Maxim MAX6464UR Ultra-low-power voltage detectors and up supervisory circuit Datasheet

19-2533; Rev 2; 12/05
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
The MAX6461–MAX6466 family of ultra-low-power voltage
detectors and µP reset supervisory circuits monitors battery, power-supply, and system voltages. Each circuit
includes a precision bandgap reference, a comparator,
internally trimmed resistor networks that set specified trip
thresholds, and an internal 5% threshold hysteresis circuit
(see the Functional Diagram). Output is asserted when
VCC falls below the internal VTH- and remains asserted
until VCC rises above VTH+ (VTH+ = VTH- × 1.05). These
devices provide excellent circuit reliability and low cost
by eliminating external components and adjustments
when monitoring nominal system voltages from +1.6V to
+5.5V. The MAX6461/MAX6462/MAX6463 are voltage
detectors with a propagation delay of 17µs.
The MAX6464/MAX6465/MAX6466 are µP supervisory
circuits with a minimum reset timeout period of 150ms. All
devices are available with thresholds from +1.6V to +5.5V
in 100mV increments.
The family is available with three output stage options:
push-pull with active-low output, push-pull with activehigh output, and open drain with active-low output. These
devices are available in SC70 and SOT23 packages
specified over the -40°C to +125°C temperature range.
Applications
Precision Battery Monitoring
Features
♦ Ultra-Low 1.0µA Supply Current
♦ Preset Thresholds from +1.6V to +5.5V in 100mV
Increments
♦ Internal 5% Threshold Hysteresis
♦ ±2.5% Threshold Accuracy Over Temperature
♦ Internal Timeout Period Option (150ms min)
♦ Immune to Short Voltage Transients
♦ No External Components
♦ Available in Three Output Options: Push-Pull
(Active Low/Active High) and Open Drain (Active
Low)
♦ Fully Specified from -40°C to +125°C
♦ Small SC70 and SOT23 Packages
Ordering Information
PART
TEMP RANGE
PIN-PACKAGE
MAX6461XR_ _-T
-40°C to +125°C
3 SC70-3
MAX6461UR_ _-T
-40°C to +125°C
3 SOT23-3
MAX6461UK_ _-T
-40°C to +125°C
5 SOT23-5
MAX6462XR_ _-T
-40°C to +125°C
3 SC70-3
MAX6462UR_ _-T
-40°C to +125°C
3 SOT23-3
MAX6462UK_ _-T
-40°C to +125°C
5 SOT23-5
The MAX6461–MAX6466 are available in factory-set thresholds
from 1.6V to 5.5V in approximately 100mV increments. Choose
the desired voltage threshold suffix from Table 1 and insert it in
the blank spaces in the part number. There are 30 standard versions with a required order increment of 2500 pieces. Sample
stock generally is held on the standard versions only (Table 2).
Nonstandard versions require a 10k-piece order increment.
Contact factory for availability. All devices available in tape-andreel only.
Load Switching/Power Sequencing
Power-Supply Monitoring in Digital/Analog
Systems
Noise-Immune µP Reset Circuits
Portable/Battery-Powered Equipment
Cellular Phones/Cordless Phones
Devices are available in both leaded and lead-free packaging.
Specify lead-free by replacing “-T” with “+T” when ordering.
PDAs
Portable Medical Devices
Ordering Information continued at end of data sheet.
Selector Guide appears at end of data sheet.
Pin Configurations
TOP VIEW
GND 1
N.C.
MAX6461–
MAX6466
3
1
VCC
GND 2
5
VCC
(OUT)/OUT 1
MAX6461–
MAX6466
MAX6461–
MAX6466
(OUT)/OUT 2
3
VCC
GND 2
SC70-3
( ) ARE FOR THE MAX6462/MAX6465 ONLY
GND 3
4
(OUT)/OUT
SOT23-3
SOT23-5
________________________________________________________________ Maxim Integrated Products
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
1
MAX6461–MAX6466
General Description
MAX6461–MAX6466
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
ABSOLUTE MAXIMUM RATINGS
(All voltages referenced to GND unless otherwise noted.)
