DC/DC converters MISTRAL Series MR40, MR40-T BKJU.436610.011 Ordering information MR 40 D – 24 S 12 U T c d e fg hij • Completely replace power-supply modules MDM30-P series on dimensions and purpose of conclusions and have the improved characteristics • Working temperature range from -60°C to +125°C • Single and dual-output models • Output voltage regulation • Short circuit protection, overvoltage and thermal protection • Remote on/off • Coefficient of efficiency 82% • Small size, low-profile • Metal case • Cooling by free air convection or a heat sink using • Galvanic isolated outputs c - Mistral Series d - Maximum output power, W (limiting capacity is designated on the case for the given standard size, stipulated at the order) e - Voltage transformation class D – DC/DC f - Nominal input voltage 12 (10,5…18) VDC 24 VDC(18…36) VDC 27 VDC(17…36) VDC 48 VDC(36…75) VDC g - Output channels quantity S – one D – two h - Nominal output voltage, VDC (two numbers on channel) i - Embodiment U - reinforced aluminium frame with flanges j - Operating temperature range M - -60°С…+85°С T - -60°С…+125°С Single-output models Module Input voltage range Output power Output voltage MR40D-12S05-UM 5 VDC MR40D-12S15-UM 15 VDC MR40D-12S24-UM 10,5…18 VDC 40 W Maximal output current 8A 2,67 A 24 VDC 1,67 A MR40D-12S27-UM 27 VDC 1,48 A MR40D-24S05-UM 5 VDC MR40D-24S15-UM 15 VDC 2,67 A MR40D-24S24-UM 18…36(40) VDC 40 W 8A 24 VDC 1,67 A MR40D-24S27-UM 27 VDC 1,48 A MR40D-27S05-UM 5 VDC MR40D-27S15-UM 15 VDC 2,67 A MR40D-27S24-UM 17…36(80) VDC 40 W 8A 24 VDC 1,67 A MR40D-27S27-UM 27 VDC 1,48 A MR40D-48S05-UM 5 VDC MR40D-48S15-UM 15 VDC 2,67 A 24 VDC 1,67 A 27 VDC 1,48 A Output voltage Maximal output current 5 VDC / 12 VDC 4 A / 1,67 A MR40D-48S24-UM 36…75 VDC 40 W MR40D-48S27-UM 8A Dual-output models Module Input voltage range Output power MR40D-12D0512-UM MR40D-12D0515-UM 10,5…18 VDC 40 W MR40D-12D1515-UM MR40D-24D0512-UM 40 W MR40D-24D0515-UM MR40D-24D1515-UM 18…36(40) VDC MR40D-27D0512-UM 40 W MR40D-27D0515-UM MR40D-27D1515-UM 17…36(80) VDC MR40D-48D0512-UM MR40D-48D0515-UM MR40D-48D1515-UM 36…75 VDC 40 W 5 VDC / 15 VDC 4 A / 1,33 A 15 VDC / 15 VDC 1,33 A / 1,33 A 5 VDC / 12 VDC 4 A / 1,67 A 5 VDC / 15 VDC 4 A / 1,33 A 15 VDC / 15 VDC 1,33 A / 1,33 A 5 VDC / 12 VDC 4 A / 1,67 A 5 VDC / 15 VDC 4 A / 1,33 A 15 VDC / 15 VDC 1,33 A / 1,33 A 5 VDC / 12 VDC 4 A / 1,67 A 5 VDC / 15 VDC 4 A / 1,33 A 15 VDC / 15 VDC 1,33 A / 1,33 A By request can be delivered modules with non-standard output voltage 3 to 80VDC and with maximal output current http://www.aeps-group.com e-mail: [email protected] tel/fax: +420-266-107-609 to 8А. According to company politics in view of constant improvements production design the manufacturer reserves the right to itself without the prior notification to change the contents of present help materials. © "Alexander Eleсtriс holding". All rights reserved. 31.03.2008 http://www.aeps-group.com e-mail: [email protected] tel/fax (4732) 519-518 DC/DC converters MISTRAL Series MR40, MR40-T Technical specifications according to BKJU.436610.011 Input specifications Input voltage range/ transitional deviation, 1 sec 12 VDC 24 VDC 27 VDC 48 VDC Input filter 10,5…18VDC/ 10,5…18VDC 18…36VDC/17..37,8VDC 17…36VDC/17…80VDC 36…75VDC/36…84VDC P-type Output specifications Output voltage trimming range (for single-, dual-output execution with same voltage) Output voltage total instability ±5% ±4% ±6% ±4% ±6% ±4% ±6% - for single-output execution (Inom 10 – 100%) - for multi-output execution (Inom 10 – 100%) - for multi-output execution with distinction voltage ≥20% Pulsations ripple (peak-to-peak) Overload protection level** Short circuit protection level** Overvoltage protection level** <2% Uout.nom. >120% Iout.nom. >150 % Iout.nom., autorepair >120 % Uout.nom. Off: 0…1,1VDC or connection of output «ON» and «- IN», I≤5 mA Remote on/off General specifications – – – – - high working of case Temperature (index “M”) (index “T”) for out1 ±7% for out2 (index “M”) for out1 ±10% for out2 (index “T”) for out1 ±14% for out2&3 (index “M”) for out1 ±14% for out2&3 (index “T”) - storage 1 60 60 60 60 °C…+85 °C °C…+125 °C °C…+85 °C °C…+125 °C (index “M”) (index “T”) (index “M”) (index “T”) See diagram (red, green lines) - power loss (free air convection) Without power loss with radiator use (provided that Тcase. The module does not exceed the maximal value) see blue curve Efficiency 82 % Thermal resistance case - environment 7,8 ºС/Watt Conversion frequency Isolation 150 kHz ~ 355 VDC, 50 Hz ≥20 Ohm - voltage in/out: in/case: out/case: Insulation resistance @ 500VDC External factors stability - high humidity EMC standard Safety standard Time to failure Cooling Case material 100% @ 35°С EN 55022, class A IEC/ EN 60950 > 2 400 000 hours @ +25°C Free air convection or heat sink using Metal All specifications are reduced for normal climatic conditions, Uin.nom, Iout.nom, if it is not specified differently. Parameters are help and cannot be used at long-term work, excess of the maximal target current, at work outside of a range of working temperatures, at work of the module with target voltage over a range of adjustment 50 45 40 35 30 MR40 Power loss diagram (index «Т») Free air convection coefficient of efficiency 80% 25 20 15 10 5 0 Free air convection coefficient of efficiency 84% -60 -50 -40 -30 -20 -10 0 MR40-T Heat sink Output power, W В ыOutput х о д н а яpower, м о щ нWо с т ь , В т Power loss diagram (index «М») Heat sink Free air convection coefficient of efficiency 80% Free air convection coefficient of efficiency 84% 10 20 30 40 50 60 70 80 90 Ambient temperature Температура окружающейTamb, среды°C Токр, С Ambient temperature Tamb, °C * The inclined site of a red and green curve specifies that the module works in a mode with maximal Тcase (index «М» +85ºС; index «Т» +125 ºС). Output settings № pin Single-output 1 Case. 2 + in 3 - in 4 On/off 5 + out 6 - out 7 Trim. 8 - Dual-output Case. + in - in On/off + out 1 + out 2 - out 2 - out 1 http://www.aeps-group.com e-mail: [email protected] tel/fax: +420-266-107-609 According to company politics in view of constant improvements production design the manufacturer reserves the right to itself without the prior notification to change the contents of present help materials. © "Alexander Eleсtriс holding". All rights reserved. 31.03.2008 http://www.aeps-group.com e-mail: [email protected] tel/fax (4732) 519-518 DC/DC converters MISTRAL Series MR40, MR40-T МR40-S case with flanges МR40-D case with flanges http://www.aeps-group.com e-mail: [email protected] tel/fax: +420-266-107-609 According to company politics in view of constant improvements production design the manufacturer reserves the right to itself without the prior notification to change the contents of present help materials. © "Alexander Eleсtriс holding". All rights reserved. 31.03.2008 http://www.aeps-group.com e-mail: [email protected] tel/fax (4732) 519-518