021 ASM www.vishay.com Vishay BCcomponents Aluminum Capacitors Axial Standard Miniature FEATURES • • • • • 041/043 ASH • • • high voltage 117 ASD lower CV-values longer life 105 °C 021 ASM 138 AML Fig. 1 QUICK REFERENCE DATA DESCRIPTION Nominal case sizes (Ø D x L in mm) Rated capacitance range, CR Tolerance on CR Rated voltage range, UR Category temperature range Endurance test at 85 °C: UR = 6.3 V to 25 V UR = 40 V to 100 V Endurance test at 105 °C Useful life at 85 °C Useful life at 40 °C, 1.4 x IR applied Shelf life at 0 V, 85 °C Based on sectional specification Climatic category IEC 60068 VALUE 4.5 x 10 10 x 30 to 10 x 25 to 21 x 38 0.47 μF to 15 000 μF ± 20 % 6.3 V to 100 V - 40 °C to + 85 °C 1000 h 2000 h 2500 h 5000 h 5000 h 2000 h 8000 h 70 000 h 200 000 h 500 h IEC 60384-4/EN130300 40/085/56 Long useful life: 2500 h to 8000 h at 85 °C Miniaturized, high CV-product per unit volume Charge and discharge proof Taped versions up to case Ø 15 mm x 30 mm available for automatic insertion Polarized aluminum electrolytic capacitors, non-solid electrolyte Axial leads, cylindrical aluminum case, insulated with a blue sleeve Mounting ring version not available in insulated form Material categorization: For definitions of compliance please see www.vishay.com/doc?99912 APPLICATIONS • • • • General purpose, industrial, automotive, audio-video Coupling, decoupling, smoothing, filtering, buffering Portable and mobile equipment (small size, low mass) Low mounting height boards, vibration and shock resistant MARKING The capacitors are marked (where possible) with the following information: • Rated capacitance (in μF) • Tolerance on rated capacitance, code letter in accordance with IEC 60062 (M for ± 20 %) • Rated voltage (in V) • Upper category temperature (85 °C) • Date code in accordance with IEC 60062 • Code for factory of origin • Name of manufacturer • Negative terminal identification • Series number (021) SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (Ø D x L in mm) CR (μF) 0.47 1.0 2.2 3.3 4.7 10 15 22 33 47 Revision: 24-Oct-12 6.3 - 10 - 16 - UR (V) 25 4.5 x 10 - 40 4.5 x 10 6 x 10 - 63 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 6 x 10 6 x 10 8 x 11 6.5 x 18 100 4.5 x 10 4.5 x 10 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 11 6.5 x 18 6.5 x 18 8 x 18 - Document Number: 28325 1 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 021 ASM www.vishay.com Vishay BCcomponents SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (Ø D x L in mm) CR (μF) 68 100 150 220 330 470 680 1000 1500 2200 3300 4700 6800 10 000 15 000 6.3 8 x 11 8 x 18 10 x 25 - 10 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 UR (V) 25 6 x 10 8 x 11 6.5 x 18 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 - 16 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 - 40 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 - 63 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 - 100 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 - DIMENSIONS in millimeters AND AVAILABLE FORMS 63.5 ± 1.5 ØD 73 ± 1.6 L ØD L Ød Ød + F F Form BR: Taped on reel Case Ø D x L = 6.5 mm x 18 mm to 15 mm x 30 mm Form BR: Taped on reel Form BA: Taped in box (ammopack) Case Ø D x L = 4.5 mm x 10 mm to 8 mm x 11 mm Form BA: Taped in box (ammopack) Case Ø D x L = 6.5 mm x 18 mm to 10 mm x 25 mm Fig. 2 - Forms BA and BR Fig. 3 - Forms BA and BR I L 33 ± 1 Ød ØD F Form AA: Axial in box Case Ø D x L = 10 mm x 30 mm to 21 mm x 38 mm Fig. 4 - Form AA Revision: 24-Oct-12 Document Number: 28325 2 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 021 ASM www.vishay.com Vishay BCcomponents Table 1 AXIAL; DIMENSIONS in millimeters, MASS AND PACKAGING QUANTITIES NOMINAL CASE SIZE ØDxL CASE CODE AXIAL: FORM AA, BA, AND BR Ød I Ø Dmax. Lmax. Fmin. PACKAGING QUANTITIES MASS (g) FORM AA FORM BA FORM BR 4.5 x 10 2 0.6 - 5.0 10.5 15 0.5 - 1000 3000 6 x 10 3 0.6 - 6.3 10.5 15 0.7 - 1000 1000 8 x 11 5a 0.6 - 8.5 11.5 15 1.1 - 500 500 6.5 x 18 4 0.8 - 6.9 18.5 25 1.3 - 1000 1000 8 x 18 5 0.8 - 8.5 18.5 25 1.7 - 500 500 10 x 18 6 0.8 - 10.5 18.5 25 2.5 - 500 500 10 x 25 7 0.8 - 10.5 25.5 30 3.3 - 500 500 10 x 30 00 0.8 55 ± 1 10.5 30.5 35 4.8 340 - 500 12.5 x 30 01 0.8 55 ± 1 13.0 30.5 35 7.4 260 - 400 15 x 30 02 0.8 55 ± 1 15.5 30.5 35 11.7 200 - 250 18 x 30 03 0.8 55 ± 1 18.5 30.5 35 12.9 120 - - 18 x 38 04 0.8 34 ± 1 18.5 39.5 44 19.0 125 - - 21 x 38 05 0.8 34 ± 1 21.5 39.5 44 24.0 100 - - Note • For detailed tape dimensions, please see www.vishay.com/doc?28361. D 120° (3 x) 3.6 D3 90° ± 2° (3 x) 1.3 + 0.2 - 0.4 L + 0.03 1.05 - 0.1 (3 x) 0 (3 x) 1.3 - 0.05 + 0.1(3 x) 0 Mounting holes + 1.0 1 - 0.5 Form MR: Case Ø D x L = 15 mm x 30 mm to 21 mm x 38 mm Especially for applications with severe shocks and vibrations Ø d1 Ø D2 Fig. 5 - Mounting hole diagram and outline. Form MR: With mounting ring and pins Table 2 MOUNTING RING; DIMENSIONS in millimeters, MASS AND PACKAGING QUANTITIES NOMINAL CASE SIZE ØDxL CASE CODE MOUNTING RING: FORM MR Ø d1 Ø d2 Ø D2max. D3 Lmax. MASS (g) PACKAGING QUANTITIES 15 x 30 02 0.8 1.0 + 0.4 17.5 16.5 ± 0.2 33 11.7 200 18 x 30 03 0.8 1.0 + 0.4 19.5 18.5 ± 0.2 33 12.9 240 18 x 38 04 0.8 1.0 + 0.4 19.5 18.5 ± 0.2 42 19.0 100 21 x 38 05 0.8 1.0 + 0.4 22.5 21.5 ± 0.2 42 24.0 100 Revision: 24-Oct-12 Document Number: 28325 3 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 021 ASM www.vishay.com Vishay BCcomponents ORDERING EXAMPLE ELECTRICAL DATA SYMBOL CR IR IL5 tan ESR Electrolytic capacitor 021 series DESCRIPTION Rated capacitance at 100 Hz, tolerance ± 20 % Rated RMS ripple current at 100 Hz, 85 °C Max. leakage current after 5 min at UR Max. dissipation factor at 100 Hz Equivalent series resistance at 100 Hz (calculated from tan max. and CR) Max. impedance at 10 kHz 1000 μF/16 V; ± 20 % Nominal case size: Ø 10 mm x 25 mm; Form BA Ordering code: MAL202190518E3 Former 12 NC: 2222 021 90518 Z Note • Unless otherwise specified, all electrical values