MAXIM MAX6693

19-4096; Rev 0; 5/08
7-Channel Precision Temperature Monitor
with Beta Compensation
The MAX6693 precision multichannel temperature sensor monitors its own temperature and the temperatures
of up to six external diode-connected transistors. All
temperature channels have programmable alert thresholds. Channels 1, 4, 5, and 6 also have programmable
overtemperature thresholds. When the measured temperature of a channel exceeds the respective threshold, a status bit is set in one of the status registers. Two
open-drain outputs, OVERT and ALERT, assert corresponding to these bits in the status register.
The 2-wire serial interface supports the standard system
management bus (SMBus™) protocols: write byte, read
byte, send byte, and receive byte for reading the temperature data and programming the alarm thresholds.
The MAX6693 is specified for an operating temperature
range of -40°C to +125°C and is available in a 20-pin
TSSOP package.
Features
♦ Six Thermal-Diode Inputs
♦ Beta Compensation (Channel 1)
♦ Local Temperature Sensor
♦ 1.5°C Remote Temperature Accuracy (+60°C to
+100°C)
♦ Temperature Monitoring Begins at POR for FailSafe System Protection
♦ ALERT and OVERT Outputs for Interrupts,
Throttling, and Shutdown
♦ STBY Input for Hardware Standby Mode
♦ Small, 20-Pin TSSOP Package
♦ 2-Wire SMBus Interface
Ordering Information
PART
Applications
TEMP RANGE
MAX6693UP9A+
Desktop Computers
Notebook Computers
Workstations
Servers
-40°C to +125°C
PIN-PACKAGE
20 TSSOP
+Denotes a lead-free package.
Note: Slave address is 1001 101.
SMBus is a trademark of Intel Corp.
Pin Configuration appears at end of data sheet.
Typical Application Circuit
+3.3V
CPU
1
DXP1
GND 20
4.7kΩ
EACH
2
DXN1
MAX6693 SMBCLK 19
CLK
3
DXP2
SMBDATA 18
4
DXN2
ALERT 17
5
DXP3
VCC 16
6
DXN3
OVERT 15
7
DXP4
N.C. 14
8
DXN4
STBY 13
9
DXP5
DXP6 12
10
DXN5
DXN6 11
100pF
DATA
100pF
INTERRUPT
TO μP
0.1μF
100pF
TO SYSTEM
SHUTDOWN
100pF
GPU
100pF
100pF
________________________________________________________________ Maxim Integrated Products
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
1
MAX6693
General Description
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
ABSOLUTE MAXIMUM RATINGS
VCC, SMBCLK, SMBDATA, ALERT, OVERT,
STBY to GND ....................................................-0.3V to +6.0V
DXP_ to GND..............................................-0.3V to (VCC + 0.3V)
DXN_ to GND ........................................................-0.3V to +0.8V
SMBDATA, ALERT, OVERT Current....................-1mA to +50mA
DXN_ Current......................................................................±1mA
Continuous Power Dissipation (TA = +70°C)
20-Pin TSSOP
(derate 13.6mW/°C above +70°C) .............................1084mW
Junction-to-Case Thermal Resistance (θJC) (Note 1)
20-Pin TSSOP...............................................................20°C/W
Junction-to-Ambient Thermal Resistance (θJA) (Note 1)
20-Pin TSSOP............................................................73.8°C/W
ESD Protection (all pins, Human Body Model) ....................±2kV
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a fourlayer board. For detailed information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = +3.0V to +3.6V, VSTBY = VCC, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VCC = +3.3V and TA =
+25°C.) (Note 2)
PARAMETER
Supply Voltage
SYMBOL
CONDITIONS
VCC
MIN
TYP
3.0
MAX
UNITS
3.6
V
Software Standby Supply Current
ISS
SMBus static
3
10
µA
Operating Current
ICC
During conversion (Note 3)
500
2000
µA
Channel 1 only
11
Other diode channels
8
Temperature Resolution
3 σ Temperature Accuracy
(Remote Channel 1)
VCC = 3.3V,
ß = 0.5
3 σ Temperature Accuracy
(Remote Channels 2–6)
VCC = 3.3V
3 σ Temperature Accuracy
(Local)
VCC = 3.3V
6 σ Temperature Accuracy
(Remote Channel 1)
VCC = 3.3V,
ß = 0.5
6 σ Temperature Accuracy
(Remote Channels 2–6)
VCC = 3.3V
6 σ Temperature Accuracy
(Local)
VCC = 3.3V
TA = TRJ = +60°C to +100°C
TA = TRJ = 0°C to +125°C
TA = TRJ = +60°C to +100°C
Bits
-1.5
+1.5
-2.375
+2.375
-2
+2
-2.5
+2.5
-2
+2
-2.5
+2.5
TA = TRJ = +60°C to +100°C
-3
+3
TA = TRJ = 0°C to +125°C
-4
+4
TA = TRJ = 0°C to +125°C
TA = +60°C to +100°C
TA = 0°C to +125°C
-3
+3
TA = TRJ = 0°C to +125°C
TA = TRJ = +60°C to +100°C
-3.5
+3.5
TA = +60°C to +100°C
-2.5
+2.5
-3
+3
TA = 0°C to +125°C
Supply Sensitivity of Temperature
Accuracy
±0.2
°C
°C
°C
°C
°C
°C
o
C/V
Remote Channel 1 Conversion
Time
tCONV1
190
250
312
ms
Remote Channels 2–6
Conversion Time
tCONV_
95
125
156
ms
