VCCQ
Input/output buffer supply voltage
Supply
Supply voltage
Supply
VCC
VPP/WP(1)
Input
VPP/Write Protect
Input
VSS
Ground
-
NC
Not connected
-
1. VPP/WP may be left floating as it is internally connected to a pull-up resistor which enables Program/Erase
operations.
Figure 1.
Logic diagram
VCC VCCQ VPP/WP
23
15
A0-A22
DQ0-DQ14
DQ15A-1
W
E
M29W128GH
M29W128GL
G
RB
RP
BYTE
VSS
AI13330b
1. Also see Appendix A and Table 34 for a full listing of the block addresses.
9/94
Description
Figure 2.
M29W128GH, M29W128GL
TSOP connections
NC
A22
A15
A14
A13
A12
A11
A10
A9
A8
A19
A20
W
RP
A21
VPP/WP
RB
A18
A17
A7
A6
A5
A4
A3
A2
A1
NC
NC
1
56
14
43
M29W128GH
15 M29W128GL 42
28
29
NC
NC
A16
BYTE
VSS
DQ15A-1
DQ7
DQ14
DQ6
DQ13
DQ5
DQ12
DQ4
VCC
DQ11
DQ3
DQ10
DQ2
DQ9
DQ1
DQ8
DQ0
G
VSS
E
A0
NC
VCCQ
AI13331
10/94
M29W128GH, M29W128GL
Figure 3.
Description
TBGA connections (top view through package)
1
2
3
4
5
6
7
8
A
NC
A3
A7
RB
W
A9
A13
NC
B
NC
A4
A17
VPP/WP
RP
A8
A12
A22
C
NC
A2
A6
A18
A21
A10
A14
NC
D
NC
A1
A5
A20
A19
A11
A15
VCCQ
E
NC
A0
DQ0
DQ2
DQ5
DQ7
A16
VSS
F
VCCQ
E
DQ8
DQ10
DQ12
DQ14
BYTE
NC
G
NC
G
DQ9
DQ11
VCC
DQ13
DQ15
A-1
NC
H
NC
VSS
DQ1
DQ3
DQ4
DQ6
VSS
NC
AI11527c
11/94
Description
Figure 4.
M29W128GH, M29W128GL
Block addresses
(x 8)
Address lines A22-A0, DQ15A-1
FFFFFFh
(x 16)
Address lines A22-A0
7FFFFFh
128 Kbytes
64 Kwords
Total of 128
uniform blocks
01FFFFh
128 Kbytes
64 Kwords
010000h
00FFFFh
007FFFh
128 Kbytes
000000h
64 Kwords
000000h
AI13332
12/94
M29W128GH, M29W128GL
2
Signal descriptions
Signal descriptions
See Figure 1: Logic diagram, and Table 2: Signal names, for a brief overview of the signals
connected to this device.
2.1
Address inputs (A0-A22)
The Address inputs select the cells in the memory array to access during Bus Read
operations. During Bus Write operations they control the commands sent to the command
interface of the Program/Erase controller.
2.2
Data inputs/outputs (DQ0-DQ7)
The Data I/O outputs the data stored at the selected address during a Bus Read operation.
During Bus Write operations they represent the commands sent to the command interface
of the internal state machine.
2.3
Data inputs/outputs (DQ8-DQ14)
The Data I/O outputs the data stored at the selected address during a Bus Read operation
when BYTE is High, VIH. When BYTE is Low, VIL, these pins are not used and are high
impedance. During Bus Write operations the Command Register does not use these bits.
When reading the Status Register these bits should be ignored.
2.4
Data inputs/outputs or address inputs (DQ15A−1)
When the device is in x 16 bus mode, this pin behaves as a Data input/output pin (as DQ8DQ14). When the device operates in x 8 bus mode, this pin behaves as the least significant
bit of the address. Throughout the text consider references to the Data input/output to
include this pin when the device operates in x 16 bus mode and references to the Address
inputs to include this pin when the device operates in x 8 bus mode except when stated
explicitly otherwise.
2.5
Chip Enable (E)
The Chip Enable pin, E, activates the memory, allowing Bus Read and Bus Write operations
to be performed. When Chip Enable is High, VIH, all other pins are ignored.
2.6
Output Enable (G)
The Output Enable pin, G, controls the Bus Read operation of the memory.
13/94
Signal descriptions
2.7
M29W128GH, M29W128GL
Write Enable (W)
The Write Enable pin, W, controls the Bus Write operation of the memory’s command
interface.
2.8
VPP/Write Protect (VPP/WP)
The VPP/Write Protect pin provides two functions. The VPPH function allows the memory to
use an external high voltage power supply to reduce the time required for program
operations. This is achieved by bypassing the unlock cycles.
The Write Protect function provides a hardware method of protecting the highest or lowest
block (see Section 1: Description). When VPP/Write Protect is Low, VIL, the highest or lowest
block is protected. Program and Erase operations on this block are ignored while VPP/Write
Protect is Low.
When VPP/Write Protect is High, VIH, the memory reverts to the previous protection status
of the highest or lowest block. Program and Erase operations can now modify the data in
this block unless the block is protected using Block protection.
When VPP/Write Protect is raised to VPPH the memory automatically enters the Unlock
Bypass mode (see Section 6.2.6).
When VPP/Write Protect is raised to VPPH, the execution time of the command is lower (see
Table 17: Program, Erase times and Program, Erase endurance cycles).
When VPP/Write Protect returns to VIH or VIL normal operation resumes. During Unlock
Bypass Program operations the memory draws IPP from the pin to supply the programming
circuits. See the description of the Unlock Bypass command in the command interface
section. The transitions from VIH to VPPH and from VPPH to VIH must be slower than tVHVPP
(see Figure 23: Accelerated program timing waveforms).
Never raise VPP/Write Protect to VPPH from any mode except Read mode, otherwise the
memory may be left in an indeterminate state. A 0.1 µF capacitor should be connected
between the VPP/Write Protect pin and the VSS ground pin to decouple the current surges
from the power supply. The PCB track widths must be sufficient to carry the currents
required during Unlock Bypass Program (see IPP1, IPP2, IPP3, IPP4 in Table 25: DC
characteristics).
The VPP/Write Protect pin may be left floating or unconnected because it features an
internal pull-up.
Refer to Table 3 for a summary of VPP/WP functions.
Table 3.
VPP/WP functions
VPP/WP
VIL
Highest block protected on M29W128GH.
Lowest block protected on M29W128GL.
VIH
Highest and lowest block unprotected unless a software protection is
activated (see Section 4: Hardware protection).
VPPH
14/94
Function
Unlock bypass mode. It supplies the current needed to speed up
programming.
M29W128GH, M29W128GL
2.9
Signal descriptions
Reset (RP)
The Reset pin can be used to apply a Hardware Reset to the memory.
A Hardware Reset is achieved by holding Reset Low, VIL, for at least tPLPX. After Reset goes
High, VIH, the memory will be ready for Bus Read and Bus Write operations after tPHEL or
tRHEL, whichever occurs last. See Section 2.10: Ready/Busy output (RB), Table 29: Reset
AC characteristics, Figure 21 and Figure 22 for more details.
2.10
Ready/Busy output (RB)
The Ready/Busy pin is an open-drain output that can be used to identify when the device is
performing a program or erase operation. During program or erase operations Ready/Busy
is Low, VOL (see Table 20: Status Register bits). Ready/Busy is high-impedance during
Read mode, Auto Select mode and Erase Suspend mode.
After a Hardware Reset, Bus Read and Bus Write operations cannot begin until Ready/Busy
becomes high-impedance. See Table 29: Reset AC characteristics, Figure 21 and
Figure 22.
The use of an open-drain output allows the Ready/Busy pins from several memories to be
connected to a single pull-up resistor. A Low will then indicate that one, or more, of the
memories is busy.
2.11
Byte/word organization select (BYTE)
It is used to switch between the x 8 and x 16 Bus modes of the memory. When Byte/word
organization select is Low, VIL, the memory is in x 8 mode, when it is High, VIH, the memory
is in x 16 mode.
2.12
VCC supply voltage
VCC provides the power supply for all operations (Read, Program and Erase).
The command interface is disabled when the VCC supply voltage is less than the Lockout
voltage, VLKO. This prevents Bus Write operations from accidentally damaging the data
during power-up, power-down and power surges. If the Program/Erase controller is
programming or erasing during this time then the operation aborts and the memory contents
being altered will be invalid.
A 0.1 µF capacitor should be connected between the VCC supply voltage pin and the VSS
ground pin to decouple the current surges from the power supply. The PCB track widths
must be sufficient to carry the currents required during program and erase operations (see
ICC1, ICC2, ICC3 in Table 25: DC characteristics).
2.13
VCCQ input/output supply voltage
VCCQ provides the power supply to the I/O pins and enables all outputs to be powered
independently from VCC.
15/94
Signal descriptions
2.14
M29W128GH, M29W128GL
Vss ground
VSS is the reference for all voltage measurements. The device features two VSS pins both of
which must be connected to the system ground.
16/94
M29W128GH, M29W128GL
3
Bus operations
Bus operations
There are five standard bus operations that control the device. These are Bus Read
(Random and Page modes), Bus Write, Output Disable, Standby and Automatic Standby.
See Table 4: Bus operations, 8-bit mode and Table 5: Bus operations, 16-bit mode for a
summary. Typical glitches of less than 5 ns on Chip Enable, Write Enable, and Reset pins
are ignored by the memory and do not affect bus operations.
3.1
Bus Read
Bus Read operations read from the memory cells, or specific registers in the command
interface. To speed up the read operation the memory array can be read in Page mode
where data is internally read and stored in a page buffer. The page has a size of 8 words (or
16 bytes) and is addressed by the address inputs A2-A0 in x 16 mode and A2-A0 plus
DQ15A−1 in byte mode.
A valid Bus Read operation involves setting the desired address on the Address inputs,
applying a Low signal, VIL, to Chip Enable and Output Enable and keeping Write Enable
High, VIH. The Data inputs/outputs will output the value, see Figure 13: Random Read AC
waveforms (8-bit mode), Figure 15: Page Read AC waveforms (16-bit mode), and Table 26:
Read AC characteristics, for details of when the output becomes valid.
3.2
Bus Write
Bus Write operations write to the command interface. A valid Bus Write operation begins by
setting the desired address on the Address inputs. The Address inputs are latched by the
command interface on the falling edge of Chip Enable or Write Enable, whichever occurs
last. The Data inputs/outputs are latched by the command interface on the rising edge of
Chip Enable or Write Enable, whichever occurs first. Output Enable must remain High, VIH,
during the whole Bus Write operation. See Figure 16, and Figure 17, Write AC waveforms,
and Table 27 and Table 28, Write AC characteristics, for details of the timing requirements.
3.3
Output Disable
The Data inputs/outputs are in the high impedance state when Output Enable is High, VIH.
3.4
Standby
Driving Chip Enable High in Read mode, causes the memory to enter Standby mode and
the data inputs/outputs pins are placed in the high-impedance state. To reduce the Supply
current to the Standby Supply current, ICC2, Chip Enable should be held within VCC ± 0.3 V.
For the Standby current level see Table 25: DC characteristics.
During program or erase operations the memory will continue to use the Program/Erase
Supply current, ICC3, for Program or Erase operations until the operation completes.
17/94
Bus operations
3.5
M29W128GH, M29W128GL
Reset
During Reset mode the memory is deselected and the outputs are high impedance. The
memory is in Reset mode when RP is at VIL. The power consumption is reduced to the
standby level, independently from the Chip Enable, Output Enable or Write Enable inputs.
3.6
Automatic Standby
Automatic Standby allows the memory to achieve low power consumption during Read
mode.
After a read operation, if CMOS levels (VCC ± 0.3 V) are used to drive the bus and the bus is
inactive for tAVQV + 30 ns or more, the memory enters Automatic Standby where the internal
Supply current is reduced to the Standby Supply current, ICC2 (see Table 25: DC
characteristics). The Data inputs/outputs will still output data if a Bus Read operation is in
progress.
The power supplier of data bus, VCCQ, can have a null consumption (depending on load
circuits connected with data bus) when the memory enters Automatic Standby.
3.7
Auto Select mode
The Auto Select mode allows the system or the programming equipment to read the
electronic signature, verify the protection status of the extended memory block, and
apply/remove Block protection. For example, this mode can be used by a programming
equipment to automatically match a device and the application code to be programmed.
There are two methods to enter Auto Select mode:
●
programmer method:
Additional bus operations are used. They require VID to be applied to address pin A9.
Refer to Table 6, Table 7, Table 8, and Table 9 for a description of the bus operations
required to read the electronic signature using the programmer method
●
in-system method:
The Auto Select mode is entered by issuing the Auto Select command (see
Section 6.1.2). It is not necessary to apply VID to A9.
At power-up, the device is in Read mode, and can then be put in Auto Select mode by using
one of the methods described above.
The device cannot enter Auto Select mode when a program or erase operation is ongoing
(RB Low). However, Auto Select mode can be entered if the erase operation has been
suspended by issuing an Erase Suspend command (see Section 6.1.6).
The Auto Select mode is exited by performing a reset. The device is returned to Read mode,
except if the Auto Select mode was entered after an Erase Suspend or a Program Suspend
command. In this case, it returns to the Erase or Program Suspend mode.
3.7.1
Read electronic signature
The memory has two codes, the manufacturer code and the device code used to identify the
memory. These codes can be accessed by performing read operations with control signals
and addresses set as shown in Table 6: Read electronic signature - auto select mode -
18/94
M29W128GH, M29W128GL
Bus operations
programmer method (8-bit mode) and Table 7: Read electronic signature - auto select mode
- programmer method (16-bit mode).
These codes can also be accessed by issuing an Auto Select command (see Section 6.1.2:
Auto Select command).
3.7.2
Verify extended memory block protection indicator
The extended memory block is either factory locked or customer lockable.
The protection status of the extended memory block (factory locked or customer lockable)
can be accessed by reading the extended memory block protection indicator. It can be read
in Auto Select mode using either the programmer (see Table 8 and Table 9) or the in-system
method (see Table 10 and Table 11).
The protection status of the extended memory block is then output on bit DQ7 of the Data
input/outputs (see Table 4 and Table 5, Bus operations in 8-bit and 16-bit mode).
3.7.3
Verify block protection status
The protection status of a block can be directly accessed by performing a read operation
with control signals and addresses set as shown in Table 8 and Table 9.
If the block is protected, then 01h (in x 8 mode) is output on Data input/outputs DQ0-DQ7,
otherwise 00h is output.
3.7.4
Hardware Block Protect
The VPP/WP pin can be used to protect the highest or lowest block. When VPP/WP is at VIL
the highest (M29W128GH) or lowest block (M29W128GL) is protected and remains
protected regardless of the block protection status or the Reset pin state.
19/94
Bus operations
Table 4.
M29W128GH, M29W128GL
M
Bus operations, 8-bit mode
Operation(1)
Bus Read
Address Inputs
E
G
VIL
VIL
W
VIH
RP
Data inputs/outputs
VPP/WP
A22-A0, DQ15A-1
DQ14-DQ8
DQ7-DQ0
VIH
X
Cell address
Hi-Z
Data output
Command address
Hi-Z
Data input(3)
Bus Write
VIL
VIH
VIL
VIH
VIH(2)
Standby
VIH
X
X
VIH
VIH
X
Hi-Z
Hi-Z
Output Disable
VIL
VIH
VIH
VIH
X
X
Hi-Z
Hi-Z
X
X
X
VIL
X
X
Hi-Z
Hi-Z
Reset
1. X = VIL or VIH.
2. If WP is Low, VIL, the outermost block remains protected.
3. Data input as required when issuing a command sequence, performing data polling or block protection.
Table 5.
Bus operations, 16-bit mode
Operation(1)
Bus Read
E
VIL
G
VIL
W
VIH
Address inputs
Data inputs/outputs
A22-A0
DQ15A-1, DQ14-DQ0
RP VPP/WP
VIH
X
Cell address
Data output
Command address
Data input(3)
Bus Write
VIL
VIH
VIL
VIH
VIH(2)
Standby
VIH
X
X
VIH
VIH
X
Hi-Z
Output Disable
VIL
VIH
X
X
Hi-Z
VIL
X
X
Hi-Z
Reset
X
VIH VIH
X
X
1. X = VIL or VIH.
2. If WP is Low, VIL, the outermost block remains protected.
3. Data input as required when issuing a command sequence, performing data polling or block protection.
20/94
M29W128GH, M29W128GL
Table 6.
