Crystal filter QF70.0-9000/06 Application • 6 pol filter • i.f.- filter • use in mobile and Limiting values stationary transceivers Nominal frequency Insertion loss Pass band at 3.0dB Ripple in pass band Stop band attenuation Alternate attenuation Spurious responses Group delay distortion Maximum input level fo fo ± 30 kHz fo ± 90 kHz fo ± 150 kHz fo ± 22.5 kHz fo ± 45 kHz without damage Terminating impedance Z R1||C1 R2||C2 Operating temp. range Storage temp. range Environment conditions Characteristics Pass band Pin connections: Unit Value MHz dB kHz dB dB dB dB dB µs µs dBm 70.0 < 6.0 ±> 45 < 1.0 > 40 > 50 > 70 except spurious > 50 <3 < 25 + 10 Ohm/pF Ohm/pF 50 || 0 50 || 0 °C °C -20... +70 -45... +85 according to CF001 QF70.0-9000/06 Stop band 1 2 3 4 Input Ground-Input Output Ground-Output TELE FILTER Zweigniederlassung der DOVER Germany GMBH 11.01.06 Potsdamer Str. 18 D- 14513 Teltow (+49)03328-4784-10 ; Fax (+49)03328-4784-30 http:\\www.vectron.com