NKK MS12AFG Miniature slide Datasheet

Miniature Slides
Series MS
Distinctive Characteristics
Available in flat frame and bracketed PC mounting types.
Over-center actuator block and plunger design gives crisp
actuation with clear indication of circuit status; this design
also diminishes sparking and increases operating life.
Guide interlocked with actuator block prevents
window locking and maintains correct plunger
alignment to assure contact stability.
Antijamming design protects contacts from
damage due to excessive downward force
on the actuator.
High internal barriers between poles and
insulating sheet between case and actuator
block give added protection to contacts.
Specially composed silver alloy contacts for
power applications or gold contacts for logic
level applications give high contact reliability.
Prominent external insulating barriers increase
insulation resistance and dielectric strength.
Epoxy sealed terminals prevent entry of flux, solvents,
and other contaminants.
Clinching of frame to case well above base and terminals provides
1,500V dielectric strength.
Actual Size
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Miniature Slides
Series MS
General Specifications
Electrical Capacity (Resistive Load)
Power Level (code W):
Logic Level (code G):
Logic/Power Level (code A):
Other Ratings
Contact Resistance:
Insulation Resistance:
Dielectric Strength:
Mechanical Life:
Electrical Life:
Contact Timing:
Total Travel:
Materials & Finishes
Actuator:
Frame:
Dust Cover:
Case:
Movable Contacts:
Stationary Contacts:
Terminals:
Environmental Data
Operating Temp Range:
Humidity:
Vibration:
Shock:
Processing
Soldering:
Cleaning:
Standards & Certifications
Flammability Standards:
UL Recognized:
C-UL Recognized:
R
CSA Certified:
6A @ 125V AC or 3A @ 250V AC
0.4VA maximum @ 28V AC/DC maximum
(Applicable Range 0.1mA ~ 0.1A @ 20mV ~ 28V)
Combines W & G ratings
Note: Find additional explanation of dual rating & operating range in Supplement section.
10 milliohms maximum for silver; 20 milliohms maximum for gold
1,000 megohms minimum @ 500V DC
1,000V AC minimum between contacts for 1 minute minimum;
1,500V AC minimum between contacts & case for 1 minute minimum
100,000 operations minimum
25,000 operations minimum for silver; 50,000 operations minimum for gold
Nonshorting (break-before-make)
On-None-On circuit .087” (2.2mm); all other circuits .138” (3.5mm)
Glass fiber reinforced polyester
Stainless steel for panel & PCB mount; phosphor bronze with tin plating for bracket mount
Phosphor bronze with nickel plating
Glass fiber reinforced diallyl phthalate resin (UL94V-0)
Silver alloy (code W); copper with gold plating (code G);
or silver alloy with gold plating (code A)
Silver capped copper with silver plating (code W); copper with gold plating (code G);
or silver alloy with gold plating (code A)
Copper or brass with silver or gold plating
–30°C through +85°C (–22°F through +185°F)
90 ~ 95% humidity for 96 hours @ 40°C (104°F)
10 ~ 55Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range & returning
in 1 minute; 3 right angled directions for 2 hours
50G (490m/s2) acceleration (tested in 6 right angled directions, with 5 shocks in each direction)
Wave Soldering recommended (PC Mount). See Profile A in Supplement section.
Manual Soldering: See Profile A in Supplement section.
These devices are not process sealed. Hand clean locally using alcohol based solution.
UL94V-0 rated case
All Single & Double Pole Double Throw models recognized at 6A @ 125V AC & 3A @ 250V AC;
UL File No. WOYR2.E44145; add “/U” to end of part number to order UL mark on switch.
All Single & Double Pole Double Throw models recognized at 6A @ 125V AC & 3A @ 250V AC;
UL File No. WOYR8.E44145; add “/C-UL” to end of part number to order C-UL mark on switch.
All Double Throw & 3 Throw models certified at 6A @ 125V AC, 3A @ 250V AC, &
0.4VA maximum @ 28V DC; CSA File No. 023535-0-000; add “/C” to end of part number
to order CSA mark on switch.
