19-0567; Rev 0; 5/06 7-Channel Precision Temperature Monitor The MAX6689 precision multichannel temperature sensor monitors its own temperature and the temperatures of up to six external diode-connected transistors. All temperature channels have programmable alert thresholds. Channels 1, 4, 5, and 6 also have programmable overtemperature thresholds. When the measured temperature of a channel exceeds the respective threshold, a status bit is set in one of the status registers. Two open-drain outputs, OVERT and ALERT, assert corresponding to these bits in the status register. The 2-wire serial interface supports the standard system management bus (SMBus™) protocols: write byte, read byte, send byte, and receive byte for reading the temperature data and programming the alarm thresholds. The MAX6689 is specified for an operating temperature range of -40°C to +125°C and is available in 20-pin QSOP and TSSOP packages. Applications Desktop Computers Notebook Computers Workstations Servers Features ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Six Thermal-Diode Inputs Local Temperature Sensor 1°C Remote Temperature Accuracy (+60°C to +100°C) Temperature Monitoring Begins at POR for FailSafe System Protection ALERT and OVERT Outputs for Interrupts, Throttling, and Shutdown STBY Input for Hardware Standby Mode Small, 20-Pin QSOP and TSSOP Packages 2-Wire SMBus Interface Ordering Information PART MAX6689EP34+ MAX6689EP38+ MAX6689EP9A+ MAX6689EP9E+ MAX6689UP34+ MAX6689UP38+ MAX6689UP9A+ MAX6689UP9E+ PINPACKAGE 20 QSOP 20 QSOP 20 QSOP 20 QSOP 20 TSSOP 20 TSSOP 20 TSSOP 20 TSSOP SLAVE ADDRESS 0011 010 0011 100 1001 101 1001 111 0011 010 0011 100 1001 101 1001 111 PKG CODE E20-1 E20-1 E20-1 E20-1 U20-2 U20-2 U20-2 U20-2 SMBus is a trademark of Intel Corp. Note: All devices are specified over the -40°C to +125°C temperature range. Pin Configuration appears at end of data sheet. +Denotes lead-free package. Typical Application Circuit +3.3V CPU GND 20 4.7kΩ EACH SMBCLK 19 CLK DXP2 SMBDATA 18 DATA 4 DXN2 ALERT 17 5 DXP3 VCC 16 6 DXN3 OVERT 15 7 DXP4 N.C. 14 8 DXN4 STBY 13 9 DXP5 DXP6 12 10 DXN5 DXN6 11 1 DXP1 2 DXN1 3 2200pF MAX6689 2200pF INTERRUPT TO µP 0.1µF 2200pF TO SYSTEM SHUTDOWN 2200pF GPU 2200pF 2200pF ________________________________________________________________ Maxim Integrated Products For pricing delivery, and ordering information please contact Maxim/Dallas Direct! at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. 1 MAX6689 General Description MAX6689 7-Channel Precision Temperature Monitor ABSOLUTE MAXIMUM RATINGS VCC, SCK, SDA, ALERT, OVERT, STBY to GND .....-0.3V to +6V DXP_ to GND..............................................-0.3V to (VCC + 0.3V) DXN_ to GND ........................................................-0.3V to +0.8V SDA, ALERT, OVERT Current .............................-1mA to +50mA DXN Current .......................................................................±1mA Continuous Power Dissipation (TA = +70°C) 20-Pin QSOP (derate 9.1mW/°C above +70°C) ..................................727.3mW 20-Pin TSSOP (derate 11.0mW/°C above +70°C)..............................879.1mW ESD Protection (all pins, Human Body Model) ................±2000V Operating Temperature Range .........................-40°C to +125°C Junction Temperature ......................................................+150°C Storage Temperature Range .............................-60°C to +150°C Lead Temperature (soldering, 10s) .................................+300°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. ELECTRICAL CHARACTERISTICS (VCC = +3.0V to +5.5V, VSTBY = VCC, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VCC = +3.3V and TA = +25°C.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP Supply Voltage VCC Software Standby Supply Current ISS SMBus static 30 Operating Current ICC During conversion 500 Channel 1 only 11 Other diode channels 8 Temperature Resolution Remote Temperature Accuracy 3.0 VCC = 3.3V Local Temperature Accuracy VCC = 3.3V 1000 tCONV1 Remote Channels 2 Through 6 Conversion Time tCONV_ Remote-Diode Source Current IRJ UVLO -1.0 +1.0 -3.0 +3.0 -3.3 +0.7 TA = 0°C to +125°C -5.0 +1.0 95 125 156 Resistance cancellation on 190 250 312 95 125 156 High level 80 100 120 Low level 8 10 12 2.30 2.80 2.95 90 VCC falling edge POR Threshold Hysteresis C 1.2 2.0 o o Resistance cancellation off Undervoltage-Lockout Hysteresis Power-On Reset (POR) Threshold o ±2.5 TA = +60°C to +100°C Falling edge of VCC disables ADC µA Bits TA = TRJ = 0°C to +125°C DXN_ grounded, TRJ = TA = 0°C to +85°C V µA ±0.2 Remote Channel 1 Conversion Time UNITS 5.5 TA = TRJ = +60°C to +100°C Supply Sensitivity of Temperature Accuracy Undervoltage-Lockout Threshold MAX C C/V ms ms µA V mV 2.5 90 V mV ALERT, OVERT Output Low Voltage VOL ISINK = 1mA 0.3 ISINK = 6mA 0.5 Output Leakage Current 2 _______________________________________________________________________________________ 1 V µA 7-Channel Precision Temperature Monitor (VCC = +3.0V to +5.5V, VSTBY = VCC, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VCC = +3.3V and TA = +25°C.