EMCORE PONA3032

PRELIMINARY DATA SHEET | MARCH 21, 2008
PONA 3000 Series Erbium Doped Fiber Amplifier
Applications
•
High Performance Supertrunking Links
•
High Power Distribution Networks
•
Fiber Deep Architectures
•
FTTx Networks
Features
•
Full Function High Power Fiber Optic
Amplifier Ready for Integration
•
Low Noise Figure (Typ < 6 dB)
•
Total Input Power Range: –10 dBm to
The EMCORE PONA 3000 Series Fiber Optical Amplifier Module is an
+12 dBm
ideal building block for OEM system integrators. The family of PONA
Total Output Power: +27 dBm to
3000 Optical Amplifiers is designed to meet the most demanding noise
•
+35 dBm (Optical Output Power
Splitter is Optional For These Units)
performance requirements of CATV and FTTx applications, and
•
Standard RS-232 Communications
performs all the functions required of an optical amplifier for system
•
Low Electrical Power Consumption
integration. Packaged in a convenient 2RU housing, the PONA 3000
•
Input / Output Isolation > 40/40 dB
series optical amplifiers provide optical isolation on the input and output
•
Polarization Dependant Gain < 0.1 dB
•
Polarization Mode Dispersion < 0.5 ps
of the gain block for stable, low noise operation. The input and output
optical signal power levels are detected for monitoring and control. The
input optical signal is amplified with active gain control for a constant
output power level, or with active output power control for constant gain
mode. The PONA 3000 series optical amplifiers also provide
monitoring functions and associated alarms for all vital characteristics.
The optical output of the PONA 3000 series optical amplifiers can be
split into number of ports by an optional internal splitter.
PONA3000 series includes AC/DC power supply, front panel, optical
splitters, network card and all necessary connectors.
1 of 5
For more information on this and other products:
Contact EMCORE sales at 626-293-3400, or visit www.emcore.com.
PRELIMINARY DATA SHEET | MARCH 21, 2008
Specifications
PROPERTY
Product Code
PERFORMANCE
Operating Input Power
Operating Input Power
Output Power
Noise Figure
Static Gain Flatness
Dynamic Gain Flatness
Output Power Stability
Power Consumption
(steady state regime)
Remnant pump power to output
UNIT
LIMIT
PONA MODELS
3030
3032
3027
COMMENT
3035
(note 1)
Pin (dBm)
Pin (dBm)
Po (dBm)
NF (dB)
GF (dB)
(dB)
(dB)
Psys (W)
Max
Min
Typ/Max
Max
Max
Max
Max
Prp (dBm)
Nom.
+12
-10
27.0
5.5/6.0
+/-1.0
+/-2.00
+/- 0.25
40
25
+12
-10
30.0
5.5/6.0
+/-1.0
+/-2.00
+/- 0.25
50
30
+12
-10
32.0
5.5/6.0
+/-1.0
+/-2.25
+/-0.25
65
40
+12
-10
35.0
5.5/6.0
+/-1.0
+/-2.50
+/- 0.25
80
50
<-30
<-30
<-30
<-30
Nominal (note 2)
(note 3)
(note 4)
(note 5)
(note 6)
o
50 C Case (premium)
o
50 C Case (economy)
(note7)
Notes:
1) Unless stated otherwise all specifications apply over the full temperature range and humidity
2) Depending on the fiber optic patchcord interface the measured value can vary up to 0.5 dB less than the actual value
3) Measured @ 25°C, EPin = 0 dBm
4) Measured with a swept Probe Signal (Pp), where Pp = 0 dBm @ 25°C
5) Measured with a swept Probe Signal (Pp), and a fixed Tone Signal (Pt) @ 1553nm; (Pt = Pp+20 dB; Pt + Pp = 0 dBm) @ 25°C
6) Stability over polarization and temperature
7) Premium version – PONA with cooled, Telcordia qualified pumps
Economy version – PONA with uncooled pumps
Physical
GENERAL PROPERTY
Operating Wavelength
Operating Case Temperature
Storage Temperature
Operating Humidity
Voltage Supply Range
REQUIREMENT
COMMENTS
1545 ~ 1562nm
Standard
0°C to 50°C
-40°C to 85°C
20% to 85%
85 VAC to 265 VAC 50/60 Hz
Standard
Standard
Non-condensing
AC version
-36 to -60 V DC
DC version
*(Redundant Power Supply is
Available by Customer Request)
Optical Connectors
See ordering information
Dimensions In Inches
19.0”W x 15.7”D x 3.44”H
User Specified
19’’ Rack Mounted, 2 RU
2 of 5
For more information on this and other products:
Contact EMCORE sales at 626-293-3400, or visit www.emcore.com.