Bus operations
Read electronic signature - auto select mode - programmer method (8-bit mode)
Address inputs
Read
cycle(1)
E G W
A22-A10 A9
A8A7
A6 A5-A4 A3 A2 A1 A0 DQ15A-1 DQ14-DQ8
Manufacturer
code
Device code
(cycle 1)
Device code
(cycle 2)
VIL VIL VIH
X
VID
(2)
X
Data inputs/outputs
VIL
DQ7-DQ0
VIL VIL VIL VIL
X
X
20h
VIL VIL VIL VIH
X
X
7Eh (both devices)
VIH VIH VIH VIL
X
X
21h (both devices)
VIH VIH VIH VIH
X
X
01h (M29W128GH)
00h (M29W128GL)
X
Device code
(cycle 3)
1. X = VIL or VIH.
2. When using the in-system method, applying VID to A9 is not required. A9 can be either VIL or VIH.
Table 7.
Read electronic signature - auto select mode - programmer method (16-bit mode)
Address inputs
Read
cycle(1)
E
G
Data inputs/outputs
W
A5-A4 A3
A2
A1
A0
DQ15A-1, DQ14-DQ0
Manufacturer
code
VIL
VIL
VIL
VIL
0020h
Device code
(cycle 1)
VIL
VIL
VIL VIH
227Eh
(both devices)
VIH VIH VIH VIL
2221h
(both devices)
VIH VIH VIH VIH
2201h (M29W128GH)
2200h (M29W128GL)
Device code
(cycle 2)
A22-A10 A9 A8-A7
VIL VIL VIH
Device code
(cycle 3)
X
VID
(2)
X
A6
VIL
X
1. X = VIL or VIH.
2. When using the in-system method, applying VID to A9 is not required. A9 can be either VIL or VIH.
21/94
Bus operations
Table 8.
M29W128GH, M29W128GL
Block protection - auto select mode - programmer method (8-bit mode)
Address inputs
Operation(1)
Verify
extended
memory
block
protection
indicator
(bit DQ7)
E
G
W
Data inputs/outputs
DQ15 DQ14
A5- A3A8A22- A14A1 A0
A6
A9
A-1 -DQ8
A4 A2
A7
A16 A10
DQ7-DQ0
89h (factory locked)
09h (customer lockable)
M29W128GL
X
M29W128GH VIL VIL VIH
Verify block protection status
X
VID
(2)
VIH
X
VIL
X
VIL VIH
BAd
X
X
99h (factory locked)
19h (customer lockable)
01h (protected)
00h (unprotected)
VIL
1. X = VIL or VIH. BAd any address in the block.
2. When using the in-system method, applying VID to A9 is not required. A9 can be either VIL or VIH.
Table 9.
Block protection - auto select mode - programmer method (16-bit mode)
Address inputs
Operation(1)
Verify
extended
memory
block
indicator
(bit DQ7)
E
G
W
A22A16
A14A10
A9
A8A6
A7
A5A4
Data inputs/outputs
A3A2
A1
A0
0089h (factory locked)
0009h (customer lockable)
M29W128GL
X
M29W128GH VIL VIL VIH
Verify block protection status
X
BAd
VID
(2)
VIH
X
VIL
X
VIL
VIH
VIL
1. X = VIL or VIH. BAd any address in the block.
2. When using the in-system method, applying VID to A9 is not required. A9 can be either VIL or VIH.
22/94
DQ15A-1, DQ14-DQ0
0099h (factory locked)
0019h (customer lockable)
0001h (protected)
0000h (unprotected)
M29W128GH, M29W128GL
4
Hardware protection
Hardware protection
The M29W128GH and M29W128GL feature a VPP/WP pin that protects the highest or
lowest block. Refer to Section 2: Signal descriptions for a detailed description of the signal.
5
Software protection
The M29W128GH and M29W128GL have three different software protection modes:
●
Volatile protection
●
Non-volatile protection
●
Password protection
On first use all parts default to operate in non-volatile protection mode and the customer is
free to activate the non-volatile or the password protection mode.
The desired protection mode is activated by setting either the one-time programmable Nonvolatile Protection Mode Lock bit, or the Password Protection Mode Lock bit of the Lock
Register (see Section 7.1: Lock Register). Programming the Non-volatile Protection Mode
Lock bit or the Password Protection Mode Lock bit, to ‘0’ will permanently activate the Nonvolatile or the Password Protection mode, respectively. These two bits are one-time
programmable and non-volatile: once the protection mode has been programmed, it cannot
be changed and the device will permanently operate in the selected protection mode. It is
recommended to activate the desired software protection mode when first programming the
device.
The Non-volatile and Password Protection modes both provide non-volatile protection.
Volatilely protected blocks and non-volatilely protected blocks can co-exist within the
memory array. However, the volatile protection only control the protection scheme for blocks
that are not protected using the non-volatile or password protection.
If the user attempts to program or erase a protected block, the device ignores the command
and returns to read mode.
The device is shipped with all blocks unprotected. The block protection status can be read
either by performing a read electronic signature (see Table 6 and Table 7) or by issuing an
Auto Select command (see Table 19: Block protection status).
For the lowest and highest blocks, an even higher level of block protection can be achieved
by locking the blocks using the non-volatile protection and then by holding the VPP/WP pin
Low.
23/94
Software protection
5.1
M29W128GH, M29W128GL
Volatile protection mode
The volatile protection allows the software application to easily protect blocks against
inadvertent change. However, the protection can be easily disabled when changes are
needed. Volatile Protection bits, VPBs, are volatile and unique for each block and can be
individually modified. VPBs only control the protection scheme for unprotected blocks that
have their non-volatile protection bits, NVPBs, cleared (erased to ‘1’) (see Section 5.2: Nonvolatile protection mode and Section 6.3.5: Non-volatile Protection mode command set).
By issuing the VPB Program or VPB Clear commands, the VPBs are set (programmed to
‘0’) or cleared (erased to ‘1’), thus placing each block in the protected or unprotected state
respectively. The VPBs can be set (programmed to ‘0’) or cleared (erased to ‘1’) as often as
needed.
When the parts are first shipped, or after a power-up or hardware reset, the VPBs can be
set or cleared depending upon the ordering option chosen:
●
If the option to clear the VPBs after power-up is selected, then the blocks can be
programmed or erased depending on the NVPBs state (see Table 19: Block protection
status)
●
If the option to set the VPBs after power-up is selected, the blocks default to be
protected.
Refer to Section 6.3.7 for a description of the volatile protection mode command set.
5.2
Non-volatile protection mode
5.2.1
Non-volatile protection bits
A non-volatile protection bit (NVPB) is assigned to each block.
When a NVPB is set to ‘0’, the associated block is protected, preventing any program or
erase operations in this block.
The NVPB bits are set individually by issuing a NVPB Program command. They are nonvolatile and will remain set through a hardware reset or a power-down/power-up sequence.
The NVPBs cannot be cleared individually, they can only be cleared all at the same time by
issuing a Clear all Non-volatile Protection bits command.
The NVPBs can be protected all at a time by setting a volatile bit, the NVPB Lock bit (see
Section 5.2.2: Non-volatile Protection Bit Lock bit).
If one of the non-volatile protected blocks needs to be unprotected (corresponding NVPB
set to ‘1’), a few more steps are required:
Note:
24/94
1.
First, the NVPB Lock bit must be cleared by either putting the device through a power
cycle, or hardware reset
2.
The NVPBs can then be changed to reflect the desired settings
3.
The NVPB Lock bit must be set once again to lock the NVPBs. The device operates
normally again.
1
To achieve the best protection, it is recommended to execute the NVPB Lock Bit Program
command early in the boot code and to protect the boot code by holding VPP/WP Low, VIL.
2
The NVPBs and VPBs have the same function when VPP/WP pin is High, VIH, as they do
when VPP /WP pin is at the voltage for program acceleration (VPPH).
M29W128GH, M29W128GL
Software protection
Refer to Table 19: Block protection status and Figure 5: Software protection scheme for
details on the block protection mechanism, and to Section 6.3.5 for a description of the Nonvolatile Protection mode command set.
5.2.2
Non-volatile Protection Bit Lock bit
The Non-volatile Protection Bit Lock bit (NVPB Lock bit) is a global volatile bit for all blocks.
When set (programmed to ‘0’), it prevents changing the state of the NVPBs. When cleared
(programmed to ‘1’), the NVPBs can be set and reset using the NVPB Program command
and Clear all NVPBs command, respectively.
There is only one NVPB Lock bit per device.
Refer to Section 6.3.6 for a description of the NVPB Lock bit command set.
Note:
5.3
1
No software command unlocks this bit unless the device is in password protection mode; it
can be cleared only by taking the device through a hardware reset or a power-up.
2
The NVPB Lock bit must be set (programmed to ‘0’) only after all NVPBs are configured to
the desired settings.
Password protection mode
The password protection mode provides an even higher level of security than the Nonvolatile Protection mode by requiring a 64-bit password for unlocking the device NVPB Lock
bit.
In addition to this password requirement, the NVPB Lock bit is set ‘0’ after power-up and
reset to maintain the device in password protection mode. Successful execution of the
Password Unlock command by entering the correct password clears the NVPB Lock bit,
allowing for block NVPBs to be modified.
If the password provided is not correct, the NVPL Lock bit remains locked and the state of
the NVPBs cannot be modified.
To place the device in password protection mode, the following steps are required:
1.
Prior to entering the password protection mode, it is necessary to set a 64-bit password
and to verify it (see Password Program command and Password Read command).
Password verification is only allowed during the password programming operation
2.
The password protection mode is then activated by programming the Password
Protection Mode Lock bit to ‘0’. This operation is not reversible and once the bit is
programmed it cannot be erased, the device permanently remains in password
protection mode, and the 64-bit password can neither be retrieved nor reprogrammed.
Moreover, all commands to the address where the password is stored, are disabled.
Refer to Table 19: Block protection status and Figure 5: Software protection scheme for
details on the block protection scheme.
Refer to Section 6.3.4 for a description of the Password Protection mode command set.
Note:
There is no means to verify the password after it is set. If the password is lost after setting
the Password Mode Lock bit, there is no way to clear the NVPB Lock bit.
25/94
Software protection
Figure 5.
M29W128GH, M29W128GL
Software protection scheme
VPB(2)
Parameter block or
main block
Volatile protection
NVPB(1)
NVPB Lock bit(3)
Non-volatile protection
Non-volatile
protection mode
Password protection
mode
AI13676
1. NVPBs default to ‘1’ (block unprotected) after power-up and hardware reset. A block is protected or unprotected when its
NVPB is set to ‘0’ and ‘1’, respectively. NVPBs are programmed individually and cleared collectively.
2. VPB default status depends on ordering option. A block is protected or unprotected when its VPB is set to ‘0’ and ‘1’,
respectively. VPBs are programmed and cleared individually. For the volatile protection to be effective, the NVPB Lock bit
must be set to ‘0’ (NVPB bits unlocked) and the block NVPB must be set to ‘1’ (block unprotected).
3. The NVPB Lock bit is volatile and default to ‘1’ (NVPB bits unlocked) after power-up and hardware reset. NVPB bits are
locked by setting the NVPB Lock bit to ‘0’. Once programmed to ‘0’, the NVPB Lock bit can be reset to ‘1’ only be taking the
device through a power-up or hardware reset.
26/94
M29W128GH, M29W128GL
6
Command interface
Command interface
All Bus Write operations to the memory are interpreted by the command interface.
Commands consist of one or more sequential Bus Write operations. Failure to observe a
valid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The address used for the commands changes depending on whether the memory is in 16bit or 8-bit mode.
6.1
Standard commands
See either Table 10, or Table 11, depending on the configuration that is being used, for a
summary of the standard commands.
6.1.1
Read/Reset command
The device is in Read mode after reset or after power-up.
The Read/Reset command returns the memory to Read mode. It also resets the errors in
the Status Register. Either one or three Bus Write operations can be used to issue the
Read/Reset command.
The Read/Reset command can be issued, between Bus Write cycles before the start of a
program or erase operation, to return the device to Read mode. If the Read/Reset command
is issued during the timeout of a Block erase operation, the memory will take up to 10 µs to
abort. During the abort period no valid data can be read from the memory.
The Read/Reset command will not abort an Erase operation when issued while in Erase
Suspend.
6.1.2
Auto Select command
The Auto Select command puts the device in Auto Select mode, when using the in-system
method (see Section 3.7: Auto Select mode). When in Auto Select mode, the system can
read the manufacturer code, the device code, the protection status of each block (Block
Protection status) and the extended memory block protection indicator.
Three consecutive Bus Write operations are required to issue the Auto Select command.
Once the Auto Select command is issued Bus Read operations to specific addresses output
the manufacturer code, the device code, the extended memory block protection indicator
and a block protection status (see Table 10 and Table 11 in conjunction with Table 6,
Table 7, Table 8, and Table 9). The memory remains in Auto Select mode until a Read/Reset
or CFI Query command is issued.
27/94
Command interface
6.1.3
M29W128GH, M29W128GL
Read CFI Query command
The memory contains an information area, named CFI data structure, which contains a
description of various electrical and timing parameters, density information and functions
supported by the memory. See Appendix B, Table 35, Table 36, Table 37, Table 38, Table 39
and Table 40 for details on the information contained in the common Flash interface (CFI)
memory area.
The Read CFI Query command is used to put the memory in Read CFI Query mode. Once
in Read CFI Query mode, Bus Read operations to the memory will output data from the
common Flash interface (CFI) memory area. One Bus Write cycle is required to issue the
Read CFI Query command. This command is valid only when the device is in the Read
Array or Auto Select mode.
The Read/Reset command must be issued to return the device to the previous mode (the
Read Array mode or Auto Select mode). A second Read/Reset command is required to put
the device in Read Array mode from Auto Select mode.
6.1.4
Chip Erase command
The Chip Erase command can be used to erase the entire chip. Six Bus Write operations
are required to issue the Chip Erase command and start the Program/Erase controller.
If some block are protected, then these are ignored and all the other blocks are erased. If all
of the blocks are protected the Chip Erase operation appears to start but will terminate
within about 100 µs, leaving the data unchanged. No error condition is given when protected
blocks are ignored.
During the Erase operation the memory will ignore all commands, including the Erase
Suspend command. It is not possible to issue any command to abort the operation. Typical
Chip Erase times are given in Table 17. All Bus Read operations during the Chip Erase
operation will output the Status Register on the Data inputs/outputs. See Section 7.2: Status
Register for more details.
After the Chip Erase operation has completed the memory will return to the Read mode,
unless an error has occurred. When an error occurs the memory will continue to output the
Status Register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
The Chip Erase command sets all of the bits in unprotected blocks of the memory to ’1’. All
previous data is lost.
The Chip Erase operation is aborted by performing a reset or powering down the device. In
this case, data integrity cannot be ensured, and it is recommended to erase again the entire
chip.
6.1.5
Block Erase command
The Block Erase command can be used to erase a list of one or more blocks. It sets all of
the bits in the unprotected selected blocks to ’1’. All previous data in the selected blocks is
lost.
Six Bus Write operations are required to select the first block in the list. Each additional
block in the list can be selected by repeating the sixth Bus Write operation using the address
of the additional block. After the command sequence is written, a Block Erase timeout
occurs. During the timeout period, additional sector addresses and sector erase commands
may be written. Once the Program/Erase controller has started, it is not possible to select
28/94
M29W128GH, M29W128GL
Command interface
any more blocks. Each additional block must therefore be selected within the timeout period
of the last block. The timeout timer restarts when an additional block is selected. After the
sixth Bus Write operation, a Bus Read operation outputs the Status Register. See Figure 16:
Write Enable Controlled Program waveforms (8-bit mode) and Figure 17: Write Enable
Controlled Program waveforms (16-bit mode) for details on how to identify if the
Program/Erase controller has started the Block Erase operation.
After the Block Erase operation has completed, the memory returns to the Read mode,
unless an error has occurred. When an error occurs, Bus Read operations will continue to
output the Status Register. A Read/Reset command must be issued to reset the error
condition and return to Read mode.
If any selected blocks are protected then these are ignored and all the other selected blocks
are erased. If all of the selected blocks are protected the Block Erase operation appears to
start but will terminate within about 100 µs, leaving the data unchanged. No error condition
is given when protected blocks are ignored.
During the Block Erase operation the memory ignores all commands except the Erase
Suspend command and the Read/Reset command which is only accepted during the
timeout period. Typical Block Erase time and Block Erase timeout are given in Table 17.
The Block Erase operation is aborted by performing a reset or powering down the device. In
this case, data integrity cannot be ensured, and it is recommended to erase again the blocks
aborted.
6.1.6
Erase Suspend command
The Erase Suspend command can be used to temporarily suspend a Block Erase operation.
One Bus Write operation is required to issue the command together with the block address.
After the command sequence is written, a minimum Block Erase timeout occurs (see
Section 6.1.6: Erase Suspend command). During the timeout period, additional block
addresses and block erase commands can be written.
The Program/Erase controller suspends the erase operation within the Erase Suspend
Latency time of the Erase Suspend command being issued. However, when the Erase
Suspend command is written during the Block Erase timeout, the device immediately
terminates the timeout period and suspends the erase operation.