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS 0.8 V SMBus INTERFACE (SCL, SDA), STBY Logic-Input Low Voltage VIL Logic-Input High Voltage VIH VCC = 3.0V 2.2 VCC = 5.0V 2.4 Input Leakage Current V -1 Output Low Voltage VOL Input Capacitance CIN +1 ISINK = 6mA 0.3 5 µA V pF SMBus-COMPATIBLE TIMING (Figures 3 and 4) (Note 2) Serial-Clock Frequency Bus Free Time Between STOP and START Condition fSCL tBUF START Condition Setup Time Repeat START Condition Setup Time START Condition Hold Time STOP Condition Setup Time tSU:STA tHD:STA tSU:STO Clock-Low Period tLOW Clock-High Period tHIGH Data Hold Time tHD:DAT Data Setup Time tSU:DAT Receive SCL/SDA Rise Time tR Receive SCL/SDA Fall Time tF Pulse Width of Spike Suppressed tSP SMBus Timeout Note 1: Note 2: Note 3: Note 4: tTIMEOUT (Note 3) 400 fSCL = 100kHz 4.7 fSCL = 400kHz 1.6 fSCL = 100kHz 4.7 fSCL = 400kHz 0.6 90% of SCL to 90% of SDA, fSCL = 100kHz 0.6 90% of SCL to 90% of SDA, fSCL = 400kHz 0.6 10% of SDA to 90% of SCL 0.6 90% of SCL to 90% of SDA, fSCL = 100kHz 4 90% of SCL to 90% of SDA, fSCL = 400kHz 0.6 10% to 10%, fSCL = 100kHz 1.3 10% to 10%, fSCL = 400kHz 1.3 90% to 90% 0.6 fSCL = 100kHz 300 µs µs µs µs µs µs µs fSCL = 400kHz (Note 4) 900 fSCL = 100kHz 250 fSCL = 400kHz 100 1 fSCL = 400kHz 0.3 300 0 25 ns ns fSCL = 100kHz SDA low period for interface reset kHz 37 µs ns 50 ns 45 ms All parameters are tested at TA = +85°C. Specifications over temperature are guaranteed by design. Timing specifications are guaranteed by design. The serial interface resets when SCL is low for more than tTIMEOUT. A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SCL’s falling edge. _______________________________________________________________________________________ 3 MAX6689 ELECTRICAL CHARACTERISTICS (continued) Typical Operating Characteristics (VCC = 3.3V, VSTBY = VCC, TA = +25°C, unless otherwise noted.) SUPPLY CURRENT (µA) 8 7 6 5 4 2 350 345 340 335 330 3 2 1 0 4.8 3.3 5.3 3.8 4.3 4.8 5.3 2 1 0 -1 -2 5 75 3 2 1 0 -1 -2 -3 -3 -4 -4 -5 25 50 75 100 0.1 125 1 FREQUENCY (MHz) DIE TEMPERATURE (°C) LOCAL TEMPERATURE ERROR vs. POWER-SUPPLY NOISE FREQUENCY REMOTE TEMPERATURE ERROR vs. COMMON-MODE NOISE FREQUENCY 5 MAX6689 toc06 100mVP-P TEMPERATURE ERROR (°C) 3 4 2 1 0 -1 -2 -3 MAX6689 toc07 0 TEMPERATURE ERROR (°C) 50 100mVP-P 4 TEMPERATURE ERROR (°C) MAX6689 toc04 3 100mVP-P 3 2 1 0 -1 -2 -3 -4 -4 -5 0.001 -5 0.001 0.01 0.1 FREQUENCY (MHz) 4 25 REMOTE-DIODE TEMPERATURE ERROR vs. POWER-SUPPLY NOISE FREQUENCY 4 TEMPERATURE ERROR (°C) 0 1 100 REMOTE-DIODE TEMPERATURE (°C) LOCAL TEMPERATURE ERROR vs. DIE TEMPERATURE 4 -2 SUPPLY VOLTAGE (V) SUPPLY VOLTAGE (V) 5 -1 MAX6689 toc05 4.3 0 -4 320 3.8 1 -3 325 3.3 MAX6689 toc03 355 9 3 TEMPERATURE ERROR (°C) 11 10 MAX6689 toc02 360 MAX6689 toc01 12 REMOTE TEMPERATURE ERROR vs. REMOTE-DIODE TEMPERATURE SUPPLY CURRENT vs. SUPPLY VOLTAGE SOFTWARE STANDBY SUPPLY CURRENT vs. SUPPLY VOLTAGE STANDBY SUPPLY CURRENT (µA) MAX6689 7-Channel Precision Temperature Monitor 0.01 0.1 1 FREQUENCY (MHz) _______________________________________________________________________________________ 10 125 7-Channel Precision Temperature Monitor REMOTE TEMPERATURE ERROR vs. COMMON-MODE NOISE FREQUENCY 0 3 2 1 0 -1 -2 -0.5 -1.0 -1.5 -2.0 -2.5 -3.0 -3.5 -3 -4.0 -4 -4.5 -5 0.001 MAX6689 toc09 100mVP-P TEMPERATURE ERROR (°C) TEMPERATURE ERROR (°C) 4 MAX6689 toc08 5 TEMPERATURE ERROR vs. DXP-DXN CAPACITANCE -5.0 0.01 0.1 1 10 1 FREQUENCY (MHz) 100 10 DXP-DXN CAPACITANCE (nF) Pin Description PIN NAME FUNCTION 1 DXP1 Combined Current Source and A/D Positive Input for Channel 1 Remote Diode. Connect to the anode of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to DXN1 if no remote diode is used. Place a 2200pF capacitor between DXP1 and DXN1 for noise filtering. 2 DXN1 Cathode Input for Channel 1 Remote Diode. Connect the cathode of the channel 1 remote-diodeconnected transistor to DXN1. 3 DXP2 Combined Current Source and A/D Positive Input for Channel 2 Remote Diode. Connect to the anode of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to DXN2 if no remote diode is used. Place a 2200pF capacitor between DXP2 and DXN2 for noise filtering. 4 DXN2 Cathode Input for Channel 2 Remote Diode. Connect the cathode of the channel 2 remote-diodeconnected transistor to DXN2. 5 DXP3 Combined Current Source and A/D Positive Input for Channel 3 Remote Diode. Connect to the anode of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to DXN3 if no remote diode is used. Place a 2200pF capacitor between DXP3 and DXN3 for noise filtering. 6 DXN3 Cathode Input for Channel 3 Remote Diode. Connect the cathode of the channel 1 remote-diodeconnected transistor to DXN3. 7 DXP4 Combined Current Source and A/D Positive Input for Channel 4 Remote Diode. Connect to the anode of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to DXN4 if no remote diode is used. Place a 2200pF capacitor between DXP4 and DXN4 for noise filtering. 8 DXN4 Cathode Input for Channel 4 Remote Diode. Connect the cathode of the channel 1 remote-diodeconnected transistor to DXN4. _______________________________________________________________________________________ 5 MAX6689 Typical Operating Characteristics (continued) (VCC = 3.3V, VSTBY = VCC, TA = +25°C, unless otherwise noted.) 7-Channel Precision Temperature Monitor MAX6689 Pin Description (continued) PIN NAME FUNCTION 9 DXP5 Combined Current Source and A/D Positive Input for Channel 5 Remote Diode. Connect to the anode of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to DXN5 if no remote diode is used. Place a 2200pF capacitor between DXP5 and DXN5 for noise filtering. 10 DXN5 Cathode Input for Channel 5 Remote Diode. Connect the cathode of the channel 1 remote-diodeconnected transistor to DXN5. 11 DXN6 Cathode Input for Channel 6 Remote Diode. Connect the cathode of the channel 1 remote-diodeconnected transistor to DXN6. 12 DXP6 Combined Current Source and A/D Positive Input for Channel 6 Remote Diode. Connect to the anode of a remote-diode-connected temperature-sensing transistor. Leave floating or connect to DXN6 if no remote diode is used. Place a 2200pF capacitor between DXP6 and DXN6 for noise filtering. 