DELTA NC12S0A0H30NRFA

FEATURES
High Efficiency:
94% @ 12Vin, 5V/30A out
Voltage and resistor-based trim
No minimum load required
Output voltage programmable from
0.9Vdc to 5.0Vdc via external resistors
Fixed frequency operation
Input UVLO, output OVP, OTP, OCP, SCP
Remote ON/OFF (default: positive)
Power good output signal
Output voltage sense
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS 18001 certified manufacturing
facility
UL/cUL 60950 (US & Canada) Recognized,
and TUV (EN60950) Certified
CE mark meets 73/23/EEC and 93/68/EEC
directives
Delphi NC30 Series Non-Isolated Point of Load
DC/DC Power Modules: 12Vin, 0.9V-5Vout, 30A
The Delphi NC30 Series, 12V input, single output, non-isolated point of
load DC/DC converters are the latest offering from a world leader in
power systems technology and manufacturing ― Delta Electronics,
Inc. The NC30 series operates from a 12V nominal input, provides up
to 30A of power in a vertical or horizontal mounted through-hole
package and the output can be resistor- or voltage-trimmed from
0.9Vdc to 5.0Vdc. NC30 series has built-in current sharing control and
multiple NC30/NC40 series modules could be paralleled together to
provide even higher output currents. NC30 series provides a very cost
effective point of load solution. With creative design technology and
optimization of component placement, these converters possess
outstanding electrical and thermal performance, as well as extremely
high reliability under highly stressful operating conditions.
OPTIONS
Vertical or horizontal versions
Negative On/Off logic
APPLICATIONS
DataCom
Distributed power architectures
Servers and workstations
LAN/WAN applications
Data processing applications
DATASHEET
DS_NC12S30A_02072007
TECHNICAL SPECIFICATIONS
(TA=25°C, airflow rate=400LFM, Vin=12Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
NC12S0A0V30
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Operating Temperature
Storage Temperature
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
No-Load Input Current
Off Converter Input Current
Input Reflected-Ripple Current
Input Voltage Ripple Rejection
OUTPUT CHARACTERISTICS
Output Voltage Adjustment Range
Output Voltage Set Point
Output Voltage Regulation
Over Load
Over Line
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Output Current Range
Output Voltage Over-shoot at Start-up
Output Voltage Under-shoot at Power-Off
Output DC Current-Limit Inception
Output Short-Circuit Current (Hiccup mode)
DYNAMIC CHARACTERISTICS
Out Dynamic Load Response
Positive Step Change in Output Current
Negative Step Change in Output Current
Setting Time
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Minimum Output Startup Capacitive Load
Maximum Output Startup Capacitive Load
Minimum Input Capacitance
EFFICIENCY
Vo=0.9V
Vo=1.2V
Vo=1.5V
Vo=1.8V
Vo=2.5V
Vo=3.3V
Vo=5.0V
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control
Logic High
Logic Low
Remote Sense Range
GENERAL SPECIFICATIONS
MTBF
Weight
Over-Temperature Shutdown
DS_NC12S30A_02072007
Refer to Figure 36 for the measuring point
Non-isolated
Typ.
0
-40
Max.