in Table 3 apply at Tamb = 20 °C, P = 86 kPa to 106 kPa, RH = 45 % to 75 %. Table 3 ELECTRICAL DATA AND ORDERING INFORMATION UR (V) 6.3 10 16 25 CR 100 Hz (μF) NOMINAL CASE SIZE ØDxL (mm) IR 100 Hz 85 °C (mA) IL5 5 min (μA) tan 100 Hz ESR 100 Hz () Z 10 kHz () 470 1000 2200 100 220 330 470 680 1000 1500 1500 2200 3300 4700 6800 10 000 15 000 68 150 220 330 470 680 1000 1000 1500 2200 3300 4700 6800 10 000 47 100 150 150 220 330 470 680 680 1000 1500 2200 3300 4700 6800 8 x 11 8 x 18 10 x 25 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 4.5 x 10 6 x 10 8 x 11 6.5 x 18 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 260 440 710 100 160 230 310 400 550 690 740 980 1090 1320 1590 2090 2250 90 140 210 290 380 500 660 700 950 1040 1290 1560 2040 2170 80 150 190 210 250 340 450 560 640 840 950 1180 1470 1920 2070 10 17 32 6 8.4 11 13 18 24 34 34 48 70 98 140 204 304 6.2 8.8 11 15 19 26 36 36 52 74 110 154 222 324 6.4 9 12 12 15 21 28 38 38 54 79 114 169 239 344 0.25 0.25 0.29 0.20 0.20 0.20 0.20 0.20 0.20 0.23 0.23 0.25 0.27 0.29 0.34 0.40 0.50 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.19 0.21 0.23 0.25 0.30 0.36 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.17 0.19 0.21 0.23 0.28 0.850 0.400 0.210 3.200 1.500 1.000 0.680 0.470 0.320 0.250 0.245 0.177 0.128 0.100 0.079 0.064 0.054 3.800 1.700 1.200 0.770 0.550 0.380 0.260 0.260 0.205 0.150 0.111 0.087 0.070 0.058 4.800 2.300 1.500 1.500 1.000 0.680 0.480 0.330 0.323 0.220 0.179 0.132 0.099 0.079 0.064 0.640 0.500 0.160 2.000 0.910 0.610 0.430 0.290 0.200 0.180 0.180 0.095 0.095 0.070 0.065 0.040 0.035 2.400 1.100 0.730 0.480 0.340 0.240 0.180 0.175 0.095 0.095 0.070 0.065 0.040 0.035 2.600 1.200 0.800 0.800 0.550 0.360 0.260 0.180 0.175 0.095 0.095 0.070 0.065 0.040 0.035 Revision: 24-Oct-12 ORDERING CODE MAL2021....... TAPED TAPED MOUNTING ON REEL IN BOX RING FORM FORM FORM BR BA MR 23471E3 33471E3 23102E3 33102E3 90588E3 90589E3 24101E3 34101E3 24221E3 34221E3 24331E3 34331E3 24471E3 34471E3 24681E3 34681E3 24102E3 34102E3 90524E3 90525E3 14152E3 24152E3 14222E3 24222E3 14332E3 24332E3 14472E3 24472E3 44472E3 14682E3 44682E3 14103E3 44103E3 14153E3 44153E3 25689E3 35689E3 25151E3 35151E3 25221E3 35221E3 25331E3 35331E3 25471E3 35471E3 25681E3 35681E3 90517E3 90518E3 15102E3 25102E3 15152E3 25152E3 15222E3 25222E3 15332E3 25332E3 45332E3 15472E3 45472E3 15682E3 45682E3 15103E3 45103E3 26479E3 36479E3 26101E3 36101E3 90534E3 90535E3 26151E3 36151E3 26221E3 36221E3 26331E3 36331E3 26471E3 36471E3 90527E3 90528E3 16681E3 26681E3 16102E3 26102E3 16152E3 26152E3 16222E3 26222E3 46222E3 16332E3 46332E3 16472E3 46472E3 16682E3 46682E3 IN BOX FORM AA Document Number: 28325 4 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 021 ASM www.vishay.com Vishay BCcomponents ELECTRICAL DATA AND ORDERING INFORMATION UR (V) 40 63 100 CR 100 Hz (μF) NOMINAL CASE SIZE ØDxL (mm) IR 100 Hz 85 °C (mA) IL5 5 min (μA) 22 47 100 100 150 220 330 470 470 680 1000 1500 2200 