Description. Conductor insulation: special PVC. Conductors with bigger section for power
and earth + reduced section for signals. Internal sheath: special PVC. Outer sheath of matt
polyether polyurethane (PUR).
Application. In the distribution boxes, when the common wires carry much more current with
respect to the signal wires. The internal PVC sheath makes for easier cable working with
respect to the correspondent types entirely made of PUR. Very good resistance to common
chemical agents and oils (UL 1581). Good abrasion resistance. The cables with class 6
conductors have a good behaviour in mobile laying.
Max working voltage: 300 V. Test voltage: 2000 V.
Descrizione. Isolante conduttori in PVC speciale. Conduttori con sezioni più grandi per
potenza e terra + sezioni ridotte per segnali. Guaina interna: PVC speciale. Guaina esterna in
poliuretano (PUR) polietere opaco.
Impiego. Nelle scatole di distribuzione, quando i fili comuni portano molta più corrente rispetto
ai fili di segnale. La guaina interna in PVC facilita la lavorazione rispetto ai tipi corrispondenti
costruiti in solo poliuretano. Ottima resistenza agli agenti chimici e agli idrocarburi comuni
(UL1581). Buona resistenza all’abrasione. I cavi con conduttori in classe 6 hanno un buon
comportamento in posa mobile.
Tensione massima di lavoro: 300 V. Tensione di prova: 2000 V.
Note to table:
(a) example: 3 = three wires; 2+1 = two wires + yellow/green earth.
(b) colours: C = according to IEC 60304 (former DIN 47100), see section “General Information”.
(c) norms: UL = UL recognized (United States) / CSA = CSA recognized (Canada).
Note alla tabella:
(a) esempio: 3 = tre conduttori; 2+1 = due conduttori + terra giallo/verde.
(b) colori: C = secondo IEC 60304 (ex DIN 47100), vedere sezione “Informazioni Generali”.
(c) norme: UL = certificato UL (Stati Uniti) / CSA = certificato CSA (Canada).
Formation
Formazione
Descriptive code
Codice descrittivo
Short
code
Codice
breve
1,00
0,75
n x mm2 (a)
(2+1)x0,75 + 8x0,34
(2+1)x0,75 + 12x0,34
(2+1)x0,75 + 16x0,34
(2+1)x1,00 + 8x0,50
(2+1)x1,00 + 12x0,50
(2+1)x1,00 + 16x0,50
MH-PF9
MH-PF95-11LC5
MH-PF95-15LC5
MH-PF95-19LC5
MH-PF96-11LC5
MH-PF96-15LC5
MH-PF96-19LC5
843
844
845
873
874
875
Refer. or style
Rifer. o style
Sheath colour
Colore guaina
Wires
colour
Colore
cond.
Copper
class
Classe
rame
Static
application
Applicazione
statica
Dynamic
application
Applicazione
dinamica
(c)
RAL
(b)
IEC 60228
°C
°C
-25...+ 80
-25...+ 80
-25...+ 80
-25...+ 80
-25...+ 80
-25...+ 80
-15...+ 80
-15...+ 80
-15...+ 80
-15...+ 80
-15...+ 80
-15...+ 80
300V 80°C UL-CSA
300V 80°C UL-CSA
300V 80°C UL-CSA
300V 80°C UL-CSA
300V 80°C UL-CSA
300V 80°C UL-CSA
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
C
C
C
C
C
C
6
6
6
6
6
6
Note Nota
Multi-section cables, CEI 20-22 II,
PVC
Cavi multisezione, CEI 20-22 II,
PVC
Description. Conductor insulation: special PVC. Conductors with bigger section for power and
earth + reduced section for signals. Outer sheath: special PVC.
Application. In the distribution boxes, when the common wires carry much more current with
respect to the signal wires. Moderate resistance to common oils (UL 1581). Flame resistance
grade: CEI 20-22 II and IEC 60332-3A. The cables with class 6 conductors have a good
behaviour in mobile laying. Limited resistance to abrasion.
Max working voltage: 300 V. Test voltage: 2000 V over.
Descrizione. Isolante conduttori in PVC speciale. Conduttori con sezioni più grandi per potenza
e terra + sezioni ridotte per segnali. Guaina esterna: PVC speciale.
Impiego. Nelle scatole di distribuzione, quando i fili comuni portano molta più corrente rispetto
ai fili di segnale. Moderata resistenza agli oli comuni. Resistenza alla fiamma: CEI 20-22 II e
IEC 60332-3A. I cavi con rame classe 6 sono anche progettati per l’uso in posa mobile. Limitata
resistenza all’abrasione.
Tensione massima di lavoro: 300 V. Tensione di prova: 2000 V.
Note to table:
(a) example: 3 = three wires; 2+1 = two wires + yellow/green earth.
(b) colours: C = according to IEC 60304 (former DIN 47100), see section “General Information”.
(c) norms: UL = UL recognized (United States) / CSA = CSA recognized (Canada).
Note alla tabella:
(a) esempio: 3 = tre conduttori; 2+1 = due conduttori + terra giallo/verde.
(b) colori: C = secondo IEC 60304 (ex DIN 47100), vedere sezione “Informazioni Generali”.
(c) norme: UL = certificato UL (Stati Uniti) / CSA = certificato CSA (Canada).
Formation
Formazione
Descriptive code
Codice descrittivo
Short
code
Codice
breve
1,00
0,75
n x mm2 (a)
(2+1)x0,75 + 8x0,34
(2+1)x0,75 + 12x0,34
(2+1)x0,75 + 16x0,34
(2+1)x1,00 + 8x0,50
(2+1)x1,00 + 12x0,50
(2+1)x1,00 + 16x0,50
33 MH-P
MH-PN7
MH-PN75-11LC5
MH-PN75-15LC5
MH-PN75-19LC5
MH-PN76-11LC5
MH-PN76-15LC5
MH-PN76-19LC5
823
824
825
853
854
855
Refer. or style
Rifer. o style
Sheath colour
Colore guaina
Wires
colour
Colore
cond.
Copper
class
Classe
rame
Static
application
Applicazione
statica
Dynamic
application
Applicazione
dinamica
(c)
RAL
(b)
IEC 60228
°C
°C
60332-3A IEC
60332-3A IEC
60332-3A IEC
60332-3A IEC
60332-3A IEC
60332-3A IEC
gy 7035
gy 7035
gy 7035
gy 7035
gy 7035
gy 7035
www.shield.net
C
C
C
C
C
C
5
5
5
5
5
5
-15...+ 70
-15...+ 70
-15...+ 70
-15...+ 70
-15...+ 70
-15...+ 70
Note Nota
Similar pages