TECHNICAL DATA SHEET NL1013T Single-Stage Thermoelectric Module RoHS EU Compliant TYPICAL PERFORMANCE VALUES Hot Side Temperature (°C) ∆ Tmax (°C-dry Vac): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): Device ZT 27°C 61 4.8 1.0 8.5 7.42 0.77 50°C 69 5.4 1.0 9.6 --- MECHANICAL CHARACTERISTICS (+) * Leads: 28 AWG, Buss, Solid Tinned Copper .518 [13.16] (-) * 2.00 +/-.25 [50.80+/-6.35] .518 [13.16] .095+/-.005 [2.41 +/-0.13] Cold Side, Tc * .005 [0.13] A .001 [0.03] .001 [0.03] * Hot Side, Th Ceramic Material: Alumina (AC) Millimeters are in [ ] A -01AC, -02AC, -03AC *NOTE: Cold side, hot side, positive leads, and negative leads are valid only for thermoelectric cooling. For power generation, refer to page 4. ORDERING OPTIONS PRODUCT FEATURES Model Number Description NL1013T-01AC NL1013T-02AC NL1013T-03AC TEM, Top and Base Metallized Exterior TEM, Base Metallized Exterior TEM, No Metallized Exterior TEM, No Metallized Exterior, Sealed, Special Wires NL1013T-04AC Maximum operating temperature is 85°C. Maximum process temperature is 220°C. Ceramic Material: Aluminum Oxide Metallized Exterior Surfaces are Au flash, suitable for soldering. RTV Sealing options available. For customer support or general questions please contact a local office or visit our website at www.marlow.com. DOC # 102-0292 REV J - PAGE 1 OF 4 TECHNICAL DATA SHEET *NOTE: Cold side, hot side, positive leads, and negative leads are valid only for thermoelectric cooling. For power generation, refer to page 4. DOC # 102-0292 REV J - PAGE 2 OF 4 ENVIRONMENT: 10^-5 TORR VACUUM 20 0 8 6 4 2 0 0.0 Q=0 T=0 0.2 0.4 0.6 0.8 CURRENT (AMPS) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 60 T (C) 40 HEAT LOAD (WATTS) 80 40 20 0 VOLTAGE (VDC) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 60 T (C) Hot Side Temperature: 50°C HEAT LOAD (WATTS) 80 VOLTAGE (VDC) TYPICAL PERFORMANCE CURVES Hot Side Temperature: 27°C 1.0 8 6 4 Q=0 T=0 2 0 0.0 0.2 0.4 0.6 0.8 CURRENT (AMPS) 1.0 For performance information in nitrogen or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691. • Marlow reserves the right to make product changes without notice. Installation Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide. Operation Cautions For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method. CONTACT US: For customer support or general questions please contact a local office below or visit our website at www.marlow.com. Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 214-340-4900 (tel) 214-341-5212 (fax) 877-627-5691 (tech support) www.marlow.com Marlow Industries Europe GmbH Brunnenweg 19-21 64331 Weiterstadt Germany Tel.: +49 (0) 6150 5439 - 403 Fax: +49 (0) 6150 5439 - 400 [email protected] II-VI Japan Inc. WBG Marive East 17F 2-6 Nakase, Mihama-ku Chiba-Shi, Chiba 261-7117 Japan 81 43 297 2693 (tel) 81 43 297 3003 (fax) [email protected] www.ii-vi.co.jp II-VI Singapore Pte., Ltd. Blk. 5012, Techplace II #04-07 & 05-07/12, Ang Mo Kio Ave. 5 Singapore 569876 (65) 6481 8215 (tel) (65) 6481 8702 (fax) [email protected] www.ii-vi.com.sg Marlow Industries China, II-VI Technologies Beijing A subsidiary of II-VI Incorporated Rm 202, 1# Lize 2nd Middle Road Wangjing, Chaoyang District Beijing 100102 China 010-64398226 ext 105 (tel) 010-64399315 (fax) [email protected] DOC # 102-0292 REV J - PAGE 3 OF 4 Hot Side Temperature (°C) Hot Side Temperature (°C) 45 50 55 65 75 55 85 Tc=27°C 0.4 0.2 Power 1.2 1.7 2.2 Heat (W) 2.7 70 75 80 85 0.6 Tc=50°C 0.03 0.5 0.025 0.4 0.02 0.3 0.015 0.2 0.01 0.1 0.005 Voltage Power Voltage 0 0 0 0.7 Opt Power (W) 0.6 65 0.7 0.035 1 0.8 60 0.04 1.2 0.3 3.2 Opt Voltage (V) 40 Opt Voltage (V) Opt Power (W) 35 0.2 0.5 0.7 0.9 1.1 1.3 Heat (W) 1.5 1.7 1.9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Efficiency 0 1 2 3 4 5 6 7 Load Resistance Ratio 8 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 Voltage 0.1 0 9 10 Voltage / VOC Normalized Off-Peak Performance η / Opt η TYPICAL PERFORMANCE CURVES 30 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 Hot Side Temperature (°C) Cold Side Temperature (°C) Optimum Efficiency, η (%) Optimum Power (W) Optimum Voltage (V) Load Resistance for Opt η (Ω) Open Circuit Voltage, VOC (V) Short Circuit Current (A) Thermal Resistance (°C/W) 85 27 2.52 0.087 1.021 12.00 1.79 0.20 16.86 55 27 1.28 0.021 0.487 11.20 0.85 0.10 16.88 35 27 0.37 0.002 0.138 10.65 0.24 0.03 16.85 Power Generation performance information is given in a nitrogen environment and cold side temperatures of 27°C and 50°C. Module temperature does not include thermal resistance of heat sinks. For performance information in vacuum, other cold side temperatures, or specific heat sinks, consult one of our applications engineers. TYPICAL POWER GENERATION CONFIGURATION EXAMPLE: (-) (+) Hot Side, Th Cold Side, Tc DOC # 102-0292 REV J - PAGE 4 OF 4