LINEAGEPOWER QBW018A0B61-HTZ

Data Sheet
March 27, 2008
QBW018A0B1-TZ DC-DC Converter Power Modules:
36-75Vdc Input; 12Vdc Output; 18A Output Current
RoHS Compliant
Features
ƒ
Compliant to RoHS EU Directive 2002/95/EC
ƒ
Compatible in a Pb-free or SnPb reflow environment
ƒ
High power density: 155 W/in3
ƒ
Delivers up to 18A Output current
ƒ
High efficiency – 93% at 12V full load
ƒ
Low output ripple and noise
ƒ
Industry standard Quarter brick:
57.9 mm x 36.8 mm x 10.6 mm
(2.28 in x 1.45 in x 0.42 in)
Applications
ƒ
ATCA Front Board / Blade
ƒ
Distributed power architectures
ƒ
Servers and storage applications
ƒ
Optical and Access Network Equipment
ƒ
Enterprise Networks
Options
ƒ
Negative Remote On/Off logic
ƒ
Base plate Option (-H)
ƒ
Auto restart after fault shutdown
ƒ
Case ground pin
ƒ
2:1 input voltage range
ƒ
Constant Switching frequency
ƒ
Positive Remote On/Off logic
ƒ
Output overcurrent/voltage protection
ƒ
Over temperature protection
ƒ
Wide operating temperature range (-40°C to 85°C)
ƒ
Meets the voltage insulation requirements for ETSI
300-132-2 and complies with and is Licensed for
Basic Insulation rating per EN 60950-1.
ƒ
CE mark meets 73/23/EEC and 93/68/EEC
directives§
ƒ
UL* 60950-1Recognized, CSA† C22.2 No. 60950-103 Certified, and VDE‡ 0805:2001-12 (EN60950-1)
Licensed
ƒ
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The QBW018A0B-TZ series of modules are similar to the QBW018A0B series (consult the QBW018A0B Series
data sheet) with the following exceptions:
ƒ
The output can accommodate a maximum external capacitance of 10,000 μF (1000uF minimum with
30mA pre-load) to provide power to VRMs requiring high capacitance.
ƒ
The module can withstand a 100V /1 ms input voltage transient.
ƒ
The Turn-on Delay and Rise times have been slowed down to accommodate the large external
capacitance capability (see Fig 4).
ƒ
Enhanced EMI filtering.
ƒ
Active load sharing (Parallel Operation) option is not available.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
‡
Document No: DS06-001 ver. 1.34
PDF name: QBW018A0B1-TZ_ds.pdf
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
VIN
-0.3
75
Vdc
VIN, trans
75
100
Vdc
VIN
-0.3
80
Vdc
All
TA
-40
85
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation Voltage (100% factory Hi-Pot tested)
All
⎯
⎯
1500
Vdc
Input Voltage*
Continuous
Transient (Pulse duration above 75Vdc = 1ms)
Non-operating continuous
Operating Ambient Temperature
(see Thermal Considerations section)
* Input over voltage protection will shut down the output voltage when the input voltage exceeds the maximum threshold or
transient pulse duration levels.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
VIN
36
48
75
Vdc
Maximum Input Current
IIN,max
⎯
⎯
7
Adc
2
⎯
⎯
1
As
(VIN=0V to 75V, IO=IO, max)
It
2
Inrush Transient
All
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to
75V, IO= IOmax ; see Figure 9)
All
⎯
20
⎯
mAp-p
Input Ripple Rejection (120Hz)
All
⎯
50
⎯
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fastacting fuse with a maximum rating of 15A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE POWER
2
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
Device
Symbol
B
VO, set
Min
Typ
Max
12
Unit
Vdc
(VIN=VIN,nom, IO=IO, max, TA=25°C)
Output Voltage
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)
Output Regulation
VO
11.4
⎯
12.6
Vdc
Line (VIN=VIN, min to VIN, max)
All
⎯
0.2
% VO, set
Load (IO=IO, min to IO, max)
All
⎯
3
% VO, set
Temperature (TA= -40°C to 85°C)
All
