Honeywell ML001BG1PG High value and outstanding performance no internal elastomeric seal Datasheet

APPLICATIONS
MODEL ML •
•
DIESEL ENGINES
•
REFRIGERATION AND
HVAC SYSTEMS
•
HYDRAULIC FLUID
PRESSURES
•
GENERAL
INDUSTRIAL
PRESSURE
•
OFF ROAD
VEHICLES
OEM PRESSURE TRANSDUCER
FEATURES
High value and outstanding performance
No internal elastomeric seals
Amplified outputs
Reverse polarity protection
Less than 500 microseconds response time
Designed to meet IP65 standards*
Exceeds CE Heavy Industrial EMC
•
•
•
•
•
•
Excellent OEM value
Eliminates O-Ring compatability issues
Eliminates cost of external amplifiers
Not damaged by reversed excitation
Accurate high speed measurements
Protected from harsh environments
* With appropriate mating connector, Packard #12065287.
HOW TO ORDER
ML
100
Model
Range
15
25
50
100
200
300
500
PSI
01K
02K
03K
05K
001
004
006
010
016
025
040
060
100
160
250
350
P
S
1
P
G
Output
C = 0.5-4.5 VDC
G = 4-20 mA
R5 = 1-6 VDC
Termination
P = Packard
Pressure Connection
BAR
1 = 1/8-27 NPT
2 = 1/4-18 NPT
Unit
P = PSI
B = BAR
Reference
G = Gage (only on < 100 PSI)
S = Sealed
Note: Not all combinations are available. Minimum quantity orders apply. Contact the factory for more details.
PRESSURE TRANSDUCER
•
•
•
•
•
•
•
BENEFITS
ML SERIES
The model ML pressure transducer combines
the latest in ASIC technology with our proven
stainless steel design. This digitally compensated
transducer offers an unparalleled value and
performance combination making it the ideal
pressure sensing solution for demanding
automotive and industrial applications. Fully
temperature compensated, calibrated, and
amplified, the ML is available in 100 to 5000
PSIS pressure ranges.
The ML has three standard output options:
a 0.50 to 4.50 Vdc ratiometric output from
5 Vdc excitation, a 1.0 to 6.0 Vdc regulated output from 7-35 Vdc excitation, and a 4-20 mA
current from 9-35 Vdc excitation. The ML
transducer delivers ±0.25% full scale accuracy
(BFSL) over a wide temperature range of -40°C
to 105°C and utilizes a proven industry standard
connector for high reliability and user flexibility.
ML SERIES
•
PRESSURE TRANSDUCER
TECHNICAL SPECIFICATIONS
DIMENSIONS
RANGES
15, 25, 50 PSIG; 100, 200, 300, 500, 1000, 2000, 3000, 5000 PSIS
6, 10, 16, 25, 40, 60, 100,160, 250 BAR
xx.xx = inches
(xx.x) = mm
PHYSICAL
Proof Pressure
< 500 psi
2 X rated range
≥ 500 psi
1.5 X rated range
Burst Pressure
< 500 psi
10 X rated range
≥ 500 psi (30K psi max)
10 X rated range
Material in Contact
with Media
300 series SS,
braze compound
Weight
1.58
[40] *
0.73
[19]
Not Intended for
Customer use
0.60
[15] **
0.85
[22]
c
1.06
[27]
2.0 oz (57 gm)
ENVIRONMENTAL
Shock
50 g’s peak (5 ms), 100 g’s peak (11 ms)
Vibration
Figure 514.2-5, Curve AK, Table 514.2-V
Random Vibration Test (Overall g rms = 20.7 minimum)
ELECTRICAL
Ratiometric Voltage Regulated
Zero Output
Current
0.5 Vdc
1.0 Vdc
4.0 mA
Full Scale Output*
4.0 Vdc
(0.50-4.50 Vdc)
5.0 Vdc
(1.0-6.0 Vdc)
16 mA
(4-20 mA)
Excitation
5 Vdc ±250 mV
(7.0 V max)
7-35 Vdc
9.5-35 Vdc
5 mA typical
(7 mA max)
5 mA typical
(7 mA max)
N/A
Supply Current
Source (nominal)
Sink (nominal)
2.0 mA
2.0 mA
N/A
20 µA
@ zero output
20 µA
@ zero output
N/A
90 db
90 db
25 W max.
N/A
25 W max.
a
1-1/16 [27] HEX
* Maximum
** 0.75 [19] for 1/4-18 NPT
1/8-27 NPT or 1/4-18 NPT
PIN AND WIRE CODES
Supply Rejection Ratio 90 db
Output Impedance
b
Pins
Voltage
Current
A
+ Excitation
+ Excitation
B
Output
- Excitation
C
Common
NC
PERFORMANCE
Response Time
EMI/RFI
Exceeds CE heavy industrial (30v/m radiated 150kHz-1gHz)
Electrical
Connection
Accuracy
< 500 microseconds
Packard Metri-Pack™ connector requires
Packard #12065287 mating connector
±0.25% F.S.O. best fit straight line.
Includes: non-linearity, hysteresis, non-repeatability.
Thermal errors not included. 0.5% < 100 PSI **
Total Error Band
±2% Typical (±3% Max.) F.S.O.
Includes: zero offset error, span error, thermal effect on zero
and thermal effect on span, non-linearity, hysteresis, non-repeatability
Compensated Operating and
Storage Temperature Range
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
-40° to 105°C
(-40° to 221°F)
* PSIG vented thru vent hole protected by Gortex® filter
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
NOTE: All specifications are measured at 25° C (77° F) and at rated excitation unless
otherwise specified.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
NOTE: Meets IEC-68-2 or MIL-STD 810C.
NOTE: Contact the factory to discuss other pressure ranges.
Item # 1121700 M.G. 3/01 Rev. A
Sensing and Control
Honeywell
100 Discovery Way
Acton, MA 01720 USA
Tel: (877) 384-1300; Fax: (978) 263-0630
www.honeywell.com/sensing/
Similar pages