Units
14
50
125
Vdc
°C
°C
V
13.8
V
NA
10.2
12
9.0
8.3
0.7
100% Load, 10.2Vin, 5Vout
15.6
160
10
150
55
Refer to Figure 35
120 Hz
Vin=12V, Io=Io,max, Ta=25℃, 1% trim resistors
Io=Io,min to Io,max
Vin=Vin,min to Vin,max
5Hz to 20MHz bandwidth
Full Load, 1µF ceramic, 10µF tantalum
Full Load, 1µF ceramic, 10µF tantalum
0.9
-3.0
5.0
+3.0
V
%
-1.0
-0.2
+1.0
+0.2
%
%
0
50
15
30
1
100
mV
mV
A
%
mV
A
A
Vin=12V, Turn ON
Vin=12V, Turn OFF
36
36
12Vin, 10µF Tan & 1µF Ceramic load cap, 10A/µs
50% Io,max to 75% Io,max
75% Io,max to 50% Io,max
Settling to be within regulation band (+/- 3.0%)
Io=Io.max
Vin=12V, Vo=10% of Vo,set, Ta=25℃
Vo=10% of Vo,set, Ta=25℃
Ex: Two OSCON 6.3V/680µF (ESR 13mΩ max each)
Full load; ESR ≧10mΩ
Ex: OSCON 16V/270µF (ESR 18mΩ max)
75
75
Auto restart, refer to Fig. 36&41 for the measuring point
150
mV
mV
µs
10
30
ms
ms
5440
µF
µF
1360
270
Vin=12V, Io=30A
Vin=12V, Io=30A
Vin=12V, Io=30A
Vin=12V, Io=30A
Vin=12V, Io=30A
Vin=12V, Io=30A
Vin=12V, Io=30A
Positive logic (internally pulled high)
Module On (or leave the pin open)
Module Off
V
V
V
A
mA
mA
mA
dB
78
82
85
87
90
92
94
%
%
%
%
%
%
%
300
KHz
2.4
-0.2
Vin,max
0.8
0.4
1.69
36
130
V
V
V
M hours
grams
°C
2
100
100
90
90
80
80
70
70
Efficiency (%)
Efficiency (%)
ELECTRICAL CHARACTERISTICS CURVES
60
50
40
30
20
10.2
10
12
60
50
40
30
20
13.8
10.2
10
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
0
2
4
6
8
Output Current (A)
Figure 2: Converter efficiency vs. output current
(1.2V output voltage)
100
90
90
80
80
70
70
Efficiency (%)
100
60
50
40
30
20
10.2
10
12
10 12 14 16 18 20 22 24 26 28 30
Output Current (A)
Figure 1: Converter efficiency vs. output current
(0.9V output voltage)
Efficiency (%)
13.8
0
0
60
50
40
30
20
13.8
10.2
10
0
12
13.8
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
0
2
4
6
8
Output Current (A)
Figure 4: Converter efficiency vs. output current
(1.8V output voltage)
100
90
90
80
80
70
70
Efficiency (%)
100
60
50
40
30
20
10.2
10
12
10 12 14 16 18 20 22 24 26 28 30
Output Current (A)
Figure 3: Converter efficiency vs. output current
(1.5V output voltage)
Efficiency (%)
12
13.8
60
50
40
30
20
10.2
10
12
13.8
0
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
Output Current (A)
Figure 5: Converter efficiency vs. output current
(2.5V output voltage)
DS_NC12S30A_02072007
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
Output Current (A)
Figure 6: Converter efficiency vs. output current
(3.3V output voltage)
3
ELECTRICAL CHARACTERISTICS CURVES (CON.)
120
Efficiency (%)
100
80
60
40
20
10.2
12
13.8
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30
Output Current (A)
Figure 7: Converter efficiency vs. output current
(5.0V output voltage)
Figure 8: Output ripple & noise at 12Vin, 0.9V/30A out
Figure 9: Output ripple & noise at 12Vin, 1.2V/30A out
Figure 10: Output ripple & noise at 12Vin, 1.5V/30A out
Figure 11: Output ripple & noise at 12Vin, 1.8V/30A out
Figure 12: Output ripple & noise at 12Vin, 2.5V/30A out
DS_NC12S30A_02072007
4
ELECTRICAL CHARACTERISTICS CURVES (CON.)
Figure 13: Output ripple & noise at 12Vin, 3.3V/30A out
Figure 14: Output ripple & noise at 12Vin, 5.0V/30A out
Figure 15: Turn on delay time at Vin On/Off, 0.9V/30A out
Ch2:Vin Ch3:Vout Ch4:PWRGD
Figure 16:Turn on delay time at Remote On/Off, 0.9V/30A out
Ch2:ENABLE Ch3:Vout Ch4:PWRGD
Figure 17: Turn on delay time at 12vin, 5.0V/30A out
Ch2:Vin Ch3:Vout Ch4:PWRGD
Figure 18: Turn on delay time at Remote On/Off, 5.0V/30A out
Ch2: ENABLE Ch3:Vout Ch4:PWRGD
DS_NC12S30A_02072007
5
ELECTRICAL CHARACTERISTICS CURVES (CON.)
