DB LECTRO INC NT90TP(T92) E9930952 CH0050401-2000 E174722 R2033977.07 LR956331 32.4(50)×27×28.5 Features n n Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. Suitable for automobile, machine, electronic equipment, air conditioner and household appliance applications. Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1A, 1B, 1C Ag CdO Ag SnO2 Ag SnO2 In 2O3 NO:30A/240VAC,14VDC; NC:20A/240VAC ;30A/14VDC NO;40A/250VAC,28VDC; NC:30A/250VAC,28VDC (0.9W) 1100W 7200VA 110VDC 250VAC Max. Switching Current:40A 30mΩ Max Item 3.12 of IEC255-7 105 Item 3.30 of IEC255-7 107 Item 3.31 of IEC255-7 Coil Parameter DC Coil Parameter Coil voltage VDC Rated Max 3 5 6 9 12 15 18 24 48 110 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143 AC Coil Parameter Coil resistance Ω±10% Pick up voltageE VDC(max) (75%of rated voltage) Release voltage VDC(min) (10%of rated voltage) 10/15 28/42 40/60 90/135 160/240 250/375 360/540 640/960 2560/3840 13445/20167 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0 Coil power W 0.9/0.6 Operate Time ms Max 15 Release Time ms Max Rated voltage VAC Coil resistance Ω±10% 12 (27) 24 (120) 110 (2360) 120 (3040) 220 (13490) 10 CAUTION : 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil 1000MΩ min (at 500VDC) Item 7 of IEC255-5 50Hz 1500V 50Hz 2500V Item 6 of IEC255-5 Item 6 of IEC255-5 Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 200m/s 2 11ms 10~55Hz double amplitude 1.5mm 10N 230 ºC± 2 ºC 10± 0.5s -55~100 ºC -55~125 ºC 85% (at 40 ºC) 37g IEC68-2-27 Test Ea method 1 IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table IV of IEC255-19-1 and minimum sample size 24. 79 Coil power 2VA NT90TP(T92) Ordering Information NT90TP H A S DC12V C B 0.9 Coil power consumption:0.6:0.6W, 0.9:0.9W, 2:2VA Resist heat class :B:130 ºC, F:155ºC Contact material :Nil:AgžSnO2žIn2O3 , C:AgžCdO, S:AgžSnO2 Coil rated Voltage DC:3V, 5V, 6V, 9V, 12V, 15V, 18V, 24V, 48V, 110V AC:12V, 24V, 110V, 120V, 220V S:Sealed type, D:Dust Cover, E:Covered , O:Open type Contact Arrangement :A:1A, B:1B, C:1C H:30A, NL:40A, Heavy load Part number:NT90TP (T92) Dimensions (Unit: mm) mm 0.5 0.8 2.8 3.6 4.7 6.4 27 28.5 32.4 43.5 50 Dimensions inch 0.020 0.031 0.110 0.142 0.185 0.252 1.063 1.122 1.275 1.713 1.969 Wiring diagram NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. Reference Data DB LECTRO INC . 80