PRELIMINARY DATA SHEET | MARCH 21, 2008
Block Diagram: Cladding Pump Technology
Cladding pump technology uses erbium/ytterbium fiber optic assemblies (double clad fiber and
multi-mode pump lasers) to produce cost effective high power optical amplification. This technology
enables the development of higher power EDFAs-something that is cost prohibitive when using
standard erbium fiber and single mode pumps.
980 nm
pump
Er/Yb Assembly
Er
Input
Hybrid
Filter / Isolator
Input
monitor
Isolator
1% Tap
Output
Monitor
Multi-mode
pumps
Drive
Electronics
Sample FTTx Architecture
Splitter
OLT
Voice
ONT
ONT
ONT
ONT
1490nm
Businesses
1310nm
Data
WDM
1550nm
Video
Splitter
Splitter
1550nm
Tx
- Voice
- Data
- Video
ONT
ONT
ONT
ONT
Multi
Dwelling Units
RF
20 Km
Splitter
ONT
ONT
EDFA
20 outputs of 20
dBm
ONT
ONT
Homes
3 of 5
For more information on this and other products:
Contact EMCORE sales at 626-293-3400, or visit www.emcore.com.
PRELIMINARY DATA SHEET | MARCH 21, 2008
Outline Drawing
AC and DC versions shown below with 8-port option
4 of 5
For more information on this and other products:
Contact EMCORE sales at 626-293-3400, or visit www.emcore.com.
PRELIMINARY DATA SHEET | MARCH 21, 2008
Ordering Information
PONA30
Power
Level
-
-
-
Connector
Options
-
*
-
# of Output
Ports
Class
Input Voltage
27: 27 dBm
SC: SC/APC
01: 1 port
P: Premium
AC: 90-260 VAC 50/60 Hz
30: 30 dBm
FC: FC/APC
02: 2 ports
E: Economy
DC: -48 VDC
32: 32 dBm
35: 35 dBm
EC: E2000/APC
TC: SC/UPC
04: 4 ports
08: 8 ports
GC: FC/UPC
16: 16 ports
20: 20 ports
Class:
2DC: Redundant DC
Premium: Utilizes cooled pump lasers
Economy: Utilizes uncooled pump lasers
* PONA3000 series with one or two optical outputs will have special high power output optical
connector(s) and optical bulkhead(s)
For exact model number, please contact your Sales Representative.
Qualifications
FCC: Subpart B. Part 15, class “A” Unintentional Radiators
CE: EN50083-2, 19995 with Amendment 1, which Incorporates EN 55013 Radiated and
Conducted Emissions
EN 61000-4-3 Radiated Immunity
EN 55020 Conducted Immunity
EN 61000-3-2 Harmonics
All Components Meet Telcordia GR-1312 and GR-486 Standards (Except Pumps in
Economy Class).
EN 61000-3-2 Harmonics
Information contained herein is deemed to be reliable and accurate as of issue date. EMCORE reserves the right to change the design or specifications of
the product at any time without notice. EMCORE, and the EMCORE logo are trademarks of EMCORE Corporation.
5 of 5
For more information on this and other products:
Contact EMCORE sales at 626-293-3400, or visit www.emcore.com.