13 STBY Active-Low Standby Input. Drive STBY logic-low to place the MAX6689 in standby mode, or logic-high for operate mode. Temperature and threshold data are retained in standby mode. 14 N.C. No Connection. Must be connected to ground. 15 OVERT 16 VCC 17 ALERT 18 SMBDATA 19 SMBCLK 20 GND Overtemperature Active-Low, Open-Drain Output. OVERT asserts low when the temperature of channels 1, 4, 5, and 6 exceeds the programmed threshold limit. Supply Voltage Input. Bypass to GND with a 0.1µF capacitor. SMBus Alert (Interrupt), Active-Low, Open-Drain Output. ALERT asserts low when the temperature of any channel exceeds the programmed ALERT threshold. SMBus Serial-Data Input/Output. Connect to a pullup resistor. SMBus Serial-Clock Input. Connect to a pullup resistor. Ground Detailed Description The MAX6689 is a precision multichannel temperature monitor that features one local and six remote temperature-sensing channels with a programmable alert threshold for each temperature channel and a programmable overtemperature threshold for channels 1, 4, 5, and 6 (see Figure 1). Communication with the MAX6689 is achieved through the SMBus serial interface and a dedicated alert pin. The alarm outputs, OVERT and ALERT, assert if the software-programmed temperature thresholds are exceeded. ALERT typically serves as an interrupt, while OVERT can be connected to a fan, system shutdown, or other thermal-management circuitry. ADC Conversion Sequence In the default conversion mode, the MAX6689 starts the conversion sequence by measuring the temperature on channel 1, followed by 2, 3, local channel, 4, 5, and 6. The conversion result for each active channel is stored in the corresponding temperature data register. In some systems, one of the remote thermal diodes may be monitoring a location that experiences temperature changes that occur much more rapidly than in the other channels. If faster temperature changes must be monitored in one of the temperature channels, the MAX6689 6 allows channel 1 to be monitored at a faster rate than the other channels. In this mode (set by writing a 1 to bit 4 of the configuration 1 register), measurements of channel 1 alternate with measurements of the other channels. The sequence becomes channel 1, channel 2, channel 1, channel 3, channel 1, etc. Note that the time required to measure all seven channels is considerably greater in this mode than in the default mode. Low-Power Standby Mode Enter software standby mode by setting the STOP bit to 1 in the configuration 1 register. Enter hardware standby by pulling STBY low. Software standby mode disables the ADC and reduces the supply current to approximately 30µA. Hardware standby mode halts the ADC clock, but the supply current is approximately 350µA. During either software or hardware standby, data is retained in memory, and the SMBus interface is active and listening for SMBus commands. The timeout is enabled if a start condition is recognized on SMBus. Activity on the SMBus causes the supply current to increase. If a standby command is received while a conversion is in progress, the conversion cycle is interrupted, and the temperature registers are not updated. The previous data is not changed and remains available. _______________________________________________________________________________________ 7-Channel Precision Temperature Monitor MAX6689 VCC DXP1 MAX6689 ADC DXN1 DXP2 10/100µA ALARM ALU DXN2 OVERT AVERT DXP3 DXN3 COUNT INPUT BUFFER DXP4 REGISTER BANK COMMAND BYTE COUNTER REMOTE TEMPERATURES DXN4 LOCAL TEMPERATURES REF DXP5 ALERT THRESHOLD OVERT THRESHOLD DXN5 ALERT RESPONSE ADDRESS DXP6 SMBus INTERFACE DXN6 STBY SCL SDA Figure 1. Internal Block Diagram SMBus Digital Interface From a software perspective, the MAX6689 appears as a series of 8-bit registers that contain temperature measurement data, alarm threshold values, and control bits. A standard SMBus-compatible, 2-wire serial interface is used to read temperature data and write control bits and alarm threshold data. The same SMBus slave address also provides access to all functions. The MAX6689 employs four standard SMBus protocols: write byte, read byte, send byte, and receive byte (Figure 2). The shorter receive byte protocol allows quicker transfers, provided that the correct data register was previously selected by a read byte instruction. Use caution with the shorter protocols in multimaster systems, since a second master could overwrite the command byte without informing the first master. Figure 3 is the SMBus write-timing diagram and Figure 4 is the SMBus read-timing diagram. The remote diode 1 measurement channel provides 11 bits of data (1 LSB = 0.125°C). All other temperaturemeasurement channels provide 8 bits of temperature data (1 LSB = 1°C). The 8 most significant bits (MSBs) can be read from the local temperature and remote temperature registers. The remaining 3 bits for remote diode 1 can be read from the extended temperature register. If extended resolution is desired, the extended resolution register should be read first. This prevents the most significant bits from being overwritten by new _______________________________________________________________________________________ 7 MAX6689 7-Channel Precision Temperature Monitor WRITE BYTE FORMAT S ADDRESS WR ACK COMMAND 7 BITS ACK DATA 8 BITS ACK P 8 BITS SLAVE ADDRESS: EQUIVALENT TO CHIP-SELECT LINE OF A 3-WIRE INTERFACE 1 DATA BYTE: DATA GOES INTO THE REGISTER SET BY THE COMMAND BYTE (TO SET THRESHOLDS, CONFIGURATION MASKS, AND SAMPLING RATE) READ BYTE FORMAT S ADDRESS WR ACK 7 BITS COMMAND ACK S SLAVE ADDRESS: EQUIVALENT