VCC, Open-Drain OUT..............................................-0.3V to +7V
Push-Pull OUT/OUT....................................-0.3V to (VCC + 0.3V)
Input/Output Current (all pins) ............................................20mA
Output Short Circuit (VCC or GND)
Continuous Power Dissipation (TA = +70°C)
3-Pin SC70 (derate 2.9mW/°C above +70°C) ...........228.6mW
3-Pin SOT23 (derate 4.0mW/°C above +70°C)............320mW
5-Pin SOT23 (derate 7.1mW/°C above +70°C)............571mW
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = +1.2V to +6V, TA = -40°C to +125°C. Typical values are at TA = +25°C, unless otherwise noted.) (Note1)
PARAMETER
Operating Voltage Range
VCC Supply Current
SYMBOL
VCC
ICC
CONDITIONS
TA = 0°C to +125°C
TA = -40°C to 0°C
MIN
TYP
1
6
1.2
6.0
VCC = 3.6V, TA = -40°C to +125°C,
no load, output not asserted
1
2
VCC = 5.0V, TA = -40°C to +85°C,
no load, output not asserted
1.3
2.5
VCC = 5.0V, TA = +85°C to +125°C,
no load, output not asserted
(VTH+)
× 0.985
VCC rising, TA = -40°C to +125°C
(VTH+)
× 0.975
VCC falling, TA = +25°C
(VTH-)
× 0.985
VCC falling, TA = -40°C to +125°C
(VTH-)
× 0.975
VTH-
Voltage Threshold Hysteresis
VHYST
VHYST = [(VTH+) - (VTH-)] / (VTH-)] × 100%
3
VCC falling at 10mV/µs from
(VTH-) + 100mV to (V TH-) - 100mV
Propagation Delay
tP
VCC rising at 10mV/µs
from (VTH+) - 100mV to
(VTH+) + 100mV
2
VTH+
µA
(VTH+)
× 1.015
(VTH+)
× 1.025
VTH-
V
(VTH-)
× 1.015
(VTH-)
× 1.025
4.5
6
%
µs
MAX6461/
MAX6462/
MAX6463 only
100
225
tRP
V
17
Startup Time
(MAX6461/MAX6462/MAX6463)
Output Timeout Period
(MAX6464/MAX6465/MAX6466)
UNITS
3.5
VCC rising, TA = +25°C
VTH+
Voltage Threshold
(Note 2)
MAX
150
260
_______________________________________________________________________________________
µs
430
ms
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
(VCC = +1.2V to +6V, TA = -40°C to +125°C. Typical values are at TA = +25°C, unless otherwise noted.) (Note1)
PARAMETER
OUT Output Low (Open Drain or
Push-Pull)
OUT Output High (Push-Pull)
OUT Output Open-Drain Leakage
Current
OUT Output High (Push-Pull)
SYMBOL
CONDITIONS
VOL
MIN
0.3
VCC ≥ 2.5V, ISINK = 4.0mA, OUT asserted
0.3
VOH
0.8 ×
VCC
VCC ≥ 2.5V, ISOURCE = 3.0mA,
OUT not asserted
0.8 ×
VCC
VCC ≥ 4.5V, ISOURCE = 8.0mA,
OUT not asserted
0.8 ×
VCC
VOL
V
V
100
VCC ≥ 1.2V, ISOURCE = 200µA,
OUT asserted
0.8 ×
VCC
VCC ≥ 1.8V, ISOURCE = 1.5mA,
OUT asserted
0.8 ×
VCC
VCC ≥ 2.5V, ISOURCE = 3.0mA,
OUT asserted
0.8 ×
VCC
VCC ≥ 4.5V, ISOURCE = 8.0mA,
OUT asserted
0.8 ×
VCC
VCC ≥ 2.5V, ISINK = 4.0mA,
OUT not asserted
OUT Output Low (Push-Pull)
UNITS
0.4
VCC ≥ 1.8V, ISOURCE = 1.5mA,
OUT not asserted
OUT not asserted, V OUT = +6V
ILKG
MAX
VCC ≥ 1.2V, ISINK = 1.0mA, OUT asserted
VCC ≥ 4.5V, ISINK = 9.0mA, OUT asserted
VOH
TYP
nA
V
0.3
V
VCC ≥ 4.5V, ISINK = 9.0mA,
OUT not asserted
0.4
Note 1: 100% production testing done at +25°C. Limits over temperature are guaranteed by design.
Note 2: See Table 1 for VTH- and VTH+ values.
Typical Operating Characteristics
(VCC = 5V, TA = +25°C, unless otherwise noted.)
