ETC MR40D-48S15-UM

DC/DC converters
MISTRAL Series MR40, MR40-T
BKJU.436610.011
Ordering information
MR 40 D – 24 S 12 U T
c d e
fg hij
• Completely replace power-supply modules
MDM30-P series on dimensions and purpose of
conclusions and have the improved characteristics
• Working temperature range from -60°C to +125°C
• Single and dual-output models
• Output voltage regulation
• Short circuit protection, overvoltage and thermal
protection
• Remote on/off
• Coefficient of efficiency 82%
• Small size, low-profile
• Metal case
• Cooling by free air convection or a heat sink using
• Galvanic isolated outputs
c - Mistral Series
d - Maximum output power, W
(limiting capacity is designated on the case
for the given standard size, stipulated at the
order)
e - Voltage transformation class
D – DC/DC
f - Nominal input voltage
12 (10,5…18) VDC
24 VDC(18…36) VDC
27 VDC(17…36) VDC
48 VDC(36…75) VDC
g - Output channels quantity
S – one
D – two
h - Nominal output voltage, VDC
(two numbers on channel)
i - Embodiment
U - reinforced aluminium frame with flanges
j - Operating temperature range
M - -60°С…+85°С
T - -60°С…+125°С
Single-output models
Module
Input voltage range
Output power
Output voltage
MR40D-12S05-UM
5 VDC
MR40D-12S15-UM
15 VDC
MR40D-12S24-UM
10,5…18 VDC
40 W
Maximal output current
8A
2,67 A
24 VDC
1,67 A
MR40D-12S27-UM
27 VDC
1,48 A
MR40D-24S05-UM
5 VDC
MR40D-24S15-UM
15 VDC
2,67 A
MR40D-24S24-UM
18…36(40) VDC
40 W
8A
24 VDC
1,67 A
MR40D-24S27-UM
27 VDC
1,48 A
MR40D-27S05-UM
5 VDC
MR40D-27S15-UM
15 VDC
2,67 A
MR40D-27S24-UM
17…36(80) VDC
40 W
8A
24 VDC
1,67 A
MR40D-27S27-UM
27 VDC
1,48 A
MR40D-48S05-UM
5 VDC
MR40D-48S15-UM
15 VDC
2,67 A
24 VDC
1,67 A
27 VDC
1,48 A
Output voltage
Maximal output current
5 VDC / 12 VDC
4 A / 1,67 A
MR40D-48S24-UM
36…75 VDC
40 W
MR40D-48S27-UM
8A
Dual-output models
Module
Input voltage range
Output power
MR40D-12D0512-UM
MR40D-12D0515-UM
10,5…18 VDC
40 W
MR40D-12D1515-UM
MR40D-24D0512-UM
40 W
MR40D-24D0515-UM
MR40D-24D1515-UM
18…36(40) VDC
MR40D-27D0512-UM
40 W
MR40D-27D0515-UM
MR40D-27D1515-UM
17…36(80) VDC
MR40D-48D0512-UM
MR40D-48D0515-UM
MR40D-48D1515-UM
36…75 VDC
40 W
5 VDC / 15 VDC
4 A / 1,33 A
15 VDC / 15 VDC
1,33 A / 1,33 A
5 VDC / 12 VDC
4 A / 1,67 A
5 VDC / 15 VDC
4 A / 1,33 A
15 VDC / 15 VDC
1,33 A / 1,33 A
5 VDC / 12 VDC
4 A / 1,67 A
5 VDC / 15 VDC
4 A / 1,33 A
15 VDC / 15 VDC
1,33 A / 1,33 A
5 VDC / 12 VDC
4 A / 1,67 A
5 VDC / 15 VDC
4 A / 1,33 A
15 VDC / 15 VDC
1,33 A / 1,33 A
‘ By request can be delivered modules with non-standard output voltage 3 to 80VDC and with maximal output current
http://www.aeps-group.com
e-mail: [email protected]
tel/fax: +420-266-107-609
to 8А.
According to company politics in view of constant improvements production design the
manufacturer reserves the right to itself without the prior notification to change the contents
of present help materials.
