DELTA P/N : MPT724-H1 Series Mechanical dimensions Unit : mm A’ 6.95 ± 0.35 A 6.6 ± 0.2 B 2.2 ± 0.2 C 1.6 ± 0.3 C’ 2.0 ± 0.1 D 3.0 ± 0.3 D’ 3.6 ± 0.2 E 0~0.15 F 3.5 G 3.7 H 8.4 Electrical Characteristics DCR Lo @0A Part No. (uH) Ir(Adc) ± 20% MPT724-R10H1 MPT724-R20H1 MPT724-R22H1 MPT724-R33H1 MPT724-R47H1 MPT724-R56H1 MPT724-R68H1 MPT724-1R0H1 MPT724-1R5H1 MPT724-2R2H1 MPT724-3R3H1 MPT724-4R7H1 MPT724-5R6H1 MPT724-6R8H1 MPT724-100H1 MPT724-150H1 0.1 0.2 0.22 0.33 0.47 0.56 0.68 1.0 1.5 2.2 3.3 4.7 5.6 6.8 10.0 15.0 (mΩ) Isat(Adc) 30.0 25.0 21.0 18.0 15.0 13.0 12.0 9.0 9.0 7.0 5.5 5.0 5.0 4.0 3.1 2.5 70.0 50.0 34.0 24.5 22.0 17.0 16.0 16.0 15.0 14.0 13.0 10.0 6.5 6.0 4.0 3.3 TYP. MAX 1.5 2.2 2.6 3.5 4.5 5.9 6.2 11.2 17.0 23.0 31.0 41.0 51.0 57.0 92.0 145.0 1.7 2.8 3.2 4.1 5.1 6.5 7.2 13.5 20.0 28.0 39.0 50.0 60.0 70.0 101.0 160.0 NOTES: (1) All test data is referenced to 25℃ ambient. (2) Ir is the DC current which cause the surface temperature of the part increse approximate 40℃ (3) Isat is the DC current which cause the inductance drop approximate 30% of Lo. (4) Operating temperature range -55℃ to 125℃. (The part temperature should be keepped under 125℃ when the worse operating condition apply on it. Circuit design, component placement, PWB tracesize and thickness, airflow and other cooling provision may affect the part temperature. Part temperature should be verified in the end application.) (5) The rated current is depended on Ir and Isat which one is lower.