1.35
1.30
1.25
100
90
80
70
1.20
35
VCC FALLING AT 200mV/µs FROM
((VTH-) + 100mV) TO ((VTH-) - 100mV)
30
25
20
15
10
5
0
60
1.15
40
MAX6461 toc03
VCC RISING AT 200mV/µs FROM
((VTH+) - 100mV) TO ((VTH+) + 100mV)
PROPAGATION DELAY (µs)
110
PROPAGATION DELAY (µs)
SUPPLY CURRENT (µA)
1.40
120
MAX6461 toc02
VCC = 5V, NO LOAD
MAX6461 toc01
1.45
PROPAGATION DELAY (FALLING)
vs. TEMPERATURE
PROPAGATION DELAY (RISING)
vs. TEMPERATURE
SUPPLY CURRENT vs. TEMPERATURE
-40 -25 -10 5 20 35 50 65 80 95 110 125
-40 -25 -10 5 20 35 50 65 80 95 110 125
-40 -25 -10 5 20 35 50 65 80 95 110 125
TEMPERATURE (°C)
TEMPERATURE (°C)
TEMPERATURE (°C)
_______________________________________________________________________________________
3
MAX6461–MAX6466
ELECTRICAL CHARACTERISTICS (continued)
Typical Operating Characteristics (continued)
(VCC = 5V, TA = +25°C, unless otherwise noted.)
MAXIMUM VCC TRANSIENT DURATION
vs. VTH- THRESHOLD OVERDRIVE
PROPAGATION DELAY VCC FALLING
MAX6461 toc05b
MAX6461 toc04
19
TRANSIENT DURATION (µs)
PROPAGATION DELAY VCC RISING
MAX6461 toc05a
20
18
17
100mV/div
AC-COUPLED
OUTPUT ASSERTS
ABOVE THIS LINE
16
VCC
100mV/div
AC-COUPLED
OUT
1V/div
VCC
15
14
1V/div
13
ACTIVE-HIGH
OUTPUT
ACTIVE-HIGH
OUTPUT
OUT
12
MAX6464_ _22
11
MAX6462_ _16
MAX6462_ _16
10
1
OUTPUT VOLTAGE HIGH
vs. SOURCE CURRENT
OUTPUT VOLTAGE HIGH
vs. SOURCE CURRENT
VCC = 3.3V
VTH = 2.9V
3.3
4.5
3.1
2.9
2.5
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
SOURCE CURRENT (mA)
NORMALIZED THRESHOLD
vs. TEMPERATURE
NORMALIZED OUTPUT TIMEOUT PERIOD
vs. TEMPERATURE
1.01
1.00
0.99
0.98
1.02
0
MAX6466
1
2
3
4
5
6
7
8
9
10
SINK CURRENT (mA)
HYSTERESIS vs. TEMPERATURE
6.0
MAX6461
1.01
5.5
% OF VTH-
MAX6461 toc08
1.02
200
175
150
125
100
10
SOURCE CURRENT (mA)
MAX6461 toc09
1
NORMALIZED RESET TIMEOUT PERIOD
0
225
75
50
25
0
2.7
4.0
VCC = 2.7V
VTH = 2.9V
250
OUTPUT VOLTAGE (mV)
5.0
300
275
MAX6461 toc06b
MAX6461 toc06a
5.5
OUTPUT VOLTAGE LOW
vs. SINK CURRENT
3.5
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
6.0
4
10µs/div
20µs/div
MAX6461 toc07
0.1
VTH- THRESHOLD OVERDRIVE ((VTH-) - VCC) (V)
MAX6461 toc10
0.01
NORMALIZED THRESHOLD
MAX6461–MAX6466
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
1.00
0.99
5.0
4.5
0.98
4.0
-40 -25 -10 5 20 35 50 65 80 95 110 125
-40 -25 -10 5 20 35 50 65 80 95 110 125
-40 -25 -10 5 20 35 50 65 80 95 110 125
TEMPERATURE (°C)
TEMPERATURE (°C)
TEMPERATURE (°C)
_______________________________________________________________________________________
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
PIN
NAME
MAX6461–MAX6466
SOT23-3
1
SC70-3
FUNCTION
SOT23-5
2
OUT
Detector Output for the MAX6461/MAX6462/MAX6463: Push-pull (active-low or
active-high) and open-drain (active-low) options. OUT is asserted low when the
monitored input (VCC) drops below the internal VTH- threshold and remains low
until the monitored input exceeds the internal VTH+ threshold. OUT is asserted
high when the monitored input (VCC) drops below the internal VTH- threshold and
remains high until the monitored input exceeds the internal VTH+ threshold. The
open-drain output OUT requires an external pullup resistor. Output for the
MAX6464/MAX6465/MAX6466: Push-pull (active-low or active-high) and opendrain (active-low) options.
