ETC 3202075001

PRESSURE AND VACUUM TRANSMITTERS
0.5% ACCURACY, HEAVY DUTY SENSOR,
INTERNAL DIAPHRAGM
• Internal diaphragm
Type
• Full stainless steel wetted parts
E110
• Sensing ranges from -1… 0 bar to 0… 4000 bar
• Ex certified to ATEX 100a
• 0.5% accuracy class
PART NUMBERS
TECHNICAL SPECIFICATION
E110
Range (Bar)
-1 to 0
-0.6 to 0
-0.4 to 0
-0.25 to 0
-0.16 to 0
-0.1 to 0
0 to 0.1
0 to 0.16
0 to 0.25
0 to 0.4
0 to 0.6
0 to 1
0 to 1.6
0 to 2.5
0 to 4
0 to 6
0 to 10
0 to 16
0 to 25
0 to 40
0 to 60
0 to 100
0 to 160
0 to 250
0 to 400
0 to 600
0 to 1000
0 to 1600
0 to 2500
0 to 4000
Type
016001
015001
014001
013001
012001
011001
063001
064001
065001
066001
067001
069001
070001
072001
073001
074001
075001
076001
078001
079001
080001
081001
082001
084001
086001
087001
088001
089001
090001
091001
EEx ia 11C T6
Pressure type
Negative or positive gauge pressure
Output signal
4…20 mA, 2 wire system
Accuracy class
0.5% of full scale
Measuring ranges
-1… 0 Bar, to 0… 4000 Bar
≤ 16 bar - Piezoresistive, ≥ 25 bar - Thin film
Sensor element
≤ ±0.05% of full scale
Repeatability
Case
Stainless steel 1.4571
Wetted parts
Stainless steel 1.4541 & 1.4542
Thread connection
≤1600 Bar
>2500 Bar
Please note that items in bold are available from stock
G1/2 B according to Din 16288 (1/2" BSP)
M16 x 1.5 female
Overload limit
≤16 Bar
≤600 Bar
1000 Bar
>1000 Bar
4000 Bar
3.5 x full scale value
2 x full scale value
1.5 x full scale value
1.2 x full scale value
1.1 x full scale value
Power supply
11… 28Vdc
Power consumption
Signal current
Load (Ω)
≤ Supply - 10V
0.020 A
Power restriction
1.75W
Temperature
Compensation range
Influence on zero point
and measuring range
DIMENSIONS
Type
E110
All dimensions
in mm
E110
Explosion proof
protection type
48
Adjustability
Up to ±5% with potentiometers
≤1ms (within 10% to 90% of full scale)
Response time
103
Protection class
IP65 EN 60529/IEC 529
Electrical protection
Reverse polarity, overvoltage and short circuit
Temperature ranges
Storage
Media
Ambient
-60… +105°C
-20… +60°C
-20… +60°C
Weight approx (Kg)
0.2
OPTIONS
AF27
3
3 20
75.5
ø27
ø6
0… +60°C/T6
≤0.2%/10K
(≤0.4%/10K, for ranges <0.25 Bar)
ø17.5
G1/2B (1/2" BSP)
0800 731 3187
•
•
•
Other outputs (mA/Volts)
Connection threads
Absolute pressures
49
•
•
•
0.25% accuracy
Flush diaphragm
Cable Output IP 67
WWW.OEM.CO.UK