MF-0637A-50BL Operating Voltage = 48 Vdc Operating Current = 50 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min LINE LOAD Safety Agency Approval = TUV, CSA (Canada Y US) Order P/N: MM-0637A -50BL Ø0.62 (4x) 3.10 4.50 ±0.25 1.55 1.25 0.42 (RTN) BLACK NEGRO AWG #12 BLACK 1.40 2.74 3.05 2.25 RED ROJO (-48V) AWG #12 RED 0.36 0.625 Ø0.22 (2X) 0.60 INSERTION LOSS vs. FREQUENCY MF-0637A-50BL or BR SERIES 70 INSERTION LOSS (db) 60 50 DM 40 CM 30 20 10 0 .01 .04 .02 .1 .07 .4 .2 1 4 10 .7 2 7 20 FREQUENCY (MEGAHERTZ) 40 100 This EMI / RFI filter features a very small mechanical package. Even with this small size the common mode insertion loss and differential loss more than is available in other similarly sized packages. This filter has additionally been designed to operate with severe unbalanced current loading. It can withstand up to a 30% unbalance in line and return without degrading the common mode insertion loss. This capability is very useful when the filter is used in dual systems with shared returns. This filter package is ruggedly designed to operate in automotive as well as telecommunication environments. 70 USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884