Figure 19: Typical transient response to step load change at
10A/µS from 75% to 50% of Io, max at 12Vin, 1.2V out (Cout =
1uF ceramic, 10µF tantalum)
Figure 20: Typical transient response to step load change at
10A/µS from 75% to 50% of Io, max at 12Vin, 1.5V out (Cout =
1uF ceramic, 10µF tantalum)
Figure 21: Typical transient response to step load change at
10A/µS from 75% to 50% of Io, max at 12Vin, 1.8V out (Cout =
1uF ceramic, 10µF tantalum)
Figure 22: Typical transient response to step load change at
10A/µS from 75% to 50% of Io, max at 12Vin, 2.5V out (Cout =
1uF ceramic, 10µF tantalum)
Figure 23: Typical transient response to step load change at
10A/µS from 75% to 50% of Io, max at 12Vin, 3.3V out (Cout =
1uF ceramic, 10µF tantalum)
Figure 24: Typical transient response to step load change at
10A/µS from 75% to 50% of Io, max at 12Vin, 5.0V out (Cout =
1uF ceramic, 10µF tantalum)
DS_NC12S30A_02072007
6
DESIGN CONSIDERATIONS
The NC30 is designed using two-phase synchronous
buck topology. Block diagram of the converter is shown in
Figure 25. The output can be trimmed in the range of
0.9Vdc to 5.0Vdc by a resistor from trim pin to ground. A
remote sense function is provided and it is able to
compensate for a drop from the output of converter to
point of load.
The converter can be turned ON/OFF by remote control.
Positive on/off (ENABLE pin) logic implies that the
converter DC output is enabled when this signal is driven
high (greater than 2.4V) or floating and disabled when the
signal is driven low (below 0.8V). Negative on/off logic is
optional and could also be ordered.
The converter provides an open collector signal called
Power Good. The power good signal is pulled low when
output is not within ±10% of Vout or Enable is OFF.
The converter can protect itself by entering hiccup mode
against over current and short circuit condition. Also, the
converter will shut down when an over voltage protection
is detected.
FEATURES DESCRIPTIONS
ENABLE (On/Off)
The ENABLE (on/off) input allows external circuitry to put
the NC converter into a low power dissipation (sleep) mode.
Positive (active-high) ENABLE is available as standard.
Positive ENABLE (active-high) units of the NC series are
turned on if the ENABLE pin is high or floating. Pulling the
pin low will turn off the unit. With the active high function,
the output is guaranteed to turn on if the ENABLE pin is
driven above 2.4V. The output will turn off if the ENABLE
pin voltage is pulled below .8V.
The ENABLE input can be driven in a variety of ways as
shown in Figures 26, 27 and 28. If the ENABLE signal
comes from the primary side of the circuit, the ENABLE can
be driven through either a bipolar signal transistor (Figure
26) or a logic gate (Figure 27). If the enable signal comes
from the secondary side, then an opto-coupler or other
isolation devices must be used to bring the signal across
the voltage isolation (please see Figure 28).
NC30/NC40
Vin
The converter has an over temperature protection which
can protect itself by shutting down for an over
temperature event. There is a thermal hysteresis of
typically 30℃
Vout
Enable
Trim
Ground
Ground
Figure 26: Enable Input drive circuit for NC series
5V
NC30/NC40
Vin
Vout
Enable
Trim
Ground
Ground
Figure 27: Enable input drive circuit using logic gate.
Figure 25: Block Diagram
NC30/NC40
Vin
Safety Considerations
It is recommended that the user to provide two 12A very
fast-acting type fuses (Little fuse R451 012) in parallel in
the input line for safety.
Enable
Ground
Vout
Trim
Ground
Figure 28: Enable input drive circuit example with isolation.
