NKK MB2185LD1A

Miniature Pushbuttons
Series MB2000
Distinctive Characteristics
Guide interlocked with actuator block prevents window locking and
maintains correct plunger alignment to assure contact stability.
Employs an over-center actuator mechanism, which diminishes
sparking and increases operating life in AC circuits.
High torque bushing construction prevents rotation
or separation from frame during installation.
Splashproof option (D3 and B3 bushing codes) features an
o-ring within the bushing and one under the face nut
to protect from splashed, sprayed, or spilled liquids.
High insulating barriers, formed in the molded
diallyl phthalate case, increase isolation of circuits
in multipole devices.
Prominent external insulating barriers increase
insulation resistance and dielectric strength.
Epoxy sealed terminals prevent entry of solder
flux and other contaminants.
Clinching of the frame to the case well above the base
and terminals provides 1,500V dielectric strength.
Actual Size
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Miniature Pushbuttons
Series MB2000
General Specifications
Electrical Capacity (Resistive Load)
Power Level (code W):
Logic Level (code G):
Logic/Power Level (code A):
Other Ratings
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Nominal Operating Force:
Contact Timing:
Plunger Travel:
Pretravel:
Overtravel:
Total Travel
Materials & Finishes
Plunger:
Frame:
Movable Contactor:
Movable Contacts:
Stationary Contacts:
Terminals:
Environmental Data
Operating Temp Range:
Humidity:
Vibration:
Shock:
Sealing:
Installation
Mounting Torque:
Cap Installation Force:
Soldering Time & Temp:
Process Seal:
Standards & Certifications
Flammability Standards:
UL & C-UL Recognized:
R
CSA Certified:
6A @ 125V AC & 3A @ 250V AC or 3A @ 30V DC
0.4VA maximum @ 28V AC/DC maximum (Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Combines W & G ratings
Note: Find additional explanation dual rating & operating range in Supplement section.
10 milliohms maximum for silver; 20 milliohms maximum for gold
1,000 megohms minimum @ 500V DC
1,000V AC minimum between contacts for 1 minute minimum;
1,500V AC minimum between contacts & case for 1 minute minimum
50,000 operations minimum for splashproof models; 100,000 for all other models
25,000 operations minimum for silver; 50,000 operations minimum for gold
50,000 operations minimum for silver at 3A @ 125V AC
Momentary Action: 1-pole 9.32N; 2-pole 16.18N; 4-pole 25.54N;
Alternate Action: 1-pole 4.41N; 2-pole 7.06N; 4-pole 11.77N
Slow make, slow break
Screw-on Cap (Mom.)
Screw-on Cap (Alt.)
Snap-on Cap (Mom. & Alt.)
.028” (0.71mm)
.110” (2.80mm)
.125” (3.19mm)
.043” (1.09mm)
.043” (1.10mm)
.050” (1.26mm)
.071” (1.80mm)
.153” (3.90mm)
.175” (4.45mm)
Brass w/nickel plating; polyacetal w/B1 bushing
Bushing:
Brass with nickel plating
Stainless steel
Case:
Diallyl phthalate resin (UL94V-0)
Phosphor bronze with silver or gold plating
Silver alloy (code W); copper with gold plating (code G); or silver alloy with gold plating (code A)
Silver with silver plating (code W); copper or brass with gold plating (code G); or
silver with gold plating (code A)
Copper or brass with silver plating; copper or brass with gold plating
–30°C through +85°C (–22°F through +185°F)
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range
& returning in 1 minute; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
B3 & D3 bushing options equivalent to IP67
1.5Nm (13.0 lb • in) for double nut; .7Nm (6.0 lb • in) for single nut
80.0N (18.0 lbf) maximum downward force on actuator
Wave Soldering (PC version): See Profile A in Supplement section.
Manual Soldering: See Profile A in Supplement section.
These devices are not process sealed. Hand clean locally using alcohol based solution.
UL94V-0 case
All models recognized at 6A @ 125V AC or 3A @ 250V AC or 0.4VA max. @ 28V DC max;
UL File No. WOYR2.E44145; add “/U” to end of part number to order UL mark on switch
C-UL File No. WOYR8.E44145; add “/C-UL” to end of part number to order C-UL mark on switch
All models certified at 6A @ 125V AC or 3A @ 250V AC or 0.4VA max. @ 28V max;
CSA File No. 023535-0-000; add “/C” to end of part number to order CSA mark on switch.
