WJ ML401 1.7-2.2 ghz high ip3 mixer with integrated lo amp Datasheet

ML401
The Communications Edge TM
1.7–2.2 GHz High IP3 Mixer with Integrated LO Amp
Product Features
Product Information
Product Description
Functional Diagram
• High dynamic range mixer with
integrated LO driver
• +31 dBm Input IP3
• 8 dB Conversion Loss
• RF: 1700 – 2200 MHz
• LO: 1550 – 2150 MHz
• IF: 50 – 250 MHz
• 0 dBm Drive Level
• RoHS-compliant SOIC-8 pkg
The ML401 high linearity upconverter or downconverter
combines a passive GaAs MESFET mixer with an
integrated HBT LO driver in a low-cost leadfree/green/RoHS-compliant SOIC-8 package.
WJ’s
ML401 uses patented techniques to realize +31 dBm Input
IP3 with 8 dB conversion loss using an LO drive level of 0
dBm in a downconverting application. The on-chip
diplexer in the mixers allows for good matching on the RF
and IF ports. The dual-stage LO driver provides a stable
input power level into the mixer to allow for consistent
performance over a wide range of LO power levels.
Applications
Typical applications include frequency up/down
conversion, modulation and demodulation for receivers and
transmitters used in 2.5G and 3G GSM/CDMA/W-CDMA
systems in the DCS, PCS, or UMTS frequency bands.
• 2.5/3G GSM/CDMA/WCDMA
• DCS/PCS-band Mobile
Infrastructure
LO
1
8 RF
GND
2
7 GND
Vcc1
3
6 GND
Vcc2
4
5 IF
The backside paddle is Ground.
Specifications (1)
Parameter
RF Frequency Range
LO Frequency Range
IF Frequency Range
SSB Conversion Loss
Input IP3 (2)
Input P1dB
LO – RF Isolation (3)
LO – IF Isolation (3)
RF – IF Isolation
Return Loss: RF Port
Return Loss: IF Port
Return Loss: LO Port
LO Drive Level
Operating Supply Voltage
Operating Current (4)
1.
2.
3.
4.
Units
MHz
MHz
MHz
dB
dBm
dBm
dB
dB
dB
dB
dB
dB
dBm
V
mA
Min
-2.5
Typ
1700 – 1800
1550 – 1750
50 – 150
8.2
+31
+17
9
27
19
16
25
15
0
+5
102
Max
Min
+28
2.5
-2.5
85
Typ
1800 – 2000
1600 – 1950
50 – 250
8.2
+30
+19
8
27
20
16
25
15
0
+5
105
Max
Min
9
2.5
135
-2.5
Typ
2000 – 2200
1750 – 2150
50 – 250
8.2
+30
+20
8
27
21
16
25
15
0
+5
110
Max
2.5
Min / max limits are tested for the mixer in downconverting application with a low-side LO at 0 dBm at 25 °C with RF/IF = 1800/50, 2000/50, and 1800/200 MHz.
IIP3 is measured with Δf = 1 MHz with RFin = 0 dBm / tone.
LO is injected with 0 dBm.
This refers to the operating current under LO drive. The current can be reduced by increasing the value of the R2 resistor slightly.
Absolute Maximum Rating
Parameter
Operating Case Temperature
Storage Temperature
DC Voltage
LO Power
Input IF / RF Power
Rating
-40 to +85 °C
-55 to +150 °C
+5.5 V
+10 dBm
+20 dBm
Ordering Information
Part No.
Description
ML401-G
1.7–2.2 GHz High IP3 Mixer w/ Integrated LO Amp
ML401-PCB
Full Assembled Evaluation Board
(lead-free/green/RoHS-compliant SOIC-8 package)
Operation of this device above any of these parameters may cause permanent damage.
Specifications and information are subject to change without notice
WJ Communications, Inc • Phone 1-800-WJ1-4401 • FAX: 408-577-6621 • e-mail: [email protected] • Web site: www.wj.com
Page 1 of 4 June 2006
ML401
The Communications Edge TM
1.7–2.2 GHz High IP3 Mixer with Integrated LO Amp
Product Information
Typical Downconversion Performance Plots
Performance using the circuitry on the ML401-PCB Evaluation Board
R1 is shown in the silkscreen but is not required for the ML401. A 0Ω jumper is placed in this spot on the PCB.