Once the Program/Erase controller has stopped, the memory operates in Read mode and
the Erase is suspended.
During Erase Suspend it is possible to read and execute Program or Write to Buffer Program
operations in blocks that are not suspended; both read and program operations behave as
normal on these blocks. Reading from blocks that are suspended will output the Status
Register. If any attempt is made to program in a protected block or in the suspended block
then the Program command is ignored and the data remains unchanged. In this case the
Status Register is not read and no error condition is given.
It is also possible to issue the Auto Select, Read CFI Query and Unlock Bypass commands
during an Erase Suspend. The Read/Reset command must be issued to return the device to
Read Array mode before the Resume command will be accepted.
During Erase Suspend a Bus Read operation to the extended memory block will output the
extended memory block data. Once in the Extended Block mode, the Exit Extended Block
command must be issued before the erase operation can be resumed.
The Erase Suspend command is ignored if written during Chip Erase operations.
29/94
Command interface
M29W128GH, M29W128GL
Refer to Table 17: Program, Erase times and Program, Erase endurance cycles for the
values of Block Erase timeout and Block Erase Suspend latency time.
If the Erase Suspend operation is aborted by performing a reset or powering down the
device, data integrity cannot be ensured, and it is recommended to erase again the blocks
suspended.
6.1.7
Erase Resume command
The Erase Resume command is used to restart the Program/Erase controller after an Erase
Suspend.
The device must be in Read Array mode before the Resume command will be accepted. An
erase can be suspended and resumed more than once.
6.1.8
Program Suspend command
The Program Suspend command allows the system to interrupt a program operation so that
data can be read from any block. When the Program Suspend command is issued during a
program operation, the device suspends the program operation within the Program Suspend
latency time (see Table 17: Program, Erase times and Program, Erase endurance cycles)
and updates the Status Register bits.
After the program operation has been suspended, the system can read array data from any
address. However, data read from program-suspended addresses is not valid.
The Program Suspend command may also be issued during a program operation while an
erase is suspended. In this case, data may be read from any addresses not in Erase
Suspend or Program Suspend. If a read is needed from the extended memory block area
(one-time program area), the user must use the proper command sequences to enter and
exit this region.
The system may also issue the Auto Select command sequence when the device is in the
Program Suspend mode. The system can read as many Auto Select codes as required.
When the device exits the Auto Select mode, the device reverts to the Program Suspend
mode, and is ready for another valid operation. See Auto Select command sequence for
more information.
If the Program Suspend operation is aborted by performing a reset or powering down the
device, data integrity cannot be ensured, and it is recommended to program again the words
or bytes aborted.
6.1.9
Program Resume command
After the Program Resume command is issued, the device reverts to programming. The
controller can determine the status of the program operation using the DQ7 or DQ6 status
bits, just as in the standard program operation. Refer to Figure 16: Write Enable Controlled
Program waveforms (8-bit mode) and Figure 17: Write Enable Controlled Program
waveforms (16-bit mode) for details.
The system must issue a Program Resume command, to exit the Program Suspend mode
and to continue the programming operation.
Further issuing of the Resume command is ignored. Another Program Suspend command
can be written after the device has resumed programming.
30/94
M29W128GH, M29W128GL
6.1.10
Command interface
Program command
The Program command can be used to program a value to one address in the memory array
at a time. The command requires four Bus Write operations, the final write operation latches
the address and data in the internal state machine and starts the Program/Erase controller.
Programming can be suspended and then resumed by issuing a Program Suspend
command and a Program Resume command, respectively (see Section 6.1.8: Program
Suspend command and Section 6.1.9: Program Resume command).
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status Register is never read and no error condition is given.
After programming has started, Bus Read operations output the Status Register content.
See Figure 16: Write Enable Controlled Program waveforms (8-bit mode) and Figure 17:
Write Enable Controlled Program waveforms (16-bit mode) for more details. Typical program
times are given in Table 17: Program, Erase times and Program, Erase endurance cycles.
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs, Bus Read operations to the memory continue
to output the Status Register. A Read/Reset command must be issued to reset the error
condition and return to Read mode.
One of the Erase commands must be used to set all the bits in a block or in the whole
memory from ’0’ to ’1’.
The Program operation is aborted by performing a reset or powering-down the device. In
this case data integrity cannot be ensured, and it is recommended to reprogram the word or
byte aborted.
31/94
Command interface
Table 10.
M29W128GH, M29W128GL
Standard commands, 8-bit mode
Command
Length
Bus operations(1)
1st
Add
2nd
Data Add Data
3rd
Add
4th
5th
6th
Data Add Data Add Data Add Data
1
X
F0
3
AAA
AA
555
55
X
F0
3
AAA
AA
555
55
AAA
90
(2)(3)
(2)(3)
Program(4)
4
AAA
AA
555
55
AAA
A0
PA
PD
Chip Erase
6
AAA
AA
555
55
AAA
80
AAA
AA
555
55
AAA
10
Block Erase
6+
AAA
AA
555
55
AAA
80
AAA
AA
555
55
BAd
30
Erase/Program Suspend
1
X
B0
Erase/Program Resume
1
X
30
Read CFI Query
1
AA
98
Read/Reset
Manufacturer code
Device code
Auto
Select
Extended memory
block protection
indicator
Block protection
status
1. X Don’t care, PA Program Address, PD Program Data, BAd Any address in the Block. All values in the table are in
hexadecimal.
2. These cells represent Read cycles. The other cells are Write cycles.
3. The Auto Select addresses and data are given in Table 6: Read electronic signature - auto select mode - programmer
method (8-bit mode), and Table 8: Block protection - auto select mode - programmer method (8-bit mode), except for A9
that is ‘Don’t care’.
4. In Unlock Bypass, the first two unlock cycles are no more needed (see Table 12: Fast Program commands, 8-bit mode and
Table 13: Fast Program commands, 16-bit mode).
32/94
M29W128GH, M29W128GL
Table 11.
Command interface
Standard commands, 16-bit mode
Command
Length
Bus operations(1)
1st
Add
2nd
Data Add Data
3rd
Add
4th
5th
6th
Data Add Data Add Data Add Data
1
X
F0
3
555
AA
2AA
55
X
F0
3
555
AA
2AA
55
555
90
(2)(3)
(2)(3)
Program(4)
4
555
AA
2AA
55
555
A0
PA
PD
Chip Erase
6
555
AA
2AA
55
555
80
555
AA
2AA
55
555
10
Block Erase
6+
555
AA
2AA
55
555
80
555
AA
2AA
55
BAd
30
Erase/Program Suspend
1
X
B0
Erase/Program Resume
1
X
30
Read CFI Query
1
55
98
Read/Reset
Manufacturer code
Device code
Extended memory
Auto
Select block protection
indicator
Block protection
status
1. X Don’t care, PA Program Address, PD Program Data, BAd any address in the Block. All values in the table are in
hexadecimal.
2. These cells represent Read cycles. The other cells are Write cycles.
3. The Auto Select addresses and data are given in Table 7: Read electronic signature - auto select mode - programmer
method (16-bit mode), and Table 9: Block protection - auto select mode - programmer method (16-bit mode), except for A9
that is ‘Don’t care’.
4. In Unlock Bypass, the first two unlock cycles are no more needed (see Table 12 and Table 13 Fast Program commands, 8bit and 16-bit mode).
33/94
Command interface
6.2
M29W128GH, M29W128GL
Fast Program commands
The M29W128GH/L offers a set of Fast Program commands to improve the programming
throughput:
●
Write to Buffer Program
●
Enhanced Buffered Program (valid in x 16 mode only)
●
Unlock Bypass.
See either Table 12, Table 13 or Table 14 depending on the configuration that is being used,
for a summary of the Fast Program commands.
When VPPH is applied to the VPP/Write Protect pin the memory automatically enters Unlock
Bypass mode (see Section 6.2.6: Unlock Bypass command).
After programming has started, Bus Read operations in the memory output the Status
Register content. Write to Buffer Program command can be suspended and then resumed
by issuing a Program Suspend command and a Program Resume command, respectively
(see Section 6.1.8: Program Suspend command and Section 6.1.9: Program Resume
command).
After the fast program operation has completed, the memory will return to the Read mode,
unless an error has occurred. When an error occurs Bus Read operations to the memory
will continue to output the Status Register. A Read/Reset command must be issued to reset
the error condition and return to Read mode. One of the Erase commands must be used to
set all the bits in a block or in the whole memory from ’0’ to ’1’.
Typical program times are given in Table 17: Program, Erase times and Program, Erase
endurance cycles.
6.2.1
Write to Buffer Program command
The Write to Buffer Program command makes use of the device’s 32-word/64-byte write
buffer to speed up programming. 32 words/64 bytes can be loaded into the write buffer.
Each write buffer has the same A22-A5 addresses.The Write to Buffer Program command
dramatically reduces system programming time compared to the standard non-buffered
Program command.
When issuing a Write to Buffer Program command, the VPP/WP pin can be either held High,
VIH, or raised to VPPH.
See Table 17 for details on typical Write to Buffer Program times in both cases.
Five successive steps are required to issue the Write to Buffer Program command:
34/94
1.
The Write to Buffer Program command starts with two unlock cycles
2.
The third Bus Write cycle sets up the Write to Buffer Program command. The setup
code can be addressed to any location within the targeted block
3.
The fourth Bus Write cycle sets up the number of words/bytes to be programmed.
Value N is written to the same block address, where N+1 is the number of words/bytes
to be programmed. N+1 must not exceed the size of the write buffer or the operation
will abort
4.
The fifth cycle loads the first address and data to be programmed
5.
Use N Bus Write cycles to load the address and data for each word/byte into the write
buffer. Addresses must lie within the range from the start address+1 to the start
address + N-1. Optimum performance is obtained when the start address corresponds
M29W128GH, M29W128GL
Command interface
to a 32-word/64-byte boundary. If the start address is not aligned to a 32-word/64-byte
boundary, the total programming time is doubled.
All the addresses used in the Write to Buffer Program operation must lie within the same
page.
To program the content of the write buffer, this command must be followed by a Write to
Buffer Program Confirm command.
If an address is written several times during a Write to Buffer Program operation, the
address/data counter will be decremented at each data load operation and the data will be
programmed to the last word loaded into the buffer.
Invalid address combinations or failing to follow the correct sequence of Bus Write cycles
will abort the Write to Buffer Program.
The Status Register bits DQ1, DQ5, DQ6, DQ7 can be used to monitor the device status
during a Write to Buffer Program operation.
It is possible to detect Program operation fails when changing programmed data from ‘0’ to
‘1’, that is when reprogramming data in a portion of memory already programmed. The
resulting data will be the logical OR between the previous value and the current value.
See Appendix D, Figure 28: Write to Buffer Program flowchart and pseudocode, for a
suggested flowchart on using the Write to Buffer Program command.
6.2.2
Enhanced Buffered Program command
The Enhanced Buffered Program command, available only in x 16 mode, makes use of the
device’s 256-word write buffer to speed up programming. 256 words can be loaded into the
write buffer. Each write buffer has the same A22-A8 addresses. The Enhanced Buffered
Program command dramatically reduces system programming time compared to both the
standard non-buffered Program command and the Write to Buffer command.
When issuing an Enhanced Buffered Program command, the VPP/WP pin can be either held
High, VIH, or raised to VPPH.
See Table 17: Program, Erase times and Program, Erase endurance cycles for details on
typical Enhanced Buffered Program times in both cases.
Three successive steps are required to issue the Enhanced Buffered Program command:
●
The Enhanced Buffered Program command starts with two unlock cycles
●
The third Bus Write cycle sets up the Enhanced Buffered Program command. The
setup code can be addressed to any location within the targeted block
●
The fourth Bus Write cycle loads the first address and data to be programmed. There a
total of 256 address and data loading cycles.
To program the content of the write buffer, the Enhanced Buffered Program command must
be followed by an Enhanced Buffered Program Confirm command. The command ends with
an internal Enhanced Buffered Program Confirm cycle.
Note that address/data cycles must be loaded in an increasing address order (from
ADD[7:0]=00000000 to ADD[7:0]=11111111) and completely (all 256 words). Invalid
address combinations or failing to follow the correct sequence of Bus Write cycles will abort
the Enhanced Buffered Program.
The Status Register bits DQ1, DQ5, DQ6, and DQ7 can be used to monitor the device
status during an Enhanced Buffered Program operation.
35/94
Command interface
M29W128GH, M29W128GL
An external supply (12 V) can be used to improve programming efficiency.
It is possible to detect Program operation fails when changing programmed data from ‘0’ to
‘1’, that is when reprogramming data in a portion of memory already programmed. The
resulting data will be the logical OR between the previous and the current value.
See Appendix D and Figure 29: Enhanced Buffered Program flowchart and pseudocode, for
a suggested flowchart on using the Enhanced Buffered Program command.
6.2.3
Buffered Program Abort and Reset command
A Buffered Program Abort and Reset command must be issued to abort the Write to Buffer
Program and Enhanced Buffered Program operation and reset the device in Read mode.
The write to buffer and enhanced buffered programming sequence can be aborted in the
following ways:
●
Load a value that is greater than the page buffer size during the number of locations to
program step in the Write to Buffer Program command
●
Write to an address in a block different than the one specified during the write-bufferload command
●
Write an address/data pair to a different write-buffer-page than the one selected by the
starting address during the write buffer data loading stage of the operation
●
Write data other than the Confirm command after the specified number of data load
cycles
●
Load address/data pairs in an incorrect sequence during the enhanced buffered
program.
The abort condition is indicated by DQ1 = 1, DQ7 = DQ7 (for the last address location
loaded), DQ6 = toggle, and DQ5 = 0 (all of which are Status Register bits). A Buffered
Program Abort and Reset command sequence must be written to reset the device for the
next operation. Note that the full 3-cycle Buffered Program Abort and Reset command
sequence is required when using write to buffer and enhanced buffered programming
features in Unlock Bypass mode.
Note:
36/94
Enhanced Buffered Program commands are available for x 16 mode only.
M29W128GH, M29W128GL
6.2.4
Command interface
Write to Buffer Program Confirm command
The Write to Buffer Program Confirm command is used to confirm a Write to Buffer Program
command and to program the N+1 words/bytes loaded in the write buffer by this command.
6.2.5
Enhanced Buffered Program Confirm command
The Enhanced Buffered Program Confirm command is used to confirm an Enhanced
Buffered Program command and to program the 256 words loaded in the buffer.
6.2.6
Unlock Bypass command
The Unlock Bypass command is used to place the device in Unlock Bypass mode. When the
device enters the Unlock Bypass mode, the two initial unlock cycles required in the standard
program command sequence are no more needed, and only two write cycles are required to
program data, instead of the normal four cycles (see Note 4 below Table 10 and Table 11).
This results in a faster total programming time.
Unlock Bypass command is consequently used in conjunction with the Unlock Bypass
Program command to program the memory faster than with the standard program
commands. When the cycle time to the device is long, considerable time saving can be
made by using these commands. Three Bus Write operations are required to issue the
Unlock Bypass command.
When in Unlock Bypass mode, only the Unlock Bypass Program, Unlock Bypass Block
Erase, Unlock Bypass Chip Erase, and Unlock Bypass Reset commands are valid:
●
The Unlock Bypass Program command can be issued to program addresses within the
memory
●
The Unlock Bypass Block Erase command can then be issued to erase one or more
memory blocks
●
The Unlock Bypass Chip Erase command can be issued to erase the whole memory
array
●
The Unlock Bypass Write to Buffer Program command can be issued to speed up
programming operation
●
The Unlock Bypass Enhanced Buffered Program command can be issued to speed up
programming operation
●
The Unlock Bypass Reset command can be issued to return the memory to Read
mode.
In Unlock Bypass mode the memory can be read as if in Read mode.
6.2.7
Unlock Bypass Program command
The Unlock Bypass Program command can be used to program one address in the memory
array at a time. The command requires two Bus Write operations, the final write operation
latches the address and data and starts the Program/Erase controller.
The Program operation using the Unlock Bypass Program command behaves identically to
the Program operation using the Program command. The operation cannot be aborted, a
Bus Read operation to the memory outputs the Status Register. See the Program command
for details on the behavior.
37/94
Command interface
6.2.8
M29W128GH, M29W128GL
Unlock Bypass Block Erase command
The Unlock Bypass Block Erase command can be used to Erase one or more memory
blocks at a time. The command requires two Bus Write operations instead of six using the
standard Block Erase command. The final Bus Write operation latches the address of the
block and starts the Program/Erase controller.
To erase multiple block (after the first two Bus Write operations have selected the first block
in the list), each additional block in the list can be selected by repeating the second Bus
Write operation using the address of the additional block.
The Unlock Bypass Block Erase command behaves in the same way as the Block Erase
command: the operation cannot be aborted, and a Bus Read operation to the memory
outputs the Status Register (see Section 6.1.5: Block Erase command for details).
