ANADIGICS RFSP2010

Preliminary
RFSP2010
2.4–2.5 GHz Power Amplifier
Product Description
Applications
The RFSP2010 power amplifier is a highperformance GaAs HBT IC designed for use in
transmit applications in the 2.4-2.5 GHz frequency
band. With a P1dB of 25 dBm, the device is ideal
as a final stage for wireless LAN applications
requiring high transmit linearity. Designed with
propriety linearizing techniques, the part is
operable closer to P-1dB, which enables the device
to achieve a specific error vector magnitude
(EVM) with less backoff. The PA exhibits
unparalleled linearity and efficiency for both
802.11b- and 802.11g-based WLAN systems. The
part operates off a single +3.3V supply.
• 802.11b/g WLAN
• 2.4 GHz ISM band wireless equipment
2
VBCC2
RF IN
VCC1
1
VBCC1
NC
12
11
10
Bias
Bias
Input
Match
Output
Match
9
VCC2
8
RF OUT
Product Features
GND
3
7
4
5
6
NC
VPC
NC
• 25 dBm [email protected]
• 21.5 dB gain
• 1.5 % EVM @ POUT = +18 dBm
with 54 Mbps OFDM signal
• 95 mA @ POUT = +18 dBm
with 54 Mbps OFDM signal
• Single +3.3V supply voltage
• PA power on/off logic
• Input and output matched to 50 ohms
GND
Functional Block Diagram
1.00
0.80
4
3.00
0.45
0.35
0.275
0.225
Pin 1
12
Index Area
1
0.50 TYP
3.00
1. All dimensions are in millimeters, angles in
degrees.
2. The terminal #1 identifier and pad
numbering convention shall conform to
JESD 95-1 SPP-012
3. Lead coplanarity: 0.05 max.
4. Dimension applies to metalized pad and is
measured between 0.25 and 0.30 MM from
pad tip.
0.05
1.00
1.80 SQ
Top View
Side View
Bottom View
3x3 mm Package Outline
05/2003
RFSP2010
2.4–2.5 GHz Power Amplifier
Parameter
Specification
1
Min.
Overall
Frequency Range
Output P1dB
Gain
Error Vector Magnitude2
Gain Flatness
Harmonics
2nd Harmonic
3rd Harmonic
Spurious (Stability)3
Reverse Isolation
Input Return Loss
Output Return Loss
Power Supply
Operating Voltage
Current Consumption
Typ.
2400
Max.
2500
25
21.5
1.5
±0.5
-27
-45
-60
Condition
MHz
dBm
dB
%
dB
POUT = +18 dBm
POUT = +18 dBm; 54 Mbps OFDM signal
Across 100 MHz Band
dBc
dBc
dBc/30 kHz
dB
dB
dB
35
10
10
3.3
95
180
Shutdown Control
Device On Logic High
Device Off Logic Low
Device Off Current
Turn-On Time
Turn-Off Time
Unit
3.3
0.7
1
500
500
@ P1dB
@ P1dB
POUT = -20 dBm to P1dB
With matching capacitor
V
mA
mA
POUT = +18 dBm; 54 Mbps OFDM signal
POUT = +24 dBm; meets 802.11b ACPR spec
V
V
uA
ns
ns
With 50Ω source
With 50Ω source
Note 1: Test Conditions: VCC = 3. 3V, Freq. = 2450 MHz, T =25 °C, Small Signal Conditions unless otherwise stated.
Note 2: Increase in EVM over system EVM floor.
Note 3: Load VSWR is set to 7:1 and the angle is varied 360 degrees.
Absolute Maximum Ratings
Parameter
DC Power Supply
DC Supply Current
Maximum RF input level
Operating Ambient Temperature
Storage Temperature
Rating
Unit
6.0
400
+7
-40 to +85
-55 to +150
V
mA
dBm
°C
°C
Ordering Information
Part Number
PRFS-P2010-EVL
PRFS-P2010-005
PRFS-P2010-006
PRFS-P2010-007
PRFS-P2010-008
PRFS-P2010-009
2
Temp. Range (°C)
-40 to +85
-40 to +85
-40 to +85
-40 to +85
-40 to +85
-40 to +85
Package Description
Evaluation Board
13" Reverse Tape/Reel
13" Tape/Reel
7" Reverse Tape/Reel
7" Tape/Reel
Bulk – 4x4 mm 24-pin LPCC
05/2003
Quantity
1
2500 pcs.
2500 pcs.
1000 pcs.
1000 pcs.
1-999 pcs.
NOTES
05/2003
3
ANADIGICS, Inc.
141 Mount Bethel Road
Warren, New Jersey 07059,U.S.A.
Tel: +1(908)668-5000
Fax: +1(908)668-5132
URL: http://www.anadigics.com
E-mail: [email protected]
IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or to discontinue any product at any time without notice. The product
specifications contained in Advanced Product Information sheets and Preliminary Data Sheets are subject to change prior to a product’s formal
introduction. Information in Data Sheets have been carefully checked and are assumed to be reliable; however, ANADIGICS assumes no
responsibilities for inaccuracies. ANADIGICS strongly urges customers to verify that the information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, devices or systems. Use of an ANADIGICS product in any such application
without written consent is prohibited.
4
05/2003