TO CHIP SELECT LINE ADDRESS RD COMMAND BYTE: SELECTS WHICH REGISTER YOU ARE REDING FROM DATA /// P 8 BITS SLAVE ADDRESS: REPEATED DUE TO CHANGE IN DATAFLOW DIRECTION DATA BYTE: READS FROM THE REGISTER SET BY THE COMMAND BYTE RECEIVE BYTE FORMAT WR ACK 7 BITS COMMAND ACK P 8 BITS S ADDRESS RD 7 BITS ACK DATA /// P 8 BITS COMMAND BYTE: SENDS COMMAND WITH NO DATA, USUALLY USED FOR ONE-SHOT COMMAND S = START CONDITION. P = STOP CONDITION. ACK 7 BITS SEND BYTE FORMAT S ADDRESS 8 BITS DATA BYTE: READS DATA FROM THE REGISTER COMMANDED BY THE LAST READ BYTE OR WRITE BYTE TRANSMISSION; ALSO USED FOR SMBUS ALERT RESPONSE RETURN ADDRESS SHADED = SLAVE TRANSMISSION. /// = NOT ACKNOWLEDGED. Figure 2. SMBus Protocols Table 1. Main Temperature Register (High-Byte) Data Format TEMP (°C) DIGITAL OUTPUT TEMP (°C) DIGITAL OUTPUT > +127 0111 1111 0 000X XXXX +127 0111 1111 +0.125 001X XXXX +126 0111 1110 +0.250 010X XXXX +25 0001 1001 +0.375 011X XXXX 0000 0000 +0.500 100X XXXX <0 0000 0000 +0.625 101X XXXX Diode fault (short or open) 1111 1111 +0.725 110X XXXX +0.875 111X XXXX 0 conversion results until they have been read. If the most significant bits have not been read within an SMBus timeout period (nominally 37ms), normal updating continues. Table 1 shows the main temperature register (high-byte) data format, and Table 2 shows the extended resolution register (low-byte) data format. 8 Table 2. Extended Resolution Temperature Register (Low-Byte) Data Format Diode Fault Detection If a channel’s input DXP_ and DXN_ are left open or shorted together, the MAX6689 detects a diode fault. A diode fault, whether a short or an open circuit, does not cause either ALERT or OVERT to assert. A bit in the status register for the corresponding channel is set to 1 and the temperature data for the channel is stored as all 1s. It takes approximately 4ms for the MAX6689 to detect a diode fault. Once a diode fault is detected, the MAX6689 jumps onto the next channel in the conversion sequence. _______________________________________________________________________________________ 7-Channel Precision Temperature Monitor B tLOW C D E F G H tHIGH I J K L MAX6689 A M SMBCLK SMBDATA tSU:STA tHD:STA tSU:STO tSU:DAT A = START CONDITION. B = MSB OF ADDRESS CLOCKED INTO SLAVE. C = LSB OF ADDRESS CLOCKED INTO SLAVE. D = R/W BIT CLOCKED INTO SLAVE. E = SLAVE PULLS SMBDATA LINE LOW. F = ACKNOWLEDGE BIT CLOCKED INTO MASTER. G = MSB OF DATA CLOCKED INTO SLAVE. H = LSB OF DATA CLOCKED INTO SLAVE. tBUF I = MASTER PULLS DATA LINE LOW. J = ACKNOWLEDGE CLOCKED INTO SLAVE. K = ACKNOWLEDGE CLOCK PULSE. L = STOP CONDITION. M = NEW START CONDITION. Figure 3. SMBus Write-Timing Diagram A tLOW B tHIGH C D E F G H I J K L M SMBCLK SMBDATA tSU:STA tHD:STA tSU:DAT A = START CONDITION. B = MSB OF ADDRESS CLOCKED INTO SLAVE. C = LSB OF ADDRESS CLOCKED INTO SLAVE. D = R/W BIT CLOCKED INTO SLAVE. E = SLAVE PULLS SMBDATA LINE LOW. tHD:DAT F = ACKNOWLEDGE BIT CLOCKED INTO MASTER. G = MSB OF DATA CLOCKED INTO MASTER. H = LSB OF DATA CLOCKED INTO MASTER. I = MASTER PULLS DATA LINE LOW. tSU:STO tBUF J = ACKNOWLEDGE CLOCKED INTO SLAVE. K = ACKNOWLEDGE CLOCK PULSE. L = STOP CONDITION. M = NEW START CONDITION. Figure 4. SMBus Read-Timing Diagram Alarm Threshold Registers There are 11 alarm threshold registers that store overtemperature ALERT and OVERT threshold values. Seven of these registers are dedicated to store one local alert temperature threshold limit and six remote alert temperature threshold limits (see the ALERT Interrupt Mode section). The remaining four registers are dedicated to remote channels 1, 4, 5, and 6 to store overtemperature threshold limits (see the OVERT Overtemperature Alarms section). Access to these registers is provided through the SMBus interface. ALERT Interrupt Mode An ALERT interrupt occurs when the internal or external temperature reading exceeds a high-temperature limit (user programmable). The ALERT output clears if the temperature goes below the high-temperature limit threshold. The ALERT interrupt output signal can also be cleared by reading the status register(s) associated with the fault(s) or by successfully responding to an alert response address transmission by the master. In both cases, the alert is cleared but is reasserted at the end of the next conversion if the fault condition still exists. The interrupt does not halt automatic conversions. The ALERT output is open drain so that multiple devices can share a common interrupt line. All ALERT interrupts can be masked using the configuration 3 register. The POR state of these registers is shown in Table 1. _______________________________________________________________________________________ 9 MAX6689 7-Channel Precision Temperature Monitor ALERT Response Address The SMBus alert response interrupt pointer provides quick fault identification for simple slave devices that lack the complex logic needed to be a bus master. Upon receiving an interrupt signal, the host master can broadcast a receive byte transmission to the alert response slave address (see the Slave Addresses section). Then, any slave device that generated an interrupt attempts to identify itself by putting its own address on the bus. The alert response can activate several different slave devices simultaneously, similar to the I2C* General Call. If more than one slave attempts to respond, bus arbitration rules apply, and the device with the lower address code wins. The losing device does not generate an acknowledgment and continues to hold the ALERT line low until cleared. (The conditions for clearing an alert vary depending on the type of slave