6.2.9
Unlock Bypass Chip Erase command
The Unlock Bypass Chip Erase command can be used to erase all memory blocks at a time.
The command requires two Bus Write operations only instead of six using the standard Chip
Erase command. The final Bus Write operation starts the Program/Erase controller.
The Unlock Bypass Chip Erase command behaves in the same way as the Chip Erase
command: the operation cannot be aborted, and a Bus Read operation to the memory
outputs the Status Register (see Section 6.1.4: Chip Erase command for details).
6.2.10
Unlock Bypass Write to Buffer Program command
The Unlock Bypass Write to Buffer command can be used to program the memory in Fast
Program mode. The command requires two Bus Write operations less than the standard
Write to Buffer Program command.
The Unlock Bypass Write to Buffer Program command behaves in the same way as the
Write to Buffer Program command: the operation cannot be aborted and a Bus Read
operation to the memory outputs the Status Register (see Section 6.2.1: Write to Buffer
Program command for details).
The Write to Buffer Program Confirm command is used to confirm an Unlock Bypass Write
to Buffer Program command and to program the N+1 words/bytes loaded in the write buffer
by this command.
6.2.11
Unlock Bypass Enhanced Buffered Program command
The Unlock Bypass Enhanced Buffered Program command can be used to program the
memory in Fast Program mode. The command requires two address/data loading cycles
less than the standard Enhanced Buffered Program command (see Table 14: Enhanced
Buffered Program commands, 16-bit mode).
The Unlock Bypass Enhanced Buffered Program command behaves identically to the
Enhanced Buffered Program operation using the Enhanced Buffered Program command.
The operation cannot be aborted and a Bus Read operation to the memory outputs the
Status Register (see Section 6.2.2: Enhanced Buffered Program command for details on the
behavior).
The Enhanced Buffered Program Confirm command is used to confirm an Unlock Bypass
Enhanced Buffered Program command and to program the 256 words loaded in the buffer.
38/94
M29W128GH, M29W128GL
6.2.12
Command interface
Unlock Bypass Reset command
The Unlock Bypass Reset command can be used to return to Read/Reset mode from
Unlock Bypass mode. Two Bus Write operations are required to issue the Unlock Bypass
Reset command. Read/Reset command does not exit from Unlock Bypass mode.
39/94
Command interface
Command
Fast Program commands, 8-bit mode
Bus Write operations(1)
Length
Table 12.
1st
Add
Write to
Buffer
Program
M29W128GH, M29W128GL
N+5 AAA
Write to
Buffer
Program
Confirm
1
Buffered
Program
Abort and
Reset
BAd
2nd
Data Add
AA
3rd
4th
Add
Data
Add
Data
Add
Data
555
55
BAd
25
BAd
N(2)
PA(3)
PD
29
3
AAA
AA
555
55
AAA
F0
Unlock
Bypass
3
AAA
AA
555
55
AAA
20
Unlock
Bypass
Program
2
X
A0
PA
PD
Unlock
Bypass
Block
Erase
2+
X
80
BAd
30
Unlock
Bypass
Chip Erase
2
X
80
X
10
N+3
BAd
25
BAd
N(2)
2
X
90
X
00
Unlock
Bypass
Reset
6th
Data
(5)
Unlock
Bypass
Write to
Buffer
Program
5th
PA
(3)
PD
WBL
(6)
Add
7th
Data
WBL
(4)
8th
9th
Add Data Add Data Add
Data
PD
PD
1.
X Don’t care, PA Program Address, PD Program Data, BAd Any address in the Block, WBL Write Buffer Location. All values in the table are in
hexadecimal.
2.
The maximum number of cycles in the command sequence is 68. N+1 is the number of bytes to be programmed during the Write to Buffer
Program operation.
3.
Each buffer has the same A22-A5 addresses. A0-A4 and A-1 are used to select a byte within the N+1 byte page.
4.
The 6th cycle has to be issued N time. WBL scans the word inside the page.
5.
BAd must be identical to the address loaded during the Write to Buffer Program 3rd and 4th cycles.
6. The 4th cycle has to be issued N time. WBL scans the word inside the page.
40/94
M29W128GH, M29W128GL
Table 13.
Command interface
Fast Program commands, 16-bit mode
Length
Bus Write operations(1)
Command
Write to Buffer
Program
N+5
Write to Buffer
Program Confirm
1
Buffered Program
Abort and Reset
1st
2nd
3rd
4th
5th
6th
Add
Data
Add
Data
Add
Data
Add
Data
Add
Data
555
AA
2AA
55
BAd
25
BAd
N(2)
PA(3)
PD
BAd
(5)
29
3
555
AA
2AA
55
555
F0
Unlock Bypass
3
555
AA
2AA
55
555
20
Unlock Bypass
Program
2
X
A0
PA
PD
Unlock Bypass
Block Erase
2+
X
80
BAd
30
Unlock Bypass
Chip Erase
2
X
80
X
10
Unlock Bypass
Write to Buffer
Program
N+3
BAd
25
BAd
N(2)
Unlock Bypass
Reset
2
X
90
X
00
PA
PD
(3)
WBL
(6)
Add
Data
WBL
PD
(4)
PD
1. X Don’t care, PA Program Address, PD Program Data, BAd Any address in the Block, WBL Write Buffer Location. All
values in the table are in hexadecimal.
2. The maximum number of cycles in the command sequence is 36. N+1 is the number of words to be
programmed during the Write to Buffer Program operation.
3. Each buffer has the same A22-A5 addresses. A0-A4 are used to select a word within the N+1 word page.
4. The 6th cycle has to be issued N time. WBL scans the word inside the page.
5. BAd must be identical to the address loaded during the Write to Buffer Program 3rd and 4th cycles.
Enhanced Buffered Program commands, 16-bit mode(1)
Table 14.
Command
Length
Bus Write operations
1st
2nd
3rd
Add
Data
Add
2AA
55
BAd
(00)
Data
Enhanced
Buffered
Program
259
555
AA
Enhanced
Buffered
Program
Confirm
1
BAd
(00)
29
Unlock
Bypass
Enhanced
Buffered
Program
257
BAd
33
4th
Data Add Data Add Data
BAd
33
BAd
(00)
Data
...
257th
Add
Data
...
...
Add
BAd
(FF)
Data
258th
Add
Data
259th
Add
Data
BAd
(FF)
Data
260th
Add
Data
Data
1. Only available from week 8 of 2008.
41/94
Command interface
6.3
M29W128GH, M29W128GL
Protection commands
Blocks can be protected individually against accidental program, erase or read operations.
The device block protection scheme is shown in Figure 5: Software protection scheme. See
either Table 15, or Table 16, depending on the configuration that is being used, for a
summary of the Block Protection commands.
Block protection commands are available both in 8-bit and 16-bit configuration.
The memory block and Extended Memory block protection is configured through the Lock
register (see Section 7.1: Lock Register).
6.3.1
Enter Extended Memory Block command
The M29W128GH/L has one extra 128-word block (extended memory block) that can only
be accessed using the Enter Extended Memory Block command.
Three Bus Write cycles are required to issue the Extended Memory Block command. Once
the command has been issued the device enters the Extended Memory Block mode where
all Bus Read or Program operations are conducted on the extended memory block. Once
the device is in the Extended Block mode, the extended memory block is addressed by
using the addresses occupied by block 0 in the other operating modes (see Table 34: Block
addresses).
The device remains in Extended Memory Block mode until the Exit Extended Memory Block
command is issued or power is removed from the device. After power-up or a hardware
reset, the device reverts to the Read mode, and the commands issued to block 0 addresses
will properly address block 0.
The extended memory block cannot be erased, and can be treated as one-time
programmable (OTP) memory.
In Extended Block mode, Erase, Chip Erase, Erase Suspend and Erase Resume
commands are not allowed.
To exit from the Extended Memory Block mode the Exit Extended Memory Block command
must be issued.
The Extended Memory Block can be protected by setting the Extended Memory Block
Protection bit to ‘1’ (see Section 7.1: Lock Register); however once protected the protection
cannot be undone.
Note:
When the device is in the Extended Memory Block mode, the VPP/WP pin cannot be used
for fast programming and the Unlock Bypass mode is not available (see Section 2.8:
VPP/Write Protect (VPP/WP)).
6.3.2
Exit Extended Memory Block command
The Exit Extended Memory Block command is used to exit from the Extended Memory
Block mode and return the device to Read mode. Four Bus Write operations are required to
issue the command.
42/94
M29W128GH, M29W128GL
6.3.3
Command interface
Lock Register command set
The M29W128GL and M29W128GH offer a set of commands to access the Lock Register
and to configure and verify its content. See the following sections in conjunction with
Section 7.1: Lock Register, Table 15 and Table 16.
Enter Lock Register Command Set command
Three Bus Write cycles are required to issue the Enter Lock Register Command Set
command. Once the command has been issued, all Bus Read or Program operations are
issued to the Lock Register.
Lock Register Program and Lock Register Read command
The Lock Register Program command allows to configure the Lock Register. The
programmed data can then be checked by issuing a Lock Register Read command.
An Exit Protection Command Set command must then be issued to return the device to
Read mode (see Section 6.3.8: Exit Protection command set).
6.3.4
Password Protection mode command set
Enter Password Protection Command Set command
Three Bus Write cycles are required to issue the Enter Password Protection Command Set
command. Once the command has been issued, the commands related to the Password
Protection mode can be issued to the device.
Password Program command
The Password Program command is used to program the 64-bit password used in the
Password Protection mode.
To program the 64-bit password, the complete command sequence must be entered eight
times at eight consecutive addresses selected by A1-A0 plus DQ15A-1 in 8-bit mode, or four
times at four consecutive addresses selected by A1-A0 in 16-bit mode.
The password can be checked by issuing a Password Read command.
Once Password Program operation has completed, an Exit Protection Command Set
command must be issued to return the device to Read mode. The Password Protection
mode can then be selected.
By default, all Password bits are set to ‘1’.
Password Read command
The Password Read command is used to verify the Password used in Password Protection
mode.
To verify the 64-bit password, the complete command sequence must be entered eight
times at eight consecutive addresses selected by A1-A0 plus DQ15A-1 in 8-bit mode, or four
times at four consecutive addresses selected by A1-A0 in 16-bit mode.
If the Password Mode Lock bit is programmed and the user attempts to read the password,
the device will output FFh onto the I/O data bus.
An Exit Protection Command Set command must be issued to return the device to Read
mode.
43/94
Command interface
M29W128GH, M29W128GL
Password Unlock command
The Password Unlock command is used to clear the NVPB Lock bit allowing to modify the
NVPBs.
The Password Unlock command must be issued along with the correct password.
There must be a 1 µs delay between successive Password Unlock commands in order to
prevent hackers from cracking the password by trying all possible 64-bit combinations. If this
delay is not respected, the latest command will be ignored.
Approximately 1 µs is required for unlocking the device after the valid 64-bit password has
been provided.
6.3.5
Non-volatile Protection mode command set
Enter Non-volatile Protection Command Set command
Three Bus Write cycles are required to issue the Enter Non-volatile Protection Command
Set command. Once the command has been issued, the commands related to the NonVolatile Protection mode can be issued to the device.
Non-volatile Protection Bit Program command (NVPB Program)
A block can be protected from program or erase by issuing a Non-volatile Protection Bit
command along with the block address. This command sets the NVPB to ‘1’ for a given
block.
Read Non-volatile Protection Bit Status command (Read NVPB Status)
The status of a NVPB for a given block or group of blocks can be read by issuing a Read
Non-Volatile Modify Protection Bit command along with the block address.
Clear all Non-volatile Protection Bits command (Clear all NVPBs)
The NVPBs are erased simultaneously by issuing a Clear all Non-volatile Protection Bits
command. No specific block address is required. If the NVPB Lock bit is set to ‘0’, the
command fails.
44/94
M29W128GH, M29W128GL
Figure 6.
Command interface
NVPB Program/Erase algorithm
Enter NVPB
command set.
Program NVPB
Addr = BAd
Read Byte twice
Addr = BAd
DQ6=
Toggle
NO
YES
NO
DQ5=1
YES
Wait 500 ms
Read Byte twice
Addr = BAd
DQ6=
Toggle
NO
Read Byte twice
Addr = BAd
NO
DQ0=
'1'(Erase)
'0'(Program)
YES
Fail
Reset
Pass
Exit NVPB
command set
AI14242
45/94
Command interface
6.3.6
M29W128GH, M29W128GL
NVPB Lock Bit command set
Enter NVPB Lock Bit Command Set command
Three bus Write cycles are required to issue the Enter NVPB Lock Bit Command Set
command. Once the command has been issued, the commands allowing to set the NVPB
Lock bit can be issued to the device.
NVPB Lock Bit Program command
This command is used to set the NVPB Lock bit to ‘0’ thus locking the NVPBs, and
preventing them from being modified.
Read NVPB Lock Bit Status command
This command is used to read the status of the NVPB Lock bit.
6.3.7
Volatile Protection mode command set
Enter Volatile Protection Command Set command
Three bus Write cycles are required to issue the Enter Volatile Protection Command Set
command. Once the command has been issued, the commands related to the Volatile
Protection mode can be issued to the device.
Volatile Protection Bit Program command (VPB Program)
The VPB Program command individually sets a VPB to ‘0’ for a given block.
If the NVPB for the same block is set, the block is locked regardless of the value of the VPB
bit. (see Table 19: Block protection status).
Read VPB Status command
The status of a VPB for a given block can be read by issuing a Read VPB Status command
along with the block address.
VPB Clear command
The VPB Clear command individually clears (sets to ‘1’) the VPB for a given block.
If the NVPB for the same block is set, the block is locked regardless of the value of the VPB
bit. (see Table 19: Block protection status).
6.3.8
Exit Protection command set
The Exit Protection Command Set command is used to exit from the Lock Register,
Password Protection, Non-Volatile Protection, Volatile Protection, and NVPB Lock Bit
Command Set mode. It return the device to Read mode.
46/94
M29W128GH, M29W128GL
Table 15.
Command interface
Block Protection commands, 8-bit mode(1)(2)(3)
Command
1st
2nd
3rd
4th
Ad
Data
Ad
Data
Ad
Data
55
AAA
40
AAA
60
5th
6th
7th
8th
Ad
Data
Ad
Data
Ad
Data
Ad
Data
Ad
Data
3
AAA
AA
555
Lock Register
Program
2
X
A0
X
Lock Register
Read
1
X
Enter
Password
Protection
Command
Set(4)
3
AAA
AA
555
55
Password
Program (6)(7)
2
X
A0
PWA
n
PWD
n
Password
Read
8
00
PWD
0
01
PWD
1
02
PWD
2
03
PWD
3
04
PWD
4
05
PWD
5
06
PWD
6
07
PWD
7
Password
Unlock(7)
1
1
00
25
00
03
00
PWD
0
01
PWD
1
02
PWD
2
03
PWD
3
04
PWD
4
05
PWD
5
Enter NonVolatile
Protection
Command
Set(4)
3
AAA
AA
555
55
AAA
C0
NVPB
Program(8)
2
X
A0
BAd
00
Clear all
NVPBs(9)
2
X
80
00
30
Read NVPB
Status (8)
1
BAd
RD(0)
Enter NVPB
Lock Bit
Command
Set
3
AAA
AA
555
55
AAA
50
NVPB Lock
Bit Program(8)
2
X
A0
X
00
Read NVPB
Lock Bit
Status (8)
1
X
RD(0)
Enter Volatile
Protection
Command
Set
3
AAA
AA
555
55
AAA
E0
VPB
Program(8)
2
X
A0
BAd
00
Read VPB
Status
1
X
RD(0)
VPB Clear(8)
2
X
A0
BAd
01
Exit Protection
Command Set
2
X
90
X
00
Enter Extended
Block(4)
3
AAA
AA
555
55
AAA
88
Exit Extended
Block
4
AAA
AA
555
55
AAA
90
X
00
Volatile Protection
NVPB Lock bit
Non-volatile Protection
Password Protection
Lock Register
Enter Lock
Register
Command
Set(4)
(10)
1.
Length
Bus operations
9th
10th
11th
Ad
Data
Ad
Data
Ad
Data
06
PWD
6
07
PWD
7
00
29
DATA
(5)
DATA
(5)
Ad address, Dat data, BAd Any address in the Block, RD Read data, PWDn Password byte 0 to 7, PWAn Password Address (n = 0 to 7), X Don’t care. All values in
the table are in hexadecimal.
47/94
Command interface
M29W128GH, M29W128GL
2.
Grey cells represent Read cycles. The other cells are Write cycles.
3.
DQ15 to DQ8 are ‘Don’t care’ during unlock and command cycles. A22 to A16 are ‘Don’t care’ during unlock and command cycles unless an address is required.
4.
An Enter command sequence must be issued prior to any operation. It disables read and write operations from and to block 0. Read and write operations from any
other block are allowed.
5.