2
_______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
(VCC = +3.0V to +3.6V, VSTBY = VCC, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VCC = +3.3V and TA =
+25°C.) (Note 2)
PARAMETER
Remote-Diode Source Current
SYMBOL
IRJ
CONDITIONS
UVLO
TYP
500
Low level, channel 1
20
High level, channels 2–6
Low level, channels 2–6
Undervoltage-Lockout Threshold
MIN
High level, channel 1
80
100
MAX
120
8
10
12
Falling edge of VCC disables ADC
2.30
2.80
2.95
VCC falling edge
1.20
Undervoltage-Lockout Hysteresis
90
Power-On Reset (POR) Threshold
POR Threshold Hysteresis
2
UNITS
µA
V
mV
2.25
90
V
mV
ALERT, OVERT
Output Low Voltage
VOL
ISINK = 1mA
0.3
ISINK = 6mA
0.5
Output Leakage Current
1
V
µA
SMBus INTERFACE (SMBCLK, SMBDATA), STBY
Logic-Input Low Voltage
VIL
Logic-Input High Voltage
VIH
0.8
VCC = 3.0V
Input Leakage Current
2.2
-1
Output Low Voltage
VOL
Input Capacitance
CIN
V
V
+1
ISINK = 6mA
0.3
5
µA
V
pF
SMBus-COMPATIBLE TIMING (Figures 3 and 4) (Note 4)
Serial-Clock Frequency
Bus Free Time Between STOP
and START Condition
fSMBCLK
tBUF
START Condition Setup Time
Repeat START Condition Setup
Time
tSU:STA
START Condition Hold Time
tHD:STA
STOP Condition Setup Time
tSU:STO
(Note 5)
400
fSMBCLK = 100kHz
4.7
fSMBCLK = 400kHz
1.6
fSMBCLK = 100kHz
4.7
fSMBCLK = 400kHz
0.6
90% of SMBCLK to 90% of SMBDATA,
fSMBCLK = 100kHz
0.6
90% of SMBCLK to 90% of SMBDATA,
fSMBCLK = 400kHz
0.6
10% of SMBDATA to 90% of SMBCLK
0.6
90% of SMBCLK to 90% of SMBDATA,
fSMBCLK = 100kHz
4
90% of SMBCLK to 90% of SMBDATA,
fSMBCLK = 400kHz
0.6
kHz
µs
µs
µs
µs
µs
_______________________________________________________________________________________
3
MAX6693
ELECTRICAL CHARACTERISTICS (continued)
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
ELECTRICAL CHARACTERISTICS (continued)
(VCC = +3.0V to +3.6V, VSTBY = VCC, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VCC = +3.3V and TA =
+25°C.) (Note 2)
PARAMETER
SYMBOL
Clock-Low Period
tLOW
Clock-High Period
tHIGH
Data Hold Time
tHD:DAT
Data Setup Time
tSU:DAT
Receive SMBCLK/SMBDATA
Rise Time
tR
Receive SMBCLK/SMBDATA Fall
Time
tF
Pulse Width of Spike Suppressed
SMBus Timeout
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
4
CONDITIONS
1.3
10% to 10%, fSMBCLK = 400kHz
1.3
90% to 90%
0.6
fSMBCLK = 100kHz
300
TYP
MAX
µs
900
fSMBCLK = 100kHz
250
fSMBCLK = 400kHz
100
1
fSMBCLK = 400kHz
0.3
300
0
25
ns
ns
fSMBCLK = 100kHz
SMBDATA low period for interface reset
UNITS
µs
fSMBCLK = 400kHz (Note 6)
tSP
tTIMEOUT
MIN
10% to 10%, fSMBCLK = 100kHz
37
µs
ns
50
ns
45
ms
All parameters are tested at TA = +85°C. Specifications over temperature are guaranteed by design.
Beta = 0.5 for channel 1 remote transistor.
Timing specifications are guaranteed by design.
The serial interface resets when SMBCLK is low for more than tTIMEOUT.
A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SMBCLK’s falling edge.
_______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
SUPPLY CURRENT
vs. SUPPLY VOLTAGE
SOFTWARE STANDBY SUPPLY CURRENT
vs. SUPPLY VOLTAGE
3.7
LOW BETA DIODE CONNECTED TO
CHANNEL 1 WITH RESISTANCE
CANCELLATION AND LOW BETA
560
SUPPLY CURRENT (μA)
3.6
3.5
3.4
3.3
540
520
500
480
460
3.2
440
3.1
420
400
3.0
3.2
3.3
3.4
3.2
3.0
3.6
3.5
0
-1
-2
2
1
0
-1
CHANNEL 1
-3
-5
50
75
100
0
125
25
CHANNEL 2
1
0
-1
-2
CHANNEL 1
50
75
100
125
-5
0.001
DIE TEMPERATURE (°C)
REMOTE-DIODE TEMPERATURE (°C)
LOCAL TEMPERATURE ERROR
vs. POWER-SUPPLY NOISE FREQUENCY
100mVP-P
4
0.100
1.000
10.000
FREQUENCY (MHz)
4
2
1
0
-1
-2
100mVP-P
3
TEMPERATURE ERROR (°C)
3
0.010
CH 2 REMOTE-DIODE TEMPERATURE ERROR
vs. COMMON-MODE NOISE FREQUENCY
MAX6693 toc06
5
2
1
0
-1
-2
-3
-3
-4
-4
-5
0.001
2
-4
-3
25
3
-3
-2
-4
0
100mVP-P
4
TEMPERATURE ERROR (°C)
3
TEMPERATURE ERROR (°C)
CHANNEL 2
1
5
MAX6693 toc04
4
MAX6693 toc03
3
TEMPERATURE ERROR (°C)
TEMPERATURE ERROR (°C)
4
3.6
REMOTE-DIODE TEMPERATURE ERROR
vs. POWER-SUPPLY NOISE FREQUENCY
LOCAL TEMPERATURE ERROR
vs. DIE TEMPERATURE
REMOTE-DIODE TEMPERATURE ERROR
vs. REMOTE-DIODE TEMPERATURE
5
3.4
SUPPLY VOLTAGE (V)
SUPPLY VOLTAGE (V)
MAX6693 toc05
3.1
MAX6693 toc07
3.0
2
MAX6693 toc02
580
MAX6693 toc01
STANDBY SUPPLY CURRENT (μA)
3.8
-5
0.010
0.100
FREQUENCY (MHz)
1.000
10.000
0.1
1.0
10.0
FREQUENCY (MHz)
_______________________________________________________________________________________
5
MAX6693
Typical Operating Characteristics
(VCC = 3.3V, VSTBY = VCC, TA = +25°C, unless otherwise noted.)
Typical Operating Characteristics (continued)
(VCC = 3.3V, VSTBY = VCC, TA = +25°C, unless otherwise noted.)