OUT
OUT is asserted low when the monitored input (VCC) drops below the internal
VTH- threshold and remains low for at least 150ms after the monitored input
exceeds the internal VTH+ threshold. OUT is asserted high when the monitored
input (VCC) drops below the internal VTH- threshold and remains high for at least
150ms after the monitored input exceeds the internal VTH+ threshold. The opendrain output OUT requires an external pullup resistor.
4
2
1
2, 3
GND
Ground. In the SOT23-5 package, both pins must be grounded.
3
3
5
VCC
Supply Voltage and Monitored Voltage Input
—
—
1
N.C.
No Connection
Functional Diagram
VCC
MAX6461–
MAX6466
R1
R2
RESET
TIMEOUT
OUTPUT
STAGE
OUT
Detailed Description
The MAX6461/MAX6462/MAX6463 voltage detectors
and the MAX6464/MAX6465/MAX6466 µP reset supervisory circuits monitor battery, power-supply, and system
voltages from +1.6V to +5.5V. These devices consume
only 1µA of supply current with a 3.6V supply voltage.
Whenever VCC falls below the internal VTH- threshold,
the output is asserted and remains asserted until VCC
rises above VTH+ (VTH+ = VTH- × 1.05). All devices have
±2.5% threshold accuracy over temperature and offer
protection to short voltage transients. These devices are
ideal for low-cost and space-critical applications
because they do not require external components for
proper operation.
R3
1.23V
_______________________________________________________________________________________
5
MAX6461–MAX6466
Pin Description
MAX6461–MAX6466
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
Hysteresis
IN
DC/DC
CONVERTER
OUT
VCC
3.6V
Li+
VCC
µP
MAX6463
MAX6466
OUT
SUSPEND
Figure 1. Interfacing to Different Logic Voltage Components
Applications Information
Interfacing to Different Logic Voltage
Components
The MAX6463 and MAX6466’s active-low, open-drain output versions can be used to interface with a different logic
voltage than VCC, as shown in Figure 1. This output structure sinks current when OUT is asserted. Connect a
pullup resistor from OUT to any supply from 0 to 6V.
Select a resistor value large enough to allow a valid logic
low (see the Electrical Characteristics) and small enough
to register a logic high while supplying all input current
and leakage paths connected to the OUT pin.
6
The MAX6461–MAX6466 feature internal hysteresis that
creates two trip points: one for rising supply voltage
and one for falling supply voltage. The hysteresis prevents the output from oscillating (chattering) when VCC
is near the voltage threshold.
Transients Immunity
These devices are relatively immune to short-duration
and falling V CC transients (glitches). The Typical
Operating Characteristics show the Maximum Transient
Duration vs. Threshold Overdrive graph, for which OUT
is not asserted. The graph shows the maximum pulse
width that a falling VCC transient typically might have
before the devices are asserted. As the amplitude of
the transient increases, the maximum allowable pulse
width decreases.
Ensuring Valid Output Down to 0V
When VCC falls below 1V, the MAX6461/MAX6464 output sinking capability is reduced. Therefore, highimpedance CMOS logic inputs connected to OUT can
drift to undetermined voltages. This presents no problem in most applications, because most circuitry is
inoperative when V CC is below 1V. In applications
where OUT must be valid down to ground, add a pulldown resistor to ground so any stray leakage currents
flow to ground, holding OUT low. Select a resistor large
enough not to load OUT and small enough to pull OUT
to ground. For most applications, 100kΩ does not load
OUT and pulls OUT to ground.