DATA = Lock Register content.
6.
Only one portion of password can be programmed or read by each Password Program command.
7.
The password portion can be entered or read in any order as long as the entire 64-bit password is entered or read.
8.
Protected and unprotected states correspond to 00 and 01, respectively.
9.
The Clear all NVPBs command programs all NVPBs before erasure in order to prevent the over-erasure of previously cleared Non Volatile Modify Protection bits.
10. If an Entry Command Set command is issued, an Exit Protection Command Set command must be issued to return the device to Read mode.
48/94
M29W128GH, M29W128GL
Command interface
Block Protection commands, 16-bit mode(1)(2)(3)
Table 16.
1st
2nd
3rd
4th
Ad
Data
Ad
Data
Ad
Data
55
555
40
555
60
Enter Lock Register
Command Set(4)
3
555
AA
2AA
Lock Register Program
2
X
A0
X
Lock Register Read
1
X
Enter Password
Protection Command
Set(4)
3
555
Password Program (6)(7)
2
Password Read
4
7
Enter Non-volatile
Protection Command
Set(4)
5th
Ad
Data
X
A0
PWAn
PWDn
PWD0
01
PWD1
02
PWD2
03
PWD3
00
25
00
03
00
PWD0
01
PWD1
3
555
AA
2AA
55
555
C0
NVPB Program(8)
2
X
A0
BAd
00
Clear all NVPBs(9)
2
X
80
00
30
Read NVPB Status
1
BAd
RD(0)
NVPB Lock bit
Enter NVPB Lock Bit
Command Set
3
555
AA
2AA
55
555
50
NVPB Lock Bit Program
2
X
A0
X
00
Read NVPB Lock Bit
Status
1
X
RD(0)
Enter Volatile Protection
Command Set
3
555
AA
2AA
55
555
E0
VPB Program
2
X
A0
BAd
00
Read VPB Status
1
X
RD(0)
VPB Clear
X
00
Non-Volatile Protection
Data
Ad
Data
Ad
Data
02
PWD2
03
PWD3
00
29
(5)
00
55
2
X
A0
BAd
01
Exit Protection Command
Set(10)
2
X
90
X
00
Enter Extended Block(4)
3
555
AA
2AA
55
555
88
Exit Extended Block
4
555
AA
2AA
55
555
90
1.
Ad
DATA
2AA
Password
7th
(5)
AA
Unlock(7)
6th
DATA
Volatile Protection
Password Protection
Lock register
Command
Length
Bus operations
Ad address, Dat data, BAd Any address in the Block, RD Read data, PWDn Password word 0 to 3, PWAn Password Address (n = 0 to 3), X Don’t care. All values in
the table are in hexadecimal.
2.
Grey cells represent Read cycles. The other cells are Write cycles.
3.
DQ15 to DQ8 are ‘Don’t care’ during unlock and command cycles. A22 to A16 are ‘Don’t care’ during unlock and command cycles unless an address is required.
4.
An Enter command sequence must be issued prior to any operation. It disables read and write operations from and to block 0. Read and write operations from any
other block are allowed.
5.
DATA = Lock Register content.
6.
Only one portion of password can be programmed or read by each Password Program command.
7.
The password portion can be entered or read in any order as long as the entire 64-bit password is entered or read.
8.
Protected and unprotected states correspond to 00 and 01, respectively.
9.
The Clear all NVPBs command programs all NVPBs before erasure in order to prevent the over-erasure of previously cleared Non-volatile Modify Protection bits.
10. If an Entry Command Set command is issued, an Exit Protection Command Set command must be issued to return the device to Read mode.
49/94
Command interface
Table 17.
M29W128GH, M29W128GL
Program, Erase times and Program, Erase endurance cycles
Parameter
Min
Typ(1)(2)
Chip Erase
40
Block Erase (128 kbytes)(4)
0.5
Erase Suspend latency time
25
Block Erase timeout
s
s
35
µs
Write to Buffer Program
(64 bytes at-a-time)
VPP/WP = VPPH
51
VPP/WP = VIH
78
200(3)
µs
VPP/WP = VPPH
51
VPP/WP = VIH
78
Chip Program (word by word)
Program)(5)
Chip Program (Write to Buffer Program with VPP/WP = VPPH)(5)
(5)
Chip Program (Enhanced Buffered Program with VPP/WP =
VPP)(5)
Program Suspend latency time
Program/Erase cycles (per block)
Data retention
µs
200(3)
µs
Chip Program (byte by byte)
Chip Program (Enhanced Buffered Program)
µs
16
Write to Buffer Program
(32 words at-a-time)
Chip Program (Write to Buffer
µs
16
Single Word Program
Word Program
400
Unit
(3)
50
Single Byte Program
Byte Program
Max(2)
270
800(3)
s
135
400
(3)
s
20
200(3)
s
13
50(3)
s
8
40
s
5
25
s
5
15
µs
100,000
Cycles
20
Years
1. Typical values measured at room temperature and nominal voltages.
2. Sampled, but not 100% tested.
3. Maximum value measured at worst case conditions for both temperature and VCC after 100,000 program/erase cycles.
4. Block Erase Polling cycle time (seeFigure 24: Data polling AC waveforms).
5. Intrinsic program timing, that means without the time required to execute the bus cycles to load the program commands.
50/94
M29W128GH, M29W128GL
7
Registers
Registers
The device feature two registers:
7.1
●
A Lock Register that allows to configure the memory blocks and extended memory
block protection (see Table 19: Block protection status)
●
A Status Register that provides information on the current or previous Program or
Erase operations.
Lock Register
The Lock Register is a 16-bit one-time programmable register. The bits in the Lock Register
are summarized in Table 18: Lock Register bits.
See Section 6.3.3: Lock Register command set for a description of the commands allowing
to read and program the Lock Register.
7.1.1
Password Protection Mode Lock bit (DQ2)
The Password Protection Mode Lock bit, DQ0, is one-time programmable. Programming
(setting to ‘0’) this bit permanently places the device in Password Protection mode.
Any attempt to program the Password Protection mode Lock bit when the Non-volatile
Protection Mode bit is programmed causes the operation to abort and the device to return to
Read mode.
7.1.2
Non-volatile Protection Mode Lock bit (DQ1)
The Non-volatile Protection Mode Lock bit, DQ1, is one-time programmable. Programming
(setting to ‘0’) this bit permanently places the device in Non-volatile Protection mode.
When shipped from the factory, all parts default to operate in Non-volatile Protection mode.
The memory blocks can be either unprotected (NVPBs set to ‘1’) or protected (NVPBs set to
‘0’), according to the ordering option that has been chosen.
Any attempt to program the Non-volatile Protection mode Lock bit when the Password
Protection Mode bit is programmed causes the operation to abort and the device to return to
Read mode.
7.1.3
Extended Block Protection bit (DQ0)
If the device has not been shipped with the extended memory block factory locked, the block
can be protected by setting the Extended Memory Block Protection bit, DQ0, to ‘0’.
However, this bit is one-time programmable and once protected the extended memory block
cannot be unprotected.
The extended memory block protection status can be read in Auto Select mode either by
applying VID to A9 (see Table 8 and Table 9) or by issuing an Auto Select command (see
Table 10 and Table 11).
7.1.4
DQ15 to DQ3 reserved
They are ‘Don’t care’.
51/94
Registers
M29W128GH, M29W128GL
Lock Register bits(1)
Table 18.
DQ15-3
DQ2
DQ1
DQ0
Don’t care
Password Protection Mode
Lock bit
Non-volatile Protection
Mode Lock bit
Extended Block
Protection bit
1. DQ0, DQ1 and DQ2 Lock Register bits are set to ‘1’ when shipped from the factory.
Table 19.
Block protection status
NVPB Lock bit(1)
Block
NVPB(2)
Block
VPB(3)
Block
protection
status
Block protection status
0
0
x
01h
Block protected (non-volatile protection
through NVPB)
0
1
1
00h
Block unprotected
0
1
0
00h
Block protected (volatile protection
through VPB)
1
0
x
01h
Block protected (non-volatile protection
through NVPB)
1
1
0
01h
Block protected (volatile protection
through VPB)
1
1
1
00h
Block unprotected
1. If the NVPB Lock bit is set to ‘0’, all NVPBs are locked. If the NVPB Lock bit is set to ‘1’, all NVPBs are
unlocked.
2. If the Block NVPB is set to ‘0’, the block is protected, if set to ‘1’, it is unprotected.
3. If the Block VPB is set to ‘0’, the block is protected, if set to ‘1’, it is unprotected.
52/94
M29W128GH, M29W128GL
Figure 7.
Registers
Lock Register program flowchart
START
Write Unlock cycles:
Add 555h, Data AAh
Add 2AAh, Data 55h
Unlock cycle 1
unlock cycle 2
Write
Enter Lock Register command set:
Add 555h, Data 40h
Program Lock Register Data:
Add Dont' care, Data A0h
Add Dont' care(1), Data PDh
Polling algorithm
YES
Done
NO
DQ5 = 1
NO
YES
Device returned
to Read mode
PASS:
Write Lock Register Exit command:
Add Dont' care, Data 90h
Add Dont' care, Data 00h
FAIL
Reset to return
the device to Read mode
ai13677
1. PD is the programmed data (see Table 18: Lock Register bits).
2. The Lock Register can only be programmed once.
53/94
Registers
7.2
M29W128GH, M29W128GL
Status Register
The M29W128GH/L has one Status Register. The various bits convey information and
errors on the current and previous program/erase operation. Bus Read operations from any
address within the memory, always read the Status Register during Program and Erase
operations. It is also read during Erase Suspend when an address within a block being
erased is accessed.
The bits in the Status Register are summarized in Table 20: Status Register bits.
7.2.1
Data Polling bit (DQ7)
The Data Polling bit can be used to identify whether the Program/Erase controller has
successfully completed its operation or if it has responded to an Erase Suspend. The Data
Polling bit is output on DQ7 when the Status Register is read.
During Program operations the Data Polling bit outputs the complement of the bit being
programmed to DQ7. After successful completion of the Program operation the memory
returns to Read mode and Bus Read operations, from the address just programmed, output
DQ7, not its complement.
During Erase operations the Data Polling bit outputs ’0’, the complement of the erased state
of DQ7. After successful completion of the Erase operation the memory returns to Read
mode.
In Erase Suspend mode the Data Polling bit will output a ’1’ during a Bus Read operation
within a block being erased. The Data Polling bit will change from ’0’ to ’1’ when the
Program/Erase controller has suspended the Erase operation.
Figure 8: Data polling flowchart, gives an example of how to use the Data Polling bit. A Valid
Address is the address being programmed or an address within the block being erased.
7.2.2
Toggle bit (DQ6)
The Toggle bit can be used to identify whether the Program/Erase controller has
successfully completed its operation or if it has responded to an Erase Suspend. The Toggle
bit is output on DQ6 when the Status Register is read.
During a Program/Erase operation the Toggle bit changes from ’0’ to ’1’ to ’0’, etc., with
successive Bus Read operations at any address. After successful completion of the
operation the memory returns to Read mode.
During Erase Suspend mode the Toggle bit will output when addressing a cell within a block
being erased. The Toggle bit will stop toggling when the Program/Erase controller has
suspended the Erase operation.
Figure 9: Toggle flowchart, gives an example of how to use the Data Toggle bit.
7.2.3
Error bit (DQ5)
The Error bit can be used to identify errors detected by the Program/Erase controller. The
Error bit is set to ’1’ when a Program, Block Erase or Chip Erase operation fails to write the
correct data to the memory. If the Error bit is set a Read/Reset command must be issued
54/94
M29W128GH, M29W128GL
Registers
before other commands are issued. The Error bit is output on DQ5 when the Status Register
is read.
Note that the Program command cannot change a bit set to ’0’ back to ’1’ and attempting to
do so will set DQ5 to ‘1’. A Bus Read operation to that address will show the bit is still ‘0’.
One of the Erase commands must be used to set all the bits in a block or in the whole
memory from ’0’ to ’1’.
7.2.4
Erase Timer bit (DQ3)
The Erase Timer bit can be used to identify the start of Program/Erase controller operation
during a Block Erase command. Once the Program/Erase controller starts erasing the Erase
Timer bit is set to ’1’. Before the Program/Erase controller starts the Erase Timer bit is set to
’0’ and additional blocks to be erased may be written to the command interface. The Erase
Timer bit is output on DQ3 when the Status Register is read.
7.2.5
Alternative Toggle bit (DQ2)
The Alternative Toggle bit can be used to monitor the Program/Erase controller during Erase
operations. The Alternative Toggle bit is output on DQ2 when the Status Register is read.
During Chip Erase and Block Erase operations the Toggle bit changes from ’0’ to ’1’ to ’0’,
etc., with successive Bus Read operations from addresses within the blocks being erased. A
protected block is treated the same as a block not being erased. Once the operation
completes the memory returns to Read mode.
During Erase Suspend the Alternative Toggle bit changes from ’0’ to ’1’ to ’0’, etc. with
successive Bus Read operations from addresses within the blocks being erased. Bus Read
operations to addresses within blocks not being erased will output the memory array data as
if in Read mode.
After an Erase operation that causes the Error bit to be set, the Alternative Toggle bit can be
used to identify which block or blocks have caused the error. The Alternative Toggle bit
changes from ’0’ to ’1’ to ’0’, etc. with successive Bus Read Operations from addresses
within blocks that have not erased correctly. The Alternative Toggle bit does not change if
the addressed block has erased correctly.
7.3
Buffered Program Abort bit (DQ1)
The Buffered Program Abort bit, DQ1, is set to ‘1’ when a Write to Buffer Program or
Enhanced Buffered Program operation aborts. The Buffered Program Abort and Reset
command must be issued to return the device to Read mode (see Write to Buffer Program in
Section 6.1: Standard commands).
55/94
Registers
M29W128GH, M29W128GL
Status Register bits(1)
Table 20.
Operation
Address
DQ7
DQ6
Any address
DQ7
Toggle
0
Any address
DQ7
Toggle
Any address
DQ7
Program Error
Any address
Chip Erase
Program(2)
Program During Erase Suspend
Buffered Program Abort
(2)
Block Erase before timeout
Block Erase
DQ5 DQ3
DQ2
DQ1
RB
–
–
0
0
0
–
–
–
0
Toggle
0
–
–
1
0
DQ7
Toggle
1
–
–
–
Hi-Z
Any address
0
Toggle
0
1
Toggle
–
0
Erasing block
0
Toggle
0
0
Toggle
–
0
Non-erasing
block
0
Toggle
0
0
No
toggle
–
0
Erasing block
0
Toggle
0
1
Toggle
–
0
Non-erasing
block
0
Toggle
0
1
No
toggle
–
0
Erasing block
1
No
Toggle
0
–
Toggle
–
Hi-Z
–
Hi-Z
Erase Suspend
Non-erasing
block
Data read as normal
Good block
address
0
Toggle
1
1
No
toggle
–
Hi-Z
Faulty Block
address
0
Toggle
1
1
Toggle
–
Hi-Z
Erase Error
1. Unspecified data bits should be ignored.
2. DQ7 for Write to Buffer Program and Enhanced Buffered Program is related to the last address location
loaded.
56/94
M29W128GH, M29W128GL
Figure 8.
Registers
Data polling flowchart
START
READ DQ5 & DQ7
at VALID ADDRESS
DQ7
=
DATA
YES
NO
NO
DQ5 = 1
YES
READ DQ7
at VALID ADDRESS
DQ7
=
DATA
NO
FAIL
YES
PASS
AI07760
57/94
Registers
M29W128GH, M29W128GL
Figure 9.
Toggle flowchart
START
READ DQ6 at
Valid Address
READ
DQ5 & DQ6
at Valid Address
DQ6
=
TOGGLE
NO
YES
NO
DQ5
=1
YES
READ DQ6
TWICE
at Valid Address
DQ6
=
TOGGLE
NO
YES
FAIL
PASS
AI11530
58/94
M29W128GH, M29W128GL
8
Maximum ratings
Maximum ratings
Stressing the device above the rating listed in Table 21: Absolute maximum ratings may
cause permanent damage to the device. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability. These are stress ratings only and
operation of the device at these or any other conditions above those indicated in the
operating sections of this specification is not implied. Refer also to the Numonyx SURE
Program and other relevant quality documents.
Table 21.
Absolute maximum ratings
Symbol
Parameter
Min
Max
Unit
TBIAS
Temperature under bias
−50
125
°C
TSTG
Storage temperature
−65
150
°C
−0.6
VCC + 0.6
V
voltage(1)(2)
VIO
Input or output
VCC
Supply voltage
−0.6
4
V
Input/output supply voltage
−0.6
4
V
Identification voltage
−0.6
13.5
V
Program voltage
−0.6
13.5
V
VCCQ
VID
VPPH(3)
1. Minimum voltage may undershoot to −2 V during transition and for less than 20 ns during transitions.
2. Maximum voltage may overshoot to VCC + 2 V during transition and for less than 20 ns during transitions.
3. VPPH must not remain at 12 V for more than a total of 80 hrs.
59/94
DC and AC parameters
9
M29W128GH, M29W128GL
DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 22: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 22.