CH 1 REMOTE-DIODE TEMPERATURE
ERROR vs. CAPACITANCE
CH 2 REMOTE-DIODE TEMPERATURE
ERROR vs. CAPACITANCE
4
4
TEMPERATURE ERROR (°C)
3
2
1
0
-1
-2
3
2
1
0
-1
-2
-3
-3
-4
-4
-5
MAX6693 toc09
5
MAX6693 toc08
5
TEMPERATURE ERROR (°C)
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
-5
1
10
100
1
CAPACITANCE (nF)
10
100
CAPACITANCE (nF)
Pin Description
6
PIN
NAME
FUNCTION
1
DXP1
Combined Current Source and A/D Positive Input for Channel 1 Remote Transistor. Connect to the
emitter of a low-beta transistor. Leave unconnected or connect to VCC if no remote transistor is used.
Place a 100pF capacitor between DXP1 and DXN1 for noise filtering.
2
DXN1
Base Input for Channel 1 Remote Diode. Connect to the base of a PNP temperature-sensing transistor.
3
DXP2
Combined Current Source and A/D Positive Input for Channel 2 Remote Diode. Connect to the anode
of a remote-diode-connected temperature-sensing transistor. Leave unconnected or connect to VCC
if no remote diode is used. Place a 100pF capacitor between DXP2 and DXN2 for noise filtering.
4
DXN2
Cathode Input for Channel 2 Remote Diode. Connect the cathode of the channel 2 remote-diodeconnected transistor to DXN2.
5
DXP3
Combined Current Source and A/D Positive Input for Channel 3 Remote Diode. Connect to the anode
of a remote-diode-connected temperature-sensing transistor. Leave unconnected or connect to VCC
if no remote diode is used. Place a 100pF capacitor between DXP3 and DXN3 for noise filtering.
6
DXN3
Cathode Input for Channel 3 Remote Diode. Connect the cathode of the channel 3 remote-diodeconnected transistor to DXN3.
7
DXP4
Combined Current Source and A/D Positive Input for Channel 4 Remote Diode. Connect to the anode
of a remote-diode-connected temperature-sensing transistor. Leave unconnected or connect to VCC
if no remote diode is used. Place a 100pF capacitor between DXP4 and DXN4 for noise filtering.
8
DXN4
Cathode Input for Channel 4 Remote Diode. Connect the cathode of the channel 4 remote-diodeconnected transistor to DXN4.
_______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
PIN
NAME
FUNCTION
9
DXP5
Combined Current Source and A/D Positive Input for Channel 5 Remote Diode. Connect to the anode
of a remote-diode-connected temperature-sensing transistor. Leave unconnected or connect to VCC
if no remote diode is used. Place a 100pF capacitor between DXP5 and DXN5 for noise filtering.
10
DXN5
Cathode Input for Channel 5 Remote Diode. Connect the cathode of the channel 5 remote-diodeconnected transistor to DXN5.
11
DXN6
Cathode Input for Channel 6 Remote Diode. Connect the cathode of the channel 6 remote-diodeconnected transistor to DXN6.
12
DXP6
Combined Current Source and A/D Positive Input for Channel 6 Remote Diode. Connect to the anode
of a remote-diode-connected temperature-sensing transistor. Leave unconnected or connect to VCC
if no remote diode is used. Place a 100pF capacitor between DXP6 and DXN6 for noise filtering.
13
STBY
Active-Low Standby Input. Drive STBY logic-low to place the MAX6693 in standby mode, or logic-high
for operate mode. Temperature and threshold data are retained in standby mode.
14
N.C.
No Connection. Must be connected to ground.
15
OVERT
16
VCC
Overtemperature Active-Low, Open-Drain Output. OVERT asserts low when the temperature of
channels 1, 4, 5, and 6 exceeds the programmed threshold limit.
Supply Voltage Input. Bypass to GND with a 0.1µF capacitor.
17
ALERT
18
SMBDATA
19
SMBCLK
20
GND
SMBus Alert (Interrupt), Active-Low, Open-Drain Output. ALERT asserts low when the temperature of
any channel exceeds the programmed ALERT threshold.
SMBus Serial Data Input/Output. Connect to a pullup resistor.
SMBus Serial Clock Input. Connect to a pullup resistor.
Ground
Detailed Description
The MAX6693 is a precision multichannel temperature
monitor that features one local and six remote temperature-sensing channels with a programmable alert
threshold for each temperature channel and a programmable overtemperature threshold for channels 1, 4, 5,
and 6 (see Figure 1). Communication with the MAX6693
is achieved through the SMBus serial interface and a
dedicated alert pin. The alarm outputs, OVERT and
ALERT, assert if the software-programmed temperature
thresholds are exceeded. ALERT typically serves as an
interrupt, while OVERT can be connected to a fan, system shutdown, or other thermal-management circuitry.
ADC Conversion Sequence
In the default conversion mode, the MAX6693 starts the
conversion sequence by measuring the temperature on
channel 1, followed by 2, 3, local channel, 4, 5, and 6.
The conversion result for each active channel is stored
in the corresponding temperature data register.
Low-Power Standby Mode
Enter software standby mode by setting the STOP bit to
1 in the configuration 1 register. Enter hardware standby
by pulling STBY low. Software standby mode disables
the ADC and reduces the supply current to approximately 3µA. Hardware standby mode halts the ADC
clock, but the supply current is approximately 350µA.
During either software or hardware standby, data is
retained in memory. During hardware standby, the
SMBus interface is inactive. During software standby, the
SMBus interface is active and listening for commands.
The timeout is enabled if a start condition is recognized
on SMBus. Activity on the SMBus causes the supply current to increase. If a standby command is received while
a conversion is in progress, the conversion cycle is interrupted, and the temperature registers are not updated.
The previous data is not changed and remains available.
