ETC OM4004ST

OM4003ST OM4005ST OM4007ST
OM4004ST OM4006ST
10 AMP SCHOTTKY RECTIFIER IN SMALL
HERMETIC PACKAGE
10 Amp, 60 To 100 Volt Schottky Rectifiers
FEATURES
•
•
•
•
•
•
•
Small Size
Very Low Forward Voltage
Low Recovered Charge
Rugged Package Design
High Efficiency for Low Voltage Supplies
Hermetic and Isolated Package
Available Screened To MIL-S-19500, TX, TXV And S Levels
DESCRIPTION
This series of Schottky barrier diodes offers low forward voltage and high output current for
its small package size. The OM4003 series was designed for demanding applications
where small size, light weight and high reliability are required. These devices are
ideal replacements for TO-3, DO-4 or DO-5 packages. All products are available
Hi-Rel screened.
PIN CONNECTION
MECHANICAL OUTLINE
.200
.190
.420
.410
.045
.035
3.2
.665
.645
.150
.140
.537
.527
.430
.410
.038 MAX.
.750
.500
CATHODE
ANODE
.045
.035
4 11 R2
Supersedes 1 07 R1
3.2 - 7
.200 TYP.
.005
.120 TYP.
OM4003ST - OM4007ST
MAXIMUM RATINGS
Rating
Symbol
Peak Repetitive Reverse Voltage
VRRM
Working Peak Reverse Voltage
OM
Unit
4003
4004
4005
4006
4007
60
70
80
90
100
Volts
VRWM
DC Blocking Voltage
VR
Average Rectified Forward Current (Rated VR) TC = 100° C
IF(AV)
10
Amps
Peak Repetitive Forward Current
IFRM
20
Amps
IFSM
150
Amps
IRRM
0.5
Amps
Operating Junction Temperature
TJ
-65 to +150
°C
Storage Temperature
Tstg
-65 to +175
°C
RqJC
3
° C/W
(Rated VR, Square Wave, 20 kHz) TC = 100° C
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions halfwave,
single phase, 60 Hz)
Peak Repetitive Reverse Surge Current (2 µs, 1 kHz)
THERMAL CHARACTERISTICS
Maximum Thermal Resistance
ELECTRICAL CHARACTERISTICS
Maximum Instantaneous Forward Voltage (1)
VF
Volts
(iF = 10 Amp, TC = 125° C)
.725
(iF = 10 Amp, TC = 25° C)
.825
Maximum Instantaneous Forward Reverse Current (1)
iR
mA
(Related dc Voltage, TC = 125° C)
150
(Related dc Voltage, TC = 25° C)
5
(1) Pulse Test: Pulse Width = 300 µs, Duty Cycle 2%
3.2
Typical Forward Voltage
Typical Reverse Current
IR - REVERSE CURRENT (mA)
IF - INSTANTANEOUS FORWARD
CURRENT (AMPS)
50
20
10
100°C
150°C
5
3
175°C
TJ = 25°C
1
TJ = 150°C
10
TJ = 125°C
1
TJ = 100°C
0.1
TJ = 25°C
0.01
0.5
0
0.1
0.2
0.3
0.5
0.5
0.6
0.7
0.8
VF - INSTANTANEOUS VOLTAGE (VOLTS)
0.9
1
20
40
60
80
100
VR - REVERSE VOLTAGE (VOLTS)
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246
120