device.) Successful completion of the alert response protocol clears the output latch. If the condition that caused the alert still exists, the MAX6689 reasserts the ALERT interrupt at the end of the next conversion. OVERT Overtemperature Alarms The MAX6689 has four overtemperature registers that store remote alarm threshold data for the OVERT output. OVERT is asserted when a channel’s measured temperature is greater than the value stored in the corresponding threshold register. OVERT remains asserted until the temperature drops below the programmed threshold minus 4°C hysteresis. An overtemperature output can be used to activate a cooling fan, send a warning, initiate clock throttling, or trigger a system shutdown to prevent component damage. See Table 3 for the POR state of the overtemperature threshold registers. Command Byte Functions The 8-bit command byte register (Table 3) is the master index that points to the various other registers within the MAX6689. This register’s POR state is 0000 0000. Configuration Byte Functions There are three read-write configuration registers (Tables 4, 5, and 6) that can be used to control the MAX6689’s operation. Configuration 1 Register The configuration 1 register (Table 4) has several functions. Bit 7 (MSB) is used to put the MAX6689 either in software standby mode (STOP) or continuous conversion mode. Bit 6 resets all registers to their power-on reset conditions and then clears itself. Bit 5 disables the SMBus timeout. Bit 4 enables more frequent conversions on channel 1, as described in the ADC Conversion Sequence section. Bit 3 enables resistance cancellation on channel 1. See the Series Resistance Cancellation section for more details. The remaining bits of the configuration 1 register are not used. The POR state of this register is 0000 0000 (00h). Configuration 2 Register The configuration 2 register functions are described in Table 5. Bits [6:0] are used to mask the ALERT interrupt output. Bit 6 masks the local alert interrupt and bits 5 through bit 0 mask the remote alert interrupts. The power-up state of this register is 0000 0000 (00h). Configuration 3 Register Table 6 describes the configuration 3 register. Bits 5, 4, 3, and 0 mask the OVERT interrupt output for channels 6, 5, 4, and 1. The remaining bits, 7, 6, 2, and 1, are reserved. The power-up state of this register is 0000 0000 (00h). Status Register Functions Status registers 1, 2, and 3 (Tables 7, 8, and 9) indicate which (if any) temperature thresholds have been exceeded and if there is an open-circuit or short-circuit fault detected with the external sense junctions. Status register 1 indicates if the measured temperature has exceeded the threshold limit set in the ALERT registers for the local or remote-sensing diodes. Status register 2 indicates if the measured temperature has exceeded the threshold limit set in the OVERT registers. Status register 3 indicates if there is a diode fault (open or short) in any of the remote-sensing channels. Bits in the alert status register clear by a successful read, but set again after the next conversion unless the fault is corrected, either by a drop in the measured temperature or an increase in the threshold temperature. The ALERT interrupt output follows the status flag bit. Once the ALERT output is asserted, it can be deasserted by either reading status register 1 or by successfully responding to an alert response address. *Purchase of I2C components from Maxim Integrated Products, Inc., or one of its sublicensed Associated Companies, conveys a license under the Philips I2C Patent Rights to use these components in an I2C system, provided that the system conforms to the I2C Standard Specification as defined by Philips. 10 ______________________________________________________________________________________ 7-Channel Precision Temperature Monitor MAX6689 Table 3. Command Byte Register Bit Assignment ADDRESS (HEX) POR STATE (HEX) READ/ WRITE Local 07 00 R Read local temperature register Remote 1 01 00 R Read channel 1 remote temperature register Remote 2 02 00 R Read channel 2 remote temperature register Remote 3 03 00 R Read channel 3 remote temperature register Remote 4 04 00 R Read channel 4 remote temperature register Remote 5 05 00 R Read channel 5 remote temperature register Remote 6 06 00 R Read channel 6 remote temperature register Configuration 1 41 00 R/W Read/write configuration register 1 Configuration 2 42 00 R/W Read/write configuration register 2 REGISTER DESCRIPTION Configuration 3 43 00 R/W Status1 44 00 R Read status register 1 Read/write configuration register 3 Status2 45 00 R Read status register 2 Read status register 3 Status3 46 00 R Local ALERT High Limit 17 5A R/W Read/write local alert high-temperature threshold limit register Remote 1 ALERT High Limit 11 6E R/W Read/write channel 1 remote-diode alert high-temperature threshold limit register Remote 2 ALERT High Limit 12 7F R/W Read/write channel 2 remote-diode alert high-temperature threshold limit register Remote 3 ALERT High Limit 13 64 R/W Read/write channel 3 remote-diode alert high-temperature threshold limit register Remote 4 ALERT High Limit 14 64 R/W Read/write channel 4 remote-diode alert high-temperature threshold limit register Remote 5 ALERT High Limit 15 64 R/W Read/write channel 5 remote-diode alert high-temperature threshold limit register Remote 6 ALERT High Limit 16 64 R/W Read/write channel 6 remote-diode alert high-temperature threshold limit register Remote 1 OVERT High Limit 21 6E R/W Read/write channel 1 remote-diode overtemperature threshold limit register Remote 4 OVERT High Limit 24 7F R/W Read/write channel 4 remote-diode overtemperature threshold limit register Remote 5 OVERT High Limit 25 5A R/W Read/write channel 5 remote-diode overtemperature threshold limit register Remote 6 OVERT High Limit 26 5A R/W Read/write channel 6 remote-diode overtemperature threshold limit register Remote 1 Extended Temperature 09 00 R Read channel 1 remote-diode extended temperature register Manufacturer ID 0A 4D R Read manufacturer ID ______________________________________________________________________________________ 11 MAX6689 7-Channel Precision Temperature Monitor Table 4. Configuration 1 Register BIT NAME POR STATE 7 (MSB) STOP 0 Standby-Mode Control Bit. If STOP is set to logic 1, the MAX6689 stops converting and enters standby mode. 6 POR 0 Reset Bit. Set to logic 1 to put the device into its power-on state. This bit is selfclearing. 