EMCORE 2991R-F7-SA

DATA SHEET| DECEMBER 27, 2007
Model 3091A Outdoor Enclosure
for L–Band Links using the 2991T/R
EMCORE’s Model 3091A Outdoor Enclosure (ODU) provides power
and environmental protection for up to four 2991 transmitters or
receivers. With a weather-tight seal and all the necessary internal
connections and mounting hardware, these ODU’s may be placed
directly at the antenna to provide greater flexibility in design.
Applications
TVRO
Broadcast
Earth Stations
Headends
Two AC to DC power supplies drive the four transmitters or receivers
and provide enough additional current for four LNB’s. Further, these
power supplies are redundant, hot swappable and monitored with a
summary alarm, so if one fails the facility staff can replace it and still
maintain 100% signal availability. The individual transmitters and
receivers also are hot swappable, thus can be replaced or reconfigured
without upsetting any of the other RF paths.
VSAT
GPS
Features
Weather Sealed
Summary Alarm
Redundant Power Supplies
Performance Highlights
AC Input
LNB Power, total for all outputs
Ambient Air Temperature
Min
Typical
Max
Units
95
--
240
VAC
--
24
--
V
--
--
1.2
A
-30
--
50
°C
AC input of 95 to 264 VAC
LNB Power
Summary Alarm & Discrete Monitors
Hot-swappable PS, Tx, & Rx
Modular, Field-configurable
Lightning Protected RF
DC Monitor & Bias
Board
Tx/Rx
Unit 1
Tx/Rx
Unit 4
Discrete M&C Interface
Local RS-232 Interface
PS #1
PS #2
J1
AC 1
In
Tx/Rx
Unit 3
Tx/Rx
Unit 2
J3
RF 1
J4
RF 2
Fiber
Feed
Through
J5
RF 3
J6
RF 4
J11
Discrete
M&C
3091A Outdoor Unit for 2991T/R
DATASHEET | DECEMBER 27, 2007
Environmental
•
•
•
•
•
Ambient outside air temperature: -30 to 50°C
Storage temperature: -40°C to +85°C
Start Up Temperature: 0°C min
Humidity, non-condensing: 5 to 95%
Absolute Maximum Rating (damage may occur beyond these limits) < -30°C and > +70°C
Electrical
AC Power Input (Connector J1)
Compatible with 0.5 inch cable diameters and styles.
Parameters
AC Voltage
AC Current
Min
95
--
Typ
---
Max
240
2
Unit
VAC
Amps
Pin
1
2
3
Circuit Breaker Switch: 5 amp trigger
Mating Connector for J1
Face View (Mating Side)
1
2
1
3
Rear View (Solder Side)
2
1
1
3
Function
Line
Neutral
Ground
3091A Outdoor Unit for 2991T/R
DATASHEET | DECEMBER 27, 2007
Controls and Monitor (J11)
•
•
•
LEDs (Inside unit)
Pin
Function
1
Ground
2
Summary Alarm
3
Summary Alarm
4
Power Supply – A
5
Power Supply – A
6
Power Supply – B
7
Power Supply – B
8
Unit 1
9
Unit 1
10
Unit 2
11
Unit 2
12
Unit 3
13
Unit 3
14
Unit 4
15
Unit 4
16
No Connect
Relays are all normally closed.
Relays open for alarm condition or lack of power.
Relays can pass 2 Amps.
RF / Opt Pwr Unit 1
RF / Opt Pwr Unit 2
RF / Opt Pwr Unit 3
RF / Opt Pwr Unit 4
Summary Alarm
Door Open
Pwr Sply A
Pwr Sply B
RF / Opt Power- Unit 1, 2, 3 or 4
• Green = OK
• Red = Fault
For Transmitter: RF / Opt LED indicates
“Low RF Power”.
For Receiver: RF / Opt LED indicates
“Low Optical Power”.
Switches
Mechanical switches S1 – S8 allow the user to select if 2991 is present & if Tx or Rx.
Transmitter and Receiver equipment
The 2991 equipment is ordered separately and can either be factory or field installed.
Transmitter Model Number
2991TL-F7-SA1303
2991TS-F7-SA1303
Description
Tx, 75Ω Type “F”, Low Gain, mounting plate,
coaxial cable, lightning protector and dc harness
Tx, 75Ω Type “F”, Standard Gain, mounting plate,
coaxial cable, lightning protector and dc harness
Receiver Model Number
2991R-F7-SA
Description
Rx, 75Ω Type “F”, Rx mounting plate, coaxial
cable, lightning protector and dc harness
Additional Parts
3091PS-24
Description
+24 VDC Power Supply, Mounting Bracket, AC
Harness, DC Harness, Thermal Pad
3091A Outdoor Unit for 2991T/R
DATASHEET | DECEMBER 27, 2007
Mechanical Outline Drawing
6.27
Regulatory: At the time of this datasheet revision date Dec.27 2007, the 3091 has not been
confirmed to be compliant with CE nor RoHS.
Information contained herein is deemed to be reliable and accurate as of issue date. EMCORE reserves the right to change the design or specifications of
the product at any time without notice. Ortel, the Ortel logo, EMCORE, and the EMCORE logo are trademarks of EMCORE Corporation.
EMCORE Corporation
ds.3091A ODU
2015 West Chestnut Street
Alhambra, California 91803-1542
Tel: 626-293-3400
Fax: 626-293-3428
www.emcore.com
Copyright 2007. EMCORE Corporation