Power-One MPB125-2048 High power density in industry standard 3 x 5 footprint Datasheet

MPB125 SERIES
DESCRIPTION
The MPB125 series incorporates patented high efficiency circuitry,
high power density and active Power Factor Correction (PFC) to meet
the requirements of networking and data communications systems, as
well as commercial and industrial configurations.
Advanced Produc
t
Release
output power is available with as few as 130 Linear Feet per Minute
(LFM) forced-air cooling.
The MPB125 product line is approved to the latest international
regulatory standards, and displays the CE Mark.
Dual output units deliver a regulated main output plus a second 12V
output for fans or other system functions. Multiple output models
provide tightly regulated DC power in a variety of configurations.
The MPB125 is rated for convection as well as forced-air cooling. Full
FEATURES
•
•
•
•
•
•
High Power Density in Industry Standard 3" x 5" Footprint
Power Factor Correction (PFC) Meets EN61000-3-2
Main Output Remote Sense
Power Good Signals
CE Marked to Low Voltage Directive
Input Transient & ESD Compliance to
EN61000-4-2/-3/-4/-5
MULTIPLE OUTPUT MODEL SELECTION CHART 80 Watts Convection Cooling, 125 Watts Forced-Air Cooling
OUTPUT
VOLTAGE
(VOLTS)
MODEL
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM (NOTE 2)
TOTAL
REGULATION
%
+5V
25A
±3%
+12V
0.5A
±5%
+12V
10.5A
±3%
MPB125-2012
+12V
0.5A
±5%
+15V
8.3A
±3%
MPB125-2015
+12V
0.5A
±5%
+24V
5.2A
±3%
MPB125-2024
+12V
0.5A
±5%
+48V
2.6A
±3%
MPB125-2048
+12V
0.5A
±5%
+5V
15A
±3%
MPB125-3000
+12V
5A
±5%
-12V
0.5A
±3%
+2.5V
10A (NOTE 4,5)
±3%
+5V
15A (NOTE 4,5)
±3%
MPB125-4250
+12V
5A
±5%
(NOTE 1)
-12V
0.5A
±3%
+3.3V
10A (NOTE 4,5)
±3%
+5V
15A (NOTE 4,5)
±3%
MPB125-4350
+12V
5A
±5%
(NOTE 1)
-12V
0.5A
±3%
NOTES: 1) Maximum convection output power is 75 watts.
2) Maximum forced-air output power is 125 watts with 130 LFM at 5 CFM.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) Maximum power of 80 watts from V1 + V2 with 130 LFM at 5 CFM forced-air cooling.
5) Maximum power of 45 watts from V1 + V2 for convection cooling.
MPB125-2005
RIPPLE & NOISE
% pk-pk
(NOTE 3)
REGULATION RANGE
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
4.85V to 5.15V
11.40V to 12.60V
11.64V to 12.36V
11.40V to 12.60V
14.54V to 15.45V
11.40V to 12.60V
23.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
4.85V to 5.15V
11.40V to 12.60V
-11.64V to -12.36V
2.42V to 2.58V
4.85V to 5.15V
11.40V to 12.60V
-11.64V to -12.36V
3.20V to 3.40V
4.85V to 5.15V
11.40V to 12.60V
-11.64V to -12.36V
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. 08/23/01
1
MPB125 SERIES
Advanced Produc
t
Release
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage- AC
Input Frequency
Brownout Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
90 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, 3.15A.
Internally limited by thermistor,
110VAC:
one cycle, 25° C.
220VAC:
Active PFC meets requirements of EN61000-3-2.
Switching frequency of main transformer.
90
47
90
17
Power Factor Circuitry
Operating Frequency
NOM
MAX
UNITS
264
63
VAC
Hz
VAC
mS
ARMS
1.8
23
46
100
APK
kHz
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Full Load, 230VAC. Varies with distribution of loads among outputs.
V1 + V2 + V3.
Full load, 20 MHz bandwidth.
130 LFM at 5 CFM forced-air cooling.
Convection, dual and triple-output models.
Convection, four-output models.
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes from 85-132 VAC
or 170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Maximum deviation due to a 25% load change with unit at 75% load.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
75
85
5
See Model Selection Chart
125
80
75
10
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
NOM
MAX
UNITS
%
Watts
Watts
%
See Model Selection Chart
3
1.5
20
%
Sec
mS
MAX
UNITS
3.20
3.67
5.74
13.5
17.0
27.0
50.0
4.0
4.8
7.0
15.5
19.0
30.7
70.0
VDC
100
200
100
500
0.2
0.2
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
Overvoltage Protection
V1 of dual and triple output models; V1 & V2 outputs of 4-output models.
MPB125-4250 (V1)
MPB125-4350 (V1)
MPB125-2005, MPB125-3000, MPB125-4X50
MPB125-2012
MPB125-2015
MPB125-2024
MPB125-2048
Fully protected against output short circuit. Automatic recovery upon
removal of overload condition.
Total voltage compensation for cable losses on +Sense.
Total voltage compensation for cable losses on -Sense.
TTL compatible signal is high if output is within 97% of nominal.