⎯
150
mV
RMS (5Hz to 20MHz bandwidth)
All
⎯
25
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
Output Ripple and Noise on nominal output
(VIN=VIN, nom IO= IO, min to IO, max)
⎯
mVrms
⎯
70
⎯
mVpk-pk
CO, ext
1000*
⎯
10,000
μF
All
Io
0.030*
18
Adc
B
IO, lim
⎯
20
⎯
Adc
B
η
⎯
93.0
⎯
%
fsw
⎯
300
⎯
kHz
Vpk
⎯
4
⎯
% VO, set
ts
⎯
⎯
μs
Vpk
⎯
⎯
% VO, set
ts
⎯
⎯
μs
External Capacitance (see Note 1 below)
All
Output Current (see Note 1 below)
Output Current Limit Inception
Efficiency
VIN=VIN, nom, TA=25°C
IO=IO, max, VO= VO, set
Switching Frequency
Dynamic Load Response
(ΔIo/Δt=0.1A/μs, VIN=VIN, nom, TA=25°C; Tested
with a 10 μF aluminium and a 1.0 μF tantalum
capacitor across the load)
Load Change from Io= 50% to 75% of Io,max:
Peak Deviation
Settling Time (Vo<10% peak deviation)
B
Load Change from Io= 75% to 50% of Io,max:
Peak Deviation
Settling Time (Vo<10% peak deviation)
B
4
* Note 1 : For proper startup under very light load conditions, either of the following combinations of
minimum output load and output capacitance must be satisfied:
•
For Co, ext (min) = 10uF, Io(min) >/= 0.5A
•
For Io(min) = 30mA, Co, ext >/= 1000 μF
Isolation Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
Ciso
⎯
2000
⎯
pF
Isolation Resistance
Riso
10
⎯
⎯
MΩ
LINEAGE POWER
3
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
General Specifications
Parameter
Device
Calculated MTBF (VIN=48V, IO=80% of IO, max, TA=25°C,
airflow=1m/s(200LFM))
Min
Typ
B
Max
Unit
3088170
⎯
Weight
Hours
⎯
44 (1.55)
g (oz.)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max , Signal referenced to VINterminal)
Negative Logic: Device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
On/Off Thresholds:
Remote On/Off Current – Logic Low
All
Ion/off
5
10
15
μA
Logic Low Voltage
All
Von/off
0.0
⎯
0.8
V
Logic High Voltage – (Typ = Open Collector)
Logic High maximum allowable leakage current
(Von/off = 2.0V)
All
Von/off
2.0
⎯
5.0
V
All
Ion/off
⎯
⎯
6.0
μA
All
Von/off
⎯
⎯
14.0
V
⎯
30
⎯
ms
⎯
15
⎯
ms
⎯
45
⎯
ms
13
⎯
15
Maximum voltage allowed on On/Off pin
Turn-On Delay and Rise Times
(IO=IO, max)
Tdelay = Time until VO=10% of VO, set from either
application of VIN with Remote On/Off set to On or
All
Tdelay
operation of Remote On/Off from Off to On with VIN
applied for at least 1 second
T rise = time for VO to rise from 10% of VO, set to 90%
of VO, set.
Output Overvoltage Protection
Tdelay
enable With Vin
enable With
On/Off
All
Trise
All
V
0
⎯
125
⎯
Turn-on Threshold
⎯
35
36
V
Turn-off Threshold
32
34
⎯
V
Over temperature Protection
All
Tref
C
(See Feature Descriptions)
Input Undervoltage Lockout
LINEAGE POWER
VuVLO
4
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Characteristic Curves
OUTPUT VOLTAGE
5
Io=18A
4
3
2
Io=9A
Io=0A
1
0
30
35
40
45
50
55
60
65
70
75
On/Off VOLTAGE
INPUT CURRENT, Ii (A)
6
VON/OFF(V) (2V/div)
7
VO (V) (5V/div)
The following figures provide typical characteristics for the QBW018A0B-TZ (12V, 18A) at 25ºC. The figures are
identical for either positive or negative Remote On/Off logic.
INPUT VOLTAGE, VO (V)
TIME, t (10 ms/div)
90
Vin=48V
EFFICIENCY (%)
Vin=36V
Vin=75V
85
80
75
70
0
5
10
15
20
OUTPUT CURRENT
OUTPUT VOLTAGE
95
VO (V) (500mV/div)
Figure 4. Typical Start-Up Using Remote On/Off,
negative logic version shown.
IO (A) (5A/div)
Figure 1. Typical Input Characteristic at Room
Temperature.
TIME, t (200 μs/div)
OUTPUT CURRENT, Io (A)
TIME, t (2μs/div)
Figure 3. Typical Output Ripple and Noise at Room
temperature and IO= IO, max.