5 TIMEOUT 0 Timeout Enable Bit. Set to logic 0 to enable SMBus timeout. 4 Fast remote 1 0 Channel 1 Fast-Conversion Bit. Set to logic 1 to enable fast conversion of channel 1. 3 Resistance cancellation 0 Resistance Cancellation Bit. When set to logic 1, the MAX6689 cancels series resistance in the channel 1 thermal diode. 2 Reserved 0 — 1 Reserved 0 — 0 Reserved 0 — FUNCTION Table 5. Configuration 2 Register NAME POR STATE 7 (MSB) Reserved 0 — 6 Mask Local ALERT 0 Local Alert Mask. Set to logic 1 to mask local channel ALERT. 5 Mask ALERT 6 0 Channel 6 Alert Mask. Set to logic 1 to mask channel 6 ALERT. 4 Mask ALERT 5 0 Channel 5 Alert Interrupt Mask. Set to logic 1 to mask channel 5 ALERT. 3 Mask ALERT 4 0 Channel 4 Alert Mask. Set to logic 1 to mask channel 4 ALERT. 2 Mask ALERT 3 0 Channel 3 Alert Interrupt Mask. Set to logic 1 to mask channel 3 ALERT. 1 Mask ALERT 2 0 Channel 2 Alert Mask. Set to logic 1 to mask channel 2 ALERT. 0 Mask ALERT 1 0 Channel 1 Alert Mask. Set to logic 1 to mask channel 1 ALERT. BIT FUNCTION In both cases, the alert is cleared even if the fault condition exists, but the ALERT output reasserts at the end of the next conversion. The bits indicating the fault for the OVERT interrupt output clear only on reading the status 2 register even if the fault conditions still exist. Reading the status 2 register does not clear the OVERT interrupt output. To eliminate the fault condition, either the measured temperature must drop below the temperature threshold minus the hysteresis value (4°C), or the trip temperature must be set at least 4°C above the current temperature. Applications Information Remote-Diode Selection The MAX6689 directly measures the die temperature of CPUs and other ICs that have on-chip temperaturesensing diodes (see the Typical Application Circuit) or 12 it can measure the temperature of a discrete diodeconnected transistor. Effect of Ideality Factor The accuracy of the remote temperature measurements depends on the ideality factor (n) of the remote “diode” (actually a transistor). The MAX6689 is optimized for n = 1.012. A thermal diode on the substrate of an IC is normally a pnp with the base and emitter brought out the collector (diode connection) grounded. DXP_ must be connected to the anode (emitter) and DXN_ must be connected to the cathode (base) of this pnp. If a sense transistor with an ideality factor other than 1.012 is used, the output data is different from the data obtained with the optimum ideality factor. Fortunately, the difference is predictable. Assume a remote-diode sensor designed for a nominal ideality ______________________________________________________________________________________ 7-Channel Precision Temperature Monitor MAX6689 Table 6. Configuration 3 Register BIT NAME POR STATE 7 (MSB) Reserved 0 — 6 Reserved 0 — 5 Mask OVERT 6 0 Channel 6 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 6 OVERT. 4 Mask OVERT 5 0 Channel 5 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 5 OVERT. 3 Mask OVERT 4 0 Channel 4 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 4 OVERT. 2 Reserved 0 — 1 Reserved 0 — 0 Mask OVERT 1 0 Channel 1 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 1 OVERT. FUNCTION factor nNOMINAL is used to measure the temperature of a diode with a different ideality factor n1. The measured temperature TM can be corrected using: n1 TM = TACTUAL nNOMINAL where temperature is measured in Kelvin and nNOMIMAL for the MAX6689 is 1.012. As an example, assume you want to use the MAX6689 with a CPU that has an ideality factor of 1.002. If the diode has no series resistance, the measured data is related to the real temperature as follows: n 1.012 TACTUAL = TM × NOMINAL = TM × = T (1.00998) 1.002 M n 1 For a real temperature of +85°C (358.15K), the measured temperature is +81.46°C (354.61K), an error of -3.539°C. Series Resistance Cancellation Some thermal diodes on high-power ICs can have excessive series resistance, which can cause temperature measurement errors with conventional remote temperature sensors. Channel 1 of the MAX6689 has a series resistance cancellation feature (enabled by bit 3 of the configuration 1 register) that eliminates the effect of diode series resistance. Set bit 3 to 1 if the series resistance is large enough to affect the accuracy of channel 1. The series resistance cancellation function increases the conversion time for channel 1 by 125ms. This feature cancels the bulk resistance of the sensor and any other resistance in series (wire, contact resistance, etc.). The cancellation range is from 0 to 100Ω. Discrete Remote Diodes When the remote-sensing diode is a discrete transistor, its collector and base must be connected together. Table 10 lists examples of discrete transistors that are appropriate for