3300 4700 0.47 1 2.2 3.3 4.7 10 15 22 33 47 47 68 68 100 150 220 220 330 470 680 1000 1500 2200 1 2.2 4.7 10 15 15 22 22 33 47 68 100 100 150 220 330 470 680 1000 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 4.5 x 10 6 x 10 6 x 10 8 x 11 6.5 x 18 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 4.5 x 10 4.5 x 10 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 11 6.5 x 18 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 60 110 170 190 250 330 430 520 590 800 900 1120 1390 1810 1940 8 12 21 25 31 50 55 90 100 140 150 160 170 250 320 430 480 610 700 890 1170 1530 1780 14 20 30 65 77 85 95 100 120 160 220 300 340 490 560 740 980 1260 1470 5.8 7.8 12 12 16 22 30 42 42 58 84 124 180 268 380 4.1 4.1 4.3 4.4 4.6 5.3 5.9 6.8 8.2 10 10 13 13 17 23 32 32 46 63 90 130 193 281 4.2 4.4 4.9 6 7 7 8.4 8.4 10.6 13.4 17.6 24 24 34 48 70 98 140 204 Revision: 24-Oct-12 tan 100 Hz ESR 100 Hz () Z 10 kHz () 0.11 0.11 0.11 0.11 0.11 0.11 0.11 0.11 0.12 0.12 0.12 0.15 0.17 0.19 0.21 0.09 0.09 0.09 0.09 0.09 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.11 0.13 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07 0.07 0.08 0.09 0.09 0.09 0.10 8.000 3.800 1.800 1.800 1.100 0.800 0.530 0.370 0.404 0.297 0.190 0.159 0.118 0.090 0.072 310.0 150.0 65.00 44.00 31.00 13.00 8.500 5.800 3.900 2.700 2.700 1.900 1.900 1.300 0.850 0.600 0.614 0.409 0.287 0.199 0.135 0.122 0.099 130.0 58.00 27.00 13.00 8.500 8.500 5.800 5.800 3.900 2.700 1.900 1.300 1.150 0.645 0.610 0.420 0.310 0.195 0.160 3.200 1.500 0.700 0.700 0.470 0.320 0.210 0.180 0.175 0.110 0.110 0.070 0.065 0.040 0.035 120.0 55.00 25.00 17.00 12.00 5.500 3.700 2.500 1.700 1.200 1.200 0.810 0.810 0.550 0.370 0.250 0.260 0.190 0.130 0.095 0.075 0.045 0.040 90.00 41.00 19.00 9.000 6.000 6.000 4.100 4.100 2.700 1.900 1.300 0.900 1.000 0.610 0.560 0.400 0.290 0.180 0.150 ORDERING CODE MAL2021....... TAPED TAPED MOUNTING IN BOX ON REEL IN BOX RING FORM FORM FORM FORM AA BR BA MR 27229E3 37229E3 27479E3 37479E3 90537E3 90538E3 27101E3 37101E3 27151E3 37151E3 27221E3 37221E3 27331E3 37331E3 90514E3 90515E3 17471E3 27471E3 17681E3 27681E3 17102E3 27102E3 17152E3 27152E3 47152E3 17222E3 47222E3 17332E3 47332E3 17472E3 47472E3 28477E3 38477E3 28108E3 38108E3 28228E3 38228E3 28338E3 38338E3 28478E3 38478E3 28109E3 38109E3 28159E3 38159E3 28229E3 38229E3 28339E3 38339E3 90541E3 90542E3 28479E3 38479E3 90544E3 90545E3 28689E3 38689E3 28101E3 38101E3 28151E3 38151E3 90511E3 90512E3 18221E3 28221E3 18331E3 28331E3 18471E3 28471E3 18681E3 28681E3 48681E3 18102E3 48102E3 18152E3 48152E3 18222E3 48222E3 29108E3 39108E3 29228E3 39228E3 29478E3 39478E3 29109E3 39109E3 90547E3 90548E3 29159E3 39159E3 90551E3 90552E3 29229E3 39229E3 29339E3 39339E3 29479E3 39479E3 29689E3 39689E3 90531E3 90532E3 19101E3 29101E3 19151E3 29151E3 19221E3 29221E3 19331E3 29331E3 49331E3 19471E3 49471E3 19681E3 49681E3 19102E3 49102E3 Document Number: 28325 5 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 