Switching Power Supplies МАА Series MAA50 Ordering information МАА 50 – 3 S 05 15 15 S U N c d efg h ijkl c d e f g h i j k l • • • • • • • • • - MAA Series - Nominal output power, Watt - Channel quantity (1, 2, 3) - - Input voltage S – 220VAC K – 115VAC - Output voltage channel 1, VDC - Output voltage channel 2, VDC - Output voltage channel 3, VDC - Execution with sealing - Embodiment B – uniform case with priming - Operating temperature range of case N - - 40°С…+85°С P - - 50°С…+85°С Rugged environment in operation in technical equipment of industrial and special purpose. Low-profile construction Metal case Cooling by heat sink or free air convection Electromagnetic compatibility index to GOST V 25803-91 for group 1.2.1 (curve 2) Stability to external factors of group 1U GOST RV 20.39.414.1-97 (additional) Short circuit protection, overload, overvoltage and thermal protection Galvanic isolated outputs Acceptance «5» Single-output models МАА501S03SХХ 26,4 W МАА501S05SХХ 40 W МАА501S12SХХ МАА501S15SХХ Output voltage 3,3 VDC 5 VDC 12 VDC 15 VDC 24 VDC Output current 8A 8А 4,17 А 3,33 А 2,27 А Module Output power МАА50МАА501S24SХХ 1S27SХХ 50 W МАА501S48SХХ МАА501S68SХХ 27 VDC 48 VDC 68 VDC 1,85 А 1,04 А 0,73 А Dual-output models Module МАА50-2S0505SХХ МАА50-2S1212SХХ Output power Channel number Output voltage Output current МАА50-2S1515SХХ 50 W 1 2 1 2 1 2 5 VDC 5А 5 VDC 5А 12 VDC 2,1 А 12 VDC 2,1 А 15 VDC 15 VDC 1,67 А 1,67 А Triple-output models Module МАА50-3S051212SХХ МАА50-3S051515SХХ Output power Channel number 50 W 1 2 3 1 2 3 Output voltage 5 VDC 12 VDC 12 VDC 5 VDC 15 VDC 15 VDC Output current 5А 1,04А 1,04А 5А 0,83 А 0,83 А by request can be delivered modules with non-standard output voltage from 3 to 70 VDC and maximal output current to 8А. http://www.aedon.ru e-mail: [email protected] tel/fax (4732) 519-518 © “Alexander Electric” holding. All rights reserved. http://www.aeps-group.com e-mail: [email protected] tel/fax +420-266-107-609 Switching Power Supplies МАА Series MAA50 Input specifications Parameter Conditions of dimensions S К S К S К Steady-state deviation Input voltage Transient deflection, 1 sec Input frequency Output specifications Parameter Conditions of dimensions Single-output execution (Inom 10 – 100%) Uout2&3 Output 1 multi-output execution differs from (Inom 10 – 100%) Uout1 less Output 2 and 3 multi-output execution than 20% (Inom 10 – 100%) Output 1 multi-output execution Uout2&3 (Inom 30 – 100%) differs from Uout1 more Output 2 and 3 multi-output execution than 20% (Inom 50-100%) Total output voltage instability Output voltage pulsations ripple (peak-to-peak) Current overload protection actuation level Short circuit protection Overvoltage protection Thermal protection General specifications Parameter NOM 220 115 MAX 242 140 264 150 Unit VAC VAC VAC VAC 47 400 440 Hz MIN NOM MAX ±3 Unit % ±3 % ±13 % ±3 % ±15 % 2 % Uout.nom. Dimension by device for pulsation control Autorepair Conditions of dimensions N P - operating of case Temperature MIN 187 80 176 80 – power loss – storage 110 % Iout.nom. 150 120 90-95 % Iout.nom. % Uout.nom. °C MIN – 40 – 50 NOM MAX +85 +85 Unit +85 °C % kHz VAC VAC VDC VDC Ohm % °C ms Hz Pa hour kg °C See diagram – 50 Efficiency Conversion frequency 78 50 ~ in/out ~ in/case ~ out/case ~ out/out Isolation 1500 1500 500 500 20 Insulation resistance Voltage 500VDC High humidity Temperature 35°С Cyclic overpatching of temperature – 60 Multiple mechanical shocks Speeding-up 15g 2 Sinusoidal vibration Speeding-up 5g 50 Atmosphere pressure 6х104 Time to failure Temperature 35°C 105 Mass all specifications redused for normal climatic conditions, Uin.nom., Iout.nom., if it is not specified differently. 98 +85 15 500 1,2х105 0,4 Power loss diagram Output power, W Выходная мощность, Вт 60 With heat sink 50 40 30 Free air convection 20 10 0 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 Температура среды °C Токр, С Ambientокружающей temperature Tamb, http://www.aedon.ru e-mail: [email protected] tel/fax (4732) 519-518 © “Alexander Electric” holding. All rights reserved. 80 90 http://www.aeps-group.com e-mail: [email protected] tel/fax +420-266-107-609 Switching Power Supplies МАА Series MAA50 Output settings № pin Single-channel 1 case 2 ~IN (N) 3 ~IN (L) 4 +out1 5 +out1 6 +out1 7 -out1 8 -out1 9 -out1 Dual-channel case ~IN (N) ~IN (L) +out1 +out1 -out1 -out1 -out2 +out2 Triple-channel case ~IN (N) ~IN (L) -out3 +out3 +out1 -out1 -out2 +out2 Switching on standart diagram ~In (L) ~In (N) FUin ~In (L) ~In (N) +Out Power module ground Case Rheat Сout1 Сout2 -Out FUin – current safety device 1A for input voltage 220VAC, 2A for input voltage 115VAC. Sout – ceramic condenser capacity 0,47-15 mcF with corresponding operating voltage to decrease high-frequency noise level. Sout2 – electronic condenser capacity 22-100 mcF in consideration with operating voltage and polarity. It makes for purpose to decrease dynamic instability when module work at dynamic load. http://www.aedon.ru e-mail: [email protected] tel/fax (4732) 519-518 © “Alexander Electric” holding. All rights reserved. http://www.aeps-group.com e-mail: [email protected] tel/fax +420-266-107-609 Switching Power Supplies МАА Series MAA50 Single, Dual, and Triple-output execution SBN http://www.aedon.ru e-mail: [email protected] tel/fax (4732) 519-518 © “Alexander Electric” holding. All rights reserved. http://www.aeps-group.com e-mail: [email protected] tel/fax +420-266-107-609 Switching Power Supplies МАА Series MAA50 Single, Dual, and Triple-output execution SVN (with flexible erection joints) The Flexible erection fjoints by length (100±5)mm is executed by wire section (0,5...1,5)mm2. http://www.aedon.ru e-mail: [email protected] tel/fax (4732) 519-518 © “Alexander Electric” holding. All rights reserved. http://www.aeps-group.com e-mail: [email protected] tel/fax +420-266-107-609