Delta MPT136-8R2H1 Mechanical dimension Datasheet

DELTA P/N : MPT136-H1 Series
Mechanical dimensions
Unit : mm
A’
13.45 ± 0.35
A
12.6 ± 0.2
B
5.8 ± 0.2
C
2.0 ± 0.5
C’
2.5 ± 0.1
D
5.0 ± 0.5
D’
6.0 ± 0.2
E
0~0.15
F
5.5
G
8.0
H
14.5
Electrical Characteristics
DCR
Lo @0A
(uH)
± 20%
Ir(Adc)
MPT136-8R2H1
8.2
11.0
MPT136-100H1
10.0
MPT136-120H1
Part No.
(mΩ)
Isat(Adc)
TYP.
MAX
13.5
13.6
16.0
10.0
12.5
18.0
20.7
12.0
7.0
10.0
20.0
23.0
MPT136-150H1
15.0
6.0
9.0
25.0
29.0
MPT136-180H1
18.0
5.0
8.0
30.0
35.0
MPT136-220H1
22.0
5.0
7.5
34.0
39.5
MPT136-270H1
27.0
4.0
6.5
49.0
56.0
MPT136-330H1
33.0
4.0
6.0
65.0
75.0
MPT136-470H1
47.0
3.5
5.5
80.0
90.0
MPT136-680H1
68.0
3.0
4.5
120.0
140.0
MPT136-101H1
100.0
2.5
3.5
180.0
200.0
MPT136-121H1
120.0
2.3
3.2
210.0
235.0
MPT136-151H1
150.0
2.0
2.7
300.0
350.0
NOTES:
(1)
All test data is referenced to 25℃ ambient.
(2)
Ir is the DC current which cause the surface temperature of the part increse approximate 40℃
(3)
Isat is the DC current which cause the inductance drop approximate 30% of Lo.
(4)
Operating temperature range -55℃ to 125℃. (The part temperature should be keepped under 125℃
when the worse operating condition apply on it. Circuit design, component placement,
PWB tracesize and thickness, airflow and other cooling provision may affect the part temperature.
Part temperature should be verified in the end application.)
(5)
The rated current is depended on Ir and Isat which one is lower.