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Bushing Mount Miniature Pushbuttons
Series MB2000
TYPICAL SWITCH ORDERING EXAMPLE
MB
2011
S1
S
SPDT
ON
(ON)
2065
SPDT
ON
ON
2061
DPDT
ON
(ON)
2085
DPDT
ON
ON
2181
4PDT
ON
(ON)
2185
4PDT
ON
ON
01
CONTACT MATERIALS
& RATINGS
POLES & CIRCUITS
2011
W
W
Silver
Rated 6A @ 125V AC
& 3A @ 250V AC
G
Gold
Rated 0.4VA max @
28V AC/DC max
A
Gold over Silver
Rated 6A @ 125V AC
& 0.4VA max @ 28V
AC/DC max
( ) = Momentary
Plunger for Screw-on Caps
L
Plunger for Snap-on Caps
IMPORTANT:
Switches are supplied without UL,
C-UL, & CSA markings unless
specified. Specific models & ratings noted on General Specifications page.
.335” (8.5mm)
Threaded with Keyway
S2
.335” (8.5mm)
Smooth with Keyway
S4
B
.315” (8.0mm) Dia.
C
.394” (10.0mm) Dia.
CAP COLORS
BUSHINGS
S1
A
CAPS
PLUNGER TYPES
S
C
A
Black
B
White
C
Red
E
Yellow
F
Green
G
Blue
H
Gray
TERMINALS
01
Solder Lug
.335” (8.5mm) Metric
Threaded with Keyway
02
Quick Connect
03
.250” (6.35mm) Straight PC
D1
.335” (8.5mm)
Threaded with D-Flat
05
.425” (10.8mm) Wirewrap
06
.750” (19.05mm) Wirewrap
D3
.335” (8.5mm)
Threaded Splashproof
without Keyway
07
.964” (24.5mm) Wirewrap
08
1.062” (27.0mm) Wirewrap
DESCRIPTION FOR TYPICAL ORDERING EXAMPLE
MB2011SS1W01-CA
Black .394” (10.0mm) Diameter Cap
Plunger for Screw-on Caps
.335” (8.5mm) Threaded Bushing with Keyway
SPDT ON-(ON) Circuit
Silver Contacts with 6-Amp Rating
Solder Lug Terminals
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Series MB2000
Bushing Mount Miniature Pushbuttons
POLES & CIRCUITS
Plunger Position
( ) = Momentary
Normal
Pole
Connected Terminals
Down
Normal
Keyway
Model
MB2011
ON
Throw & Switch Schematics
Down
Note: Terminal numbers are
not actually on the switch.
Keyway
(ON)
2 (COM)
SP
MB2065
ON
ON
MB2061
ON
(ON)
ON
ON
MB2181
ON
(ON)
MB2185
ON
ON
2-1
SPDT
2-3 5-6
2-1 5-4
DPDT
3
1
2
DP
MB2085
2-3
3
5
(COM)
1
6
4
4PDT
2-3 5-6
8-9 11-12
4P
2-1 5-4
8-7 11-10
5
2
3
1
6
(COM)
4
11
8
9
7
12
10
PLUNGER TYPES
On alternate action models, after transferring circuit, the plunger returns to its original position and does not latch down.
S
Plunger for Screw-on Caps
(2.9)
.114
(2.9)
.114
(3.0)
.118
Momentary
Plunger Length
L
(2.3)
.091
Momentary
Cap Location
(4.7)
.185
Alternate
Plunger Length
(4.0)
.157
Alternate
Cap Location
Plunger for Snap-on Caps
(3.0) Dia
.118
(10.4)
.410
(3.6)
.142
Momentary & Alternate
Plunger Length
Momentary & Alternate
Cap Location
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Series MB2000
Bushing Mount Miniature Pushbuttons
BUSHINGS
S1
.335” (8.5mm)
Threaded with Keyway
(0.8)
.031
.335” (8.5mm)
Smooth with Keyway
S2
(0.8)
.031
1/4-40 Thd
(9.0) Dia
.354
(8.5)
.335
(8.5)
.335
(3.5)
.138
(2.5)
.098
(8.5)
.335
(3.5)
.138
(3.5)
.138
Maximum Panel Thickness with
Standard Hardware: .154” (3.9mm)
.335” (8.5mm)
Threaded with D Flat
D3
.335” (8.5mm)
Threaded Splashproof without Keyway
1/4-40 Thd
1/4-40 Thd
(9.0) Dia
.354
M6P0.75
(9.0) Dia
.354
(2.5)
.098
Maximum Panel Thickness with
Standard Hardware: .154” (3.9mm)
D1
.335” (8.5mm) Metric
Threaded with Keyway
(0.8)
.031
(6.2) Dia
.244
(9.0) Dia
.354
(2.5)
.098
S4
(10.0) Dia
.394
(2.5)
.098
(8.5)
.335
(8.5)
.335
(3.5)
.138
(3.5)
.138
Maximum Panel Thickness with
Standard Hardware: .240” (6.1mm)
Maximum Panel Thickness with
Standard Hardware: .154” (3.9mm)
Panel Cutouts
For S1, S2, or S4 Bushing
with
Keyway
For S1 or S4 Bushing
with
Optional Locking Ring
(5.6)
.220
(6.5) Dia
.256
(6.5) Dia
.256
(2.2) Dia
.087
(0.6)
.024
(6.5)
.256
For D1 Bushing
with
D Flat
(6.5) Dia
.256
(5.8)
.228
For D3 Bushing
without
Keyway
(6.5) Dia
.256
Standard hardware for bushings S1, S4, & D1 includes 2 hex nuts & 1 lockwasher; D3 bushing has 1 hex nut & 1 o-ring.