_______________________________________________________________________________________
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
MAX6461–MAX6466
Table 1a. MAX6461–MAX6466 Lower Trip Threshold (VTH-) Voltage Options
VOLTAGE THRESHOLD, VTHSUFFIX
TA = +25°C
TA = -40°C to +125°C
VTH- (min)
VTH- (typ)
VTH- (max)
VTH- (min)
VTH- (max)
16
17
1.576
1.675
1.600
1.700
1.624
1.726
1.560
1.658
1.640
1.743
18
1.773
1.800
1.827
1.755
1.845
19
1.872
1.900
1.929
1.853
1.948
20
21
1.970
2.069
2.000
2.100
2.030
2.132
1.950
2.048
2.050
2.153
22
2.167
2.200
2.233
2.145
2.255
23
2.266
2.300
2.335
2.243
2.358
24
25
2.364
2.463
2.400
2.500
2.436
2.538
2.340
2.438
2.460
2.563
26
2.561
2.600
2.639
2.535
2.665
27
2.660
2.700
2.741
2.633
2.768
28
29
2.758
2.857
2.800
2.900
2.842
2.944
2.730
2.828
2.870
2.973
30
2.955
3.000
3.045
2.925
3.075
31
3.054
3.100
3.147
3.023
3.178
32
33
3.152
3.251
3.200
3.300
3.248
3.350
3.120
3.218
3.280
3.383
34
3.349
3.400
3.451
3.315
3.485
35
3.448
3.500
3.553
3.413
3.588
36
37
3.546
3.645
3.600
3.700
3.654
3.756
3.510
3.608
3.690
3.793
38
3.743
3.800
3.857
3.705
3.895
39
3.842
3.900
3.959
3.803
3.998
40
41
3.940
4.039
4.000
4.100
4.060
4.162
3.900
3.998
4.100
4.203
42
4.137
4.200
4.263
4.095
4.305
43
4.236
4.300
4.365
4.193
4.408
44
45
4.334
4.433
4.400
4.500
4.466
4.568
4.290
4.388
4.510
4.613
46
4.531
4.600
4.669
4.485
4.715
47
4.630
4.700
4.771
4.583
4.818
48
49
4.728
4.827
4.800
4.900
4.872
4.974
4.680
4.778
4.920
5.023
50
4.925
5.000
5.075
4.875
5.125
51
5.024
5.100
5.177
4.973
5.228
52
53
5.122
5.221
5.200
5.300
5.278
5.380
5.070
5.168
5.330
5.433
54
5.319
5.400
5.481
5.265
5.535
55
5.418
5.500
5.583
5.363
5.638
_______________________________________________________________________________________
7
MAX6461–MAX6466
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
Table 1b. MAX6461–MAX6466 Upper Trip Threshold (VTH+) Voltage Options
VOLTAGE THRESHOLD, VTH+
SUFFIX
8
VTH+ (min)
TA = +25°C
VTH+ (typ)
VTH+ (max)
TA = -40°C to +125°C
VTH+ (min)
VTH+ (max)
16
1.647
1.672
1.697
1.630
1.714
17
1.750
1.777
1.803
1.732
1.821
18
19
1.853
1.956
1.881
1.986
1.909
2.015
1.834
1.936
1.928
2.035
20
2.059
2.090
2.121
2.038
2.142
21
2.162
2.195
2.227
2.140
2.249
22
23
2.265
2.367
2.299
2.404
2.333
2.440
2.242
2.343
2.356
2.464
24
2.470
2.508
2.546
2.445
2.571
25
2.573
2.613
2.652
2.547
2.678
26
27
2.676
2.779
2.717
2.822
2.758
2.864
2.649
2.751
2.785
2.892
28
2.882
2.926
2.970
2.853
2.999
29
2.985
3.031
3.076
2.955
3.106
30
31
3.088
3.191
3.135
3.240
3.182
3.288
3.057
3.159
3.213
3.320
32
3.294
3.344
3.394
3.260
3.428
33
3.397
3.449
3.500
3.362
3.535
34
35
3.500
3.603
3.553
3.658
3.606
3.712
3.464
3.566
3.642
3.749
36
3.706
3.762
3.818
3.668
3.856
37
3.809
3.867
3.924
3.770
3.963
38
39
3.911
4.014
3.971
4.076
4.031
4.137
3.872
3.974
4.070
4.177
40
4.117
4.180
4.243
4.076
4.285
41
4.220
4.285
4.349
4.177
4.392
42
43
4.323
4.426
4.389
4.494
4.455
4.561
4.279
4.381
4.499
4.606
44
4.529
4.598
4.667
4.483
4.713
45
4.632
4.703
4.773
4.585
4.820
46
47
4.735
4.838
4.807
4.912