use with the MAX6689. The transistor must be a small-signal type with a relatively high forward voltage; otherwise, the A/D input voltage range can be violated. The forward voltage at the highest expected temperature must be greater than 0.25V at 10µA, and at the lowest expected temperature, the forward voltage must be less than 0.95V at 100µA. Large power transistors must not be used. Also, ensure that the base resistance is less than 100Ω. Tight specifications for forward current gain (50 < ß <150, for example) indicate that the manufacturer has good process controls and that the devices have consistent VBE characteristics. Manufacturers of discrete transistors do not normally specify or guarantee ideality factor. This is normally not a problem since good-quality discrete transistors tend to have ideality factors that fall within a relatively narrow range. We have observed variations in remote temperature readings of less than ±2°C with a variety of discrete transistors. Still, it is good design practice to verify good consistency of temperature readings with several discrete transistors from any manufacturer under consideration. ______________________________________________________________________________________ 13 MAX6689 7-Channel Precision Temperature Monitor Table 7. Status 1 Register BIT NAME POR STATE 7 (MSB) Reserved 0 — 6 Local ALERT 0 Local Channel High-Alert Bit. This bit is set to logic 1 when the local temperature exceeds the temperature threshold limit in the local ALERT highlimit register. 5 Remote 6 ALERT 0 Channel 6 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 6 remote-diode temperature exceeds the temperature threshold limit in the remote 6 ALERT high-limit register. 4 Remote 5 ALERT 0 Channel 5 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 5 remote-diode temperature exceeds the programmed temperature threshold limit in the remote 5 ALERT high-limit register. 3 Remote 4 ALERT 0 Channel 4 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 4 remote-diode temperature exceeds the temperature threshold limit in the remote 4 ALERT high-limit register. 2 Remote 3 ALERT 0 Channel 3 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 3 remote-diode temperature exceeds the programmed temperature threshold limit in the remote 3 ALERT high-limit register. 1 Remote 2 ALERT 0 Channel 2 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 2 remote-diode temperature exceeds the temperature threshold limit in the remote 2 ALERT high-limit register. 0 Remote 1 ALERT 0 Channel 1 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 1 remote-diode temperature exceeds the temperature threshold limit in the remote 1 ALERT high-limit register. FUNCTION Unused Diode Channels If one or more of the remote-diode channels is not needed, short the DXP and DXN pins for that channel together. The status register indicates a diode “fault” for this channel and the channel is ignored during the temperature-measurement sequence. Thermal Mass and Self-Heating When sensing local temperature, the MAX6689 measures the temperature of the PC board to which it is soldered. The leads provide a good thermal path between the PC board traces and the die. As with all IC temperature sensors, thermal conductivity between the die and the ambient air is poor by comparison, making air temperature measurements impractical. Because the thermal mass of the PC board is far greater than that of 14 the MAX6689, the device follows temperature changes on the PC board with little or no perceivable delay. When measuring the temperature of a CPU or other IC with an on-chip sense junction, thermal mass has virtually no effect; the measured temperature of the junction tracks the actual temperature within a conversion cycle. When measuring temperature with discrete remote transistors, the best thermal response times are obtained with transistors in small packages (i.e., SOT23 or SC70). Take care to account for thermal gradients between the heat source and the sensor, and ensure that stray air currents across the sensor package do not interfere with measurement accuracy. Self-heating does not significantly affect measurement accuracy. Remote-sensor self-heating due to the diode current source is negligible. ______________________________________________________________________________________ 7-Channel Precision Temperature Monitor BIT NAME POR STATE 7 (MSB) Reserved 0 — 6 Reserved 0 — 5 Remote 6 OVERT 0 Channel 6 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1 when the channel 6 remote-diode temperature exceeds the temperature threshold limit in the remote 6 OVERT high-limit register. 4 Remote 5 OVERT 0 Channel 5 Remote Diode Overtemperature Status Bit. This bit is set to logic 1 when the channel 5 remote-diode temperature exceeds the temperature threshold limit in the remote 5 OVERT high-limit register. 3 Remote 4 OVERT 0 Channel 4 Remote Diode Overtemperature Status Bit. This bit is set to logic 1 when the channel 4 remote-diode temperature exceeds the temperature threshold limit in the remote 4 OVERT high-limit register. 2 Reserved 0 — 1 Reserved 0 — 0 Remote 1 OVERT 0 Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1 when the channel 1 remote-diode temperature exceeds the temperature threshold limit in the remote 1 OVERT high-limit register. FUNCTION Table 9. Status 3 Register BIT NAME POR STATE 7 (MSB) Reserved 0 — 6 Diode fault 6 0 Channel 6 Remote-Diode Fault Bit. This bit is set to 1 when DXP6 and DXN6 are either shorted or open circuit. 5 Diode fault 5 0 Channel 5 Remote-Diode Fault Bit. This bit is set to 1 when DXP5 and DXN5 are either shorted or open circuit. 