LINEAGE POWER
IO (A) (5A/div)
VO (V) (500mV/div)
Figure 5. Typical Transient Response to Step change
in Load from 25% to 50% to 25% of Full Load at Room
Temperature and 48 Vdc Input.
OUTPUT CURRENT OUTPUT VOLTAGE
VO (V) (50mV/div)
OUTPUT VOLTAGE,
Figure 2. Typical Converter Efficiency Vs. Output
current at Room Temperature.
TIME, t (200 μs/div)
Figure 6. Typical Transient Response to Step Change
in Load from 50% to 75% to 50% of Full Load at Room
Temperature and 48 Vdc Input.
5
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Characteristic Curves (continued)
OUTPUT VOLTAGE, VO (V)
12.3
12.2
Io=0A
12.1
Io=9A
12
Io=18A
11.9
35
40
45
50
55
60
65
70
75
INPUT VOLTAGE, Vin (V)
Figure 7. Typical Output voltage regulation vs. Input
voltage at Room Temperature.
12.3
OUTPUT VOLTAGE, VO (V)
Vin=48V
12.2
12.1
12
Vin=75V
11.9
Vin=36V
11.8
0
5
10
15
20
OUTPUT CURRENT, IO (A)
Figure 8. Typical Output voltage regulation Vs.
Output current at Room Temperature.
LINEAGE POWER
6
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Test Configurations
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance source. A highly inductive source
impedance can affect the stability of the power
module. For the test configuration in Figure 9, a
100μF electrolytic capacitor (ESR<0.7Ω at 100kHz),
mounted close to the power module helps ensure the
stability of the unit. Consult the factory for further
application guidelines.
Note: Measure input reflected-ripple current with a simulated
source inductance (LTEST) of 12 µH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
Figure 9. Input Reflected Ripple Current Test
Setup.
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum
or tantalum capacitor. Scope measurement should be made
using a BNC socket. Position the load between 51 mm and
76 mm (2 in. and 3 in.) from the module.
Figure 10. Output Ripple and Noise Test Setup.
CONTACT AND
DISTRIBUTION LOSSES
VI(+)
VO1
IO
II
LOAD
SUPPLY
VI(–)
VO2
CONTACT
RESISTANCE
Note: All measurements are taken at the module terminals.
When socketing, place Kelvin connections at module
terminals to avoid measurement errors due to socket contact
resistance.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and
separation requirements of the end-use safety agency
standard, i.e., UL 60950-1-3, CSA C22.2 No. 6095000, and VDE 0805:2001-12 (IEC60950-1).
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75Vdc), for the module’s output to be considered as
meeting the requirements for safety extra-low voltage
(SELV), all of the following must be true:
ƒ
The input source is to be provided with reinforced
insulation from any other hazardous voltages,
including the ac mains.
ƒ
One VIN pin and one VOUT pin are to be
grounded, or both the input and output pins are
to be kept floating.
ƒ
The input pins of the module are not operator
accessible.
ƒ
Another SELV reliability test is conducted on the
whole system (combination of supply source and
subject module), as required by the safety
agencies, to verify that under a single fault,
hazardous voltages do not appear at the
module’s output.
Note: Do not ground either of the input pins of the
module without grounding one of the output
pins. This may allow a non-SELV voltage to
appear between the output pins and ground.
The power module has extra-low voltage (ELV)
outputs when all inputs are ELV.
The input to these units is to be provided with a
maximum 15A fast-acting (or time-delay) fuse in the
ungrounded lead.
Figure 11. Output Voltage and Efficiency Test
Setup.
LINEAGE POWER
7
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Feature Description
Output Over Voltage clamp
Overcurrent Protection
The output overvoltage clamp consists of a control
circuit, independent of the primary regulation loop,
that monitors the voltage on the output terminals and
clamps the voltage when it exceeds the overvoltage
set point. The control loop of the clamp has a higher
voltage set point than the primary loop. This provides
a redundant voltage control that reduces the risk of
output overvoltage.
The module can be restarted by cycling the dc input
power for at least one second or by toggling the
remote on/off signal for at least one second.
To provide protection in a fault output overload
condition, the module is equipped with internal
current-limiting circuitry and can endure current limit
for few mili-seconds. If overcurrent persists beyond a
few milliseconds, the module will shut down and
remain latched off. The overcurrent latch is reset by
either cycling the input power or by toggling the on/off
pin for one second. If the output overload condition
still exists when the module restarts, it will shut down
again. This operation will continue indefinitely until the
overcurrent condition is corrected.