DS_NC12S30A_02072007
7
FEATURES DESCRIPTIONS (CON.)
Over Temperature Protection (OTP)
Input Under-Voltage Lockout
To provide additional over-temperature protection in a
fault condition, the unit is equipped with a non-latching
thermal shutdown circuit. The shutdown circuit engages
when the temperature of monitored component exceeds
approximately 130℃. The unit will cycle on and off while
the fault condition exists. The unit will recover from
shutdown when the cause of the over temperature
condition is removed.
The input under-voltage lockout prevents the converter
from being damaged while operating when the input
voltage is too low. The lockout occurs between 7.7V to
8.6V.
Over-Current and Short-Circuit Protection
The NC series modules have non-latching over-current
and short-circuit protection circuitry. When over current
condition occurs, the module goes into the non-latching
hiccup mode. When the over-current condition is
removed, the module will resume normal operation.
An over current condition is detected by measuring the
voltage drop across the high-side MOSFET. The voltage
drop across the MOSFET is also a function of the
MOSFET’s Rds(on). Rds(on) is affected by temperature,
therefore ambient temperature will affect the current limit
inception point.
The unit will not be damaged in an over current condition
because it will be protected by the over temperature
protection.
Remote Sense
Over Voltage Protection (OVP)
The converter will shut down when an output over voltage
is detected. Once the OVP condition is detected, the
controller will stop all PWM outputs and will turn on
low-side MOSFET driver to prevent any damage to load.
Current Sharing (optional)
The parallel operation of multiple converters is available
with the NC30/NC40 (option code B). The converters will
current share to be within +/- 10% of each other. In
addition to connect the I-Share pin together for the current
sharing operation, the remote sense lines of the
paralleled units must be connected at the same point for
proper operation. Also, units are intended to be turned
on/enabled at the same time. Hot plugging is not
recommended. The current sharing diagram show in
Figure 30.
The NC30/NC40 provide Vo remote sensing to achieve
proper regulation at the load points and reduce effects
of distribution losses on output line. In the event of an
open remote sense line, the module shall maintain local
sense regulation through an internal resistor. The
module shall correct for a total of 0.4V of loss. The
remote sense connects as shown in Figures 29.
NC30A/40A
Vout
+SENSE
Cout
-SENSE
GROUND
I-SHARE
o
VIN
Vo
+SENSE
o
LOAD
TRIM
NC30A/40A
0
GROUND
Vout
+SENSE
Rload
Cout
-SENSE
-SENSE
GROUND
GROUND
Contact and Distribution
Losses
I-SHARE
TRIM
Figure 29: Circuit configuration for remote sense
0
Figure 30: NC30/NC40 Current Sharing Diagram
DS_NC12S30A_02072007
D
S_NC12S30A_02072007
8
FEATURES DESCRIPTIONS (CON.)
To use voltage trim, the trim equation for the NC30 is (please
refer to Fig. 33) :
Output Voltage Programming
The output voltage of the NC series is trimmable by
connecting an external resistor between the trim pin and
output ground as shown Figure 31 and the typical trim
resistor values are shown in Figure 32. The output can
also be set by an external voltage connected to trim pin as
shown in Figure 32.
