ETC2 MPF2-115RSI Photoelectrics through-beam system, relay output Datasheet

Photoelectrics
Through-beam System, Relay Output
Type MPF.RS
•
•
•
•
•
•
•
•
•
•
•
•
•
Industrial doors and gates
Range: 15 m
Modulated infrared light
Option with individually adjustable channel sensitivity
Amplifier with “Snap-ON” photoelectric switches
Supply voltage: 12-24 VAC/DC, 115 VAC or 230 VAC
Output: SPST relay
LED indications for light ON and supply ON
4 module M36 DIN rail housing
Ø12 mm “Snap-ON”, Ø18 or M14 photoelectric housing
1, 2 or 3 multiplexed channels
With make or break test input
UL 325, EN 12453 (TÜV approved)
Product Description
Ordering Key
The MPFRS.. is a family of
inexpensive general purpose
photoelectric sensors in 3 different types of housings with
separate amplifier. They are
designed to meet the requirements for industrial doors and
gates. The “Snap-ON” photo
switch can be mounted in
material with a thickness from
0.6 mm and up to 2.25 mm.
The sensor set is easy to use
and no adjustments are necessary. The amplifier has a
Amplifier
test input designed to disable
the emitters and therefore
evaluate the sensor function.
Multiplexed channels prevent
cross-talk between each set
of photosensors. The amplifiers are available with the following
voltages:
12-24
VAC/DC, 115 VAC and 230
VAC. The output is made as
positive security e.g. power
lost, short-circuit or broken
sensor cable makes the relay
go to off state.
Type Selection, Amplifier
MPF 3 230 RS AI
Type
Number of channels
Voltage supply
Output relay
Safety
Adjustable sensitivity
Inverted test input (break)
Sensor
MPF T 15 M14 4C
Type
Emitter
Range
Housing diameter
Optical angle
Connectors on cable
Housing
WxHxD
Ordering no.
Supply: 12-24 VAC/DC
Ordering no.
Supply: 115 VAC
Ordering no.
Supply: 230 VAC
70 x 57 x 86 mm
MPF1-912 RS
MPF2-912 RS
MPF3-912 RS
MPF1-912 RSI *)
MPF2-912 RSI *)
MPF3-912 RSI *)
MPF1-912 RSA *)
MPF2-912 RSA *)
MPF3-912 RSA *)
MPF1-912 RSAI *)
MPF2-912 RSAI *)
MPF3-912 RSAI *)
MPF1-115 RS
MPF2-115 RS
MPF3-115 RS
MPF1-115 RSI *)
MPF2-115 RSI *)
MPF3-115 RSI *)
MPF1-115 RSA *)
MPF2-115 RSAv
MPF3-115 RSA *)
MPF1-115 RSAI *)
MPF2-115 RSAI *)
MPF3-115 RSAI *)
MPF1-230 RS
MPF2-230 RS
MPF3-230 RS
MPF1-230 RSI *)
MPF2-230 RSI *)
MPF3-230 RSI *)
MPF1-230 RSA *)
MPF2-230 RSA
MPF3-230 RSA *)
MPF1-230 RSAI *)
MPF2-230 RSAI *)
MPF3-230 RSAI *)
*) Products available on request
Type Selection, Photoelectric Switch
Housing
diameter
Rated
operational
distance (Sn)
Optical
angle
Ordering no.
Emitter
Ordering no.
Receiver
Ø12 mm
M14
D18
Ø12 mm
M14
D18
Fitting for Ø12
15 m
15 m
15 m
15 m
15 m
15 m
4°
4°
4°
4°
4°
4°
MPFT 15-4
MPFT 15-M14-4
MPFT 15-D18-4
MPFT 15-4C
MPFT 15-M14-4C
MPFT 15-D18-4C
MPFR-4
MPFR-M14-4
MPFR-D18-4
MPFR-4C
MPFR-M14-4C
MPFR-D18-4C
Specifications are subject to change without notice (12.09.2005)
Ordering no.
