MBR10150CTP 10A SCHOTTKY BARRIER RECTIFIER Features Mechanical Data • • • • • • • Low Forward Voltage Drop Soft, Fast Switching Capability Schottly Barrier Chip ITO-220S Heat Sink Tab Electrically Isolated from Cathode UL Approval in Accordance with UL 1557, Reference No. E94661 • • Case: ITO-220S Case Material: Molded Plastic, UL Flammability Classification Rating 94V-0 Terminals: Matte Tin Finish annealed over Copper leadframe. Solderable per MIL-STD-202, Method 208 Weight: 1.335 grams (approximate) 4 Isolated Top View Bottom View 2 Common 1 Cathode 3 Anode Anode Package Pin Out Configuration Ordering Information (Note 1) Part Number MBR10150CTP Notes: Case ITO-220S Packaging 50 pieces/tube 1. For packaging details, go to our website at http://www.diodes.com/datasheets/ap02007.pdf. Marking Information MBR 10150CTP MBR10150CTP = Product Type Marking Code AB = Foundry and Assembly Code YYWW = Date Code Marking YY = Last two digits of year (ex: 08 = 2008) WW = Week (01-53) YYWW AB MBR10150 Document number: DS31499 Rev. 8 - 2 1 of 4 www.diodes.com December 2010 © Diodes Incorporated MBR10150CTP Maximum Ratings (Per Leg) @TA = 25°C unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load. For capacitance load, derate current by 20%. Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage Average Rectified Output Current (Per Leg) (Total) Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load Isolation Voltage From Terminal Heatsink t = 1 min. Symbol VRRM VRWM VRM Value Unit 150 V IO 5 10 A IFSM 105 A VAC 2000 V Symbol RθJC TJ, TSTG Value 3 -65 to +175 Unit °C/W °C Thermal Characteristics (Per Leg) Characteristic Typical Thermal Resistance Junction to Case Operating and Storage Temperature Range Electrical Characteristics (Per Leg) @TA = 25°C unless otherwise specified Characteristic Forward Voltage Drop VF Min - Leakage Current (Note 2) IR - Typ - Max 0.91 0.75 - 0.05 20 Unit V mA Test Condition IF = 5A, TJ = 25ºC IF = 5A, TJ = 125ºC VR = 150V, TJ = 25ºC VR = 150V, TJ = 125ºC 2. Short duration pulse test used to minimize self-heating effect. 100 IR, INSTANTANEOUS REVERSE CURRENT (µA) IF, INSTANTANEOUS FORWARD CURRENT (A) Notes: Symbol 10 1 TA = 150°C TA = 125°C 0.1 T A = 85°C 0.01 TA = 25°C 0.001 0.0001 1,000 0 200 400 600 800 1,000 1,200 VF, INSTANTANEOUS FORWARD VOLTAGE (mV) Fig. 1 Typical Forward Characteristics MBR10150 Document number: DS31499 Rev. 8 - 2 2 of 4 www.diodes.com T A = 150°C 100 TA = 125°C 10 TA = 85°C 1 TA = 25°C 0.1 0.01 0 30 60 90 120 150 VR, INSTANTANEOUS REVERSE VOLTAGE (V) Fig. 2 Typical Reverse Characteristics December 2010 © Diodes Incorporated MBR10150CTP IF(AV), AVERAGE FORWARD CURRENT (A) 10 RθJA = RθJC Total Device 5 RθJA = 21°C/W Per Element 0 25 50 75 100 125 TA, AMBIENT TEMPERATURE (°C) Fig. 3 Forward Current Derating Curve 150 Package Outline Dimensions ITO-220S A E Q DIM. A1 + 7 ° Ref H1 + ØP D Ø1.5 Dp 0.1 max D1 D2 1.7 Ref 5° Ref E1 5° Ref A2 L1 b2 L e 5 ° Ref MBR10150 Document number: DS31499 Rev. 8 - 2 b c e1 5 ° Ref 3 of 4 www.diodes.com MIN. MAX. TYP. A 4.52 4.62 4.57 A1 1.17 1.39 − A2 2.57 2.77 2.67 b 0.72 0.95 0.84 b2 1.15 1.34 1.26 c 0.356 0.61 − D 14.22 16.51 15.00 D1 8.60 8.80 8.70 D2 13.68 14.08 − e 2.49 2.59 2.54 e1 4.98 5.18 5.08 E 10.01 10.21 10.11 E1 6.86 8.89 − H1 5.85 6.85 − L 13.30 13.90 13.60 L1 4.00 − − P 3.54 4.08 − Q 2.54 3.42 − All Dimensions in mm December 2010 © Diodes Incorporated MBR10150CTP IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2010, Diodes Incorporated www.diodes.com MBR10150 Document number: DS31499 Rev. 8 - 2 4 of 4 www.diodes.com December 2010 © Diodes Incorporated