FERROXCUBE P42-3F3-E400

FERROXCUBE
DATA SHEET
P42/29
P cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
P cores and accessories
P42/29
CORE SETS
Effective core parameters
SYMBOL
PARAMETER
32 ±0.7
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.259
mm−1
Ve
effective volume
18200
mm3
Ie
effective length
68.6
mm
Ae
effective area
265
mm2
Amin
minimum area
214
mm2
m
mass of set
≈104
g
17.7
0
5.1
−0.6 ±0.6
35.6
∅5.4
+1.4
0
42.4
±0.7
+0.2
0
+0.2
1 0
29.4
20.3 +0.4 ±0.1
0
CBW431
Dimensions in mm.
Fig.1 P42/29 core set.
Core sets for general purpose transformers and power applications
Clamping force for AL measurements, 550 ±100 N.
GRADE
3C81
3C91
3F3
2008 Sep 01
TOTAL AIR GAP
(µm)
AL
(nH)
µe
315 ±3%
≈ 65
≈ 1320
P42/29-3C81-E315
400 ±3%
≈ 82
≈ 990
P42/29-3C81-E400
TYPE NUMBER
630 ±3%
≈ 130
≈ 580
P42/29-3C81-A630
1000 ±3%
≈ 206
≈ 340
P42/29-3C81-A1000
1600 ±5%
≈ 330
≈ 190
P42/29-3C81-A1600
11500 ±25%
≈ 2370
≈0
P42/29-3C81
11500 ±25%
≈ 2370
≈0
P42/29-3C91
≈ 65
≈ 1320
P42/29-3F3-E315
315 ±3%
400 ±3%
≈ 82
≈ 990
P42/29-3F3-E400
630 ±3%
≈ 130
≈ 580
P42/29-3F3-A630
1000 ±3%
≈ 206
≈ 340
P42/29-3F3-A1000
1600 ±5%
≈ 330
≈ 190
P42/29-3F3-A1600
7700 ±25%
≈ 1590
≈0
1024
P42/29-3F3
Ferroxcube
P cores and accessories
P42/29
Core sets of high permeability grades
Clamping force for AL measurements, 550 ± 100 N.
GRADE
3E27
AL
(nH)
µe
AIR GAP
(µm)
19000 ±25%
≈ 3910
≈0
TYPE NUMBER
P42/29-3E27
Properties of core sets under power conditions
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 25 kHz;
T = 100 °C
f = 25 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
3C81
≥320
≤ 4.2
−
−
−
3C91
≥315
−
3F3
≥315
−
GRADE
≤
≤ 2.0
Note
1. Measured at 60 °C.
2008 Sep 01
0.9(1)
1025
≤
7.0 (1)
−
−
≤ 3.5
Ferroxcube
P cores and accessories
P42/29
COIL FORMERS
General data CP-P42/29 coil former
PARAMETER
SPECIFICATION
Coil former material
polyamide (PA6.6), glass reinforced, flame retardant in accordance with
“UL 94V-0” ; UL file number E41938
Maximum operating temperature
130 °C, “IEC 60085”, class B
19.8 max
handbook, full pagewidth
0.9
5
3
19.6 0.2 35.5 max
5
MGC146
0.2
18 0
1
17.7 min
Dimensions in mm.
Fig.2 Coil former: CP-P42/29.
Winding data and area product for CP-P42/29 coil former
NUMBER OF
SECTIONS
WINDING
AREA
(mm2)
MINIMUM
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
140
17.8
86
37100
CP-P42/29-1S-C
2
2 × 63
2×8
86
2 x 16700
CP-P42/29-2S-C
2008 Sep 01
1026
TYPE NUMBER
Ferroxcube
P cores and accessories
P42/29
MOUNTING PARTS
General data and ordering information
ITEM
Tag plate
REMARKS
FIGURE
material: phenolformaldehyde (PF), glass reinforced
TYPE NUMBER
3
TGP-P42/29-C
4
CON-P42/29
5
SPR-P42/29
flame retardant: in accordance with “UL 94V-0”;
UL file number E41429
maximum operating temperature: 180 °C, “IEC 60085” , class H
pins: copper-tin alloy (CuSn), tin (Sn) plated
resistance to soldering heat in accordance with
“IEC 60068-2-20” , Part 2, Test Tb, method 1B: 350 °C, 3.5 s
solderability in accordance with “IEC 60068-2-20”, Part 2,
Test Ta, method 1: 235 °C, 2 s
Container
copper-zinc alloy (CuZn), tin (Sn) plated
earth pins: presoldered
Spring
CrNi-steel
spring force: ≈350 N when mounted
handbook, full pagewidth
31
2.54
2.1
15.24
2.2
10.16
20.32 15.24 5.08
5.5
∅8.4
∅0.8
mark
6
44.8 max.
Dimensions in mm.
Fig.3 Tag plate: TGP-P42/29-C.
2008 Sep 01
1027
1.3 +0.15
0
CBW606
Ferroxcube
P cores and accessories
P42/29
10
handbook, full pagewidth
8.2
1
44.4
0.6
mark
40.45 min.
5
9
Dimensions in mm.
44.9 max.
32.1 max.
CBW432
Fig.4 P42/29 container.
handbook, halfpage
2.3
+0.5
0
42
max
MGC149
Dimensions in mm.
Fig.5 P42/29 spring.
2008 Sep 01
1028
Ferroxcube
P cores and accessories
P42/29
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
1029