Conversion Loss vs RF Frequency vs IF Frequency
Input IP3 vs RF Frequency vs IF Frequency
+25 °C, LO = 0 dBm, low-side LO
+25 °C, LO = 0 dBm, low-side LO
9
32
Input IP3 (dBm)
34
Conversion Loss (dB)
10
8
7
IF=50MHz
IF=150MHz
IF=250MHz
6
5
1700
1750
1800
1850
IF=100MHz
IF=200MHz
1900
1950
2000
30
28
IF=50MHz
IF=150MHz
IF=250MHz
26
24
1700
1750
1800
RF Frequency (MHz)
Conversion Loss vs RF Frequency vs Temperature
8
7
6
1750
1800
1850
+25 °C
1900
+85 °C
1950
8
7
6
-40 °C
2000
1750
RF Frequency (MHz)
Conversion Loss vs RF Frequency vs LO Power
1850
1900
+85 °C
1950
2000
1800
1850
1900
RF Frequency (MHz)
-40 °C
1750
1950
2000
1850
1900
+85 °C
1950
2000
Conversion Loss vs RF Frequency vs LO Power
+25 °C, IF = 250 MHz, low-side LO
10
9
8
7
LO = -3
dBm
LO = 0
dBm
LO = 3
6
5
1700
1800
+25 °C
RF Frequency (MHz)
Conversion Loss (dB)
LO = -3 dBm
LO = 0 dBm
LO = 3 dBm
Conversion Loss (dB)
8
1750
6
+25 °C, IF = 150 MHz, low-side LO
9
6
7
5
1700
10
7
8
Conversion Loss vs RF Frequency vs LO Power
+25 °C, IF = 50 MHz, low-side LO
Conversion Loss (dB)
1800
+25 °C
9
RF Frequency (MHz)
10
5
1700
LO = 0 dBm, IF = 250 MHz, low-side LO
9
5
1700
2000
10
Conversion Loss (dB)
9
Conversion Loss (dB)
Conversion Loss (dB)
10
1950
Conversion Loss vs RF Frequency vs Temperature
LO = 0 dBm, IF = 150 MHz, low-side LO
10
-40 °C
1900
RF Frequency (MHz)
Conversion Loss vs RF Frequency vs Temperature
LO = 0 dBm, IF = 50 MHz, low-side LO
5
1700
1850
IF=100MHz
IF=200MHz
1750
1800
1850
1900
1950
2000
9
8
7
LO = -3 dBm
LO = 0 dBm
LO = 3 dBm
6
5
1700
1750
1800
1850
1900
1950
2000
RF Frequency (MHz)
RF Frequency (MHz)
Specifications and information are subject to change without notice
WJ Communications, Inc • Phone 1-800-WJ1-4401 • FAX: 408-577-6621 • e-mail: [email protected] • Web site: www.wj.com
Page 2 of 4 June 2006
ML401
The Communications Edge TM
1.7–2.2 GHz High IP3 Mixer with Integrated LO Amp
Product Information
Typical Downconversion Performance Plots (cont’d)
Performance using the circuitry on the ML401-PCB Evaluation Board
Input IP3 vs RF Frequency vs Temperature
Input IP3 vs RF Frequency vs Temperature
32
30
28
26
1800
1850
1900
30
28
26
+85 °C
1950
-40 °C
24
1700
2000
1750
1800
+25 °C
1850
1900
30
28
26
+85 °C
1950
-40 °C
24
1700
2000
1900
1950
Input IP3 vs RF Frequency vs LO Power
Input IP3 vs RF Frequency vs LO Power
Input IP3 vs RF Frequency vs LO Power
+25 °C, IF = 50 MHz, low-side LO
+25 °C, IF = 150 MHz, low-side LO
32
32
28
LO = -3 dBm
LO = 0 dBm
LO = 3 dBm
26
1750
1800
1850
1900
1950
30
28
LO = -3 dBm
LO = 0 dBm
LO = 3 dBm
26
24
1700
2000
1750
RF Frequency (MHz)
1800
1850
1900
RF Return Loss vs LO Frequency
24
1700
2000
IF Return Loss (dB)
IF = 50 MHz
IF = 150 MHz
IF = 250 MHz
-15
-20
1850
1900
1950
-20
100
150
200
1700
1800
1900
2000
LO Frequency (MHz)
R-I Isolation vs LO Frequency
25
10
5
R-I Isolation (dB)
L-I Isolation (dB)
15
1900
-20
Referenced with LO = 0 dBm
20
1800
-15
-25
1600
250
35
+25 °C
2000
-10
L-I Isolation vs LO Frequency
Referenced with LO = 0 dBm
1950
-5
IF Frequency (MHz)
L-R Isolation vs LO Frequency
1900
+25 °C
-40
50
1850
LO Return Loss vs LO Frequency
-30
2000
25
1700
1800
0
LO = 1550 MHz
LO = 1650 MHz
LO = 1750 MHz
LO = 1850 MHz
-10
RF Frequency (MHz)
-40 °C
1750
RF Frequency (MHz)
-50
1800
LO = -3 dBm
LO = 0 dBm
LO = 3 dBm
26
+25 °C, LO = 0 dBm
0
1750
28
IF Return Loss vs IF Frequency
+25 °C, LO = 0 dBm
-10
1950
30