021 ASM www.vishay.com Vishay BCcomponents ADDITIONAL ELECTRICAL DATA PARAMETER VALUE CONDITIONS AXIAL MOUNTING RING Voltage Surge voltage Reverse voltage Current Us 1.15 x UR Urev 1 V IL1 0.006 CR x UR + 4 μA IL5 0.002 CR x UR + 4 μA After 1 min at UR After 5 min at UR Leakage current Inductance Equivalent series inductance (ESL) Case Ø D x L mm: 4.5 x 10 6 x 10 8 x 11 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 12.5 x 30 15 x 30 18 x 30 18 x 38 21 x 38 Typ. 10 nH Typ. 22 nH Typ. 85 nH Typ. 25 nH Typ. 40 nH Typ. 61 nH Typ. 38 nH Typ. 38 nH Typ. 46 nH Typ. 48 nH Typ. 50 nH Typ. 54 nH Typ. 59 nH Typ. 39 nH Typ. 39 nH Typ. 39 nH Typ. 39 nH RIPPLE CURRENT AND USEFUL LIFE CCC205 3.3 IA 3.2 IR 3.1 3.0 2.8 2.6 2.4 Lifetime multiplier 2.2 0 1. 5 1. 2.0 0 2. 1.8 0 3. 0 4. 1.6 0 6. 15 70 0.5 0.0 (1) 30 1.0 0.8 50 Useful life at 85 °C and IR applied: Case Ø D x L = 4.5 mm x 10 mm to 10 mm x 25 mm: 2500 h Case Ø D x L = 10 mm x 30 mm to 21 mm x 38 mm: 8000 h 1.2 20 (1) 10 1.4 IA = Actual ripple current at 100 Hz IR = Rated ripple current at 100 Hz, 85 °C 40 50 60 70 80 90 100 Tamb (°C) Fig. 6 - Multiplier of useful life as a function of ambient temperature and ripple current load Revision: 24-Oct-12 Document Number: 28325 6 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 021 ASM www.vishay.com Vishay BCcomponents Table 4 MULTIPLIER OF RIPPLE CURRENT (IR) AS A FUNCTION OF FREQUENCY IR MULTIPLIER FREQUENCY (Hz) UR = 6.3 V TO 16 V UR = 25 V TO 40 V UR = 63 V TO 100 V 50 0.95 0.90 0.85 100 1.00 1.00 1.00 300 1.07 1.12 1.20 1000 1.12 1.20 1.30 3000 1.15 1.25 1.35 10 000 1.20 1.30 1.40 Table 5 TEST PROCEDURES AND REQUIREMENTS TEST NAME OF TEST Endurance REFERENCE IEC 60384-4/ EN130300 subclause 4.13 PROCEDURE (quick reference) Tamb = 85 °C; UR applied; case Ø D x L = 4.5 mm x 10 mm to 10 mm x 25 mm: UR = 6.3 V to 25 V: 1000 h; UR = 40 V to 100 V: 2000 h; case Ø D x L = 10 mm x 30 m to 21 mm x 38 mm: UR = 6.3 V to 100 V: 5000 h UR 6.3 V; C/C: + 15 %/- 30 % UR > 6.3 V; C/C: ± 15 % tan 1.3 x spec. limit Z 2 x spec. limit IL5 spec. limit Tamb = 105 °C; UR applied; case Ø D x L = 10 mm x 30 mm to 21 mm x 38 mm: 2000 h C/C: ± 20 % tan 1.6 x spec. limit Z 2 x spec. limit IL5 spec. limit UR 6.3 V; C/C: + 45 %/- 50 % UR > 6.3 V; C/C: ± 45 % tan 3 x spec. limit Z 3 x spec. limit IL5 spec. limit no short or open circuit total failure percentage: 1 % C/C, tan , Z: for requirements see “Endurance test” above IL5 2 x spec. limit Useful life CECC 30301 subclause 1.8.1 Tamb = 85 °C; UR and IR applied; case Ø D x L = 4.5 mm x 10 mm to 10 mm x 25 mm: 2500 h; case Ø D x L = 10 mm x 30 mm to 21 mm x 38 mm: 8000 h Shelf life (storage at high temperature) IEC 60384-4/ EN130300 subclause 4.17 Tamb = 85 °C; no voltage applied; 500 h after test: UR to be applied for 30 min, 24 h to 48 h before measurement Revision: 24-Oct-12 REQUIREMENTS Document Number: 28325 7 For technical questions, contact: [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000