Fitting
AMPF-MB1
1
MPFRS
Specifications, Amplifier
Rated operational volt.
AC types (UB)
Terminals 1 & 3
MPF.- 230 RS.
MPF.- 115 RS.
MPF.- 912 RS.
Dielectric voltage
MPF.- 230 RS.
Rated impulse withstand volt.
Rated operational power
MPF.- 912 RS
AC supply
DC supply
MPF.- 115/230 RS
AC supply
DC supply
Output Specifications
Resistive load
MPF.-xxx RS, RSA, RSI, RSAI
600.000 switchings
300.000 switchings
100.000 switchings
AC15
AC14
DC13
Rated insulation volt. (Ui)
MPF.- 230 RS.
MPF.- 115 RS.
MPF.- 912 RS.
Operating frequency (f)
Light/dark ratio 1:1
Contact output
Response time
OFF-ON (tON)
ON-OFF (tOFF)
Power ON delay (tv)
230 VAC ± 15%, 50 to 60 Hz
115 VAC ± 15%, 50 to 60 Hz
12-24 VAC/DC ± 15%, 50 to 60 Hz
4 kVAC (rms)
4 kV (1.2/50 μs)
3 VA
2W
max. 4.5 VA
max. 4.5 VA
Output function
MPF1+2
MPF3
Indication function
Supply ON
Beam ON (no object present)
Environment
Overvoltage category
Degree of protection
Pollution degree
Temperature
Operating
Storage
Connection
Protection output
1 A@250 VAC/30 VDC
2 A@250 VAC/30 VDC
2 A@250 VAC/30 VDC (UL)
0.75 A@240 VAC
0.60 A@120 VAC
0.22 A@125 VDC
250 VAC (rms)
120 VAC (rms)
50 VAC (rms), 50 VDC
10 Hz
≤ 50 ms
≤ 40 ms
≤ 300 ms
Test input
MPF.- 230 RS.
MPF.- 115 RS.
MPF.- 912 RS.
Testfunction activated
Testfunction deactivated
MPF.- 912 RSI.
Testfunction deactivated
Testfunction activated
Housing material
Weight
MPF.- 115/230 RS
MPF.- 912 RS
CE-marking
UL-marking
TÛV-marking
Relay 2 x SPST
Relay 2 x SPST + 2 x SPST
LED, green
LED, yellow
III (IEC 66064)
IP 40 (IEC 60529/60947-5-2)
3 (IEC 60664/60664A,
60947-1)
-20° to +60°C (-4° to +140°F)
-30° to +80°C (-22° to +176°F)
Screw terminals
(max. 2.5 mm2)
Reverse output, transients,
short-circuit
Potential-free contact
Potential-free contact
Max. 28 V@15 mA AC/DC
≥ 3.5 V AC/DC
≤ 1.0 V AC/DC
Max. 28 V@15 mA AC/DC
≥ 3.5 V AC/DC
≤ 1.0 V AC/DC
PC
280 g
126 g
Yes
Yes (UL 508, UL 325)
Yes (EN 12453)
Specifications, Photoelectric Switches
Rated operation dist. (Sn)
Light source
Light type
Ambient light
Housing material
MPFT15-4/C
MPFT15-D18-4/C
MPFR-4/C
MPFR-D18-4/C
Housing
Backpart
MPFT15-M14-4/C
MPFR15-M14-4/C
Housing
Backpart
Connection
MPFT15-XXX-4
MPFR15-XXX-4
Cable
2
15 m - 8 m (UL 325)
LED 880 nm
Infrared modulated
> 20.000 lux
PC
ABS
Stainless steel/PC
PTE
PVC, grey, 10 m, Ø 2.9 mm2
MPFT15-XXX-4C
Red connector pair
MPFR15-XXX-4C
White connector pair
Connector is placed 15 cm from sensorhead
Cable
PVC, grey, 10 m, Ø 2.9 mm2
