The Compact Isolation Transformer Series: P24T - Chassis Mount with Terminals Power Rating 2.4VA to 100VA Single Primary, 24V Frequency 50/60HZ Center-tapped Secondary, 24V Dielectric Strength – 2500 Vrms Insulation Class B (130°C) Low Capacitive Coupling, no Electrostatic Shield Needed Agency Approvals: UL/cUL 5085-2 Recognized (File E47299) Insulation File No. E95662 Single Primary ● Indicates Like Polarity Primaries and Secondaries are designed to be used simultaneously. That is, they must be used either series or parallel connected (as one winding). Same applies to secondaries also. VA Rating Part Number 2.4 P24T-24-24 6 P24T-06-24 12 P24T-12-24 30 P24T-30-24 50 56 100 Dimensions (Inches) Secondary Weight Lbs L W H A B ML 24VCT @ 100mA 2.063 1.17 1.19 1.45 0.563 1.75 0.25 24VCT @ 250mA 2.375 1.30 1.38 1.70 0.688 2.00 0.44 24VCT @ 500mA 2.813 1.44 1.62 1.95 0.813 2.38 0.70 24VCT @ 1.25A 3.250 1.76 1.94 2.32 1.063 2.81 1.10 P24T-50-24 24VCT @ 2.083A 3.688 1.87 2.25 2.70 1.063 3.12 1.70 P24T-56-24 24VCT @ 2.33A 3.688 1.87 2.25 2.70 1.063 3.12 1.70 P24T-100-24 24VCT @ 4.17A 4.031 2.25 2.56 3.08 1.313 3.56 2.75 Any application, Any requirement, Contact us for our Custom Designs 58 Sales Office: 300 W Factory Road, Addison IL 60101 • Phone: (630) 628-9999 • Fax: (630) 628-9922 • www.wabashtransformer.com