4.879
4.985
4.687
4.789
4.927
5.034
48
4.941
5.016
5.091
4.891
5.141
49
5.044
5.121
5.197
4.992
5.249
50
51
5.147
5.250
5.225
5.330
5.303
5.409
5.094
5.196
5.356
5.463
52
5.352
5.434
5.516
5.298
5.570
53
5.455
5.539
5.622
5.400
5.677
54
55
5.558
5.661
5.643
5.748
5.728
5.834
5.502
5.604
5.784
5.891
_______________________________________________________________________________________
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
MAX6461–MAX6466
Table 2. Standard Versions Table
TOP MARK
(SC70)
PART
TOP MARK
(SC70)
PART
AMB
MAX6464XR16-T
AMO
MAX6461XR22-T
AMC
MAX6464XR22-T
AMP
MAX6461XR26-T
AMD
MAX6464XR26-T
AMQ
MAX6461XR29-T
AKV
MAX6464XR29-T
AMR
MAX6461XR46-T
AME
MAX6464XR46-T
AMS
MAX6462XR16-T
AKW
MAX6465XR16-T
AMT
MAX6462XR22-T
AMF
MAX6465XR22-T
AMU
MAX6462XR26-T
AMG
MAX6465XR26-T
AMV
MAX6462XR29-T
AMH
MAX6465XR29-T
AMW
MAX6462XR46-T
AMI
MAX6465XR46-T
AKZ
MAX6463XR16-T
AMJ
MAX6466XR16-T
AMX
MAX6463XR22-T
AMK
MAX6466XR22-T
AMY
MAX6463XR26-T
AML
MAX6466XR26-T
AMZ
MAX6463XR29-T
AMM
MAX6466XR29-T
ALA
MAX6463XR46-T
AMN
MAX6466XR46-T
ALB
MAX6461XR16-T
Selector Guide
PUSH-PULL
OUT
PUSH-PULL
OUT
OPEN-DRAIN
OUT
TYPICAL
PROPAGATION
DELAY (µs)
MINIMUM TIMEOUT
PERIOD (ms)
MAX6461
✔
—
—
14
—
MAX6462
—
✔
—
14
—
MAX6463
—
—
✔
14
—
MAX6464
✔
—
—
—
150
MAX6465
—
✔
—
—
150
MAX6466
—
—
✔
—
150
PART
_______________________________________________________________________________________
9
MAX6461–MAX6466
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
Ordering Information (continued)
PART
TEMP RANGE
PIN-PACKAGE
MAX6463XR_ _-T
-40°C to +125°C
3 SC70-3
MAX6463UR_ _-T
-40°C to +125°C
3 SOT23-3
MAX6463UK_ _-T
-40°C to +125°C
5 SOT23-5
MAX6464XR_ _-T
-40°C to +125°C
3 SC70-3
MAX6464UR_ _-T
-40°C to +125°C
3 SOT23-3
MAX6464UK_ _-T
-40°C to +125°C
5 SOT23-5
MAX6465XR_ _-T
-40°C to +125°C
3 SC70-3
MAX6465UR_ _-T
-40°C to +125°C
3 SOT23-3
MAX6465UK_ _-T
-40°C to +125°C
5 SOT23-5
MAX6466XR_ _-T
-40°C to +125°C
3 SC70-3
MAX6466UR_ _-T
-40°C to +125°C
3 SOT23-3
MAX6466UK_ _-T
-40°C to +125°C
5 SOT23-5
Chip Information
TRANSISTOR COUNT: 581
PROCESS: BiCMOS
Package Information
For the latest package outline information, go to
www.maxim-ic.com/packages.)
The MAX6461–MAX6466 are available in factory-set thresholds
from 1.6V to 5.5V in approximately 100mV increments. Choose
the desired voltage threshold suffix from Table 1 and insert it in
the blank spaces in the part number. There are 30 standard versions with a required order increment of 2500 pieces. Sample
stock generally is held on the standard versions only (Table 2).
Nonstandard versions require a 10k-piece order increment.
Contact factory for availability. All devices available in tape-andreel only.
Devices are available in both leaded and lead-free packaging.
Specify lead-free by replacing “-T” with “+T” when ordering.
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
10 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2005 Maxim Integrated Products
Printed USA
is a registered trademark of Maxim Integrated Products, Inc.
Similar pages