GPON High Power Diplexer PRELIMINARY ODP-34-PE Features • Low cost 1310 FP TX design, 1490 nm receive • High Isolation • -40 to 85˚C operation • Multiple TIA versions for 155, 622, and 1250 Mbps applications • Compliant to ITU-T G.GPON class c at 155Mbps and 622Mbps Tx • Compliant to ITU-T G.GPON class B at 1250 Mbps Absolute Maximum Ratings Parameter Operating Temperature(case) Storage Temperature Min -40 -40 Typical - Max 85 85 Units ºC ºC Typical - Max -47 -6 -20 -20 Units dB dB dB dB dB Module Requirements Parameter 1550 Enhancement Band to 1490 RX isolationa 1310 TX to 1490 RX crosstalk Back Reflection @ 1310 nm Back Reflection @ 1550 nm Back Reflection @ 1490 nm a With Min 29 - Enhancement Band block from 1535nm to 1565nm Transmitter Requirements Parameter Wavelength Spectral Width (RMS) 1/2 Ppeak set point @ 25ºC (GPON) 1/2 Ppeak over temp and EOL(GPON) Bias Current Bias Current@EOL Modulation Currentc PD Monitor Current Forward Voltage Rise/Fall Timeb PD Monitor Dark Current PD Monitor Capacitance b 10% c Symbol λ ∆λ Pset Pave Ibias Ibias,EOL Imod IPD,mon Vf tr/tf IPD, dark CPD Min 1260 -1 6 10 100 - to 90% Greater modulation current can be used for higher output powers Typical 2 2.5 1.2 10 Max 1360 3 4 70 100 60 1000 1.8 0.5 1 20 Units nm nm dBm dBm mA mA mA µA Volts ns µA pF GPON High Power Diplexer PRELIMINARY ODP-34-PE Digital Receiver Characteristics (155 Mbps) Parameter Detection Wavelength Gain differential Supply Voltage Supply Current (Vcc= 5V)a Supply Current (Vcc= 3.3V)a High Frequency -3 dB pointb Single-ended output voltage(p-p)c Single-ended output resistanced Units nm mV/µW V mA mA MHz mV Ohm Min 1260 20 3 20 20 100 40 36 Typical 5.0 38 35 130 110 44 Max 1360 5.5 60 50 200 57 Symbol λ G Vcc Icc Icc f-3dB(h) f-3dB(h) Vo(se)(p-p) Ro(se) Min 1260 10 3 23 20 450 440 75 40 Typical 5.0 28 28 580 520 200 50 Max 1360 5.5 45 42 750 600 330 62 Units nm mV/µW V mA mA MHz MHz mV Ohm Symbol λ G Vcc Icc f-3dB(h) f-3dB(h) Vo(se)(p-p) Ro(se) Min 1260 4 3 1000 850 75 40 Typical 5.0 34 1200 1100 200 50 Max 1360 5.5 47 330 62 Units nm mV/µW V mA MHz MHz mV Ohm Symbol λ G Vcc Icc Icc f-3dB(h) Vo(se)(p-p) Ro(se) a) AC Coupled; RL= 50 Ohm b) AC coupled; measured differentially; Ci =0.7 pF; RL =50 Ohm; Tj= 100ºC c) AC coupled; RL = 50 Ohm; input current =100 µA(p-p) d) DC tested Digital Receiver Characteristics (622 Mbps) Parameter Detection Wavelength Gain differential Supply Voltage Supply Current (Vcc= 5V)a Supply Current (Vcc= 3.3V)a High Frequency -3 dB point (Vcc= 5V)b High Frequency -3 dB point (Vcc= 3.3V)b Single -ended output voltage(p-p)c Single-ended output resistanced a) AC coupled; RL =50 Ohm b) Ci= 0.7 pF c) AC coupled; RL = 50 Ohm; input current =100 µA(p-p) d) DC tested Digital Receiver Characteristics (1250 Mbps) Parameter Detection Wavelength Gain differential Supply Voltage Supply Current a High Frequency -3 dB point (Vcc= 5V)b High Frequency -3 dB point (Vcc= 3.3V)b Single -ended output voltage(p-p)c Single-ended output resistanced a) AC coupled; RL =50 Ohm b) Ci= 0.7 pF c) AC coupled; RL = 50 Ohm; input current =100 µA(p-p) d) Single-ended; DC tested GPON High Power Diplexer PRELIMINARY ODP-34-PE Outline Drawing Receiver Block Diagram Vcc 10 µF + 1H 0.01 µF 1 4 C OUT - C OUT + 2 3 Luminent Optical block Customer Interface At 155 Mbps, C= 0.1µF At 622 Mbps, C= 0.1 µF At 1250 Mbps, C= 0.022 µF GPON High Power Diplexer PRELIMINARY ODP-34-PE Ordering Information Available Options: A ODP-34-PE--155x ODP-34-PE--622x ODP-34-PE--1250x Part numbering Definition: Min. ODP - 34 - Half Peak Output Power -- Digital TIA - Connector Type - Temperature Range - Customer Specific • (Separator) • Blank = No TIA 155 622 1250 xxxB (B=Burst) • PX PAA = -13 to -16dBm PA = -9 to -13 dBm PB = -6 to -9 dBm PC = -3 to -6 dBm PD = -1 to -3 dBm PE = -1 to +1 dBm PF = +1 and up • SCX LCX FCX STX X = A (angled) X = U (ultra) • Blank = Industrial (-40 to 85) C = Commercial (0 to 70ºC) R = Reduced Industrial (-20 to 85ºC) • Labelling, Serial Number, TIA, or shipping instructions etc. Warnings Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notice IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and Luminent makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. Luminent customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify Luminent for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © Luminent, Inc. 2002 All rights reserved Rev 0 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 • LUMINENT.COM LUMNDS411-0403