An auto-restart option is also available. An autorestart feature continually attempts to restore the
operation until fault condition is cleared.
Remote On/Off
Two remote on/off options are available. Positive logic
remote on/off turns the module on during a logic-high
voltage on the ON/OFF pin, and off during a logic low.
Negative logic remote on/off turns the module off
during a logic high and on during a logic low. Negative
logic, device code suffix "1," is the factory-preferred
configuration. The on/off circuit is powered from an
internal bias supply. To turn the power module on and
off, the user must supply a switch to control the
voltage between the on/off terminal and the Vi (-)
terminal (Von/off). The switch can be an open
collector or equivalent (see Figure 12). A logic low is
Von/off = 0.0V to 0.8V. The typical Ion/off during a
logic low is 10 µA. The switch should maintain a logiclow voltage while sinking 10µA. During a logic high,
the maximum Von/off generated by the power module
is 5.0V. The maximum allowable leakage current of
the switch at Von/off = 2.0V is 6.0µA. If using an
external voltage source, the maximum voltage V
on/off on the pin is 14.0V with respect to the Vi (-)
terminal. If not using the remote on/off feature,
perform one of the following to turn the unit on:
For negative logic, short ON/OFF pin to VI(-).
For positive logic: leave ON/OFF pin open.
Ion/off
+
Over Temperature Protection
These modules feature an overtemperature protection
circuit to safeguard against thermal damage. The
circuit shuts down and latches off the module when
the maximum device reference temperature is
exceeded. The module can be restarted by cycling
the dc input power for at least one second or by
toggling the remote on/off signal for at least one
second.
Input Under/Over Voltage Lockout
At input voltages above or below the input under/over
voltage lockout limits, module operation is disabled.
The module will begin to operate when the input
voltage level changes to within the under and
overvoltage lockout limits.
ON/OFF
Von/off
–
VO(+)
LOAD
VI(+)
VO(–)
VI(–)
Figure 12. Remote On/Off Implementation.
LINEAGE POWER
8
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel.
Heat-dissipating components are mounted on the top
side of the module. Heat is removed by conduction,
convection and radiation to the surrounding
environment. Proper cooling can be verified by
measuring the thermal reference temperatures (TH1
and TH2). Peak temperatures (TH) occurs at the
positions indicated in Figure 13. For reliable operation
these temperatures should not exceed the listed
temperature threshold.
TH2
TH1
33.9
(1.33)
23.6
(.93)
(14-16) show the maximum output current that can be
delivered by each module in the respective orientation
without exceeding the maximum TH temperatures
versus local ambient temperature (TA) for air flows of
1 m/s (200 ft./min.), 2m/s (400 ft./min.) and 3m/s (600
ft./min.).
The use of Figures 14 - 15 are shown in the following
example:
OUTPUT CURRENT, IO (A)
Data Sheet
March 27, 2008
20
15
10
3m/s (600LFM)
2m/s (400LFM)
5
1m/s (200LFM)
0
0
20
40
60
80
100
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 14. Output Current Derating for the
QBW018A0B-TZ in the Transverse Orientation with no
baseplate; Airflow Direction From Vin(-) to Vin(+); Vin
= 48V.
15.7
(.62)
38.3
(1.51)
Figure 13. Locations of the thermal reference
temperature measurement points TH1 and TH2.
OUTPUT CURRENT, IO (A)
20
15
10
3m/s (600LFM)
2m/s (400LFM)
5
1m/s (200LFM)
0
0
The output power of the module should not exceed
the rated power for the module as listed in the
Ordering Information table.
Although the maximum TH temperatures of the power
modules are 110 °C - 115 °C, you can limit this
temperature to a lower value for extremely high
reliability.
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame BoardMounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
20
40
60
80
100
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 15. Output Current Derating for the
QBW018A0B-TZ in the Transverse Orientation with
baseplate; Airflow Direction From Vin(-) to Vin(+); Vin =
48V.
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. The thermal derating figures
LINEAGE POWER
9
OUTPUT CURRENT, IO (A)
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Layout Considerations
20
The QBW018 power module series are low profile in
order to be used in fine pitch system card
architectures. As such, component clearance
between the bottom of the power module and the
mounting board is limited. Avoid placing copper areas
on the outer layer directly underneath the power
module. Also avoid placing via interconnects
underneath the power module.
