200 MS/s, 16-Bit Arbitrary Waveform Generator NEW NI PXI-5422 • 16-bit resolution, 200 MS/s sampling rate • 8, 32, 256, or 512 MB of onboard memory • 80 MHz analog bandwidth • Multimodule synchronization with <20 psrms skew • Time and frequency-domain waveform creation software • Function generator emulation mode for easy standard waveform generation • External clock and reference inputs • 16-bit LVDS digital pattern output (32, 256, and 512 MB models) Operating Systems • Windows 2000/NT/XP Recommended Software • NI Modulation Toolkit • LabVIEW • LabWindows/CVI • Measurement Studio Driver Software (included) • NI-FGEN • LabVIEW Express VIs • FGEN Soft Front Panel • NI Analog Waveform Editor (with 32, 265 and 512 MB models) Calibration • Gain, offset and timing self-calibration • 2 year external calibration cycle Description Timing and Synchronization The National Instruments PXI-5422 is a 200 MS/s arbitrary waveform generator featuring 16-bit resolution and up to 512 MB of onboard memory in a compact, 1 slot 3U PXI module. Because the NI PXI-5422 uses the PCI-based PXI platform, waveforms can be downloaded at up to 84 MB/s, far faster than traditional GPIB-based instruments. Using the Synchronization and Memory Core (SMC) architecture of the PXI-5422, you can create mixed signal test systems by synchronizing the generator with digitizers and digital waveform generator/analyzers or synchronize multiple arbitrary waveform generators to form a phase-coherent multichannel generator. • Multi-instrument synchronization with <20 psrms of skew • 3 sample clock sources – Divide-by-N, High-Resolution, and External. • 1.06 µHz sample rate resolution with high-resolution clock • Phase lock to external reference or the PXI 10 MHz reference clock Exceptional Time and Frequency-Domain Performance • 1.8 ns rise time, 6% pulse aberration • -60 dBc (0.1%) total harmonic distortion (THD) at 10 MHz • -139 dBm/Hz average noise density • -81 dBc intermodulation distortion (IMD) with intermediate frequency (IF) optimized direct path • < 1.3 psrms jitter -138 dBc/Hz phase noise (10 MHz carrier, 10 kHz offset) Triggering and Sequencing • Four triggering modes – single, continuous, stepped, and burst • Up to 2 million waveform segments • Up to 3 million sequence instructions (links and loops) • Segment looping up to 16,777,216 times or infinitely Software Applications Communications Digitally modulated I/Q signals Direct to IF modulated signals Semiconductor Imaging sensors (CCD, CMOS) Display devices (LCD) Biomedical devices Mixed signal devices Automotive Telematics systems Antilock brake systems Aerospace/Defense Avionics Radar Scientific Research Analytical instruments • NI Analog Waveform Editor for creating frequency and time-domain signals • NI-FGEN instrument driver with LabVIEW Express VIs for function and arbitrary waveform generation • FGEN Soft Front Panel for interactive control Ordering Information NI PXI-5422 ..............................................................779087-0M1 Includes SMB112 cable, NI-FGEN, and FGEN Soft Front Panel. 32, 256, and 512 MB models include NI Analog Waveform Editor. 1 M (onboard memory): 1 (8 MB), 2 (32 MB), 3 (256 MB), 4 (512 MB) Recommended PXI Switch NI PXI-2593 ..................................................................778793-01 BUY NOW! For complete product specifications, pricing, and accessory information, call (866) 265-9891 (U.S. only) or go to ni.com and search on a four-digit model number listed above. 200 MS/s, 16-Bit Arbitrary Waveform Generator Specifications Onboard Clock (Internal VCXO) General Number of channels......................................... DAC resolution ................................................. Maximum sampling rate .................................. Output paths..................................................... 1 16 bits 200 MS/s 1. Main Output Path setting with driver selected Low Gain Amplifier or High Gain Amplifier 2. Direct Path optimized for IF applications Recommended Maximum Output Frequencies Direct Path ................................................. 80 MHz Low Gain Path ........................................... 80 MHz High Gain Path........................................... 40 MHz up to 12 Vpp (80 MHz up to 8 Vpp) Ω Low Gain Passband Flatness (Typical) 0.000 Attenuation (dB) -5.000 -10.000 -15.000 -20.000 10.00 20.00 30.00 40.00 50.00 60.00 Frequency (MHz) 70.00 80.00 90.00 Spectral Characteristics Intermodulation Distortion (IMD) Frequency 20 kHz Direct Path 100.00 Low Gain Path -85 dBc (0.006%) -81 dBc (0.009%) 1 MHz -87 dBc -63 dBc 10 MHz -67 dBc -60 dBc 10 MHz -80 dBc -78 dBc 40 MHz -65 dBc -63 dBc 70 MHz -60 dBc -55 dBc Average Noise Density Amplitude Range Vpk-pk Path dBm Direct Path 1 4 Low Gain 0.1 -16.0 Low Gain 2 10.0 25.6 12 High gain 8 MB Standard 8,388,608 bytes 32 MB Option 33,554,432 bytes 256 MB Option 268,435,456 bytes 512 MB Option 536,870,912 bytes Output modes ................................................... Function Generator Emulation, Arbitrary Waveform and Arbitrary Sequence Loop count ........................................................ 