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Miniature Slides
Series MS
TYPICAL SWITCH ORDERING EXAMPLE
1
MS
A
2
S
G
POLES
30
TERMINALS
1
SPDT
2
DPDT
SP3T
CIRCUITS
2
ON
NONE
ON
3
ON
OFF
ON
0
ON
ON
ON
MOUNTING
01
Solder Lug
F
Panel Mount
(Terminal 01 only)
03
Straight PC
13
Straight with Bracket
N
PCB Mount
(Terminal 03 only)
30
Right Angle PC
40
Vertical PC
S
Bracket Mount
(Terminals 13, 30, &
40 only)
CONTACT MATERIALS
& RATINGS
ACTUATORS
A
.150” (3.8mm) Wide for
Single or Double Pole
B
.323” (8.2mm) Wide for
Double Pole
W
Silver; Rated 6A @ 125V
AC & 3A @ 250V AC
G
Gold; Rated 0.4VA max. @
28V AC/DC max.
A
Gold over Silver; Rated
6A @ 125V AC & 0.4VA
max. @ 28V AC/DC max.
IMPORTANT:
Switches are supplied without
UL, C-UL & CSA markings unless specified. Specific models
& ratings are noted on General
Specifications page.
DESCRIPTION FOR TYPICAL ORDERING EXAMPLE
MS12ASG30
.150” (3.8mm) Wide
Actuator
SPDT
ON-NONE-ON Circuit
Gold Contacts with 0.4VA Rating
Right Angle PC Terminals
with Support Bracket
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Miniature Slides
Series MS
POLES & CIRCUITS
Slide Position
Pole
SP
DP
Connected Terminals
Left
Center
Right
MS12
ON
NONE
ON
MS13
ON
OFF
ON
MS22
ON
NONE
ON
MS23
ON
OFF
ON
Throw & Schematics
Left
Center
Right
2-1
OPEN
2-3
Note:
Terminal numbers are
not actually on the switch.
Model
2 (COM)
SPDT
1
2-1 5-4
OPEN
2-3 5-6
2
DPDT
1
3
(COM)
3
5
6
4
For 3 Throw (3-On)
Connected Terminals & Schematics
Pole
SP
Model
MS20
Left
Center
Right
ON
ON
ON
External
Connection
5
2 (in)
3 4 (out) 6 (out)
1 (out)
External
Connection
5
2 (in)
1 (out)
2-1 5-4
External Connection
The SP3T model utilizes a
double pole base.
External
Connection
5
2 (in)
3 4 (out) 6 (out)
1 (out)
2-3 5-4
(out)
3 4 (out) 6 (out)
2-3 5-6
External
connections
must be made
during field
installation.
External
Conn
6
3
5
2
4
1
(out)
Common
(in)
(out)
ACTUATORS
A
.150” (3.8mm) Wide
for Single Pole
(3.8)
.150
.150” (3.8mm) Wide
for Double Pole
(3.8)
.150
(3.8)
.150
B
.323” (8.2mm) Wide
for Double Pole Only
(3.8)
.150
(3.8)
.150
(8.2)
.323
CONTACT MATERIALS & RATINGS
W
Silver over Silver
Power Level
6A @ 125V AC & 3A @ 250V AC
G
Gold over Brass or Copper
Logic Level
0.4VA maximum @ 28V AC/DC maximum
Note: Complete explanation of operating range in Supplement section.
A
Gold over Silver
Power Level
or Logic Level
6A @ 125V AC
or 0.4VA maximum @ 28V AC/DC maximum
Note: This dual rated option is suitable when two or more identical switches are used in logic and in power circuits
within the same application. See Supplement section for complete explanation of dual rating and operating range.