Delay after outputs have reached 97%.
Overload Protection
Remote Sense (Note 1)
Power Good, Delay High
MIN
Power Good, AC Fail
TTL compatible signal is low if AC power is interrupted for 16 mS. Power
warning before outputs reach 97% of nominal.
NOTES: 1) -Sense must be connected to output common or load common for proper power supply operation.
NOM
1.0
mV
mS
mS
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TÜV).
AC to chassis.
Input to output.
EN55022 Conducted.
Dielectric Withstand Voltage
Electromagnetic Interference
MIN
NOM
MAX
UNITS
Approved
1500
3000
B
2
VAC
VDC
Class
Advanced Produc
t
Release
MPB125 SERIES
SAFETY, REGULATORY, AND EMI SPECIFICATIONS (CONTINUED)
PARAMETER
CONDITIONS/DESCRIPTION
Flicker
Radiated Susceptibility
EFT/Burst
Input Transient Protection
RF Immunity
Magnetic Fields
Voltage Dips
Insulation Resistance
Leakage Current
Per EN61000-3-3.
Per EN61000-4-3.
Per EN61000-4-4.
Per EN61000-4-5.
Per EN61000-4-6.
Per EN61000-4-8.
Per EN61000-4-11.
Input to output.
Per EN60950 (264 VAC)
MIN
NOM
MAX
UNITS
1.0
M⍀
mA
10
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating
Non-Operating
Operating Temperature
Storage Temperature
Forced-Air Cooling
Temperature Coefficient
Relative Humidity
Shock
Vibration
MIN
At 100% load:
Forced-air cooling of 130 LFM at 5 CFM is required for full output power. Air
velocity is measured with power supply mounted on 0.375" (9.5mm) standoffs.
Airflow direction is from the input section to the output section.
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Operating: 11 ±3mS, 3 axes, Half Sine.
Non-operating: 11 ±3mS, 3 axes, Half Sine.
Operating:
Random vibration, 5-500 Hz, 10 minutes each axis.
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
3
NOM
0
-40
±0.02
5
MAX
10K
50K
50
70
±0.05
85
15
30
2.4
4.8
UNITS
ASL Feet
°C
°C
%/°C
%RH
G
GRMS
GRMS
Advanced Produc
t
Release
MPB125 SERIES
J1 - AC I/P CONN.
Pin 1
Pin 2
Pin 3
5.00"
(127.0)
Ø 0.16" (4 PL)
(4.06)
4.55"
(115.57)
J1- INPUT
CONNECTOR
2.56"
(65.02)
J2 - DC OUTPUT
CONNECTOR
TOP VIEW
3.00"
(76.2)
PIN #1
MPB125-3000
MPB125-4250
MPB125-4350
PIN #1
FASTENER
CLEARANCE
AREA (4 PL)
NEUTRAL
NO PIN
LINE
J2 -
MPB125
-3000
-12V
+12V
N/C
N/C
N/C
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 13
Pin 14
MPB125
-4250
-12V
+12V
+2.5V
+2.5V
+2.5V
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
MPB125
-4350
-12V
+12V
+3.3V
+3.3V
+3.3V
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
J3 SAFETY GROUND
CONNECTION POINT
SCREWS SHOWN
FOR REFERENCE
ONLY
J3
PIN #1
0.06"
(1.5)
-SENSE
+SENSE
PWR GOOD
1.00"
(25.4)
1.25"
(31.75)
SIDE VIEW
END VIEW
PRINTED CIRCUIT BOARD
0.19"
(4.8)
J2 - DC OUTPUT
CONNECTOR
J2 - DC OUTPUT
CONNECTOR
MPB125-2005
PIN #1
J2 - DC OUTPUT
CONNECTOR
Pin 1
Pin 2
Pin 3
MPB125-2024
PIN #1
J3
PIN #1
PIN #1
PIN #1
MPB125-2012
MPB125-2015
PIN #1
J2 - DC OUTPUT
CONNECTOR
MPB125-2048
PIN #1
PIN #1
J3
J3
J3
MATING CONNECTORS
NOTE: PART NUMBERS ARE MOLEX; EQUIVALENTS ARE ACCEPTABLE.
MPB125
-2005
MPB125
-2012
-2015
MPB125
-2012
-2015
MPB125
-2024
MPB125
-2048
Housing
09-50-8033
09-50-8033
09-50-8033
09-50-8033
09-50-8033
Pins
08-52-0113
08-52-0113
08-52-0113
08-52-0113
08-52-0113
08-52-0113
J2
Housing
09-50-8103
09-50-8063
09-50-8063
09-50-8043
09-50-8023
09-50-8143
Pins
08-52-0113
08-52-0113
08-52-0113
08-52-0113
08-52-0113
08-52-0113
J3
Housing
22-01-3067
22-01-3067
22-01-3067
22-01-3067
22-01-3067
22-01-3037
Pins
08-50-0114
08-50-0114
08-50-0114
08-50-0114
08-50-0114
08-50-0114
J1
4
MPB125
-3000
-4250
-4350
09-50-8033
Similar pages