ETC2 MAA50-2S480515SBN Switching power supply Datasheet

Switching Power Supplies
МАА Series MAA50
Ordering information
МАА 50 – 3 S 05 15 15 S U N
c d efg h ijkl
c
d
e
f
g
h
i
j
k
l
•
•
•
•
•
•
•
•
•
- MAA Series
- Nominal output power, Watt
- Channel quantity (1, 2, 3)
- - Input voltage
S – 220VAC
K – 115VAC
- Output voltage channel 1, VDC
- Output voltage channel 2, VDC
- Output voltage channel 3, VDC
- Execution with sealing
- Embodiment
B – uniform case with priming
- Operating temperature range of case
N - - 40°С…+85°С
P - - 50°С…+85°С
Rugged environment in operation in
technical equipment of industrial and special purpose.
Low-profile construction
Metal case
Cooling by heat sink or free air convection
Electromagnetic compatibility index to GOST V 25803-91 for group 1.2.1 (curve 2)
Stability to external factors of group 1U GOST RV 20.39.414.1-97 (additional)
Short circuit protection, overload, overvoltage and thermal protection
Galvanic isolated outputs
Acceptance «5»
Single-output models
МАА501S03SХХ
26,4 W
МАА501S05SХХ
40 W
МАА501S12SХХ
МАА501S15SХХ
Output voltage
3,3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
Output current
8A
8А
4,17 А
3,33 А
2,27 А
Module
Output power
МАА50МАА501S24SХХ
1S27SХХ
50 W
МАА501S48SХХ
МАА501S68SХХ
27 VDC
48 VDC
68 VDC
1,85 А
1,04 А
0,73 А
Dual-output models
Module
МАА50-2S0505SХХ
МАА50-2S1212SХХ
Output power
Channel number
Output voltage
Output current
МАА50-2S1515SХХ
50 W
1
2
1
2
1
2
5 VDC
5А
5 VDC
5А
12 VDC
2,1 А
12 VDC
2,1 А
15 VDC
15 VDC
1,67 А
1,67 А
Triple-output models
Module
МАА50-3S051212SХХ
МАА50-3S051515SХХ
Output power
Channel number
50 W
1
2
3
1
2
3
Output voltage
5 VDC
12 VDC
12 VDC
5 VDC
15 VDC
15 VDC
Output current
5А
1,04А
1,04А
5А
0,83 А
0,83 А
‘ by request can be delivered modules with non-standard output voltage from 3 to 70 VDC and maximal output current to 8А.
http://www.aedon.ru
e-mail: [email protected]
tel/fax (4732) 519-518
© “Alexander Electric” holding.
All rights reserved.
http://www.aeps-group.com
e-mail: [email protected]
tel/fax +420-266-107-609
Switching Power Supplies
МАА Series MAA50
Input specifications
Parameter
Conditions of dimensions
S
К
S
К
S
К
Steady-state deviation
Input voltage
Transient deflection, 1 sec
Input frequency
Output specifications
Parameter
Conditions of dimensions
Single-output execution (Inom 10 – 100%)
Uout2&3
Output 1 multi-output execution
differs from
(Inom 10 – 100%)
Uout1 less
Output 2 and 3 multi-output execution
than 20%
(Inom 10 – 100%)
Output 1 multi-output execution
Uout2&3
(Inom 30 – 100%)
differs from
Uout1 more
Output 2 and 3 multi-output execution
than 20%
(Inom 50-100%)
Total output voltage instability
Output voltage pulsations ripple
(peak-to-peak)
Current overload protection
actuation level
Short circuit protection
Overvoltage protection
Thermal protection
General specifications
Parameter
NOM
220
115
MAX
242
140
264
150
Unit
VAC
VAC
VAC
VAC
47
400
440
Hz
MIN
NOM
MAX
±3
Unit
%
±3
%
±13
%
±3
%
±15
%
2
% Uout.nom.
Dimension by device for pulsation control
Autorepair
Conditions of dimensions
N
P
- operating of case
Temperature
MIN
187
80
176
80
– power loss
– storage
110
% Iout.nom.
150
120
90-95
% Iout.nom.
% Uout.nom.
°C
MIN
– 40
– 50
NOM
MAX
+85
+85
Unit
+85
°C
%
kHz
VAC
VAC
VDC
VDC
Ohm
%
°C
ms
Hz
Pa
hour
kg
°C
See diagram
– 50
Efficiency
Conversion frequency
78
50
~ in/out
~ in/case
~ out/case
~ out/out
Isolation
1500
1500
500
500
20
Insulation resistance
Voltage 500VDC
High humidity
Temperature 35°С
Cyclic overpatching of temperature
– 60
Multiple mechanical shocks
Speeding-up 15g
2
Sinusoidal vibration
Speeding-up 5g
50
Atmosphere pressure
6х104
Time to failure
Temperature 35°C
105
Mass
‘ all specifications redused for normal climatic conditions, Uin.nom., Iout.nom., if it is not specified differently.
98
+85
15
500
1,2х105
0,4
Power loss diagram
Output power,
W
Выходная
мощность,
Вт
60
With heat sink
50
40
30
Free air
convection
20
10
0
-50 -40 -30 -20 -10 0
10 20 30 40 50 60 70
Температура
среды °C
Токр, С
Ambientокружающей
temperature Tamb,
http://www.aedon.ru
e-mail: [email protected]
tel/fax (4732) 519-518
© “Alexander Electric” holding.
All rights reserved.
80
90
http://www.aeps-group.com
e-mail: [email protected]
tel/fax +420-266-107-609
Switching Power Supplies
МАА Series MAA50
Output settings
№ pin
Single-channel
1
case
2
~IN (N)
3
~IN (L)
4
+out1
5
+out1
6
+out1
7
-out1
8
-out1
9
-out1
Dual-channel
case
~IN (N)
~IN (L)
+out1
+out1
-out1
-out1
-out2
+out2
Triple-channel
case
~IN (N)
~IN (L)
-out3
+out3
+out1
-out1
-out2
+out2
Switching on standart diagram
~In (L)
~In (N)
FUin
~In (L)
~In (N)
+Out
Power module
ground
Case
Rheat
Сout1
Сout2
-Out
‘ FUin – current safety device 1A for input voltage 220VAC, 2A for input voltage 115VAC.
‘ Sout – ceramic condenser capacity 0,47-15 mcF with corresponding operating voltage to decrease high-frequency noise level.
‘ Sout2 – electronic condenser capacity 22-100 mcF in consideration with operating voltage and polarity. It makes for purpose
to decrease
dynamic instability when module work at dynamic load.
http://www.aedon.ru
e-mail: [email protected]
tel/fax (4732) 519-518
© “Alexander Electric” holding.
All rights reserved.
http://www.aeps-group.com
e-mail: [email protected]
tel/fax +420-266-107-609
Switching Power Supplies
МАА Series MAA50
Single, Dual, and Triple-output execution SBN
http://www.aedon.ru
e-mail: [email protected]
tel/fax (4732) 519-518
© “Alexander Electric” holding.
All rights reserved.
http://www.aeps-group.com
e-mail: [email protected]
tel/fax +420-266-107-609
Switching Power Supplies
МАА Series MAA50
Single, Dual, and Triple-output execution SVN (with flexible erection joints)
The Flexible erection fjoints by length (100±5)mm is executed by wire section (0,5...1,5)mm2.
http://www.aedon.ru
e-mail: [email protected]
tel/fax (4732) 519-518
© “Alexander Electric” holding.
All rights reserved.
http://www.aeps-group.com
e-mail: [email protected]
tel/fax +420-266-107-609
Similar pages