© "Alexander Eleсtriс holding". All rights reserved. 31.03.2008
http://www.aeps-group.com
e-mail: [email protected]
tel/fax (4732) 519-518
DC/DC converters
MISTRAL Series MR40, MR40-T
Technical specifications according to BKJU.436610.011
Input specifications
Input voltage range/ transitional deviation, 1 sec
12 VDC
24 VDC
27 VDC
48 VDC
Input filter
10,5…18VDC/ 10,5…18VDC
18…36VDC/17..37,8VDC
17…36VDC/17…80VDC
36…75VDC/36…84VDC
P-type
Output specifications
Output voltage trimming range (for single-, dual-output execution with same
voltage)
Output voltage total instability
±5%
±4%
±6%
±4%
±6%
±4%
±6%
- for single-output execution (Inom 10 – 100%)
- for multi-output execution (Inom 10 – 100%)
- for multi-output execution with distinction voltage ≥20%
Pulsations ripple (peak-to-peak)
Overload protection level**
Short circuit protection level**
Overvoltage protection level**
<2% Uout.nom.
>120% Iout.nom.
>150 % Iout.nom., autorepair
>120 % Uout.nom.
Off: 0…1,1VDC or connection of output «ON» and
«- IN», I≤5 mA
Remote on/off
General specifications
–
–
–
–
- high working of case
Temperature
(index “M”)
(index “T”)
for out1 ±7% for out2 (index “M”)
for out1 ±10% for out2 (index “T”)
for out1 ±14% for out2&3 (index “M”)
for out1 ±14% for out2&3 (index “T”)
- storage
1
60
60
60
60
°C…+85 °C
°C…+125 °C
°C…+85 °C
°C…+125 °C
(index “M”)
(index “T”)
(index “M”)
(index “T”)
See diagram (red, green lines)
- power loss (free air convection)
Without power loss with radiator use (provided that Тcase. The module does not exceed the maximal value) see blue curve
Efficiency
82 %
Thermal resistance case - environment
7,8 ºС/Watt
Conversion frequency
Isolation
150 kHz
~ 355 VDC, 50 Hz
≥20 Ohm
- voltage in/out: in/case: out/case:
Insulation resistance @ 500VDC
External factors stability
- high humidity
EMC standard
Safety standard
Time to failure
Cooling
Case material
‘
100% @ 35°С
EN 55022, class A
IEC/ EN 60950
> 2 400 000 hours @ +25°C
Free air convection or heat sink using
Metal
All specifications are reduced for normal climatic conditions, Uin.nom, Iout.nom, if it is not specified differently.
‘‘ Parameters are help and cannot be used at long-term work, excess of the maximal target current, at work outside of a range of working
temperatures, at work of the module with target voltage over a range of adjustment
50
45
40
35
30
MR40
Power loss diagram (index «Т»)
Free air convection
coefficient of efficiency 80%
25
20
15
10
5
0
Free air convection
coefficient of efficiency 84%
-60 -50 -40 -30 -20 -10 0
MR40-T
Heat sink
Output power, W
В ыOutput
х о д н а яpower,
м о щ нWо с т ь , В т
Power loss diagram (index «М»)
Heat sink
Free air convection
coefficient of efficiency 80%
Free air convection
coefficient of efficiency 84%
10 20 30 40 50 60 70 80 90
Ambient temperature
Температура
окружающейTamb,
среды°C
Токр, С
Ambient temperature Tamb, °C
* The inclined site of a red and green curve specifies that the module works in a mode with maximal Тcase (index «М» +85ºС; index «Т» +125 ºС).
Output settings
№ pin
Single-output
1
Case.
2
+ in
3
- in
4
On/off
5
+ out
6
- out
7
Trim.
8
-
Dual-output
Case.
+ in
- in
On/off
+ out 1
+ out 2
- out 2
- out 1
http://www.aeps-group.com
e-mail: [email protected]
tel/fax: +420-266-107-609
According to company politics in view of constant improvements production design the
manufacturer reserves the right to itself without the prior notification to change the contents
of present help materials.
© "Alexander Eleсtriс holding". All rights reserved. 31.03.2008
http://www.aeps-group.com
e-mail: [email protected]
tel/fax (4732) 519-518
DC/DC converters
MISTRAL Series MR40, MR40-T
МR40-S case with flanges
МR40-D case with flanges
http://www.aeps-group.com
e-mail: [email protected]
tel/fax: +420-266-107-609
According to company politics in view of constant improvements production design the
manufacturer reserves the right to itself without the prior notification to change the contents
of present help materials.
© "Alexander Eleсtriс holding". All rights reserved. 31.03.2008
http://www.aeps-group.com
e-mail: [email protected]
tel/fax (4732) 519-518