1 to 16,777,215. Burst Trigger: Unlimited Memory Limits Arbitrary Waveform Mode Maximum Waveform Memory Arbitrary Sequence Mode Maximum Waveform Memory1 Arbitrary Sequence Mode Maximum Waveforms1 Arbitrary Sequence Mode Maximum Segments in a Sequence2 +3.3 VDC 2.0 A 2.0 A 8 MB Standard 4,194,176 Samples 32 MB Option 16,777,088 Samples 256 MB Option 134,217,600 Samples 512 MB Option 268,435,328 Samples 4,194,120 Samples 16,777,008 Samples 134,217,520 Samples 268,435,200 Samples 65,000 Samples 262,000 Samples 2,097,000 Samples 4,194,000 Samples 104,000 Samples 418,000 Samples 3,354,000 Samples 6,708,000 Samples +5 VDC 2.0 A 3.0 A +12 VDC 0.46 A 0.46 A -12 VDC 0.01 A 0.01 A Total Power 22.2 W 27.2 W Typical operating conditions Maximum overload Comments Amplitude –1 dBFS 2nd through 6th harmonics Each tone is -7 dBFS. 200kHz spacing Typical Physical Dimensions....................................................... Front panel connectors CH0 ............................................................ CLK IN ........................................................ PFI 0 ........................................................... PFI 1 ........................................................... Digital data and control ................................... Single 3U PXI slot SMB (Jack) SMB (Jack) SMB (Jack) SMB (Jack) 68-pin VHDCI Female Receptacle Environment Operating temperature..................................... 0 to +55 °C (Meets IEC-60068-2-1 and IEC-60068-2-2) Storage temperature ........................................ -25 to +85 °C (Meets IEC-60068-2-1 and IEC-60068-2-2) Relative humidity ............................................. 10 to 90%, noncondensing (Meets IEC 60068-2-56) Average Noise Density dBm/Hz dBfs/Hz nV/ Hz 25 -139 -143.0 14 -144 -128.0 45 -134 -144.0 282 -118 -143.6 √ Calibration Self-calibration................................................. DC gain and offset External calibration interval............................. 2 years Sources ............................................................ Internal Divide-by-N, Internal High-Resolution, External CLK IN, External DDC Clk In, PXI star Trigger, PXI_TRIG <0:7> Frequency resolution Divide-by-N................................................ (200 MS/s) / N where 1 N 40 High Resolution ......................................... 1.06 µHz ≤ System Phase Noise and Jitter 2 Onboard Memory Size Power Sample Clock Divide-by-N High Resolution External Clock Waveform and Instruction Memory Utilization Refer to detailed specifications for all trigger modes. 1Condition One or two segments in a sequence 2Condition: Waveform memory is <4,000 samples. Rise time .......................................................... < 1.8 ns for Main Output Low Gain Path Fall time............................................................ < 2.1 ns for Main Output Low Gain Path Pulse Aberration............................................... < 6 % for Main Output Low Gain Path Total Harmonic Distortion (THD) Start Trigger Destinations ..................................................... PFI <0:1>, PFI <4:5>, PXI_TRIG <0:6> Quantity ............................................................ 1 Marker per Segment Ω Ω -25.000 0.00 Data output signals.......................................... 16 LVDS data lines (ANSI/TIA/EIA-644 compliant) Markers Amplitude range (full scale) Main output path....................................... 12 Vpp to 5.64 mVpp (50 load) Direct path ................................................. 1 Vpp to 0.707 Vpp (50 load) Offset range ..................................................... ±50% of Amplitude Range (Signal plus offset not to exceed amplitude range) Output impedance ............................................ 50 or 75 , software selectable DC Accuracy ..................................................... ±0.4% of Amplitude ±0.05% of offset ±1 mV AC amplitude accuracy .................................... ± 1.0% of Amplitude ± 1 mV at 50 kHz Output filter ...................................................... Software enabled seven-pole elliptical analog filter available on Main Output Path 5.000 Digital Data and Control, DDC (optional front panel connector) Sources ............................................................ PFI <0:3>, PXI_TRIG<0:6>, PXI Star Trigger, Software, Immediate Modes............................................................... Single, Continuous, Stepped, Burst Analog Output Ω Frequency accuracy .......................................... ±25 ppm PLL reference clock sources............................. PXI_CLK10, CLK IN System Phase Noise Density -138 dBc/Hz (10 kHz offset) -122 dBc/Hz (10 kHz offset) -143 dBc/Hz (10 kHz offset) System Output Jitter < 1.3 ps rms < 3.0 ps rms < 1.1 ps rms Comment 10 MHz carrier Certifications and Compliances CE Mark Compliance Note Unless otherwise noted, the following conditions were used for each specification: A. Analog filter enabled B. Signals terminated with 50 C. Direct path set to 1 Vpk-pk, Low Gain Amplifier Path set to 2 Vpk-pk, and High Gain Amplifier Path set to 12 Vpk-pk D. Sample clock set to 200 MS/s Ω Specifications subject to change without notice. Please see detailed specifications for more information. National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI™ combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Professional Services Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide NI Alliance Partner Program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. ni.com • (800) 433-3488 National Instruments • Tel: (512) 683-0100 • Fax: (512) 683-9300 • [email protected] © 2004 National Instruments Corporation. All rights reserved. Product and company names listed are trademarks or trade names of their respective companies.