Operating and AC measurement conditions
M29W128GH, M29W128GL
70 or 60(1) ns
Parameter
80 ns
Min
Max
Min
Max
VCC supply voltage
2.7
3.6
2.7
3.6
V
VCCQ supply voltage (VCCQ ≤VCC)
2.7
3.6
1.65
3.6
V
Ambient operating temperature
−40
85
−40
85
°C
Load capacitance (CL)
30
Input rise and fall times
30
10
Input pulse voltages
Input and output timing ref. voltages
0 to VCCQ
V
VCCQ/2
VCCQ/2
V
VCC
VCCQ
25 kΩ
DEVICE
UNDER
TEST
CL
0.1 µF
ns
0 to VCCQ
Figure 10. AC measurement load circuit
VPP
pF
10
1. Only available upon customer request.
25 kΩ
0.1 µF
CL includes JIG capacitance
AI05558b
60/94
Unit
M29W128GH, M29W128GL
DC and AC parameters
Figure 11. AC measurement I/O waveform
VCCQ
VCCQ/2
0V
AI05557b
Table 23.
Power-up waiting timings
Symbol
Alt.
M29W128GH,
M29W128GL
Parameter
70 or 60
VCC
tVCHVCQH
tVCHRH(3)
tVCQHRH
tRHEL
(3)
(2)
High to
VCCQ(2) High
(1)
ns
Unit
80 ns
Min
0
µs
tVCS
VCC High to rising edge of RP
Min
35
µs
tVIOS
VCCQ High to rising edge of RP
Min
0
µs
RP High to Chip Enable Low
Min
50
µs
RP High to Write Enable Low
Min
500
µs
tRH
tRHWL
1. Only available upon customer request.
2. VCC and VCCQ ramps must be synchronized during power-up.
3. If RP is not stable for tVCHRH or tVCQHRH, the device does not permit any Read and Write operations and a hardware reset
is required.
Figure 12. Power-up waiting timings
tVCHVCQH
VCC
VCCQ
tRHEL
E
tVCQHRH
RP
tVCHRH
W
tRHWL
AI14247
61/94
DC and AC parameters
M29W128GH, M29W128GL
Device capacitance(1)
Table 24.
Symbol
CIN
Parameter
Input capacitance
Output capacitance
COUT
Test condition
Min
Max
Unit
VIN = 0 V
6
pF
VOUT = 0 V
12
pF
1. Sampled only, not 100% tested.
Table 25.
DC characteristics
Symbol
Parameter
Max
Unit
0 V ≤VIN ≤VCC
±1
µA
0 V ≤VOUT ≤VCC
±1
µA
Random Read
E = VIL, G = VIH,
f = 6 MHz
10
mA
Page Read
E = VIL, G = VIH,
f = 10 MHz
15
mA
E = VCCQ ± 0.2 V,
RP = VCCQ ± 0.2 V
100
µA
VPP/WP =
VIL or VIH
20
mA
VPP/WP = VPPH
20
mA
ILI(1)
Input leakage current
ILO
Output leakage current
ICC1
ICC2
ICC3(2)
Read current
Supply current (Standby)
Supply current (Program/Erase)
Read or
Standby
IPP1
IPP2
Program
current
(Program)
Reset
Test condition
Program/Erase
controller active
Min
Typ
VPP/WP ≤VCC
1
5
µA
RP = VSS ± 0.2 V
1
5
µA
Program
operation
ongoing
VPP/WP = 12 V ± 5%
1
10
mA
IPP3
VPP/WP = VCC
1
5
µA
Erase
Program
operation
current (Erase)
ongoing
VPP/WP = 12 V ± 5%
3
10
mA
IPP4
VPP/WP = VCC
1
5
µA
VIL
Input Low voltage
VCC ≥ 2.7 V
−0.5
0.3VCCQ
V
VIH
Input High voltage
VCC ≥ 2.7 V
0.7VCCQ
VCCQ+0.4
V
VOL
Output Low voltage
IOL = 100 µA, VCC = VCC(min),
VCCQ = VCCQ(min)
0.15VCCQ
V
VOH
Output High voltage
IOH = 100 µA, VCC = VCC(min),
VCCQ = VCCQ(min)
VID
Identification voltage
11.5
12.5
V
Voltage for VPP/WP Program
acceleration
11.4
12.6
V
Program/Erase lockout supply
voltage
2.3
2.5
V
VPPH
VLKO(2)
1. The maximum input leakage current is ±5 µA on the VPP/WP pin.
2. Sampled only, not 100% tested.
62/94
0.85VCCQ
V
M29W128GH, M29W128GL
DC and AC parameters
Figure 13. Random Read AC waveforms (8-bit mode)
tAVAV
A0-A22/
A–1
VALID
tAVQV
tAXQX
E
tELQV
tEHQX
tELQX
tEHQZ
G
(8-bit mode)
tGLQX
tGHQX
tGLQV
tGHQZ
DQ0-DQ7
VALID
tBHQV
BYTE
tELBL/tELBH
tBLQZ
AI08970
Figure 14. Random Read AC waveforms (16-bit mode)
tAVAV
A0-A22
VALID
tAVQV
tAXQX
E
tELQV
tEHQX
tELQX
tEHQZ
G
(8-bit mode)
tGLQX
tGHQX
tGLQV
tGHQZ
DQ0-DQ14,
DQ15A–1
VALID
tBHQV
BYTE
tELBL/tELBH
tBLQZ
AI13698
63/94
64/94
DQ0-DQ15
DQ15A-1
G
E
tELQV
tAVQV
tGLQV
VALID
VALID
tAVQV1
VALID
A0-A2
VALID
VALID
A3-A22
VALID
VALID
VALID
VALID
VALID
VALID
VALID
VALID
VALID
VALID
tGHQZ
tGHQX
tEHQZ
VALID
VALID
AI08971c
tEHQX
DC and AC parameters
M29W128GH, M29W128GL
Figure 15. Page Read AC waveforms (16-bit mode)
M29W128GH, M29W128GL
Table 26.
DC and AC parameters
Read AC characteristics
M29W128GH, M29W128GL
Test
condition
80 ns
VCCQ=1.65 V to
VCC
Unit
70
80
ns
60
70
80
ns
E = VIL
,
Max
G = VIL
25
25
30
ns
Chip Enable Low to Output
Transition
G = VIL
Min
0
0
0
ns
Chip Enable Low to Output
Valid
G = VIL Max
60
70
80
ns
tOLZ
Output Enable Low to
Output Transition
E = VIL
Min
0
0
0
ns
tGLQV
tOE
Output Enable Low to
Output Valid
E = VIL Max
25
25
30
ns
tEHQZ(2)
tHZ
Chip Enable High to Output
Hi-Z
G = VIL Max
20
20
30
ns
tGHQZ(2)
tDF
Output Enable High to
Output Hi-Z
E = VIL Max
20
20
20
ns
tEHQX
tGHQX
tAXQX
tOH
Chip Enable, Output Enable
or Address Transition to
Output Transition
Min
0
0
0
ns
Symbol
Alt.
Parameter
tAVAV
tRC
Address Valid to Next
Address Valid
E = VIL
,
G = VIL
Min
60
tAVQV
tACC
Address Valid to Output
Valid
E = VIL
,
Max
G = VIL
tAVQV1
tPAGE
Address Valid to Output
Valid (Page)
tELQX(2)
tLZ
tELQV
tE
tGLQX(2)
60 ns(1)
70 ns
VCCQ=VCC VCCQ=VCC
tELBL
tELBH
tELFL Chip Enable to BYTE Low
tELFH or High
Max
5
5
5
ns
tBLQZ
tFLQZ BYTE Low to Output Hi-Z
Max
25
25
25
ns
tBHQV
tFHQV BYTE High to Output Valid
Max
30
30
30
ns
1. Only available upon customer request.
2. Sampled only, not 100% tested.
65/94
DC and AC parameters
M29W128GH, M29W128GL
Figure 16. Write Enable Controlled Program waveforms (8-bit mode)
3rd cycle
4th cycle
A0-A22/
A–1
Read cycle
Data Polling
tAVAV
tAVAV
555h
PA
PA
tAVWL
tWLAX
tELQV
tWHEH
tELWL
E
tGLQV
tGHWL
G
tWLWH
tWHWL
W
tDVWH
DQ0-DQ7
tWHWH1
AOh
PD
DQ7 DOUT
tGHQZ
tAXQX
DOUT
tWHDX
AI13333
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit and by a read operation that outputs the data, DOUT, programmed by the previous
Program command.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. SeeTable 27: Write AC characteristics, Write Enable Controlled, Table 28: Write AC characteristics, Chip Enable
Controlled and Table 26: Read AC characteristics for details on the timings.
66/94
M29W128GH, M29W128GL
DC and AC parameters
Figure 17. Write Enable Controlled Program waveforms (16-bit mode)
3rd cycle
4th cycle
A0-A22
Read cycle
Data Polling
tAVAV
tAVAV
555h
PA
PA
tAVWL
tWLAX
tELQV
tWHEH
tELWL
E
tGLQV
tGHWL
G
tWLWH
tWHWL
W
tDVWH
DQ0-DQ1',
DQ15A–1
tWHWH1
AOh
PD
DQ7 DOUT
tGHQZ
tAXQX
DOUT
tWHDX
AI13699
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit and by a read operation that outputs the data, DOUT, programmed by the previous
Program command.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. SeeTable 27: Write AC characteristics, Write Enable Controlled, Table 28: Write AC characteristics, Chip Enable
Controlled and Table 26: Read AC characteristics for details on the timings.
67/94
DC and AC parameters
Table 27.
M29W128GH, M29W128GL
M
Write AC characteristics, Write Enable Controlled
M29W128GH, M29W128GL
Symbol
Alt
Parameter
Unit
60 ns(1)
70 ns
80 ns
tAVAV
tWC
Address Valid to Next Address Valid
Min
60
70
80
ns
tELWL
tCS
Chip Enable Low to Write Enable Low
Min
0
0
0
ns
tWLWH
tWP
Write Enable Low to Write Enable High
Min
35
35
35
ns
tDVWH
tDS
Input Valid to Write Enable High
Min
45
45
45
ns
tWHDX
tDH
Write Enable High to Input Transition
Min
0
0
0
ns
tWHEH
tCH
Write Enable High to Chip Enable High
Min
0
0
0
ns
tWHWL
tWPH
Write Enable High to Write Enable Low
Min
30
30
30
ns
tAVWL
tAS
Address Valid to Write Enable Low
Min
0
0
0
ns
tWLAX
tAH
Write Enable Low to Address Transition
Min
45
45
45
ns
Output Enable High to Write Enable Low
Min
0
0
0
ns
tOEH
Write Enable High to Output Enable Low
Min
0
0
0
ns
tBUSY
Program/Erase Valid to RB Low
Max
30
30
30
ns
tVCS
VCC High to Chip Enable Low
Min
50
50
50
µs
tGHWL
tWHGL
tWHRL
(2)
tVCHEL
1. Only available upon customer request.
2. Sampled only, not 100% tested.
68/94
M29W128GH, M29W128GL
DC and AC parameters
Figure 18. Chip Enable Controlled Program waveforms (8-bit mode)
3rd cycle
4th cycle
Data Polling
PA
PA
tAVAV
A0-A22/
A–1
555h
tAVEL
tELAX
tEHWH
tWLEL
W
tGHEL
G
tELEH
tEHEL1
E
tDVEH
DQ0-DQ7
tWHWH1
AOh
PD
DQ7 DOUT
tEHDX
AI13334
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. See Table 27: Write AC characteristics, Write Enable Controlled, Table 28: Write AC characteristics, Chip Enable
Controlled and Table 26: Read AC characteristics for details on the timings.
69/94
DC and AC parameters
M29W128GH, M29W128GL
Figure 19. Chip Enable Controlled Program waveforms (16-bit mode)
3rd cycle
4th cycle
Data Polling
PA
PA
tAVAV
A0-A22
555h
tAVEL
tELAX
tEHWH
tWLEL
W
tGHEL
G
tELEH
tEHEL1
E
tDVEH
DQ0-DQ14
A–1
tWHWH1
AOh
PD
DQ7 DOUT
tEHDX
AI14100
1. Only the third and fourth cycles of the Program command are represented. The Program command is followed by the check
of Status Register Data Polling bit.
2. PA is the address of the memory location to be programmed. PD is the data to be programmed.
3. DQ7 is the complement of the data bit being programmed to DQ7 (see Section 7.2.1: Data Polling bit (DQ7)).
4. See Table 27: Write AC characteristics, Write Enable Controlled, Table 28: Write AC characteristics, Chip Enable
Controlled and Table 26: Read AC characteristics for details on the timings.
70/94
M29W128GH, M29W128GL
DC and AC parameters
Figure 20. Chip/Block Erase waveforms (8-bit mode)
tAVAV
A0-A22/
A–1
555h
2AAh
tAVWL
555h
555h
2AAh
555h/BAd
(1)
tWLAX
tWHEH
tELWL
E
tGHWL
G
tWLWH
tWHWL
W
tDVWH
DQ0-DQ7
AAh
55h
AAh
80h
55h
10h/
30h
tWHDX
AI13335
1. For a Chip Erase command, addresses and data are 555h and 10h, respectively, while they are BAd and 30h for a Block
Erase command.
2. BAd is the block address.
3. See Table 27: Write AC characteristics, Write Enable Controlled, Table 28: Write AC characteristics, Chip Enable
Controlled and Table 26: Read AC characteristics for details on the timings.
Table 28.
Write AC characteristics, Chip Enable Controlled
M29W128GH, M29W128GL
Symbol
Alt.
Parameter
Unit
60 ns(1)
70 ns
80 ns
tAVAV
tWC
Address Valid to Next Address Valid
Min
60
70
80
ns
tWLEL
tWS
Write Enable Low to Chip Enable Low
Min
0
0
0
ns
tELEH
tCP
Chip Enable Low to Chip Enable High
Min
35
35
35
ns
tDVEH
tDS
Input Valid to Chip Enable High
Min
45
45
45
ns
tEHDX
tDH
Chip Enable High to Input Transition
Min
0
0
0
ns
tEHWH
tWH
Chip Enable High to Write Enable High
Min
0
0
0
ns
tEHEL
tCPH
Chip Enable High to Chip Enable Low
Min
30
30
30
ns
tAVEL
tAS
Address Valid to Chip Enable Low
Min
0
0
0
ns
tELAX
tAH
Chip Enable Low to Address Transition
Min
45
45
45
ns
Output Enable High Chip Enable Low
Min
0
0
0
ns
tGHEL
1. Only available upon customer request.
71/94
DC and AC parameters
M29W128GH, M29W128GL
Figure 21. Reset AC waveforms (no program/erase ongoing)
RB
E, G
tPHEL,
tPHGL
RP
tPLPX
AI11300b
Figure 22. Reset during program/erase operation AC waveforms
tPLYH
RB
tRHEL, tRHGL
E, G
RP
tPLPX
AI11301b
Table 29.
Reset AC characteristics
Symbol
tPLYH(2)
Alt.
M29W128GH,
M29W128GL
Parameter
tREADY RP Low to Read mode, during Program or Erase
Unit
60(1)
70
80
Max
50
50
50
µs
tPLPX
tRP
RP Pulse width
Min
10
10
10
µs
tPHEL, tPHGL(2)
tRH
RP High to Write Enable Low, Chip Enable Low,
Output Enable Low
Min
50
50
50
ns
RP Low to Standby mode, during Read mode
Min
10
10
10
µs
RP Low to Standby mode, during Program or Erase Min
50
50
50
µs
RB High to Write Enable Low, Chip Enable Low,
Output Enable Low
0
0
0
ns
tRPD
tRHEL, tRHGL(2)
tRB
1. Only available upon customer request.
2. Sampled only, not 100% tested.
72/94
Min
M29W128GH, M29W128GL
DC and AC parameters
Figure 23. Accelerated program timing waveforms
VPPH
VPP/WP
VIL or VIH
tVHVPP
tVHVPP
AI05563
Figure 24. Data polling AC waveforms
tWHEH
tELQV
tEHQZ
tGHQZ
E
tGLQV
G
tWHGL2
W
tWHWH1 or tWHWH2
DQ7
DATA
DQ6-DQ0
DATA
DQ7
DQ6-DQ0=
Output flag
DQ7=
Valid data
DQ6-DQ0=
Valid data
Hi-Z
Hi-Z
tWHRL
R/B
AI13336c
1. DQ7 returns valid data bit when the ongoing Program or Erase command is completed.
2. See Table 30: Accelerated Program and Data Polling/Data Toggle AC characteristics and Table 26: Read AC
characteristics for details on the timings.