_______________________________________________________________________________________
7
MAX6693
Pin Description (continued)
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
VCC
DXP
MAX6693
DXN
DXP2
ALARM
ALU
DXN2
DXP3
DXN3
DXP4
CURRENT
SOURCES,
BETA
COMPENSATION
AND MUX
INPUT
BUFFER
ADC
OVERT
ALERT
REGISTER BANK
COMMAND BYTE
REMOTE TEMPERATURES
DXN4
DXP5
LOCAL TEMPERATURES
REF
ALERT THRESHOLD
OVERT THRESHOLD
DXN5
ALERT RESPONSE ADDRESS
DXP6
SMBus
INTERFACE
DXN6
STBY
SMBCLK
SMBDATA
Figure 1. Internal Block Diagram
Operating-Current Calculation
SMBus Digital Interface
The MAX6693 operates at different operating-current
levels depending on how many external channels are in
use. Assume that ICC1 is the operating current when
the MAX6693 is converting the remote channel 1 and
ICC2 is the operating current when the MAX6693 is converting the other channels. For the MAX6693 with
remote channel 1 and n other remote channels connected, the operating current is:
ICC = (2 x ICC1 + ICC2 + n x ICC2)/(n + 3)
From a software perspective, the MAX6693 appears as
a series of 8-bit registers that contain temperature measurement data, alarm threshold values, and control bits.
A standard SMBus-compatible, 2-wire serial interface is
used to read temperature data and write control bits
and alarm threshold data. The same SMBus slave
address also provides access to all functions.
8
_______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
MAX6693
WRITE BYTE FORMAT
S
ADDRESS
WR
ACK
COMMAND
7 BITS
ACK
DATA
8 BITS
ACK
P
8 BITS
SLAVE ADDRESS: EQUIVALENT TO CHIP-SELECT LINE OF
A 3-WIRE INTERFACE
1
DATA BYTE: DATA GOES INTO THE REGISTER
SET BY THE COMMAND BYTE (TO SET
THRESHOLDS, CONFIGURATION MASKS, AND
SAMPLING RATE)
READ BYTE FORMAT
S
ADDRESS
WR
ACK
7 BITS
COMMAND
ACK
S
SLAVE ADDRESS: EQUIVALENT TO CHIP SELECT LINE
ADDRESS
RD
COMMAND BYTE: SELECTS
WHICH REGISTER YOU ARE
REDING FROM
DATA
///
P
8 BITS
SLAVE ADDRESS: REPEATED
DUE TO CHANGE IN DATAFLOW DIRECTION
DATA BYTE: READS FROM
THE REGISTER SET BY THE
COMMAND BYTE
RECEIVE BYTE FORMAT
WR
ACK
7 BITS
COMMAND
ACK
P
8 BITS
S
ADDRESS
RD
7 BITS
ACK
DATA
///
P
8 BITS
COMMAND BYTE: SENDS COMMAND WITH NO DATA, USUALLY
USED FOR ONE-SHOT COMMAND
S = START CONDITION.
P = STOP CONDITION.
ACK
7 BITS
SEND BYTE FORMAT
S
ADDRESS
8 BITS
DATA BYTE: READS DATA FROM
THE REGISTER COMMANDED
BY THE LAST READ BYTE OR
WRITE BYTE TRANSMISSION;
ALSO USED FOR SMBus ALERT
RESPONSE RETURN ADDRESS
SHADED = SLAVE TRANSMISSION.
/// = NOT ACKNOWLEDGED.
Figure 2. SMBus Protocols
Table 1. Main Temperature Register
(High-Byte) Data Format
Table 2. Extended Resolution Temperature
Register (Low-Byte) Data Format
TEMP (°C)
DIGITAL OUTPUT
TEMP (°C)
DIGITAL OUTPUT
> +127
0111 1111
0
000X XXXX
+127
0111 1111
+0.125
001X XXXX
+126
0111 1110
+0.250
010X XXXX
+25
0001 1001
+0.375
011X XXXX
0
0000 0000
+0.500
100X XXXX
<0
0000 0000
+0.625
101X XXXX
Diode fault (open or short)
1111 1111
+0.750
110X XXXX
+0.875
111X XXXX
The MAX6693 employs four standard SMBus protocols:
write byte, read byte, send byte, and receive byte
(Figure 2). The shorter receive byte protocol allows
quicker transfers, provided that the correct data register was previously selected by a read byte instruction.
Use caution with the shorter protocols in multimaster
systems, since a second master could overwrite the
command byte without informing the first master. Figure
3 is the SMBus write-timing diagram and Figure 4 is the
SMBus read-timing diagram.
The remote diode 1 measurement channel provides 11
bits of data (1 LSB = 0.125°C). All other temperaturemeasurement channels provide 8 bits of temperature
data (1 LSB = 1°C). The 8 most significant bits (MSBs)
can be read from the local temperature and remote
temperature registers. The remaining 3 bits for remote
diode 1 can be read from the extended temperature
register. If extended resolution is desired, the extended
resolution register should be read first. This prevents
the most significant bits from being overwritten by new
conversion results until they have been read. If the most
significant bits have not been read within an SMBus
timeout period (nominally 37ms), normal updating continues. Table 1 shows the main temperature register
(high-byte) data format, and Table 2 shows the extended resolution register (low-byte) data format.
_______________________________________________________________________________________
9
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
A
tLOW
B
C
tHIGH
E
D
F
G
I
H
J
K
M
L
SMBCLK
SMBDATA
tSU:STA
tHD:STA
tSU:DAT
A = START CONDITION.
B = MSB OF ADDRESS CLOCKED INTO SLAVE.
C = LSB OF ADDRESS CLOCKED INTO SLAVE.
D = R/W BIT CLOCKED INTO SLAVE.
E = SLAVE PULLS SMBDATA LINE LOW.
tHD:DAT
tSU:STO tBUF
J = ACKNOWLEDGE CLOCKED INTO SLAVE.
K = ACKNOWLEDGE CLOCK PULSE.
L = STOP CONDITION.
M = NEW START CONDITION.
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER.
G = MSB OF DATA CLOCKED INTO MASTER.
H = LSB OF DATA CLOCKED INTO MASTER.
I = MASTER PULLS DATA LINE LOW.
Figure 3. SMBus Write-Timing Diagram
A
B
tLOW
C
D
E
F
G
tHIGH
H
I
J
K
L
M
SMBCLK
SMBDATA
tSU:STA tHD:STA
tSU:STO
tSU:DAT
A = START CONDITION.
B = MSB OF ADDRESS CLOCKED INTO SLAVE.
C = LSB OF ADDRESS CLOCKED INTO SLAVE.
D = R/W BIT CLOCKED INTO SLAVE.
E = SLAVE PULLS SMBDATA LINE LOW.