The NC30A/40A module has a trim range of 0.9V to
5.0V. A plot of trim behavior is shown in Figure 33
Cout
GROUND
-SENSE
Vout is the desired output voltage
Vt is the external trim voltage
Rs is the resistance between Trim and Ground (in KΩ)
Rt is the resistor to be defined with the trim voltage (in KΩ)
Below is an example about using this voltage trim equation :
If Vt = 1.25V, desired Vout = 2.5V and Rs = 1 kΩ
Rt (kΩ) =
Rs
TRIM
Rs(13.1Vt + Vout − 12.69)
= 0.72kΩ
0.9 Rs − Vout ( Rs + 1) + 12.69
Power Good
Figure 31: Trimming Output Voltage
The NC30/NC40 modules have a trim range of 0.9V to
5.0V. The trim resistor equation for the them is :
12.69 − Vout
Vout − 0.9
Vout is the desired voltage setpoint,
Rs is the trim resistance between TRIM and Ground,
Rs values should not be less than 1.8 kΩ
Output Voltage
+0.9 V
+1.2 V
+1.5 V
+1.8 V
+2.5 V
+3.3 V
+5.0 V
Rs (13.1Vt + Vout − 12.69)
0.9 Rs − Vout ( Rs + 1) + 12.69
Example:
+SENSE
Vout
Rs (kΩ) =
Rt (kΩ) =
Rs(Ω)
OPEN
38.3K
18.7K
12.1K
6.34K
3.92K
1.87K
The converter provides an open collector signal called Power
Good. This output pin uses positive logic and is open
collector. This power good output is able to sink 5mA and set
high when the output is within ±10% of output set point. The
power good signal is pulled low when output is not within
±10% of Vout or Enable is OFF.
Output Capacitance
There is no output capacitor on the NC series modules.
Hence, an external output capacitor is required for stable
operation. For NC30 modules, two external 6.3V/680µF
output low ESR capacitors in parallel (for example, OSCON)
are required for stable operation.
It is important to places these low ESR capacitors as close to
the load as possible in order to get improved dynamic
response and better voltage regulation, especially when the
load current is large. Several of these low ESR capacitors
could be used together to further lower the ESR.
Figure 32: Typical trim resistor values
Please refer to individual datasheet for the maximum allowed
start-up load capacitance for each NC series as it is varied
between series.
+SENSE
Vout
Cout
GROUND
-SENSE
Rs
TRIM
Vt
Rt
Figure 33: Output voltage trim with voltage source
DS_NC12S30A_02072007
9
FEATURES DESCRIPTIONS (CON.)
THERMAL CONSIDERATION
Voltage Margining
Thermal management is an important part of the
system design. To ensure proper, reliable operation,
sufficient cooling of the power module is needed over
the entire temperature range of the module. Convection
cooling is usually the dominant mode of heat transfer.
Output voltage margining can be implemented in the
NC30/NC40 modules by connecting a resistor, R margin-up,
from the Trim pin to the ground pin for margining up the
output voltage. Also, the output voltage can be adjusted
lower by connecting a resistor, Rmargin-down, from the Trim
pin to the output pin. Figure 34 shows the circuit
configuration for output voltage margining adjustment.
Vt
+SENSE
Vout
Rmargin-down
Cout
GROUND
-SENSE
Rs
TRIM
Rmargin-up
0
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in
which the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the wind
tunnel.
Figure 34: Circuit configuration for output voltage margining
Thermal Derating
Reflected Ripple Current and Output Ripple and
Noise Measurement
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power
module should always be operated below the
maximum operating temperature. If the temperature
exceeds the maximum module temperature, reliability
of the unit may be affected.
The measurement set-up outlined in Figure 35 has been
used for both input reflected/ terminal ripple current and
output voltage ripple and noise measurements on NC
series converters.
The maximum acceptable temperature measured at
the thermal reference point is 125℃. This is shown in
Figure 36 & 41.