73/94
DC and AC parameters
M29W128GH, M29W128GL
Figure 25. Toggle/Alternative Toggle bit polling AC waveforms (8-bit mode)
A0-A22/
A–1
tGHAX
tAXGL
E
tWHGL2
tAVEL
tEHAX
W
tEHEL2
tGHGL2
tGHGL2
G
tGLQV
tWHDX
DQ6/DQ2
Data
Toggle
tELQV
Toggle
Toggle
Output
Valid
Stop
toggling
tWHRL
R/B
AI13337
1. DQ6 stops toggling when the ongoing Program or Erase command is completed. DQ2 stops toggling when the ongoing
Chip Erase or Block Erase command is completed.
2. See Table 30: Accelerated Program and Data Polling/Data Toggle AC characteristics and Table 26: Read AC
characteristics for details on the timings.
Table 30.
Symbol
Accelerated Program and Data Polling/Data Toggle AC characteristics
Alt
tVHVPP
M29W128GH,
M29W128GL
Parameter
Unit
60(1)
70
80
VPP/WP raising and falling time
Min
250
250
250
ns
tAXGL
tASO
Address setup time to Output Enable Low during
Toggle bit polling
Min
10
10
10
ns
tGHAX,
tEHAX
tAHT
Address hold time from Output Enable during
Toggle bit polling
Min
10
10
10
ns
tEHEL2
tEPH
Chip Enable High during Toggle bit polling
Min
10
10
10
ns
tWHGL2,
tGHGL2
tOEH
Output Hold time during Data and Toggle bit polling
Min
20
20
20
ns
Max
30
30
30
ns
tWHRL
tBUSY Program/Erase Valid to RB Low
1. Only available upon customer request.
74/94
M29W128GH, M29W128GL
10
Package mechanical
Package mechanical
In order to meet environmental requirements, Numonyx offers these devices in ECOPACK®
packages. ECOPACK® packages are lead-free. The category of second level interconnect
is marked on the package and on the inner box label, in compliance with JEDEC Standard
JESD97. The maximum ratings related to soldering conditions are also marked on the inner
box label.
Figure 26. TSOP56 – 56 lead plastic thin small outline, 14 x 20 mm, package outline
1
56
e
B
D1
L1
29
28
A2
E1
E
A
A1
DIE
α
L
C
CP
TSOP-K
1. Drawing is not to scale.
Table 31.
TSOP56 – 56 lead plastic thin small outline, 14 x 20 mm, package
mechanical data
Millimeters
Inches
Symbol
Typ
Min
A
Max
Typ
Min
1.20
Max
0.047
A1
0.10
0.05
0.15
0.004
0.002
0.006
A2
1.00
0.95
1.05
0.039
0.037
0.041
B
0.22
0.17
0.27
0.009
0.007
0.011
0.10
0.21
0.004
0.008
C
CP
0.10
0.004
D1
14.00
13.90
14.10
0.551
0.547
0.555
E
20.00
19.80
20.20
0.787
0.780
0.795
E1
18.40
18.30
18.50
0.724
0.720
0.728
e
0.50
–
–
0.020
–
–
L
0.60
0.50
0.70
0.024
0.020
0.028
α
3
0
5
3
0
5
75/94
Package mechanical
M29W128GH, M29W128GL
Figure 27. TBGA64 10 x 13 mm - 8 x 8 active ball array, 1 mm pitch, package outline
D
D1
FD
FE
E
SD
SE
E1
ddd
BALL "A1"
A
e
b
A2
A1
BGA-Z23
1. Drawing is not to scale.
Table 32.
TBGA64 10 x 13 mm - 8 x 8 active ball array, 1 mm pitch, package
mechanical data
millimeters
inches
Symbol
Typ
Min
A
Typ
Min
1.20
A1
0.30
A2
0.80
b
0.20
0.35
Max
0.047
0.012
0.008
0.014
0.014
0.020
0.031
0.35
0.50
D
10.00
9.90
10.10
0.394
0.390
0.398
D1
7.000
–
–
0.276
–
–
ddd
76/94
Max
0.10
0.004
e
1.00
–
–
0.039
–
–
E
13.00
12.90
13.10
0.512
0.508
0.516
E1
7.00
–
–
0.276
–
–
FD
1.50
–
–
0.059
–
–
FE
3.00
–
–
0.118
–
–
SD
0.50
–
–
0.020
–
–
SE
0.50
–
–
0.020
–
–
M29W128GH, M29W128GL
11
Ordering information
Ordering information
Table 33.
Ordering information scheme
Example:
M29W128GH 70 N
6
F
Device type
M29
Operating voltage
W = VCC = 2.7 to 3.6 V
Device function
128GH = 128 Mbit (x 8/x 16), page, uniform block, Flash memory,
highest block protected by VPP/WP
128GL = 128 Mbit (x 8/x 16), page, uniform block, Flash memory,
lowest block protected by VPP/WP
Speed
70 = 70 ns (80 ns if VCCQ = 1.65 V to VCC)
60 = 60 ns (80 ns if VCCQ = 1.65 V to VCC)(1)
Package
N = TSOP56: 14 x 20 mm
ZA = TBGA64: 10 x 13 mm, 1 mm pitch
Temperature range
6 = –40 to 85 °C
Option
E = ECOPACK package, standard packing
F = ECOPACK package, tape & reel packing
1. Only available upon customer request.
Note:
This product is also available with the extended memory block factory locked. For further
details and ordering information contact your nearest Numonyx sales office.
Devices are shipped from the factory with the memory content bits erased to ’1’. For a list of
available options (speed, package, etc.) or for further information on any aspect of this
device, please contact your nearest Numonyx Sales Office.
77/94
Block addresses and read/modify protection groups
Appendix A
78/94
M29W128GH, M29W128GL
Block addresses and read/modify protection
groups
Table 34.
Block addresses
Block
Protection group
Block size
(Kbytes/
Kwords)
8-bit address range
(in hexadecimal)
16-bit address range
(in hexadecimal)
0
Protection group
128/64
0000000–001FFFF
0000000–000FFFF
1
Protection group
128/64
0020000–003FFFF
0010000–001FFFF
2
Protection group
128/64
0040000–005FFFF
0020000–002FFFF
3
Protection group
128/64
0060000–007FFFF
0030000–003FFFF
4
Protection group
128/64
0080000–009FFFF
0040000–004FFFF
5
Protection group
128/64
00A0000–00BFFFF
0050000–005FFFF
6
Protection group
128/64
00C0000–00DFFFF
0060000–006FFFF
7
Protection group
128/64
00E0000–00FFFFF
0070000–007FFFF
8
Protection group
128/64
0100000–011FFFF
0080000–008FFFF
9
Protection group
128/64
0120000–013FFFF
0090000–009FFFF
10
Protection group
128/64
0140000–015FFFF
00A0000–00AFFFF
11
Protection group
128/64
0160000–017FFFF
00B0000–00BFFFF
12
Protection group
128/64
0180000–019FFFF
00C0000–00CFFFF
13
Protection group
128/64
01A0000–01BFFFF
00D0000–00DFFFF
14
Protection group
128/64
01C0000–01DFFFF
00E0000–00EFFFF
15
Protection group
128/64
01E0000–01FFFFF
00F0000–00FFFFF
16
Protection group
128/64
0200000–021FFFF
0100000–010FFFF
17
Protection group
128/64
0220000–023FFFF
0110000–011FFFF
18
Protection group
128/64
0240000–025FFFF
0120000–012FFFF
19
Protection group
128/64
0260000–027FFFF
0130000–013FFFF
20
Protection group
128/64
0280000–029FFFF
0140000–014FFFF
21
Protection group
128/64
02A0000–02BFFFF
0150000–015FFFF
22
Protection group
128/64
02C0000–02DFFFF
0160000–016FFFF
23
Protection group
128/64
02E0000–02FFFFF
0170000–017FFFF
24
Protection group
128/64
0300000–031FFFF
0180000–018FFFF
25
Protection group
128/64
0320000–033FFFF
0190000–019FFFF
26
Protection group
128/64
0340000–035FFFF
01A0000–01AFFFF
27
Protection group
128/64
0360000–037FFFF
01B0000–01BFFFF
28
Protection group
128/64
0380000–039FFFF
01C0000–01CFFFF
29
Protection group
128/64
03A0000–03BFFFF
01D0000–01DFFFF
M29W128GH, M29W128GL
Table 34.
Block addresses and read/modify protection groups
Block addresses (continued)
Block
Protection group
Block size
(Kbytes/
Kwords)
8-bit address range
(in hexadecimal)
16-bit address range
(in hexadecimal)
30
Protection group
128/64
03C0000–03DFFFF
01E0000–01EFFFF
31
Protection group
128/64
03E0000–03FFFFF
01F0000–01FFFFF
32
Protection group
128/64
0400000–041FFFF
0200000–020FFFF
33
Protection group
128/64
0420000–043FFFF
0210000–021FFFF
34
Protection group
128/64
0440000–045FFFF
0220000–022FFFF
35
Protection group
128/64
0460000–047FFFF
0230000–023FFFF
36
Protection group
128/64
0480000–049FFFF
0240000–024FFFF
37
Protection group
128/64
04A0000–04BFFFF
0250000–025FFFF
38
Protection group
128/64
04C0000–04DFFFF
0260000–026FFFF
39
Protection group
128/64
04E0000–04FFFFF
0270000–027FFFF
40
Protection group
128/64
0500000–051FFFF
0280000–028FFFF
41
Protection group
128/64
0520000–053FFFF
0290000–029FFFF
42
Protection group
128/64
0540000–055FFFF
02A0000–02AFFFF
43
Protection group
128/64
0560000–057FFFF
02B0000–02BFFFF
44
Protection group
128/64
0580000–059FFFF
02C0000–02CFFFF
45
Protection group
128/64
05A0000–05BFFFF
02D0000–02DFFFF
46
Protection group
128/64
05C0000–05DFFFF
02E0000–02EFFFF
47
Protection group
128/64
05E0000–05FFFFF
02F0000–02FFFFF
48
Protection group
128/64
0600000–061FFFF
0300000–030FFFF
49
Protection group
128/64
0620000–063FFFF
0310000–031FFFF
50
Protection group
128/64
0640000–065FFFF
0320000–032FFFF
51
Protection group
128/64
0660000–067FFFF
0330000–033FFFF
52
Protection group
128/64
0680000–069FFFF
0340000–034FFFF
53
Protection group
128/64
06A0000–06BFFFF
0350000–035FFFF
54
Protection group
128/64
06C0000–06DFFFF
0360000–036FFFF
55
Protection group
128/64
06E0000–06FFFFF
0370000–037FFFF
56
Protection group
128/64
0700000–071FFFF
0380000–038FFFF
57
Protection group
128/64
0720000–073FFFF
0390000–039FFFF
58
Protection group
128/64
0740000–075FFFF
03A0000–03AFFFF
59
Protection group
128/64
0760000–077FFFF
03B0000–03BFFFF
60
Protection group
128/64
0780000–079FFFF
03C0000–03CFFFF
61
Protection group
128/64
07A0000–07BFFFF
03D0000–03DFFFF
62
Protection group
128/64
07C0000–07DFFFF
03E0000–03EFFFF
79/94
Block addresses and read/modify protection groups
Table 34.
80/94
M29W128GH, M29W128GL
Block addresses (continued)
Block
Protection group
Block size
(Kbytes/
Kwords)
8-bit address range
(in hexadecimal)
16-bit address range
(in hexadecimal)
63
Protection group
128/64
07E0000–07FFFFF
03F0000–03FFFFF
64
Protection group
128/64
0800000–081FFFF
0400000–040FFFF
65
Protection group
128/64
0820000–083FFFF
0410000–041FFFF
66
Protection group
128/64
0840000–085FFFF
0420000–042FFFF
67
Protection group
128/64
0860000–087FFFF
0430000–043FFFF
68
Protection group
128/64
0880000–089FFFF
0440000–044FFFF
69
Protection group
128/64
08A0000–08BFFFF
0450000–045FFFF
70
Protection group
128/64
08C0000–08DFFFF
0460000–046FFFF
71
Protection group
128/64
08E0000–08FFFFF
0470000–047FFFF
72
Protection group
128/64
0900000–091FFFF
0480000–048FFFF
73
Protection group
128/64
0920000–093FFFF
0490000–049FFFF
74
Protection group
128/64
0940000–095FFFF
04A0000–04AFFFF
75
Protection group
128/64
0960000–097FFFF
04B0000–04BFFFF
76
Protection group
128/64
0980000–099FFFF
04C0000–04CFFFF
77
Protection group
128/64
09A0000–09BFFFF
04D0000–04DFFFF
78
Protection group
128/64
09C0000–09DFFFF
04E0000–04EFFFF
79
Protection group
128/64
09E0000–09FFFFF
04F0000–04FFFFF
80
Protection group
128/64
0A00000–0A1FFFF
0500000–050FFFF
81
Protection group
128/64
0A20000–0A3FFFF
0510000–051FFFF
82
Protection group
128/64
0A40000–0A5FFFF
0520000–052FFFF
83
Protection group
128/64
0A60000–0A7FFFF
0530000–053FFFF
84
Protection group
128/64
0A80000–0A9FFFF
0540000–054FFFF
85
Protection group
128/64
0AA0000–0ABFFFF
0550000–055FFFF
86
Protection group
128/64
0AC0000–0ADFFFF
0560000–056FFFF
87
Protection group
128/64
0AE0000–0AFFFFF
0570000–057FFFF
88
Protection group
128/64
0B00000–0B1FFFF
0580000–058FFFF
89
Protection group
128/64
0B20000–0B3FFFF
0590000–059FFFF
90
Protection group
128/64
0B40000–0B5FFFF
05A0000–05AFFFF
91
Protection group
128/64
0B60000–0B7FFFF
05B0000–05BFFFF
92
Protection group
128/64
0B80000–0B9FFFF
05C0000–05CFFFF
93
Protection group
128/64
0BA0000–0BBFFFF
05D0000–05DFFFF
94
Protection group
128/64
0BC0000–0BDFFFF
05E0000–05EFFFF
95
Protection group
128/64
0BE0000–0BFFFFF
05F0000–05FFFFF
M29W128GH, M29W128GL
Table 34.
Block addresses and read/modify protection groups
Block addresses (continued)
Block
Protection group
Block size
(Kbytes/
Kwords)
8-bit address range
(in hexadecimal)
16-bit address range
(in hexadecimal)
96
Protection group
128/64
0C00000–0C1FFFF
0600000–060FFFF
97
Protection group
128/64
0C20000–0C3FFFF
0610000–061FFFF
98
Protection group
128/64
0C40000–0C5FFFF
0620000–062FFFF
99
Protection group
128/64
0C60000–0C7FFFF
0630000–063FFFF
100
Protection group
128/64
0C80000–0C9FFFF
0640000–064FFFF
101
Protection group
128/64
0CA0000–0CBFFFF
0650000–065FFFF
102
Protection group
128/64
0CC0000–0CDFFFF
0660000–066FFFF
103
Protection group
128/64
0CE0000–0CFFFFF
0670000–067FFFF
104
Protection group
128/64
0D00000–0D1FFFF
0680000–068FFFF
105
Protection group
128/64
0D20000–0D3FFFF
0690000–069FFFF
106
Protection group
128/64
0D40000–0D5FFFF
06A0000–06AFFFF
107
Protection group
128/64
0D60000–0D7FFFF
06B0000–06BFFFF
108
Protection group
128/64
0D80000–0D9FFFF
06C0000–06CFFFF
109
Protection group
128/64
0DA0000–0DBFFFF
06D0000–06DFFFF
110
Protection group
128/64
0DC0000–0DDFFFF
06E0000–06EFFFF
111
Protection group
128/64
0DE0000–0DFFFFF
06F0000–06FFFFF
112
Protection group
128/64
0E00000–0E1FFFF
0700000–070FFFF
113
Protection group
128/64
0E20000–0E3FFFF
0710000–071FFFF
114
Protection group
128/64
0E40000–0E5FFFF
0720000–072FFFF
115
Protection group
128/64
0E60000–0E7FFFF
0730000–073FFFF
116
Protection group
128/64
0E80000–0E9FFFF
0740000–074FFFF
117
Protection group
128/64
0EA0000–0EBFFFF
0750000–075FFFF
118
Protection group
128/64
0EC0000–0EDFFFF
0760000–076FFFF
119
Protection group
128/64
0EE0000–0EFFFFF
0770000–077FFFF
120
Protection group
128/64
0F00000–0F1FFFF
0780000–078FFFF
121
Protection group
128/64
0F20000–0F3FFFF
0790000–079FFFF
122
Protection group
128/64
0F40000–0F5FFFF
07A0000–07AFFFF
123
Protection group
128/64
0F60000–0F7FFFF
07B0000–07BFFFF
124
Protection group
128/64
0F80000–0F9FFFF
07C0000–07CFFFF
125
Protection group
128/64
0FA0000–0FBFFFF
07D0000–07DFFFF
126
Protection group
128/64
0FC0000–0FDFFFF
07E0000–07EFFFF
127
Protection group
128/64
0FE0000–0FFFFFF
07F0000–07FFFFF
81/94
Common Flash interface (CFI)
Appendix B
M29W128GH, M29W128GL
Common Flash interface (CFI)
The common Flash interface is a JEDEC approved, standardized data structure that can be read from
the Flash memory device. It allows a system software to query the device to determine various electrical
and timing parameters, density information and functions supported by the memory. The system can
interface easily with the device, enabling the software to upgrade itself when necessary.