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER.
G = MSB OF DATA CLOCKED INTO SLAVE.
H = LSB OF DATA CLOCKED INTO SLAVE.
tBUF
I = MASTER PULLS DATA LINE LOW.
J = ACKNOWLEDGE CLOCKED INTO SLAVE.
K = ACKNOWLEDGE CLOCK PULSE.
L = STOP CONDITION.
M = NEW START CONDITION.
Figure 4. SMBus Read-Timing Diagram
Diode Fault Detection
If a channel’s input DXP_ and DXN_ are left open, the
MAX6693 detects a diode fault. An open diode fault does
not cause either ALERT or OVERT to assert. A bit in the status register for the corresponding channel is set to 1 and the
temperature data for the channel is stored as all 1s (FFh). It
takes approximately 4ms for the MAX6693 to detect a diode
fault. Once a diode fault is detected, the MAX6693 goes to
the next channel in the conversion sequence.
Alarm Threshold Registers
There are 11 alarm threshold registers that store over-temperature ALERT and OVERT threshold values. Seven of
these registers are dedicated to storing one local alert temperature threshold limit and six remote alert temperature
threshold limits (see the ALERT Interrupt Mode section).
The remaining four registers are dedicated to remote channels 1, 4, 5, and 6 to store overtemperature threshold limits
10
(see the OVERT Overtemperature Alarms section). Access
to these registers is provided through the SMBus interface.
ALERT Interrupt Mode
An ALERT interrupt occurs when the internal or external
temperature reading exceeds a high-temperature limit
(user programmable). The ALERT interrupt output signal
can be cleared by reading the status register(s) associated with the fault(s) or by successfully responding to an
alert response address transmission by the master. In
both cases, the alert is cleared but is reasserted at the
end of the next conversion if the fault condition still
exists. The interrupt does not halt automatic conversions.
The ALERT output is open-drain so that multiple devices
can share a common interrupt line. All ALERT interrupts
can be masked using the configuration 3 register. The
POR state of these registers is shown in Table 1.
______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
OVERT Overtemperature Alarms
The MAX6693 has four overtemperature registers that
store remote alarm threshold data for the OVERT output.
OVERT is asserted when a channel’s measured temperature is greater than the value stored in the corresponding threshold register. OVERT remains asserted until the
temperature drops below the programmed threshold
minus 4°C hysteresis. An overtemperature output can
be used to activate a cooling fan, send a warning, initiate clock throttling, or trigger a system shutdown to prevent component damage. See Table 3 for the POR state
of the overtemperature threshold registers.
Command Byte Functions
The 8-bit command byte register (Table 3) is the master
index that points to the various other registers within the
MAX6693. This register’s POR state is 0000 0000.
Configuration Byte Functions
There are three read-write configuration registers
(Tables 4, 5, and 6) that can be used to control the
MAX6693’s operation.
Configuration 1 Register
The configuration 1 register (Table 4) has several functions. Bit 7 (MSB) is used to put the MAX6693 either in
software standby mode (STOP) or continuous conversion mode. Bit 6 resets all registers to their POR conditions and then clears itself. Bit 5 disables the SMBus
timeout. Bit 3 enables resistance cancellation on channel 1. See the Series Resistance Cancellation section
for more details. Bit 2 enables beta compensation on
channel 1. See the Beta Compensation section for more
details. The remaining bits of the configuration 1 register are not used. The POR state of this register is 0000
1100 (0Ch).
Configuration 2 Register
The configuration 2 register functions are described in
Table 5. Bits [6:0] are used to mask the ALERT interrupt
output. Bit 6 masks the local alert interrupt and bits 5
through bit 0 mask the remote alert interrupts. The
power-up state of this register is 0000 0000 (00h).
Configuration 3 Register
Table 6 describes the configuration 3 register. Bits 5, 4, 3,
and 0 mask the OVERT interrupt output for channels 6, 5,
4, and 1. The remaining bits, 7, 6, 2, and 1, are reserved.
The power-up state of this register is 0000 0000 (00h).
Status Register Functions
Status registers 1, 2, and 3 (Tables 7, 8, and 9) indicate
which (if any) temperature thresholds have been
exceeded and if there is an open-circuit or short-circuit
fault detected with the external sense junctions. Status
register 1 indicates if the measured temperature has
exceeded the threshold limit set in the ALERT registers
for the local or remote-sensing diodes. Status register 2
indicates if the measured temperature has exceeded
the threshold limit set in the OVERT registers. Status
register 3 indicates if there is a diode fault (open or
short) in any of the remote-sensing channels.
Bits in the alert status register clear by a successful
read, but set again after the next conversion unless the
fault is corrected, either by a drop in the measured temperature or an increase in the threshold temperature.
The ALERT interrupt output follows the status flag bit.
Once the ALERT output is asserted, it can be
deasserted by either reading status register 1 or by
successfully responding to an alert response address.
In both cases, the alert is cleared even if the fault condi-
______________________________________________________________________________________
11
MAX6693
ALERT Response Address
The SMBus alert response interrupt pointer provides
quick fault identification for simple slave devices that
lack the complex logic needed to be a bus master.
Upon receiving an interrupt signal, the host master can
broadcast a receive byte transmission to the alert
response slave address (see the Slave Address section). Then, any slave device that generated an interrupt attempts to identify itself by putting its own
address on the bus.
The alert response can activate several different slave
devices simultaneously, similar to the I2C General Call.
If more than one slave attempts to respond, bus arbitration rules apply, and the device with the lower address
code wins. The losing device does not generate an
acknowledgment and continues to hold the ALERT line
low until cleared. (The conditions for clearing an alert
vary depending on the type of slave device.)
Successful completion of the alert response protocol
clears the output latch. If the condition that caused the
alert still exists, the MAX6693 reasserts the ALERT
interrupt at the end of the next conversion.