4 Diode fault 4 0 Channel 4 Remote-Diode Fault Bit. This bit is set to 1 when DXP4 and DXN4 are either shorted or open circuit. 3 Diode fault 3 0 Channel 3 Remote-Diode Fault Bit. This bit is set to 1 when DXP3 and DXN3 are either shorted or open circuit. 2 Diode fault 2 0 Channel 2 Remote-Diode Fault Bit. This bit is set to 1 when DXP2 and DXN2 are either shorted or open circuit. 1 Diode fault 1 0 Channel 1 Remote-Diode Fault Bit. This bit is set to 1 when DXP1 and DXN1 are either shorted or open circuit. 0 Reserved 0 — FUNCTION ______________________________________________________________________________________ 15 MAX6689 Table 8. Status 2 Register MAX6689 7-Channel Precision Temperature Monitor ADC Noise Filtering PC Board Layout The integrating ADC has good noise rejection for lowfrequency signals, such as power-supply hum. In environments with significant high-frequency EMI, connect an external 2200pF capacitor between DXP_ and DXN_. Larger capacitor values can be used for added filtering, but do not exceed 3300pF because it can introduce errors due to the rise time of the switched current source. High-frequency noise reduction is needed for high-accuracy remote measurements. Noise can be reduced with careful PC board layout as discussed in the PC Board Layout section. Follow these guidelines to reduce the measurement error when measuring remote temperature: Table 10. Remote-Sensors Transistor Manufacturer MANUFACTURER MODEL NO. Central Semiconductor (USA) CMPT3904 Rohm Semiconductor (USA) SST3904 Samsung (Korea) KST3904-TF Siemens (Germany) SMBT3904 Zetex (England) FMMT3904CT-ND Note: Discrete transistors must be diode connected (base shorted to collector). Slave Address Table 11 shows the MAX6689 slave addresses. Table 11. Slave Address PART SMBus SLAVE ID PIN-PACKAGE MAX6689EP34 0011 010 20 QSOP MAX6689EP38 0011 100 20 QSOP MAX6689EP9A 1001 101 20 QSOP MAX6689EP9E 1001 111 20 QSOP MAX6689UP34 0011 010 20 TSSOP MAX6689UP38 0011 100 20 TSSOP MAX6689UP9A 1001 101 20 TSSOP MAX6689UP9E 1001 111 20 TSSOP 1) Place the MAX6689 as close as is practical to the remote diode. In noisy environments, such as a computer motherboard, this distance can be 4in to 8in (typ). This length can be increased if the worst noise sources are avoided. Noise sources include CRTs, clock generators, memory buses, and PCI buses. 2) Do not route the DXP-DXN lines next to the deflection coils of a CRT. Also, do not route the traces across fast digital signals, which can easily introduce +30°C error, even with good filtering. 3) Route the DXP and DXN traces in parallel and in close proximity to each other. Each parallel pair of traces should go to a remote diode. Route these traces away from any higher voltage traces, such as +12VDC. Leakage currents from PC board contamination must be dealt with carefully since a 20MΩ leakage path from DXP to ground causes about +1°C error. If high-voltage traces are unavoidable, connect guard traces to GND on either side of the DXP-DXN traces (Figure 5). 4) Route through as few vias and crossunders as possible to minimize copper/solder thermocouple effects. 5) Use wide traces when practical. 5mil to 10mil traces are typical. Be aware of the effect of trace resistance on temperature readings when using long, narrow traces. 6) When the power supply is noisy, add a resistor (up to 47Ω) in series with VCC. GND 5–10 mils 5–10 mils DXP MINIMUM 5–10 mils DXN 5–10 mils GND Figure 5. Recommended DXP-DXN PC Board Traces. The two outer guard traces are recommended if high-voltage traces will be near the DXN and DXP traces. 16 ______________________________________________________________________________________ 7-Channel Precision Temperature Monitor Pin Configuration TOP VIEW + DXP1 1 20 GND DXN1 2 19 SMBCLK DXP2 3 18 SMBDATA 17 ALERT DXN2 4 DXP3 5 MAX6689 16 VCC DXN3 6 15 OVERT DXP4 7 14 N.C. DXN4 8 13 STBY DXP5 9 12 DXP6 DXN5 10 11 DXN6 QSOP/TSSOP Chip Information PROCESS: BiCMOS ______________________________________________________________________________________ 17 MAX6689 Twisted-Pair and Shielded Cables Use a twisted-pair cable to connect the remote sensor for remote-sensor distances longer than 8in or in very noisy environments. Twisted-pair cable lengths can be between 6ft and 12ft before noise introduces excessive errors. For longer distances, the best solution is a shielded twisted pair like that used for audio microphones. For example, Belden #8451 works well for distances up to 100ft in a noisy environment. At the device, connect the twisted pair to DXP and DXN and the shield to GND. Leave the shield unconnected at the remote sensor. For very long cable runs, the cable’s parasitic capacitance often provides noise filtering, so the 2200pF capacitor can often be removed or reduced in value. Cable resistance also affects remotesensor accuracy. For every 1Ω of series resistance the error is approximately +1/2°C. Package Information (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to www.maxim-ic.com/packages.) QSOP.EPS MAX6689 7-Channel Precision Temperature Monitor PACKAGE OUTLINE, QSOP .150", .025" LEAD PITCH 21-0055 18 ______________________________________________________________________________________ F 1 1 7-Channel Precision Temperature Monitor TSSOP4.40mm.EPS PACKAGE OUTLINE, TSSOP 4.40mm BODY 21-0066 G 1 1 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 19 © 2006 Maxim Integrated Products is a registered trademark of Maxim Integrated Products, Inc. MAX6689 Package Information (continued) (The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information, go to www.maxim-ic.com/packages.)