When the Read CFI Query command is issued, the memory enters Read CFI Query mode and read
operations output the CFI data. Table 35, Table 36, Table 37, Table 38, Table 39 and Table 40 show the
addresses (A-1, A0-A7) used to retrieve the data. The CFI data structure also contains a security area
where a 64 bit unique security number is written (see Table 40: Security code area). This area can be
accessed only in Read mode by the final user. It is impossible to change the security number after it has
been written by Numonyx.
Query structure overview(1)
Table 35.
Address
Sub-section name
Description
x 16
x8
10h
20h
CFI query identification string
Command set ID and algorithm data offset
1Bh
36h
System interface information
Device timing & voltage information
27h
4Eh
Device geometry definition
Flash device layout
40h
80h
Primary algorithm-specific extended query table
Additional information specific to the primary
algorithm (optional)
61h
C2h
Security code area
64 bit unique device number
1. Query data are always presented on the lowest order data outputs.
Table 36.
CFI query identification string(1)
Address
Data
x 16
x8
10h
20h
0051h
11h
22h
0052h
12h
24h
0059h
13h
26h
0002h
14h
28h
0000h
15h
2Ah
0040h
16h
2Ch
0000h
17h
2Eh
0000h
18h
30h
0000h
19h
32h
0000h
1Ah
34h
0000h
Description
‘Q’
Query Unique ASCII String ‘QRY’
‘R’
‘Y’
Primary algorithm command set and control interface ID code 16 bit
ID code defining a specific algorithm
Address for primary algorithm extended query table (see Table 39)
AMD
compatible
P = 40h
Alternate vendor command set and control interface ID code second
vendor - specified algorithm supported
NA
Address for alternate algorithm extended query table
NA
1. Query data are always presented on the lowest order data outputs (DQ7-DQ0) only. DQ8-DQ15 are ‘0’.
82/94
Value
M29W128GH, M29W128GL
Table 37.
Common Flash interface (CFI)
CFI query system interface information(1)
Address
Data
Description
Value
x 16
x8
1Bh
36h
0027h
VCC logic supply minimum Program/Erase voltage
bit 7 to 4BCD value in volts
bit 3 to 0BCD value in 100 mV
2.7 V
1Ch
38h
0036h
VCC logic supply maximum Program/Erase voltage
bit 7 to 4BCD value in volts
bit 3 to 0BCD value in 100 mV
3.6 V
1Dh
3Ah
00B5h
VPPH [programming] supply minimum Program/Erase voltage
bit 7 to 4HEX value in volts
bit 3 to 0BCD value in 100 mV
11.5 V
1Eh
3Ch
00C5h
VPPH [programming] supply maximum Program/Erase voltage
bit 7 to 4HEX value in volts
bit 3 to 0BCD value in 10 mV
12.5 V
1Fh
3Eh
0004h
Typical timeout for single byte/word program = 2n µs
16 µs
20h
21h
40h
42h
0004h
0009h
n
Typical timeout for minimum size write buffer program = 2 µs
n
Typical timeout for individual block erase = 2 ms
2n
0.5 s
22h
44h
0010h
Typical timeout for full Chip Erase =
23h
46h
0004h
Maximum timeout for byte/word program = 2n times typical
24h
25h
26h
48h
4Ah
4Ch
0002h
0003h
0004h
ms
40 s
n
Maximum timeout for write buffer program = 2 times typical
Maximum timeout per individual block erase =
n
16 µs
2n
times typical
Maximum timeout for Chip Erase = 2 times typical
200 µs
200 µs
2.3 s
400 s
1. The values given in the above table are valid for both packages.
83/94
Common Flash interface (CFI)
Table 38.
M29W128GH, M29W128GL
Device geometry definition
Address
Data
Description
Value
x 16
x8
27h
4Eh
0018h
Device size = 2n in number of bytes
28h
29h
50h
52h
0002h
0000h
Flash device interface code description
2Ah
2Bh
54h
56h
0006h
0000h
Maximum number of bytes in multiple-byte program or page= 2n
64
2Ch
58h
0001h
Number of Erase block regions. It specifies the number of regions
containing contiguous Erase blocks of the same size.
1
2Dh
2Eh
5Ah
5Ch
007Fh
0000h
Erase block region 1 information
Number of Erase blocks of identical size = 007Fh +1
2Fh
30h
5Eh
60h
0000h
0002h
Erase block region 1 information
Block size in region 1 = 0200h * 256 byte
31h
32h
33h
34h
62h
64h
66h
68h
0000h
0000h
0000h
0000h
Erase block region 2 information
0
35h
36h
37h
38h
6Ah
6Ch
6Eh
70h
0000h
0000h
0000h
0000h
Erase block region 3 information
0
39h
3Ah
3Bh
3Ch
72h
74h
76h
78h
0000h
0000h
0000h
0000h
Erase block region 4 information
0
84/94
16 Mbytes
x 8, x 16
Async.
128
128 Kbytes
M29W128GH, M29W128GL
Table 39.
Common Flash interface (CFI)
Primary algorithm-specific extended query table (1)
Address
Data
Description
Value
x 16
x8
40h
80h
0050h
41h
82h
0052h
42h
84h
0049h
43h
86h
0031h
Major version number, ASCII
‘1’
44h
88h
0033h
Minor version number, ASCII
‘3’
45h
8Ah
0010h
Address sensitive unlock (bits 1 to 0)
00 = required, 01= not required
Silicon revision number (bits 7 to 2)
Yes
46h
8Ch
0002h
Erase Suspend
00 = not supported, 01 = Read only, 02 = read and write
2
47h
8Eh
0001h
Block protection
00 = not supported, x = number of blocks per group
1
48h
90h
0000h
Temporary block unprotect
00 = not supported, 01 = supported
49h
92h
0008h
Block protect /unprotect
06 = M29W128GH/M29W128GL
4Ah
94h
0000h
Simultaneous operations: not supported
4Bh
96h
0000h
Burst mode, 00 = not supported, 01 = supported
4Ch
98h
0002h
Page mode, 00 = not supported, 02 = 8-word page
4Dh
9Ah
00B5h
VPPH supply minimum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV
11.5 V
4Eh
9Ch
00C5h
VPPH supply maximum Program/Erase voltage
bit 7 to 4 HEX value in volts
bit 3 to 0 BCD value in 100 mV
12.5 V
‘P’
Primary algorithm extended query table unique ASCII string “PRI”
‘R’
‘I’
Not
supported
6
NA
Not
supported
02
4Fh
9Eh
00xxh
Top/bottom boot block flag
xx = 04 = uniform device
xx = 05 = top/bottom
Uniform +
VPP/WP
protecting
highest or
lowest
block
50h
A0h
0001h
Program suspend, 00 = not supported, 01 = supported
Supported
1. The values given in the above table are valid for both packages.
85/94
Common Flash interface (CFI)
Table 40.
M29W128GH, M29W128GL
Security code area
Address
Data
x 16
x8
61h
C3h, C2h
XXXX
62h
C5h, C4h
XXXX
63h
C7h, C6h
XXXX
64h
C9h, C8h
XXXX
Description
64 bit: unique device number
86/94
M29W128GH, M29W128GL
Appendix C
Extended memory block
Extended memory block
The M29W128GH/L has an extra block, the extended memory block, that can be accessed
using a dedicated command. This extended memory block is 128 words in x 16 mode and
256 bytes in x 8 mode. It is used as a security block (to provide a permanent security
identification number) or to store additional information.
The device can be shipped either with the extended memory block factory locked, or factory
unlocked.
If the extended memory block is not factory locked, it can be customer lockable. Its status is
indicated by bit DQ7. This bit is permanently set to either ‘1’ or ‘0’ at the factory and cannot
be changed. When set to ‘1’, it indicates that the device is factory locked and the extended
memory block is protected. When set to ‘0’, it indicates that the device is customer lockable.
Bit DQ7 being permanently locked to either ‘1’ or ‘0’ is another security feature which
ensures that a customer lockable device cannot be used instead of a factory locked one.
Bit DQ7 is the most significant bit in the Extended Memory Block Verify Indicator. It can be
read in Auto Select mode using either the Programmer (see Table 8 and Table 9) or the Insystem method (see Table 10 and Table 11).
The extended memory block can only be accessed when the device is in Extended Memory
Block mode. For details of how the Extended Memory Block mode is entered and exited,
refer to the Section 6.3.1: Enter Extended Memory Block command and Section 6.3.2: Exit
Extended Memory Block command, and to Table 15 and Table 10.
C.1
Factory locked extended memory block
In devices where the extended memory block is factory locked, the security identification
number is written to the extended memory block address space (see Table 41: Extended
memory block address and data) in the factory. The DQ7 bit is set to ‘1’ and the extended
memory block cannot be unprotected.
87/94
Extended memory block
C.2
M29W128GH, M29W128GL
Customer lockable extended memory block
A device where the extended memory block is customer lockable is delivered with the DQ7
bit set to ‘0’ and the extended memory block unprotected. It is up to the customer to program
and protect the extended memory block but care must be taken because the protection of
the extended memory block is not reversible.
If the device has not been shipped with the extended memory block factory protected, the
block can be protected by setting the Extended Memory Block Protection bit, DQ0, to ‘0’.
However, this bit is one-time programmable and once protected the extended memory block
cannot be unprotected.
Once the extended memory block is programmed, the Exit Extended Memory Block
command must be issued to exit the Extended Memory Block mode and return the device to
Read mode.
Table 41.
Extended memory block address and data
Address(1)
Data
x8
x 16
Factory locked
Customer lockable
000000h-0000FFh
000000h-00007Fh
Security identification number
Determined by customer
1. See Table 34: Block addresses.
88/94
M29W128GH, M29W128GL
Appendix D
Flowcharts
Flowcharts
Figure 28. Write to Buffer Program flowchart and pseudocode
Start
Write to Buffer
command,
block address
Write n(1),
block address
First three cycles of the
Write to Buffer and Program command
Write Buffer Data,
start address
X=n
YES
X=0
NO
Abort Write
to Buffer
YES
Write to a different
block address
NO
Write Next Data,(3)
Program Address Pair
Write to Buffer and
Program Aborted(2)
X = X-1
Write to Buffer Program
Confirm, block address
Read Status Register
(DQ1, DQ5, DQ7) at
last loaded address
YES
DQ7 = Data
NO
NO
DQ1 = 1
NO
DQ5 = 1
YES
YES
Check Status Register
(DQ5, DQ7) at
last loaded address
DQ7 = Data
YES
(4)
NO
FAIL OR ABORT(5)
END
AI08968b
1. n+1 is the number of addresses to be programmed.
89/94
Flowcharts
M29W128GH, M29W128GL
2. A Write to Buffer Program Abort and Reset must be issued to return the device in Read mode.
3. When the block address is specified, any address in the selected block address space is acceptable. However when
loading write buffer address with data, all addresses must fall within the selected write buffer page.
4. DQ7 must be checked since DQ5 and DQ7 may change simultaneously.
5. If this flowchart location is reached because DQ5=’1’, then the Write to Buffer Program command failed. If this flowchart
location is reached because DQ1=’1’, then the Write to Buffer Program command aborted. In both cases, the appropriate
reset command must be issued to return the device in Read mode: a Reset command if the operation failed, a Write to
Buffer Program Abort and Reset command if the operation aborted.
6. See Table 10 and Table 11, for details on Write to Buffer Program command sequence.
90/94
M29W128GH, M29W128GL
Flowcharts
Figure 29. Enhanced Buffered Program flowchart and pseudocode
Start
Enhanced Buffered
Program command,
block address
First three cycles of the
Enhanced Buffered Program command
Write Buffer Data,
start address (00),
X=255
YES
X=0
NO
Abort Write
to Buffer
YES
Write to a different
block address
NO
Write Next Data,(2)
Program Address Pair
Enhanced Buffered
Program Aborted(1)
X = X-1
Enhanced Buffered
Program Confirm,
block address
Read Status Register
(DQ1, DQ5, DQ7) at
last loaded address
YES
DQ7 = Data
NO
NO
DQ1 = 1
YES
NO
DQ5 = 1
YES
Check Status Register
(DQ5, DQ7) at
last loaded address
DQ7 = Data
YES
(3)
NO
FAIL OR ABORT(4)
END
AI14243
1. A Buffered Program Abort and Reset must be issued to return the device in Read mode.
2. When the block address is specified, all the addresses in the selected block address space must be issued starting from
(00). Furthermore, when loading write buffer address with data, data program addresses must be consecutive.
3. DQ7 must be checked since DQ5 and DQ7 may change simultaneously.
4. If this flowchart location is reached because DQ5=’1’, then the Enhanced Buffered Program command failed. If this
flowchart location is reached because DQ1=’1’, then the Enhanced Buffered Program command aborted. In both cases, the
appropriate reset command must be issued to return the device in Read mode: a Reset command if the operation failed, a
91/94
Flowcharts
M29W128GH, M29W128GL
Buffered Program Abort and Reset command if the operation aborted.
5. See Table 14: Enhanced Buffered Program commands, 16-bit mode, for details on Enhanced Buffered Program command
sequence.
92/94
M29W128GH, M29W128GL
12
Revision history
Revision history
Table 42.
Document revision history
Date
Version
24-Nov-2006
0.1
Changes
Initial release.
1
VIO changed to VCCQ in the whole document and added in Table 21:
Absolute maximum ratings.
Chip Program time without VPPH updated in Features section.
RP signal acting as a Reset input, unprotection of all the blocks previously
protected using a High Voltage Block Protection technique removed.
Table 4: Bus operations, 8-bit mode and Table 5: Bus operations, 16-bit
mode updated. Table 6: Read electronic signature - auto select mode programmer method (8-bit mode) and Table 7: Read electronic signature auto select mode - programmer method (16-bit mode) updated. Table 8:
Block protection - auto select mode - programmer method (8-bit mode)
and Table 9: Block protection - auto select mode - programmer method
(16-bit mode) updated.
Section 5: Software protection added, together with the related
commands.
Unlock Bypass Block Erase, Unlock Bypass Chip Erase, and Unlock Write
to Buffer and Program commands added.
Lock Register description added in Section 7.1.
2
Enhanced Buffered Program commands added (see on page1 and from
Section 6.2.2 to Section 6.2.12).
Modified values for page access, random access, programming time, and
chip program time on page 1. Speed classes changed in Table 27,
Table 28, Table 29, Table 30, and Table 33.
Table 14: Enhanced Buffered Program commands, 16-bit mode added.
Table 12, Table 13, Table 15, Table 16, Table 17, Table 22, Table 26,
Table 37, and Table 39 updated as well as Figure 22.
Figure 29: Enhanced Buffered Program flowchart and pseudocode added
in Appendix D.
28-Jan-2008
3
Document status promoted from preliminary data to datasheet.
Speed classes and page size modified on page 1.
Modified: Section 2.8: VPP/Write Protect (VPP/WP), Section 3.6:
Automatic Standby, Section 6.1.5: Block Erase command, Table 3:
VPP/WP functions, Table 22: Operating and AC measurement conditions,
Table 25: DC characteristics, and Table 39: Primary algorithm-specific
extended query table.
Added: Table 23: Power-up waiting timings and Figure 12: Power-up
waiting timings.
Changed Erase Suspend latency time in Table 17: Program, Erase times
and Program, Erase endurance cycles.
Minor text changes.
20-Mar-2008
4
Applied Numonyx branding.
30-Mar-2007
23-Oct-2007
93/94
M29W128GH, M29W128GL
Please Read Carefully:
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYX™ PRODUCTS. NO LICENSE, EXPRESS OR
IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT
AS PROVIDED IN NUMONYX'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY
WHATSOEVER, AND NUMONYX DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF
NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE,
MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
Numonyx products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility
applications.
Numonyx may make changes to specifications and product descriptions at any time, without notice.
Numonyx, B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the
presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied,
by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights.
Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Numonyx reserves
these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an order number and are referenced in this document, or other Numonyx literature may be obtained by
visiting Numonyx's website at http://www.numonyx.com.
Numonyx StrataFlash is a trademark or registered trademark of Numonyx or its subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 11/5/7, Numonyx, B.V., All Rights Reserved.
94/94
Similar pages