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
Table 3. Command Byte Register Bit Assignment
ADDRESS
(HEX)
POR STATE
(HEX)
READ/
WRITE
Local
07
00
R
Read local temperature register
Remote 1
01
00
R
Read channel 1 remote temperature register
Remote 2
02
00
R
Read channel 2 remote temperature register
Remote 3
03
00
R
Read channel 3 remote temperature register
Remote 4
04
00
R
Read channel 4 remote temperature register
Remote 5
05
00
R
Read channel 5 remote temperature register
Remote 6
06
00
R
Read channel 6 remote temperature register
Configuration 1
41
0C
R/W
Read/write configuration register 1
Configuration 2
42
00
R/W
Read/write configuration register 2
REGISTER
DESCRIPTION
Configuration 3
43
00
R/W
Status1
44
00
R
Read status register 1
Read/write configuration register 3
Status2
45
00
R
Read status register 2
Read status register 3
Status3
46
00
R
Local ALERT High Limit
17
5A
R/W
Read/write local alert high-temperature threshold limit register
Remote 1 ALERT High Limit
11
6E
R/W
Read/write channel 1 remote-diode alert high-temperature
threshold limit register
Remote 2 ALERT High Limit
12
7F
R/W
Read/write channel 2 remote-diode alert high-temperature
threshold limit register
Remote 3 ALERT High Limit
13
64
R/W
Read/write channel 3 remote-diode alert high-temperature
threshold limit register
Remote 4 ALERT High Limit
14
64
R/W
Read/write channel 4 remote-diode alert high-temperature
threshold limit register
Remote 5 ALERT High Limit
15
64
R/W
Read/write channel 5 remote-diode alert high-temperature
threshold limit register
Remote 6 ALERT High Limit
16
64
R/W
Read/write channel 6 remote-diode alert high-temperature
threshold limit register
Remote 1 OVERT High Limit
21
6E
R/W
Read/write channel 1 remote-diode overtemperature threshold
limit register
Remote 4 OVERT High Limit
24
7F
R/W
Read/write channel 4 remote-diode overtemperature threshold
limit register
Remote 5 OVERT High Limit
25
5A
R/W
Read/write channel 5 remote-diode overtemperature threshold
limit register
Remote 6 OVERT High Limit
26
5A
R/W
Read/write channel 6 remote-diode overtemperature threshold
limit register
Remote 1 Extended
Temperature
09
00
R
Read channel 1 remote-diode extended temperature register
Manufacturer ID
0A
4D
R
Read manufacturer ID
12
______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
BIT
NAME
POR
STATE
7 (MSB)
STOP
0
Standby-Mode Control Bit. If STOP is set to logic 1, the MAX6693 stops
converting and enters standby mode.
6
POR
0
Reset Bit. Set to logic 1 to put the device into its power-on state. This bit is selfclearing.
5
TIMEOUT
0
Timeout Enable Bit. Set to logic 0 to enable SMBus timeout.
4
RESERVED
0
Reserved. Must set to 0.
3
Resistance
cancellation
1
Resistance Cancellation Bit. When set to logic 1, the MAX6693 cancels series
resistance in the channel 1 thermal diode.
2
Beta compensation
1
Beta Compensation Bit. When set to logic 1, the MAX6693 compensates for low
beta in the channel 1 thermal sensing transistor.
1
Reserved
0
—
0
Reserved
0
—
FUNCTION
Table 5. Configuration 2 Register
BIT
NAME
POR
STATE
7 (MSB)
Reserved
0
—
6
Mask Local ALERT
0
Local Alert Mask. Set to logic 1 to mask local channel ALERT.
5
Mask ALERT 6
0
Channel 6 Alert Mask. Set to logic 1 to mask channel 6 ALERT.
4
Mask ALERT 5
0
Channel 5 Alert Mask. Set to logic 1 to mask channel 5 ALERT.
3
Mask ALERT 4
0
Channel 4 Alert Mask. Set to logic 1 to mask channel 4 ALERT.
2
Mask ALERT 3
0
Channel 3 Alert Mask. Set to logic 1 to mask channel 3 ALERT.
1
Mask ALERT 2
0
Channel 2 Alert Mask. Set to logic 1 to mask channel 2 ALERT.
0
Mask ALERT 1
0
Channel 1 Alert Mask. Set to logic 1 to mask channel 1 ALERT.
FUNCTION
tion exists, but the ALERT output reasserts at the end of
the next conversion. The bits indicating the fault for the
OVERT interrupt output clear only on reading the status 2
register even if the fault conditions still exist. Reading the
status 2 register does not clear the OVERT interrupt output. To eliminate the fault condition, either the measured
temperature must drop below the temperature threshold
minus the hysteresis value (4°C), or the trip temperature
must be set at least 4°C above the current temperature.
Applications Information
Remote-Diode Selection
The MAX6693 directly measures the die temperature of
CPUs and other ICs that have on-chip temperaturesensing diodes (see the Typical Application Circuit) or
it can measure the temperature of a discrete diodeconnected transistor.
Effect of Ideality Factor
The accuracy of the remote temperature measurements depends on the ideality factor (n) of the remote
“diode” (actually a transistor). The MAX6693 is optimized for n = 1.006 (channel 1) and n = 1.008 (channels 2–6). A thermal diode on the substrate of an IC is
normally a pnp with the base and emitter brought out to
the collector (diode connection) grounded. DXP_ must
be connected to the anode (emitter) and DXN_ must be
connected to the cathode (base) of this pnp. If a sense
transistor with an ideality factor other than 1.006 or
1.008 is used, the output data is different from the data
obtained with the optimum ideality factor. Fortunately,
the difference is predictable. Assume a remote-diode
sensor designed for a nominal ideality factor nNOMINAL
is used to measure the temperature of a diode with a
different ideality factor n1. The measured temperature
TM can be corrected using:
______________________________________________________________________________________
13
MAX6693
Table 4. Configuration 1 Register
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
Table 6. Configuration 3 Register
BIT
NAME
POR
STATE
7 (MSB)
Reserved
0
6
Reserved
0
—
FUNCTION
—
5
Mask OVERT 6
0
Channel 6 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 6
OVERT.
4
Mask OVERT 5
0
Channel 5 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 5
OVERT.
3
Mask OVERT 4
0
Channel 4 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 4
OVERT.
2
Reserved
0
—
1
Reserved
0
—
0
Channel 1 Remote-Diode OVERT Mask Bit. Set to logic 1 to mask channel 1
OVERT.