Degree of protection
IP 67 (IEC 60529/60947-5-2)
Mounting
“Snap-ON”
Ø12 mm or fitting
MPFT15-4/C
MPFR-4/C
Rubber profile
MPFT15-D18-4/C
MPFR-D18-4/C
D18
Threaded barrel
MPFT15-M14-4/C
MPFR-M14-4/C
CE-marking
UL-marking
TÛV-marking
M14
Yes
Yes (UL 508, UL 325)
Yes (EN 12453)
Specifications are subject to change without notice (12.09.2005)
MPFRS
2)
RX3
1)
RX2
RX1
2)
TX2
TX3
1)
TX1
RX3
RX2
RX1
TX1
TX2
TX3
Wiring Diagrams
13 14 15 16 17 18 19 20 21 22 23 24
3
2
1
1
EMITTER
2
3
13 14 15 16 17 18 19 20 21 22 23 24
TEST
RECEIVER
3
2
RD
RD
1
1
BK
RD
BK
BK
EMITTER
BU
BK
2
3
BU
BU
TEST
RECEIVER
+
OUT 3 250 VAC OUT 1+2
SUPPLY
230 V
+
1
2
30 VDC
Max. 2 A TP
TP
3
4
5
6
7
8
+
SUPPLY
115/230 V
9 10 11 12
OUT 3 250 VAC OUT 2
30 VDC
Max. 2 A TP
TP
1
2
3
4
5
6
7
8
9 10 11 12
1) Not MPF1 and MPF2
2) Not MPF1
1) Not MPF1 and MPF2
2) Not MPF1
Test input make, shown for 115/230 version
Test input break, shown for 115/230 version
AC/DC
1
AC/DC
AC/DC
23
24
TEST
23
AC/DC
24
23
TEST
24
23
TEST
DC
24
TEST
DC
DC
23
24
TEST
23
DC
23
24
TEST
24
TEST
Test input make, shown for 912 version
23
24
TEST
Test input break, shown for 912 version
Operation Diagram
Power supply
Object present
Output contact closed
Tv
Toff
Specifications are subject to change without notice (12.09.2005)
Ton
Ton
3
MPFRS
Detection Diagram
Excess Gain
Emitter
Y
X
(feet)
Receiver
60
65.6
23.8
40
15.7
20
7.9
0
0
-20
-7.9
-40
-15.7
-60
-23.8
0
26.2
4
39.4
8
12
Sensing Range (m)
52.5
16
Excess gain
1000
9.5
(inch)
(cm)
0
100
10
1
1000
10000
20
100000
Range [mm]
Max. Rating
------ Potentiometer in min.
Dimensions
Ø2.9
3
2
1
1
EMITTER
2
CH2
CH3
OUT 3 250 VAC OUT 1+2
30 VDC
MAX 2A
SUPPLY
230 V
Ø11.8
TEST
CH1
MPF3-230RS
PHOTOELECTRIC
AMPLIFIER
2.6
17.3
3
RECEIVER
48
57
70
Amplifier
20
2.6
Ø10
Ø2.9
5
Ø12.8
86
Ø15
M14 x 1
0.6 - 2.25 mm
Ø12
Ø12
M14
19
To be mounted in material with a thickness of 0.6 - 2.25 mm
27.6
8.
5
1
33.2
24
Ø2.9
R6
Ø17.5
28.3
Ø6
Ø22
Fitting for Ø12
4
D18
Specifications are subject to change without notice (12.09.2005)
Installation Hints
To avoid interference from inductive voltage/
current peaks, separate the prox. switch power cables from any other power cables, e.g.
motor, contactor or solenoid cables
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Incorrect
Correct
The cable should not be pulled
Delivery Contents
• Amplifier, MPF..
• Installation instruction
• Packaging: cardboard box
Specifications are subject to change without notice (12.09.2005)
5
Similar pages