Standard & optional hardware are illustrated following the Typical Switch Dimension drawings.
CONTACT MATERIALS & RATINGS
W
Silver over Silver
G
Gold over Brass or Copper
Power Level
6A @ 125V AC & 3A @ 250V AC
Logic Level
0.4VA maximum @ 28V AC/DC maximum
Note: Complete explanation of operating range in Supplement section.
A
Gold over Silver
Power Level
or Logic Level
6A @ 125V AC & 3A @ 250V AC
or 0.4VA maximum @ 28V AC/DC maximum
Note: This dual rated option is suitable when two or more identical switches are used in logic and in power circuits
within the same application. See Supplement section for complete explanation of dual rating and operating range.
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Series MB2000
Bushing Mount Miniature Pushbuttons
TERMINALS
01
.062” (1.57mm) Wide
Quick Connect
02
Solder Lug
(4.0)
.157
Epoxy Seal
(6.35)
.250
Epoxy Seal
(2.0)
.079
(2.0)
(1.1) .079
.043
Thk = (0.8)
.031
03
(1.57)
.062
Thk = (0.8)
.031
.250” (6.35mm)
Straight PC
(4.8)
.189
3
(6.35)
(4.8) .250
.189
Epoxy Seal
2
(4.7) Typ
.185
1
3
6
2
5
1
4
(1.8) Dia Typ
.073
(1.17)
.046
Thk = (0.8)
.031
.425” (10.8mm)
Wirewrap or Extended PC
06
.750” (19.05mm)
Wirewrap or Extended PC
07
.964” (24.5mm)
Wirewrap or Extended PC
08
1.062” (27.0mm)
Wirewrap or Extended PC
6
9
12
2
5
8
11
1
4
7
10
(4.8) Typ
.189
(4.7) Typ
.185
(1.8) Dia Typ
.073
(1.8) Dia Typ
.073
Single Pole
05
(4.7) Typ
.185
3
Double Pole
Four Pole
If using as extended PC terminal, refer to the above footprints.
Epoxy Seal
A
(1.27)
.050
Dimension A = terminal lengths as shown beside the terminal
codes at the left.
Thk = (0.8)
.031
CAPS & CAP COLORS
B
AT413
.315” (8.0mm) Dia.
Screw-on Cap
AT443
.315” (8.0mm) Dia.
Snap-on Cap
C
AT442
.394” (10.0mm) Dia.
Snap-on Cap
AT407
.394” (10.0mm) Dia.