0
Mask OVERT 1
⎛
⎞
n1
TM = TACTUAL ⎜
⎟
⎝ nNOMINAL ⎠
where temperature is measured in Kelvin and
nNOMIMAL for channel 1 of the MAX6693 is 1.009. As
an example, assume you want to use the MAX6693 with
a CPU that has an ideality factor of 1.002. If the diode
has no series resistance, the measured data is related
to the real temperature as follows:
⎛n
⎞
⎛ 1.009 ⎞
TACTUAL = TM × ⎜ NOMINAL ⎟ = TM × ⎜
⎟ = TM (1.00699)
⎝ 1.002 ⎠
n
⎝
⎠
1
For a real temperature of +85°C (358.15K), the measured temperature is +84.41°C (357.56K), an error of
-0.590°C.
Series Resistance Cancellation
Some thermal diodes on high-power ICs can have
excessive series resistance, which can cause temperature measurement errors with conventional remote temperature sensors. Channel 1 of the MAX6693 has a
series resistance cancellation feature (enabled by bit 3
of the configuration 1 register) that eliminates the effect
of diode series resistance. Set bit 3 to 1 if the series
resistance is large enough to affect the accuracy of
channel 1. The series resistance cancellation function
increases the conversion time for channel 1 by 125ms.
This feature cancels the bulk resistance of the sensor
and any other resistance in series (wire, contact resistance, etc.). The cancellation range is from 0Ω to 100Ω.
14
Beta Compensation
The MAX6693 is optimized for use with a substrate PNP
remote-sensing transistor on the die of the target IC.
DXP1 connects to the emitter of the sensing transistor
and DXN1 connects to the base. The collector is
grounded. Such transistors can have very low beta
(less than 1) when built in processes with 65nm and
smaller geometries. Because of the very low beta, standard “remote diode” temperature sensors may exhibit
large errors when used with these transistors. Channel
1 of the MAX6693 incorporates a beta compensation
function that, when enabled, eliminates the effect of low
beta values. This function is enabled at power-up using
bit 2 of the configuration register. Whenever low beta
compensation is enabled, series-resistance cancellation must be enabled.
Discrete Remote Diodes
When the remote-sensing diode is a discrete transistor,
its collector and base must be connected together.
Table 10 lists examples of discrete transistors that are
appropriate for use with the MAX6693. The transistor
must be a small-signal type with a relatively high forward voltage; otherwise, the A/D input voltage range
can be violated. The forward voltage at the highest
expected temperature must be greater than 0.25V at
10µA, and at the lowest expected temperature, the forward voltage must be less than 0.95V at 100µA. Large
power transistors must not be used. Also, ensure that
the base resistance is less than 100Ω. Tight specifications for forward current gain (50 < ß < 150, for example) indicate that the manufacturer has good process
controls and that the devices have consistent VBE char-
______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
BIT
NAME
POR
STATE
7 (MSB)
Reserved
0
—
6
Local ALERT
0
Local Channel High-Alert Bit. This bit is set to logic 1 when the local
temperature exceeds the temperature threshold limit in the local ALERT highlimit register.
5
Remote 6 ALERT
0
Channel 6 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 6 remote-diode temperature exceeds the temperature threshold limit
in the remote 6 ALERT high-limit register.
4
Remote 5 ALERT
0
Channel 5 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 5 remote-diode temperature exceeds the programmed temperature
threshold limit in the remote 5 ALERT high-limit register.
3
Remote 4 ALERT
0
Channel 4 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 4 remote-diode temperature exceeds the temperature threshold limit
in the remote 4 ALERT high-limit register.
2
Remote 3 ALERT
0
Channel 3 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 3 remote-diode temperature exceeds the programmed temperature
threshold limit in the remote 3 ALERT high-limit register.
1
Remote 2 ALERT
0
Channel 2 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 2 remote-diode temperature exceeds the temperature threshold limit
in the remote 2 ALERT high-limit register.
0
Remote 1 ALERT
0
Channel 1 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 1 remote-diode temperature exceeds the temperature threshold limit
in the remote 1 ALERT high-limit register.
FUNCTION
acteristics. Manufacturers of discrete transistors do not
normally specify or guarantee ideality factor. This is
normally not a problem since good-quality discrete
transistors tend to have ideality factors that fall within a
relatively narrow range. We have observed variations in
remote temperature readings of less than ±2°C with a
variety of discrete transistors. Still, it is good design
practice to verify good consistency of temperature
readings with several discrete transistors from any
manufacturer under consideration.
Unused Diode Channels
If one or more of the remote diode channels is not
needed, disconnect the DXP and DXN inputs for that
channel, or connect the DXP input to VCC. The status
register indicates a diode "fault" for this channel and the
channel is ignored during the temperature-measurement sequence. It is also good practice to mask any
unused channels immediately upon power-up by setting the appropriate bits in the Configuration 2 and
Configuration 3 registers. This will prevent unused
channels from causing ALERT or OVERT to assert.
Thermal Mass and Self-Heating
When sensing local temperature, the MAX6693 measures the temperature of the PCB to which it is soldered.
The leads provide a good thermal path between the
PCB traces and the die. As with all IC temperature sensors, thermal conductivity between the die and the
ambient air is poor by comparison, making air temperature measurements impractical. Because the thermal
mass of the PCB is far greater than that of the
MAX6693, the device follows temperature changes on
the PCB with little or no perceivable delay. When measuring the temperature of a CPU or other IC with an onchip sense junction, thermal mass has virtually no
______________________________________________________________________________________
15
MAX6693
Table 7. Status 1 Register
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
Table 8. Status 2 Register
BIT
NAME
POR
STATE
7 (MSB)
Reserved
0
—
6
Reserved
0
—
5
Remote 6 OVERT
0
Channel 6 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 6 remote-diode temperature exceeds the temperature
threshold limit in the remote 6 OVERT high-limit register.
4
Remote 5 OVERT
0
Channel 5 Remote Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 5 remote-diode temperature exceeds the temperature
threshold limit in the remote 5 OVERT high-limit register.
3
Remote 4 OVERT
0
Channel 4 Remote Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 4 remote-diode temperature exceeds the temperature
threshold limit in the remote 4 OVERT high-limit register.
2
Reserved
0
—
1
Reserved
0
—
0
Remote 1 OVERT
0
Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.
