RECOM REC3-120515DRWIAM

Features
Regulated
Converters
●
●
●
●
●
●
●
ECONOLINE
3W DIP Package Isolated Dual Outputs
Vout1 / Vout2
Input / Output 2KVDC Isolation min.
UL94V-0 Package Material
Continuous Short Circuit Protection
Auto-Restarting (V1)
Wide Input 2:1
Internal SMD design
100% Burned In
DC/DC-Converter
REC3DRWI/A
Series
Selection Guide
Part
Number
Input
Voltage
Output
Voltage
Output
Current
Output
Voltage
Output
Current
DIP24
(VDC)
Vout1(VDC)
at Vout1(mA)
REC3-050505DRWI/A
4.5-9
5
300*
5
300
REC3-050509DRWI/A
4.5-9
5
300*
9
167
REC3-050512DRWI/A
4.5-9
5
300*
12
125
REC3-050515DRWI/A
4.5-9
5
300*
15
100
REC3-120505DRWI/A
9-18
5
300*
5
300
REC3-120509DRWI/A
9-18
5
300*
9
167
REC3-120512DRWI/A
9-18
5
300*
12
125
REC3-120515DRWI/A
9-18
5
300*
15
100
REC3-240505DRWI/A
18-36
5
300*
5
300
REC3-240509DRWI/A
18-36
5
300*
9
167
REC3-240512DRWI/A
18-36
5
300*
12
125
REC3-240515DRWI/A
18-36
5
300*
15
100
REC3-480505DRWI/A
36-72
5
300*
5
300
REC3-480509DRWI/A
36-72
5
300*
9
167
REC3-480512DRWI/A
36-72
5
300*
12
125
REC3-480515DRWI/A
36-72
5
300*
15
100
Vout2(VDC) at Vout2(mA)
3 Watt
DIP24
Isolated
Dual Output
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
* V1 min. load 100mA to supply V2 well
* add suffix "M" for Metal Case, e.g. REC3-240505DRWI/AM
For alternative custom output voltage and power combinations, please contact Recom Technical Support
Specifications (Core Operating Area)
Input Voltage Range
2:1
Output Voltage Accuracy
±2% max.
Line Voltage Regulation
±0.4% max.
Load Voltage Regulation (10% to 100% full load )
±0.6% max.
Output Ripple and Noise (at 20MHz BW)
50mVp-p max.
Operating Frequency
100kHz typ.
No Load Power Consumption
Isolation Voltage
Input / Output (tested for 1 second)
Vout1 / Vout2 (tested for 1 second)
Rated Working Voltage
(long term isolation)
300mW max.
2000VDC min.
500VDC min.
see Application Notes
Isolation Capacitance
40pF typ.
Isolation Resistance
1 GΩ min.
Short Circuit Protection (V1)
Continuous
Operating Temperature Range
Vin=5V
-40°C to +80°C (see Graph)
(free air convection)
Vin=12, 24, 48V
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
continued on next page
www.recom-international.com
January-2007
109
ECONOLINE
REC3-DRWI/A
Series
DC/DC-Converter
Specifications (Core Operating Area)
Relative Humidity
95% RH
Case Material
Non-Conductive Plastic
Thermal Impedance
Natural convection
20°C/W for metal case
Package Weight
MTBF (+25°C)
(+80°C)
13g
Detailed Information see
Application Notes chapter "MTBF"
3
using MIL-HDBK 217F
877 x 10 hours
using MIL-HDBK 217F
138 x 103 hours
Derating-Graph
(Ambient Temperature)
Vin = 5V
Vin = 12, 24, 48V
100
100
20
0
80
(2W) 67
60
(1.5W) 50
40
Safe Operating Area
100
80 105
96
Operating Temperature °C
-40
0
50
Output Power (%)
Output Power (%)
80
(2W) 67
60
(1.5W) 50
40
150
Safe Operating Area
20
0
100
85 105
98
Operating Temperature °C
-40
0
50
150
Package Style and Pinning (mm) Wide Input 2:1
3rd angle
projection
24 PIN DIP Package
20.30
32.00
Pin Connections
10.20
3.81
0.51
4.60
15.24
Recommended Footprint Details
1.00 ø+0.15/–0
2 3
9
11
16
14
–Vin
3
–Vin
9
+Vout 2
11
–Vout 2
14
+Vout 1
16
–Vout 1
22
+Vin
23
+Vin
2.54
2.54
110
Dual
2
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Bottom View
23 22
Pin #
Top View
January-2007
www.recom-international.com