RF Frequency (MHz)
0
-5
Input IP3 (dBm)
32
30
2000
+25 °C, IF = 250 MHz, low-side LO
34
0
1600
1850
RF Frequency (MHz)
34
-25
1700
1800
+85 °C
RF Frequency (MHz)
34
24
1700
1750
+25 °C
RF Frequency (MHz)
LO Return Loss (dB)
Input IP3 (dBm)
1750
+25 °C
Input IP3 (dBm)
32
Input IP3 (dBm)
32
24
1700
RF Return Loss (dB)
LO = 0 dBm, IF = 250 MHz, low-side LO
34
-40 °C
L-R Isolation (dB)
Input IP3 vs RF Frequency vs Temperature
LO = 0 dBm, IF = 150 MHz, low-side LO
34
Input IP3 (dBm)
Input IP3 (dBm)
LO = 0 dBm, IF = 50 MHz, low-side LO
34
30
25
20
15
+85 °C
-40 °C
10
1600
2000
1700
LO Frequency (MHz)
+25 °C
1800
20
15
10
5
-40 °C
+85 °C
1900
2000
0
1800
1850
1900
1950
+25 °C
2000
+85 °C
2050
2100
LO Frequency (MHz)
LO Frequency (MHz)
Input P1dB vs RF Frequency
IF = 100 MHz, low-side LO at 0 dBm
Input P1dB (dBm)
22
20
18
16
14
-40 °C
12
1700
1750
1800
+25 °C
1850
+85 °C
1900
1950
2000
RF Frequency (MHz)
Specifications and information are subject to change without notice
WJ Communications, Inc • Phone 1-800-WJ1-4401 • FAX: 408-577-6621 • e-mail: [email protected] • Web site: www.wj.com
Page 3 of 4 June 2006
ML401
The Communications Edge TM
1.7–2.2 GHz High IP3 Mixer with Integrated LO Amp
Product Information
ML401-G Mechanical Information
This package is lead-free/green/RoHS-compliant. The plating material on the leads is NiPdAu. It is compatible with both lead-free
(maximum 260 °C reflow temperature) and lead (maximum 245 °C reflow temperature) soldering processes.
Product Marking
Outline Drawing
The component will be lasermarked with a
“ML401-G”
product
label
with
an
alphanumeric lot code on the top surface of the
package.
Tape and reel specifications for this part will be
located on the website in the “Application
Notes” section.
ESD / MSL Information
ESD Rating:
Value:
Test:
Standard:
Class 1B
Passes 500V to <1000V
Human Body Model (HBM)
JEDEC Standard JESD22-A114
ESD Rating:
Value:
Test:
Standard:
Class IV
Passes 1000V
Charged Device Model (CDM)
JEDEC Standard JESD22-C101
MSL Rating: Level 2 at +260 °C convection reflow
Standard:
JEDEC Standard J-STD-020
Functional Pin Layout
Mounting Configuration / Land Pattern
LO
1
8 RF
GND
2
7 GND
Vcc1
3
6 GND
Vcc2
4
5 IF
The backside paddle is Ground.
Pin
1
2
3
4
5
6
7
8
1. Ground / thermal vias are critical for the proper performance of this device. Vias should use a .35mm (#80 / .0135”) diameter drill
and have a final plated thru diameter of .25 mm (.010”).
2. Add as much copper as possible to inner and outer layers near the part to ensure optimal thermal performance.
3. Mounting screws can be added near the part to fasten the board to a heatsink. Ensure that the ground / thermal via region contacts the
heatsink.
4. All dimensions are in millimeters (inches). Angles are in degrees.
5. Do not put solder mask on the backside of the PC board in the region where the board contacts the heatsink.
6. RF trace width depends upon the PC board material and construction.
7. Use 1 oz. Copper minimum.
Function
LO
GND
Vcc1
Vcc2
IF
GND
GND
RF
Backside paddle is RF and DC ground.
Thermal Specifications
Parameter
Rating
Operating Case Temperature
Thermal Resistance, Rth
-40 to +85 °C
104 °C / W
Specifications and information are subject to change without notice
WJ Communications, Inc • Phone 1-800-WJ1-4401 • FAX: 408-577-6621 • e-mail: [email protected] • Web site: www.wj.com
Page 4 of 4 June 2006
Similar pages