RECOM REC20

Features
Regulated
Converters
●
●
●
●
●
●
●
●
ECONOLINE
20W 1”x 2” Package (50.1x25.4x10.8mm)
1.6kVDC Isolation
Wide Input 2:1
Regulated Output
UL94V-0 Package Material
Continuous Short Circuit Protection
Remote ON/OFF-Control for Single Types
Efficiency to 87%
DC/DC-Converter
REC20SRW/H
Series
20 Watt
1” x 2”
Single
Output
Selection Guide
Part
Number
1” x 2”
Input
Output
Output
Efficiency
Voltage
Voltage
Current
(VDC)
(VDC)
(mA)
(%)
REC20-xx2.5SRW/H
18-36, 36-75
2.5
4000
83
REC20-xx3.3SRW/H
18-36, 36-75
3.3
4000
86
REC20-xx05SRW/H
18-36, 36-75
5
4000
87
2:1
xx = 18-36Vin = 24
xx = 36-75Vin = 48
* add suffix "CTRL" for optional Remote ON/OFF-Control
Specifications (Core Operating Area)
Input Voltage Range
2:1
π type
Input Filter
Output Voltage Accuracy
±0.5% max.
Load Voltage Regulation (10% to 100% full load )
Ripple
Noise
±1% max.
110mVp-p max.
200mVp-p max.
Operating Frequency
400kHz typ.
Works over 120% of rating and recovers automatically
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Current limit, auto-recovery
Transient Response
87% max.
1600VDC min.
see Application Notes
(tested for 1 second)
(long term isolation)
Isolation Capacitance
100 MΩ min.
-25°C to +70°C (see Graph)
Storage Temperature Range
-55°C to +105°C
Case Temperature
+100°C max.
Temperature Coefficient
±0.02%/°C
Case Material
MSL Level 1
95% RH
Nickel-Plated Copper with Non-Conductive Base, Six-side Shielded
Cooling Method
Natural convection
Package Weight
32g
EMI (Conducted & Radiated Emission)
MTBF (+25°C) Detailed Information see
(+40°C) Application Notes chapter "MTBF"
}
128
(Ambient Temperature)
120
100
1000pF
Isolation Resistance
Operating Temperature Range (Natural convection) (with derating)
Relative Humidity
Derating-Graph
500 us (100% to 50% full load at ±1% error band)
using MIL-HDBK 217F
using MIL-HDBK 217F
July-2006
Output Power (%)
Efficiency at Full Load
Isolation Voltage
Rated Working Voltage
UL-60950-1 Pending
±2% max.
Line Voltage Regulation
Over Power Protection
Designed to meet EN-60950-1
80
60
Safe Operating Area
40
20
0
-25
0
25 40 50
70
75
100
Operating Temperature (°C)
EN 55022 class A
>550 x 103 hours
193 x 103 hours
www.recom-international.com
ECONOLINE
REC20-SRW/H
Series
DC/DC-Converter
Package Style and Pinning (mm) 1” x 2” , Wide Input 2:1
3rd angle
projection
1“ x 2“ PIN Package
50.10
25.40
25.40
20.32
20.32
10.80
6.00
1.0
15.24
20.32
Recommended Footprint Details
Pin Connections
5.08
1
2
Pin #
1
2
3
4
5
5
3
10.16
Bottom View 4
2
2.54
1
10.16
4
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
3
5
2.54
Top View
2.54
Single
+Vin
-Vin
+Vout
No Pin
-Vout
1.2ø+0.2/–0.1
REC20-Series also available with Remote ON/OFF - Control
For detailed information please contact your RECOM representative.
Recommended Footprint Details
REC20-SRW/H/CTRL
6
3
5.08
1
2
10.16
Bottom View 4
1
10.16
7.62
6
2
2.54
Pin #
1
2
3
4
5
6
4
3
5
2.54
www.recom-international.com
Pin Connections
5
2.54
July-2006
Top View
1.2ø+0.2/–0.1
Single
+Vin
–Vin
+Vout
No Pin
-Vout
CTRL
XX.X ± 0.5 mm
XX.XX ± 0.25 mm