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Miniature Slides
Series MS
MOUNTING TYPES & TERMINALS
F
(2.4) Dia Typ
.094
(2.4) Dia Typ
.094
Panel Mount
(Combines with Solder
Lug Terminal 01 only)
A
A
(4.19)
.165
Straight PC Mount
(Combines with
Straight PC Terminal
03 only)
(9.0)
.354
SP or DP with .150”
(3.8mm) Actuator
Maximum Panel Thickness: .197” (5.0mm)
S
(17.53)
.690
(17.53)
.690
Dimension A =
.268” (6.8mm) for on-none-on
.319” (8.1mm) for on-off-on & on-on-on
N
DP only with .323”
(8.2mm) Actuator
Support Bracket Mount
(For Terminals 13, 30, & 40)
Maximum Panel Thickness:
For Straight PC with Bracket Terminal 13: .197” (5.0mm)
For Angle Mount Terminals 30 & 40: .177” (4.5mm)
01
03
Solder Lug
Epoxy Seal
Straight PC
(4.0)
.157
Epoxy Seal
(2.0)
.079
(2.0)
(1.1) .079
.043
Thk = (0.8)
.031
(6.35)
(4.8) .250
.189
(1.17)
.046
Thk = (0.8)
.031
13
Straight PC with Bracket
30
Right Angle PC
40
Vertical PC
TYPICAL SWITCH DIMENSIONS
Solder Lug Terminals
Single Pole
(1.1) x (2.0) Typ
.043 x .079
(1.2) R Typ
.047
(0.8) Typ
.031
ON
(3.8) Sq
.150
(19.6)
.772
(6.1)
.240
(6.6)
.260
MS12AFW01
3
(12.7)
.500
2
(4.7) Typ
.185
ON
(17.53)
.690
(0.4)
.016
(5.1) (6.4) (4.5)
.201 .252 .177
1
(0.5)
.020
(0.5)
.020
(2.0)
.079
Actuator in LEFT Position
Solder Lug Terminals
Double Pole
(1.2) R Typ
.047
(1.2) R Typ
.047
(1.1) x (2.0) Typ
.043 x .079
(2.0) Typ
.079
(17.53)
.690
(19.6)
.772
(3.8)
.150
(6.1)
.240
MS22BFW01
ON
(0.8) Typ
.031
(3.8)
.150
(6.1)
.240
(8.2)
.323
ON
(17.53)
.690
(19.6)
.772
(5.1)
.201
(4.7) Typ
.185
(0.5)
(0.4)
.020
.016
(7.6) (4.5)
.299 .177
6
3
5
2
4
1
(4.8)
.189
(11.4)
.449
(12.7)
.500
(0.5)
.020
Actuator in LEFT Position
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Series MS
Miniature Slides
TYPICAL SWITCH DIMENSIONS
Straight PC Terminals
Single Pole
(0.8) Typ
.031
3
ON
3
ON
(4.7) Typ
.185
Actuator in LEFT Position
Straight PC Terminals
Double Pole
ON
6
ON
(4.7) Typ
.185
(4.8)
.189
(1.17) Typ
.046
(0.8) Typ
.031
(3.8)
.150
(1.8) Dia Typ
.073
(0.5)
.020
(1.17)
.046
MS12ANG03
(4.7) Typ
.185
1
1
(4.8)
.189
(5.1) (6.4) (6.35)
.201 .252 .250
(6.6)
.260
2
(12.7)
.500
2
(3.8) Sq
.150
3
6
2
5
1
4
3
5
2
4
1
(12.7)
.500
(4.7) Typ
.185
(1.8) Dia Typ
.073
(8.2)
.323
(3.8)
.150
MS22BNG03
(5.1)
.201
(7.6)
.299
(4.8)
.189
(11.4)
.449
(4.8)
.189
(6.35)
.250
Actuator in LEFT Position
Straight PC Terminals with Bracket
Single Pole
(3.8)
.150
ON
(4.8)
.189
(0.4) Typ
.016
(3.2)
.126
(1.2) Typ
.047
3
(12.7)
.500
2
(6.7)
.264
(13.1)
.516
(5.1)
.201
Actuator in LEFT Position
