1 5 W U l t r a m i n i a t ure Open Frame Switching Power Supplies OFM15 Universal 85-265VAC Input High Efficiency Regulated Outputs 3000V Isolation Single and Dual Outputs UL60950-1, EN60950-1 & IEC60950-1 Approved 1.89”W x 2.76”L x 0.98”H Model Number Output Voltage Output Amps(max) (pk) SINGLE OUTPUT OFM-1500 OFM-1501 OFM-1502 OFM-1503 OFM-1505 3.3 VDC 5 VDC 12 VDC 15VDC 24VDC 3.5A 3A 1.25A 1A 0.63A 3.8A 3.6A 1.5A 1.25A 0.75A DUAL OUTPUT OFM-1506 OFM-1507 +/-12VDC +/-15VDC +/-0.63A +/-0.5A +/-0.8A +/-0.65A Order On-Line! astrodyne.com series OFM15/M 1 5 W U l t r a m i n i a t ure Medical Grade Switching Power Supplies series Universal 85-265VAC Input High Efficiency Regulated Outputs 4000V Isolation Single and Dual Outputs UL60601-1, EN60601-1, & IEC60601 Approved 1.89”W x 2.76”L x 0.98”H Model Number Output Voltage Output Amps(max) (pk) SINGLE OUTPUT OFM-1500/M OFM-1501/M OFM-1502/M OFM-1503/M OFM-1505/M 3.3 VDC 5 VDC 12 VDC 15VDC 24VDC 3.5A 3A 1.25A 1A 0.63A 3.8A 3.6A 1.5A 1.25A 0.75A DUAL OUTPUT OFM-1506/M OFM-1507/M +/-12VDC +/-15VDC +/-0.63A +/-0.5A +/-0.8A +/-0.65A Order On-Line! WWW.ASTRODYNE.COM astrodyne.com 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 1 5 W U l t r a m i n i a t ure Open Frame Switching Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: series GENERAL SPECIFICATIONS 85-265 VAC 47-440 Hz 20A@100V, 40A@200V Input * Input-Out Isolation I/P-Ground O/P-Ground Efficiency Switching Frequency See Selection Chart Singles: +/- 3%, Duals: +/- 3% Singles +/- 0.1~1%, typ Duals +/- 0.3~1%, typ 2% 1% +/- 6% of FS (Primary) +/-0.03%/°C 100mV Pk-Pk, typ Clamp, 130-150% * Latching, Cool and Repower Continuous, self-recovering 20 mS, typ PHYSICAL SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage and Current Load Regulation (20%-FL) Line Regulation Cross Regulation (Duals) Preset Accuracy DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise Over Voltage Protection Over Temp. Protection Short Circuit Protection Hold Up Time OFM15 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. Size Construction Weight 3KVAC, (4KVAC Medical) 2500VAC 1000VAC 75%~78%, typ 100Khz, (fixed, typical) 1.89” x 2.75” x 0.98” Open Frame 2.5oz (70g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity EMC MTBF 0 to +70°C (See Derate) -25 to +71°C * 0 to + 95%, non-cond * FCC/A, VDE 0871/A (Mil Std 217, 25°C) 559,000 Hrs Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. OFM15 1 5 W U l t r a m i n i a t ure Open Frame Switching Power Supplies OUTPUT DERATING CURVE 100 90 Load, % 80 70 60 50 40 30 20 0 10 20 30 40 50 60 70 Ambient Temperature, °C MECHANICAL DIMENSIONS .83 (21.0) .070 (1.78) .040 (1.02) .150 (3.81) (-) (-) (-) (-) (-) (-) C3 C2 D3 C5 9 D4 L2 C4 ACL 1 C6 F1 U2 .16 (4.00) 6 1.398 (35.51) B1 C9 .945 (24.00) .157 (4.00) L1 C8 DS1 T1 2 .945 (24.00) 8 U1 C7 1.89 (48.0) C11 ACN B2 .492 (12.50) 2.441 (62.00) 2.75 (69.9) Pin # Single Outputs Dual Outputs 1 2 6 8 9 AC Line AC Neutral + Output NC - Output AC Line AC Neutral +Output Common - Output series