FUNCTION
Table 9. Status 3 Register
16
BIT
NAME
POR
STATE
7 (MSB)
Reserved
0
—
6
Diode fault 6
0
Channel 6 Remote-Diode Fault Bit. This bit is set to 1 when DXP6 and DXN6
are open circuit or when DXP6 is connected to VCC.
5
Diode fault 5
0
Channel 5 Remote-Diode Fault Bit. This bit is set to 1 when DXP5 and DXN5
are open circuit or when DXP5 is connected to VCC.
4
Diode fault 4
0
Channel 4 Remote-Diode Fault Bit. This bit is set to 1 when DXP4 and DXN4
are open circuit or when DXP4 is connected to VCC.
3
Diode fault 3
0
Channel 3 Remote-Diode Fault Bit. This bit is set to 1 when DXP3 and DXN3
are open circuit or when DXP3 is connected to VCC.
2
Diode fault 2
0
Channel 2 Remote-Diode Fault Bit. This bit is set to 1 when DXP2 and DXN2
are open circuit or when DXP2 is connected to VCC.
1
Diode fault 1
0
Channel 1 Remote-Diode Fault Bit. This bit is set to 1 when DXP1 and DXN1
are open circuit or when DXP1 is connected to VCC.
0
Reserved
0
—
FUNCTION
______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
Follow these guidelines to reduce the measurement
error when measuring remote temperature:
When measuring temperature with discrete remote transistors, the best thermal response times are obtained
with transistors in small packages (i.e., SOT23 or SC70).
Take care to account for thermal gradients between the
heat source and the sensor, and ensure that stray air
currents across the sensor package do not interfere with
measurement accuracy. Self-heating does not significantly affect measurement accuracy. Remote-sensor
self-heating due to the diode current source is negligible.
1) Place the MAX6693 as close as is practical to the
remote diode. In noisy environments, such as a computer motherboard, this distance can be 4in to 8in
(typ). This length can be increased if the worst noise
sources are avoided. Noise sources include CRTs,
clock generators, memory buses, and PCI buses.
2) Do not route the DXP-DXN lines next to the deflection coils of a CRT. Also, do not route the traces
across fast digital signals, which can easily introduce +30°C error, even with good filtering.
3) Route the DXP and DXN traces in parallel and in close
proximity to each other. Each parallel pair of traces
should go to a remote diode. Route these traces away
from any higher voltage traces, such as +12VDC.
Leakage currents from PCB contamination must be
dealt with carefully since a 20MΩ leakage path from
DXP to ground causes about +1°C error. If high-voltage traces are unavoidable, connect guard traces to
GND on either side of the DXP-DXN traces (Figure 5).
ADC Noise Filtering
The integrating ADC has good noise rejection for lowfrequency signals, such as power-supply hum. In environments with significant high-frequency EMI, connect an
external 100pF capacitor between DXP_ and DXN_.
Larger capacitor values can be used for added filtering,
but do not exceed 100pF because it can introduce errors
due to the rise time of the switched current source. Highfrequency noise reduction is needed for high-accuracy
remote measurements. Noise can be reduced with careful
PCB layout as discussed in the PCB Layout section.
Slave Address
The slave address for the MAX6693 is shown in Table 11.
Table 10. Remote-Sensors Transistor
Manufacturer (for Channels 2–6)
MANUFACTURER
MODEL NO.
Central Semiconductor (USA)
CMPT3904
Rohm Semiconductor (USA)
SST3904
Samsung (Korea)
KST3904-TF
Siemens (Germany)
SMBT3904
Zetex (England)
FMMT3904CT-ND
4) Route through as few vias and crossunders as possible to minimize copper/solder thermocouple effects.
5) Use wide traces when practical. 5mil to 10mil traces
are typical. Be aware of the effect of trace resistance on
temperature readings when using long, narrow traces.
6) When the power supply is noisy, add a resistor (up
to 47Ω) in series with VCC.
GND
5–10 mils
5–10 mils
Note: Discrete transistors must be diode connected (base
shorted to collector).
DXP
MINIMUM
5–10 mils
DXN
PCB Layout
Table 11. Slave Address
5–10 mils
GND
DEVICE ADDRESS
A7
A6
A5
A4
A3
A2
A1
A0
1
0
0
1
1
0
1
R/W
Figure 5. Recommended DXP-DXN PCB Traces. The two outer
guard traces are recommended if high-voltage traces near the
DXN and DXP traces.
______________________________________________________________________________________
17
MAX6693
effect; the measured temperature of the junction tracks
the actual temperature within a conversion cycle.
MAX6693
7-Channel Precision Temperature Monitor
with Beta Compensation
Twisted-Pair and Shielded Cables
Use a twisted-pair cable to connect the remote sensor
for remote-sensor distances longer than 8in or in very
noisy environments. Twisted-pair cable lengths can be
between 6ft and 12ft before noise introduces excessive
errors. For longer distances, the best solution is a
shielded twisted pair like that used for audio microphones. For example, Belden #8451 works well for distances up to 100ft in a noisy environment. At the
device, connect the twisted pair to DXP and DXN and
the shield to GND. Leave the shield unconnected at the
remote sensor. For very long cable runs, the cable’s
parasitic capacitance often provides noise filtering, so
the 100pF capacitor can often be removed or reduced
in value. Cable resistance also affects remote-sensor
accuracy. For every 1Ω of series resistance the error is
approximately +0.5°C.
Pin Configuration
TOP VIEW
+
DXP1 1
20 GND
DXN1 2
19 SMBCLK
DXP2 3
18 SMBDATA
DXN2 4
17 ALERT
DXP3 5
MAX6693
16 VCC
DXN3 6
15 OVERT
DXP4 7
14 N.C.
DXN4 8
13 STBY
DXP5 9
12 DXP6
DXN5 10
11 DXN6
TSSOP
Chip Information
PROCESS: BiCMOS
18
______________________________________________________________________________________
7-Channel Precision Temperature Monitor
with Beta Compensation
PACKAGE TYPE
PACKAGE CODE
DOCUMENT NO.
20 TSSOP
U20-2
21-0066
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 19
© 2008 Maxim Integrated Products
is a registered trademark of Maxim Integrated Products, Inc.
MAX6693