ETC 26PCDFG6G

Pressure Sensors
Gage Unamplified Compensated Flow-Through
26PC Series
FEATURES
1 Measure positive and negative gage
pressures
1 Flow-through port design fits in-line
with application
1 Popular port sizes:
- 8 mm (.315 in.) OD (1/4 in. ID tubing or
standard connectors)
- 0.144 in. OD (1/8 in. ID tubing)
1 Medical grade ISO 10993-1 (USP Class
6) port material
1 Silicon sensor chip
1 24 inch wire harness with splash proof
connector
1 Minimal deadspace — efficient cleansing and disinfecting
Min.
Typ.
Max.
Units
Excitation
---
10
16
VDC
Repeatability & Hysteresis
---
±0.20
---
% Span
Response Time
---
---
1.0
msec
Input Resistance
5.5 K
7.5 K
11.5 K
ohms
Output Resistance
1.5 K
2.5 K
3.0 K
ohms
Stability over One Year
---
±0.5
---
% Span
Weight
---
2
---
grams
Unamplified
26PC SERIES PERFORMANCE CHARACTERISTICS at 10.0 ±0.01 VDC
Excitation, 25°C
Total error calculation, see page 105.
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
−40° to 85°C (−40° to +185°F)
Storage Temperature
−55° to +100°C (−67° to +212°F)
Compensated Temperature
0° to +50°C (32° to +122°F)
Shock
Qualification tested to 150 g
Vibration
MIL-STD-202. Method 213 (150g halfsine,
11 msec)
Media (P1 & P2)
Limited only to those media which will not attack
polyetherimide, silicon, fluorosilicone, silicone,
EPDM, and neoprene seals.
26PC SERIES ORDER GUIDE
Catalog
Listing
Pressure
Range
(psi)
Typ.
Max
Typ.
Max
Min.
Typ.
Max.
Typ.
Max.
Min.
Typ.
26PCA TYPE
1
0.25
0.5
±0.5
±1.0
−1.5
0
+1.5
±1.0
±2.0
14.7
16.7
26PCB TYPE
5
0.4
0.5
±0.5
±1.0
−1.5
0
+1.5
±1.0
±1.5
47
26PCC TYPE
15
0.25
0.5
±0.5
±1.0
−1.5
0
+1.5
±0.75
±1.5
97
Linearity
(% span)
Null Shift
(mV)
Null Offset
(mV)
Span Shift
(% span)
Sensitivity
mV/psi
Overpressure
psi
Max.
Typ.
Max.
18.7
16.7
20
50
53
10.0
20
100
103
6.67
45
Span
(mV)
26PCD TYPE
30
0.1
0.2
±0.75
±1.5
−1.5
0
+1.5
±0.75
±1.5
97
100
103
3.33
60
26PCF TYPE
100
0.1
0.2
±1.0
±2.0
−2.0
0
+2.0
±0.5
±1.5
95
100
105
1.0
200
26PCJ TYPE
38*
0.1
0.5
±0.7
±1.5
−1.5
0
+1.5
±1.0
±1.5
37.5
39.5
41.5
2.63
60
26PCK TYPE
38*
0.1
0.5
±0.7
±1.5
−1.5
0
+1.5
±1.0
±1.5
37.5
39.5
41.5
2.63
60
* Accuracy specifications calculated at 15 psi.
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
23
Pressure Sensors
Gage Unamplified Compensated Flow-Through
26PC Series
SENSOR SELECTION GUIDE
2
Product
Family
2 20PC
Family
6
Circuit
Type
6 Compensated,
Calibrated
PC
Pressure
Transducer
A
Pressure
Range
A 1 psi
B 5 psi
C 15 psi
D 30 psi
F 100 psi
J 38 psi
K 38 psi
(passivated)
F*
Type of
Seal
E EPDM
F Fluorosilicone
N Neoprene
S Silicone
N
Port
Type
G Small
N Large
(.350 dia.)
P Large
(.315 dia.)
5
Termination
Style
G
Pressure
Measurement
2 4-pin DIP
5 Wire
harness
6 4-pin SIP
G Gage
Example: 26PCBFG5G
Compensated, calibrated 5 psi sensor, fluorosilicone seal, small flow-through ports, wire harness, and gage pressure measurements.
*Other media seal materials may be available.
Note: Not all combinations are established. Contact 800 number before final design.
See Accessory Guide, page 27.
24
Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada