MPU15C SERIES 15W Desk Top Switching Power Supplies For Medical Equipment. Description: The MPU15C series of AC/DC switching mode power supplies provide 15 Watts of continuous output power and is well-suited for a variety of applications. All supplies are UL 94V-1 min compliant. All models comply with UL/c-UL(UL 606011:2ndEdition), TUV/T-mark(EN 60601-1:2ndEdition) and new CE requirements. All units are 100% burned-in and tested. Features: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C6 Input Inlet Single Output Energy Star 2.0, Efficiency level V Over Voltage and Over Load protection. Over temperature Detection Class I 3 year warranty Safety Approvals: EN 60601-1 IEC 60601-1 RT Electrical Characteristics: Sym. Vin Parameter PS E CB Agree to apply for the PSE if order on hand Min. Typ. Max. Unit Safety Approvals Input Voltage Range Test Conditions 100 240 VAC Operate Voltage Range 90 264 VAC fin Input Frequency 47 63 Hz Po Output Power Range 0 15 W Vo Output Voltage Range Vin=90 to 264VAC See rating chart V See rating chart A Io Output Current Range Iil Input Current (Low Line) Io=Full load, Vin=115VAC 0.25 0.33 A Iih Input Current (High Line) Io=Full load, Vin=230VAC 0.17 0.18 A Irl Low Line Inrush Current Io=Full load, 25c, Cool start, Vin=115VAC 18 23 A Irh High Line Inrush Current Io=Full load, 25c, Cool start, Vin=230VAC 38 45 A Eff Efficiency Io=Full Load, Vin=230VAC REG-i Line Regulation Io=Full Load REG-o Load Regulation Vin=230VAC 1 ○ OVP Over Voltage OCP 1 Over Current○ Protection Ttr Time of Transient Response Protection Thold Hold-Up Time Ts Vp-p Start Up Time 85 % 0.5 1 % 3 5 % 112 132 % 110 150 % 4 mS 1 Io=Full Load to Half Load, Vin=100VAC Io=Full Load, Vin=110VAC 10 Io=Full Load, Vin=100VAC Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC TC Temperature Coefficient All output Pno No-Load Power Consumption No load, Vin=230VAC The parameter is not subject to production test-verified by design/characterization of integrated controller. Tjsd 73 1 by Thermal Shutdown○ Junction Temperature Controller 16 1 S 0.5 1 % 0.3 mA 0.04 %/c 0.3 W 125 c -0.04 0 mS 0.5 0.25 -20 1 When the power system interruption is isolated, the product would re-start after recovering by hand. ○ Environmental : Sym. Toper Tstg Ho Hr Parameter T e s t Conditions Operating Temperature Min. Typ. Max. Unit 50 C 0 70 Storage Temperature -40 85 C Operating Humidity 0 95 % Storage Humidity 0 75 % MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 50 C to 50% load at 70 C 0.1M Hrs MPU15C SERIES 15W Desk Top Switching Power Supplies For Medical Equipment. Safety Specifications: Sym. Vps Vpg Ris Parameter Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2828 VDC T e s t Conditions Dielectric Withstanding Voltage for Primary to secondary Dielectric Withstanding Voltage for Primary to Ground Isolation Resistance E N 5 5 0 2 2 EMI requirements for EN55022 EMI requirements for FCC PART-18 FCC M Test Voltage=500VDC 50 Vin=230VAC,50HZ B CLASS Vin=120VAC,60HZ B CLASS Output Voltage And Current Rating Chart ( Single Output ) : ① * * * * Model Number Output Voltage Output Current Total Regulation Maximum Output Power MPU15C-102 5 ~ 6 VDC 2.60~2.16 A 5% 13W MPU15C-103 6 ~ 8 VDC 2.16~1.62 A 5% 13W MPU15C-104 8 ~ 11 VDC 1.87~1.36 A 5% 15W MPU15C-105 11 ~ 13 VDC 1.36~1.15 A 5% 15W MPU15C-106 13 ~ 16 VDC 1.15~0.93 A 5% 15W MPU15C-107 16 ~ 21 VDC 0.93~0.71 A 5% 15W MPU15C-108 21 ~ 27 VDC 0.71~0.55 A 3% 15W MPU15C-109 27 ~ 33 VDC 0.55~0.45 A 3% 15W MPU15C-110 33 ~ 36 VDC 0.45~0.41 A 3% 15W Mark “ ① * ” means approved by PSE. MPU15C-102.103 are required to use AWG#16 / 4FT output cable. MPU15C-105~110 are required to use AWG#18 / 4FT output cable. The regulation and efficiency will be changed by modified output cable. Mechanical Specifications : Note: 1. Dimensions are shown in mm. 2. Weight: 170gs approx. 3. Optional output connector: See page Appendix.