CANDD NMR102 Isolated 1w single output dc-dc converter Datasheet

NMR SERIES
Isolated 1W Single Output DC-DC Converters
SELECTION GUIDE
FEATURES
■ Wide Temperature Performance at
Full 1 Watt Load, –40°C to 85°C
■ Industry Standard Pinout
Nominal
Input
Voltage
Output
Voltage
Output
Current
Input Current
at Rated Load
Order Code
(V)
(V)
(mA)
(mA)
(%)
(pF)
kHrs
NMR100
5
5
200
290
69
28
1322
NMR101
5
12
83
260
77
33
235
NMR102
5
15
67
253
79
40
127
NMR106
12
5
200
121
69
36
515
NMR107
12
12
83
110
76
58
184
NMR108
12
15
67
110
76
56
111
MTTF1
■ 1kVDC Isolation
■ Efficiency to 79%
■ Power Density up to 0.90W/cm3
■ 5V & 12V Input
■ 5V, 12V & 15V Output
■ Footprint of 1.17cm 2
■ UL 94V-0 Package Material
When operated with additional external load capacitance the rise time of the input voltage will determine the
maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the
greater the maximum value of the additional external capacitance for reliable start up.
■ No Heatsink Required
■ Internal SMD Construction
INPUT CHARACTERISTICS
■ Toroidal Magnetics
Parameter
■ Fully Encapsulated
■ No External Components Required
Conditions
Voltage Range Continuous operation, 5V input types
Continuous operation, 12V input types
Reflected Ripple Current
MIN
TYP
MAX
4.5
10.8
5
12
40
5.5
13.2
60
Units
mA p-p
TYP
MAX
Units
1.0
W
1.2
13.4
7.7
7.5
50
%/%
V
■ MTTF up to 1.6 Million Hours
■ Custom Solutions Available
OUTPUT CHARACTERISTICS
■ No Electrolytic or Tantalum
Capacitors
Parameter
Conditions
Rated Power2
Voltage Set
Point Accuracy
Line Regulation
TA= –40°C to 85°C
DESCRIPTION
The NMR series of industrial temperature
range DC-DC converters are the standard
building blocks for on-board distributed
power systems. They are ideally suited for
providing single rail supplies on primarily
digital boards with the added benefit of
galvanic isolation to reduce switching noise.
Surface mount technology and advanced
packaging materials produce rugged reliable
performance over an extended temperature
range from –40°C to 85°C.
www.dc-dc.com
MIN
See tolerance envelope
High V IN to low V IN
10% load to rated load, 5V output types
Load Regulation 10% load to rated load, 12V output types
10% load to rated load, 15V output types
Ripple & Noise BW=DC to 20MHz
1.0
12.5
6.9
6.5
30
%
mV p-p
ABSOLUTE MAXIMUM RATINGS
Short-circuit duration 3
Internal power dissipation
Lead temperature 1.5mm from case for 10 seconds
Input voltage V IN , NME05 types
Input voltage V IN , NME12 types
1 second
550mW
300°C
7V
15V
1 Calculated using MIL-HDBK-217F with nominal input voltage at full load.
2 See derating curve
3 Supply voltage must be discontinued at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
NMR SERIES
Isolated 1W Single Output DC-DC Converters
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation Test Voltage
Resistance
Flash tested for 1 second
Viso=1000VDC
MIN
TYP
MAX
Units
1000
VDC
GΩ
10
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching Frequency
5V input types
12V input types
MIN
TYP
MAX
Units
110
160
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
MIN
Specification
Storage
Case Temperature
Above Ambient
Cooling
All output types
-40
-50
5V output types
All other output types
Free air convection
TYP
MAX
Units
85
130
°C
°C
33
28
°C
PERFORMANCE CHARACTERISTICS
tolerance envelope
2.0
+10%
+5%
+2.5%
V nominal
temperature derating graph
1.5
-2.5%
1.0
-7.5%
0.5
10
50
Output Load Current (%)
Safe Operating Area
0
100
-40
0
50
100
Ambient Temperature (°C)
150
MECHANICAL DIMENSIONS
7 Pin SIP
19.50
1.88±0.50
NMR100
6.00
10.0
PIN
1
VIN
2 GND
4
0V
6
+V
4.60
3.60
1.25
XYYWWi
1 2
4
2.54
0.55
0.45
0.30
0.20
12.70
6
0.55
0.45
Weight: 2.1g
All dimensions in mm XX.XX ±0.25mm. All pins on a 2.54mm pitch and within ±0.25mm of true position.
C&D Technologies (NCL) Limited reserve the right to alter or improve the
specification, internal design or manufacturing process at any time, without
notice. Please check with your supplier or visit our web site to ensure that
you have the current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2001
NDC NMR.3
No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to,
photography, photocopy, magnetic or other recording means, without prior
written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.dc-dc.com
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, England
Tel: +44 (0)1908 615232
Fax:+44 (0)1908 617545
email: [email protected]
www: http://www.dc-dc.com
C&D Technologies (NCL), Inc.
5816 Creedmoor Road, Raleigh
NC 27612, USA
Tel: +1 (919) 571-9405
Fax: +1 (919) 571-9262
email: [email protected]