Screw-on Cap
For use with Plunger Code S
For use with Plunger Code L
For use with Plunger Code S
For use with Plunger Code L
Cap Material: PBT
Finish: Glossy
Cap Material: Polycarbonate
Finish: Glossy
Cap Material: PBT
Finish: Glossy
Cap Material: Polycarbonate
Finish: Glossy
(8.0) Dia
.315
Cap Colors
Available:
A
(10.0) Dia
.394
(8.0) Dia
.315
M2.3 P0.4
Black
B
White
C
(8.0)
.315
(8.0)
.315
(7.6)
.299
(6.5)
.256
Red
E
Yellow
(10.0) Dia
.394
M2.3 P0.4
F
Green
G
Blue
H
Gray
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Bushing Mount Miniature Pushbuttons
Series MB2000
TYPICAL SWITCH DIMENSIONS
Solder Lug
Single Pole
(1.1) x (2.0) Typ
.043 x .079
1/4-40 Thd
(0.8) Typ
.031
Keyway
3
(4.7) Typ
.185
(10.0) Dia
.394
(13.0)
.512
2
COM
1
(2.3)
.091
(8.0)
.315
(7.9)
.311
(0.5)
.020
(3.5)
.138
(8.5)
.335
(4.5)
.177
(21.0)
.827
(2.0)
.079
MB2011SS1W01-CA
Solder Lug
Double Pole
1/4-40 Thd
(1.1) x (2.0) Typ
.043 x .079
(0.8) Typ
.031
Keyway
(4.7) Typ
.185
(10.0) Dia
.394
(12.7)
.500
(8.0)
.315
(8.5)
.335
3
5
2
4
1
(0.5)
.020
(3.5)
.138
(2.3)
.091
COM
6
(13.0)
.512
(2.0) Typ
.079
(4.5)
.177
(4.8)
.189
(21.0)
.827
MB2061SS1W01-CA
Solder Lug
Four Pole
1/4-40 Thd
(1.1) x (2.0) Typ
.043 x .079
(0.8) Typ
.031
Keyway
(4.7) Typ
.185
(10.0) Dia
.394
(22.3)
.878
(2.3)
.091
(3.5)
.138
(8.0)
.315
(8.5)
.335
(4.5)
.177
(21.0)
.827
COM
12
9
6
3
11
8
5
2
10
7
4
1
(0.5)
.020
(13.0)
.512
(2.0) Typ
.079
(4.8) Typ
.189
MB2181SS1W01-CA
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Series MB2000
Bushing Mount Miniature Pushbuttons
HARDWARE
Standard Hardware
Optional Hardware
AT513H for Inch
AT513M for Metric
Hexagon Nut
AT509
Lockwasher
AT516
O-ring for
Splashproof Bushing
AT507H for Inch
AT507M for Metric
Locking Ring
2 included with each switch
(1 with splashproof models)
1 included with each switch
(not with splashproof models)
1 included with
each splashproof model
Material:
Steel with Zinc/Chromate
Material:
Brass with Nickel plating
Material:
Steel with Zinc/Chromate
Material:
Nitrile butadiene rubber
(6.0) Dia
.236
M6 P0.75
(8.0)
.315
(12.0) Dia
.472
(2.0)
.079
(6.07) Dia
(9.63) Dia
.239
.379
(6.4) Dia (10.2) Dia
.252
.402
(5.5)
.217
(9.0)
.354
(0.5)
.020
(1.5)
.059
(1.7)
.067
(1.78)
.070
Optional Mounting Collars/Conical Nuts
(0.8)
.031
Optional Splashproof Boots for S Plunger
AT512H for Inch
AT512M for Metric
Conical Nut
AT512CH for Inch
AT512CM for Metric
Conical nut
AT4041H for Inch
AT4041M for Metric
Boot for Momentary
AT4042H for Inch
AT4042M for Metric
Boot for Alternate
Used with .315” (8.0mm) Dia.
Cap (cap code B)
Material:
Brass with chrome plating
Used with .394” (10.0mm)
Dia. Cap (cap code C)
Material:
Brass with chrome plating
Material:
Silicone rubber
Material:
Silicone rubber
M6 P0.75 or
1/4-40 Thd
M2.3 P0.4
A
(13.0) Dia
.512
(10.5) Dia
.413
A
(10.8)
.425
(4.0) Max
.157
(10.0)
.394
(10.8)
.425
(4.9) Dia
.193
(6.0) Dia
.236
(10.0)
.394
(8.5)
.335
(10.0)
.394
(14.0) Dia
.551
(12.2) Dia
.480
(8.5)
.335
(4.0) Max
.157
(10.0)
.394
(4.9) Dia
.193
(6.0) Dia
.236
(8.5)
.335
(4.0) Max
.157
(3.5) Min
.138
Dimension A = Cap Height
Operating Life 100,000
.091” (2.3mm) for Momentary with Plunger Code S
.157” (4.0mm) for Alternate with Plunger Code S
.142” (3.6mm) for Momentary & Alternate with Plunger Code L
Boots for momentary devices
are accompanied by a threaded
adaptor which extends the
length of the plunger.
(10.0)
.394
(4.0) Max
.157
(3.5) Min
.138
Operating Life 30,000
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07