EIC RK13

RK13 - RK19
SCHOTTKY BARRIER
RECTIFIER DIODES
PRV : 30 - 90 Volts
IO : 1.5 - 1.7 Amperes
D2
FEATURES :
*
*
*
*
*
*
*
High current capability
High surge current capability
High reliability
High efficiency
Low power loss
Low forward voltage drop
Low cost
1.00 (25.4)
MIN.
0.161 (4.1)
0.154 (3.9)
0.284 (7.2)
0.268 (6.8)
1.00 (25.4)
MIN.
0.034 (0.86)
0.028 (0.71)
MECHANICAL DATA :
* Case : D2 Molded plastic
* Epoxy : UL94V-O rate flame retardant
* Lead : Axial lead solderable per MIL-STD-202,
Method 208 guaranteed
* Polarity : Color band denotes cathode end
* Mounting position : Any
* Weight : 0.465 gram
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 ° C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
RATING
SYMBOL
RK13
RK14
RK16
RK19
UNIT
Maximum Recurrent Peak Reverse Voltage
VRRM
30
40
60
90
Volts
Maximum DC Blocking Voltage
VDC
30
40
60
90
Volts
Maximum Average Forward Current TL = 75 °C
IF(AV)
1.7
1.5
Amps.
Peak Forward Surge Current single half sine wave
Superimposed on rated load
Maximum Forward Voltage at IF
IFSM
(Note 1)
50
Amps.
VF
0.55
IF
2.0
Rated DC Blocking Voltage (Note 1)
IR
5.1
Junction Temperature Range
TJ
- 40 to + 125
°C
Storage Temperature Range
TSTG
- 40 to + 125
°C
Maximum Forward Current
0.62
0.81
1.5
Volt.
Volts.
Maximum Reverse Current at
1.0
2
mA
Notes :
(1) Pulse Test : Pulse Width = 300 µs, Duty Cycle = 2%.
UPDATE : SEPTEMBER 12, 1998
RATING AND CHARACTERISTIC CURVES ( RK13 - RK19 )
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
50
2.0
RK13,RK14
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD CURRENT,
AMPERES
FIG.1 - FORWARD CURRENT DERATING CURVE
1.6
RK16,RK19
1.2
0.8
0.4
0
0
25
50
75
100
125
150
40
30
20
10
0
175
1
LEAD TEMPERATURE, (° C)
FORWARD CURRENT, AMPERES
20
RK19
RK13
RK14
RK16
1.0
TJ = 25 °C
PULSE WIDTH = 300µs
DUTY CYCLE = 1%
0.1
0.1
0.3
0.5
0.7
0.9
1.1
1.3
1.5
1.7
FORWARD VOLTAGE, VOLTS
4
6
10
20
40
60
100
1.9
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
REVERSE CURRENT, MILLIAMPERES
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
10
2
NUMBER OF CYCLES AT 60Hz
10
TJ = 100 °C
1.0
TJ = 25 °C
0.1
0.01
0
2.1
20
40
60
80
100
120
PERCENT OF RATED REVERSE
VOLTAGE, (%)
140