15
3m/s (600LFM)
10
2m/s (400LFM)
1m/s (200LFM)
5
0
0
20
40
60
80
100
Post solder Cleaning and Drying
Considerations
LOCAL AMBIENT TEMPERATURE, TA (°C)
OUTPUT CURRENT, IO (A)
Figure 16. Output Current Derating for
QBW018A0B-TZ in the Transverse Orientation
with baseplate and 0.25-inch high heatsink;
Airflow Direction From Vin(–) to Vout(+); Vin = 48V
20
15
3m/s (600LFM)
10
1m/s (200LFM)
5
0
20
40
60
80
100
LOCAL AMBIENT TEMPERATURE, TA (°C)
Figure 17. Output Current Derating for QBW018A0BTZ in the Transverse Orientation with baseplate and
0.5-inch high heatsink; Airflow Direction From Vin(–)
to Vout(+); Vin = 48V
LINEAGE POWER
Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect
both the reliability of a power module and the
testability of the finished circuit-board assembly. For
guidance on appropriate soldering, cleaning and
drying procedures, refer to Lineage Power Board
Mounted Power Modules: Soldering and Cleaning
Application Note.
Through-Hole Lead-Free Soldering
Information
2m/s (400LFM)
0
For additional layout guide-lines, refer to the PIM200X
and FLT007A0 Input Filter Module data sheets.
The RoHS-compliant through-hole products use the
SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant
components. They are designed to be processed
through single or dual wave soldering machines. The
pins have an RoHS-compliant finish that is compatible
with both Pb and Pb-free wave soldering processes.
A maximum preheat rate of 3°C/s is suggested. The
wave preheat process should be such that the
temperature of the power module board is kept below
210°C. For Pb solder, the recommended pot
temperature is 260°C, while the Pb-free solder pot is
270°C max. Not all RoHS-compliant through-hole
products can be processed with paste-through-hole
Pb or Pb-free reflow process. If additional information
is needed, please consult with your Lineage Power
representative for more details.
10
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Mechanical Outline for QBW018A0B-TZ Through-Hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]
TOP
VIEW
SIDE
VIEW
BOTTOM
VIEW
† - Optional pin/pin length shown in Table 2 Device Options.
*Top side label includes Lineage Power name, product designation, and data code.
LINEAGE POWER
11
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Mechanical Outline for QBW-HTZ (Baseplate Version) Through Hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]
TOP
VIEW
SIDE
VIEW
BOTTOM
VIEW
† - Optional pin/pin length shown in Table 2 Device Options.
*Bottom side label includes Lineage Power name, product designation, and data code.
LINEAGE POWER
12
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Recommended Pad Layout for Through Hole Module
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [Unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
†Option Feature, Pin is not present unless this option is specified.
LINEAGE POWER
13
Data Sheet
March 27, 2008
QBW018A0B1-TZ Series Power Modules; DC-DC converters
36-75Vdc Input; 12Vdc Output; 18A Output Current
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 1. Device Code
Input Voltage
Output
Voltage
Output
Current
Efficiency
Connector
Type
Product codes
Comcodes
48V (36-75Vdc)
12V
18A
93%
Through hole
QBW018A0B61-HTZ
CC109101854
Table 2. Device Options
Option
Negative remote on/off logic
Auto-restart
Pin Length: 3.68 mm ± 0.25mm (0.145 in. ± 0.010 in.)
Case ground pin (offered with baseplate option only)
Pin Length: 2.79 mm ± 0.25mm (0.110 in. ± 0.010 in.)
Base Plate option
Suffix
1
4
6
7
8
-H
Note: Legacy device codes may contain a –B option suffix to indicate 100% factory Hi-Pot tested to the isolation voltage specified in
the Absolute Maximum Ratings table. The 100% Hi-Pot test is now applied to all device codes, with or without the –B option suffix.
Existing comcodes for devices with the –B suffix are still valid; however, no new comcodes for devices containing the –B suffix will
be created.
Asia-Pacific Headquarters
Tel: +65 6416 4283
World Wide Headquarters
Lineage Power Corporation
3000 Skyline Drive, Mesquite, TX 75149, USA
+1-800-526-7819
(Outside U.S.A.: +1-972-284-2626)
www.lineagepower.com
e-mail: [email protected]
Europe, Middle-East and Africa Headquarters
Tel: +49 89 6089 286
India Headquarters
Tel: +91 80 28411633
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or
application. No rights under any patent accompany the sale of any such product(s) or information.
© 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved.
Document No: DS06-001 ver. 1.34
PDF name: QBW018A0B1-TZ_ds.pdf