Cs=270uF*1 Ltest=1.4uH Cin=270uF*1 Cout=680uF*2
Figure 35: Input reflected ripple/ capacitor ripple current and
output voltage ripple and noise measurement setup for NC30
DS_NC12S30A_02072007
10
THERMAL CURVES (NC12S0A0V30)
NC12S0A0V30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout = 3.3V(Either Orientation)
Test Section for NC12S0A0V30
35
Output Current(A)
PWB
FACING PWB
30
MODULE
25
20
Natural
Convection
100LFM
15
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
200LFM
300LFM
10
50.8 (2.0”)
5
AIR FLOW
0
25
19 (0.75”)
38 (1.5”)
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 38: Output current vs. ambient temperature and air
velocity@ Vout=3.3V(Either Orientation)
Note: Wind Tunnel Test Setup Figure Dimensions are in
millimeters and (Inches)
NC12S0A0V30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout = 1.5V(Either Orientation)
35
Output Current(A)
30
25
Natural
Convection
20
100LFM
15
200LFM
300LFM
10
5
0
25
Figure 36: Temperature measurement location
* The allowed maximum hot spot temperature is defined at 125℃
35
30
30
25
25
Natural
Convection
65
75
85
Ambient Temperature (℃)
Output Current(A)
Natural
Convection
20
100LFM
100LFM
15
15
55
NC12S0A0V30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout = 0.9V(Either Orientation)
Output Current(A)
20
45
Figure 39: Output current vs. ambient temperature and air
velocity@ Vout=1.5V(Either Orientation)
NC12S0A0V30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout = 5V(Either Orientation)
35
35
200LFM
200LFM
300LFM
10
10
400LFM
5
5
0
0
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 37: Output current vs. ambient temperature and air
velocity@ Vout=5V(Either Orientation)
DS_NC12S30A_02072007
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 40: Output current vs. ambient temperature and air
velocity@ Vout=0.9V(Either Orientation)
11
THERMAL CURVES (NC12S0A0H30)
Test Section for NC12S0A0H30
35
NC12S0A0H30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout = 3.3V(Either Orientation)
Output Current(A)
PWB
FACING PWB
30
MODULE
25
20
Natural
Convection
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
15
100LFM
200LFM
50.8 (2.0”)
10
300LFM
400LFM
AIR FLOW
5
0
9.5 (0.38”)
19 (0.75”)
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 43: Output current vs. ambient temperature and air
Note: Wind Tunnel Test Setup Figure Dimensions are in
millimeters and (Inches)
velocity@ Vout=3.3V(Either Orientation)
35
NC12S0A0H30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout =1. 5V(Either Orientation)
Output Current(A)
30
25
20
Natural
Convection
15
100LFM
200LFM
10
300LFM
5
0
Figure 41: Temperature measurement location
* The allowed maximum hot spot temperature is defined at 125℃
35
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 44: Output current vs. ambient temperature and air
velocity@ Vout=1.5V(Either Orientation)
NC12S0A0H30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout = 5V(Either Orientation)
Output Current(A)
35
NC12S0A0H30(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vout = 0.9V(Either Orientation)
Output Current(A)
30
30
25
25
20
Natural
Convection
20
15
Natural
Convection
100LFM
15
200LFM
100LFM
10
300LFM
200LFM
10
400LFM
5
300LFM
500LFM
5
0
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 42: Output current vs. ambient temperature and air
velocity@ Vout=5V(Either Orientation)
DS_NC12S30A_02072007
0
25
35
45
55
65
75
85
Ambient Temperature (℃)
Figure 45: Output current vs. ambient temperature and air
velocity@ Vout=0.9V(Either Orientation)
12
MECHANICAL DRAWING
VERTICAL
DS_NC12S30A_02072007
HORIZONTAL
13
Part Numbering System
NC
12
S
0A0
V
30
P
N
Product
Series
Input
Voltage
Number of
outputs
Output
Voltage
Mounting
Output
Current
ON/OFF
Logic
Pin Length
NC-
12-
Non-isolated 10.2~13.8V
S- Single
0A0-
output
programmable V- Vertical
H- Horizontal
30- 30A P- Positive
N- Negative
F
A
Option Code
R- 0.118”
F- RoHS 6/6
N- 0.140”
(Lead Free)
A- Standard
Functions
Converter
MODEL LIST
Model Name
Output Current
Efficiency
12Vin @ 100% load
Packaging
Input Voltage
Output Voltage
NC12S0A0V30PNFA
Vertical
10.2 ~ 13.8Vdc
0.9 V ~ 5.0Vdc
30A
94% (5.0V)
NC12S0A0H30PNFA
Horizontal
10.2 ~ 13.8Vdc
0.9 V ~ 5.0Vdc
30A
94% (5.0V)
CONTACT: www.delta.com.tw/dcdc
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email: [email protected]
Europe:
Telephone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107 x6220
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta
for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license
is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these
specifications at any time, without notice.
DS_NC12S30A_02072007
14