Straight PC Terminals with Bracket
Double Pole
(3.8)
.150
(8.2)
.323
ON
(4.8)
.189
(0.8) Typ
.031 (15.8)
(4.7) Typ .622
.185
ON
(3.8)
.150
(0.4) Typ
.016
(0.36)
.014
(10.4)
.409
(10.4)
.409
(5.1)
.201
(6.7)
.264
(14.3)
.563
(3.2)
.126
(1.8) Dia Typ
.073
(1.5) Dia Typ
.059
(0.5)
.020
(1.17)
.046
(1.6) Typ
.063
(2.4) Typ
.095
(1.2) Typ
.047
6
3
5
2
4
1
(1.17) Typ
.046
(4.7) Typ
.185
1
(7.1)
.280
MS12ASG13
(7.9) Typ
.311
2
1
(0.36)
.014
(5.6)
.220
(1.6) Typ
.063
3
(0.8) Typ
.031 (15.8)
(4.7) Typ .622
.185
ON
(3.8)
.150
MS22BSG13
(0.5)
.020
(12.7)
.500
(0.5)
.020
(4.8)
.189
(11.9)
.469
3
6
2
5
1
4
CL
(7.9) Typ
.311
(4.7) Typ
.185
(1.8) Dia Typ
.073
(1.5) Dia Typ
.059
Actuator in LEFT Position
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com
03-07
Series MS
Miniature Slides
TYPICAL SWITCH DIMENSIONS
Right Angle PC Terminals
Single Pole
(5.1)
.201
(12.7)
.500
1
(3.8) Sq
.150
(0.4) Typ
.016
MS12ASG30
(1.2)
.047
(9.53)
.375
(1.27)
.050
(1.8) Dia Typ
.073
(4.7) Typ
.185
3
(6.6)
.260
(3.2)
(3.81) .126
.150
(5.7)
.224
(13.2)
.520
2
3
2
1
(9.53)
.375
(0.5)
.020
(0.8) Typ
.031
(4.7) Typ
.185
(6.6) Typ
.260
(1.5) Dia Typ
.059
Actuator in LEFT Position
Right Angle PC Terminals
Double Pole
(3.8)
.150
(5.1)
.201
(3.8)
.150
(12.7)
.500
4
5
6
6
(8.2)
.323
(3.8)
.150
(0.4) Typ
.016
(0.4) Typ
.016
(13.2)
.520
(6.2)
.245
(1.2)
.047
(12.7)
.500
(5.7)
.224
(13.2)
.520
MS22BSG30
(11.4)
.449
(3.2)
.126
(0.5)
.020
1
2
(1.27) Typ
.050
(3.81)
.150
(1.8) Dia Typ
.073
(4.7) Typ
.185
5
4
2
3
(3.81)
.150
1
(12.7)
.500
3
(0.8) Typ
.031
(4.7) Typ
.185
(1.5) Dia Typ
.059
(6.6) Typ
.260
Actuator in LEFT Position
Vertical PC Terminals
Single Pole
(5.1)
.201
(1.8) Dia Typ
.073
3
ON
3
(12.7)
.500
2
(6.9)
.270
ON
(3.8) Sq
.150
(3.81) Typ
.150
2
1
1
(10.16)
.400
(1.2) Typ
.047
(4.45)
.175
(0.4)
.016
(10.16)
.400
(5.3)
.209
MS12ASG40
(0.8) Typ (2.7)
.031
.106
(3.81) Typ
.150
(4.45) Typ
.175
(1.5) Dia Typ
.059
Actuator in LEFT Position
Vertical PC Terminals
Double Pole
(8.2)
.323
(5.1)
.201
(11.4)
.449
ON
(3.8)
.150
(1.2) Typ
.047
(4.45)
.175
(1.2) Typ
.047
(4.45)
.175
(6.9)
.270
ON
(3.8)
.150
MS22BSG40
(6.6)
.260
(1.27)
.050
(0.5)
.020
(5.3)
.209
(0.4)
.016
(12.7)
.500
(0.8) Typ (2.7)
.031
.106
(3.81) Typ
.150
(0.5)
.020
6
3
5
2
4
1
3
(12.7)
.500
(1.8) Dia Typ
.073
(4.8)
.189
6
2
5
1
4
(12.7)
.500
(1.27) Typ
.050
(4.8)
.189
(3.81) Typ
.150
(4.45) Typ
.175
(1.5) Dia Typ
.059
Actuator in LEFT Position
NKK Switches • email: [email protected] • Phone (480) 991-0942 • Fax (480) 998-1435 • www.nkkswitches.com