RECOM RP10

Features
●
●
●
●
●
●
●
●
●
2:1 Wide Input Voltage Range
10 Watts Output Power
1.6kVDC Isolation
Fixed Operating Frequency
Six-Sided Continuous Shield
International Safety Standard Approvals
UL 1950 Component Recognized
Standard 50.8 x25.4x10.2mm Package
Efficiency to 86%
Selection Guide 12V, 24V and 48V Input Types
Part Number
Output
Current
mA
Input (4)
Current
mA
Efficiency(5)
Capacitive(6)
Load max.
µF
Input
Range
VDC
Output
Voltage
VDC
RP10-123.3SE
9-18
3.3
2000
724
80
6800
RP10-1205SE
9-18
5
2000
1082
81
4700
RP10-1212SE
9-18
12
830
1064
82
690
RP10-1215SE
9-18
15
670
1088
81
470
RP10-243.3SE
18-36
3.3
2000
362
80
6800
RP10-2405SE
18-36
5
2000
534
82
4700
RP10-2412SE
18-36
12
830
519
84
690
RP10-2415SE
18-36
15
670
523
84
470
RP10-483.3SE
36-75
3.3
2000
183
79
6800
RP10-4805SE
36-75
5
2000
260
84
4700
RP10-4812SE
36-75
12
830
253
86
690
RP10-4815SE
36-75
15
670
258
85
470
RP10-1205DE
9-18
±5
±1000
1068
82
±680
RP10-1212DE
9-18
±12
±416
1053
83
±330
RP10-1215DE
9-18
±15
±333
1041
84
±110
RP10-2405DE
18-36
±5
±1000
548
80
±680
RP10-2412DE
18-36
±12
±416
520
84
±330
RP10-2415DE
18-36
±15
±333
520
84
±110
RP10-4805DE
36-75
±5
±1000
267
82
±680
RP10-4812DE
36-75
±12
±416
254
86
±330
RP10-4815DE
36-75
±15
±333
260
84
±110
%
POWERLINE
DC/DC-Converter
RP10S_DE
Series
10 Watt
2” x 1” Package
Single &
Dual Output
Description
The E-Series of DC/DC Converters are fully certified to EN 60950: 2000. This makes them ideal for all
Telecom and safety applications where approved isolation is required.
They also meet UL 1950 and CSA 950 standards (9).
206
April-2005
www.recom-international.com
POWERLINE
RP10-S_DE
Series
DC/DC-Converter
Derating-Graph (Ambient Temperature)
125
RP10-2405SE
100
100
76
75
Natural Convection
50
Output Power (%)
Output Power (%)
67
RP10-2405SE With Heat Sink
125
25
0
-25
-10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
79
75
Natural Convection
50
25
0
-25
125
100
75
Natural Convection
50
Output Power (%)
Output Power (%)
100
86
75
25
0
-25
-10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
79
25
0
-25
100
75
75
Natural Convection
Output Power (%)
Output Power (%)
100
25
-10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
50
0
-40 -25 -10 0
100
100
Output Power (%)
Output Power (%)
75
Natural Convection
25
Ambient Temperature Range (°C)
80 90 100
85
RP10-2405SE_DE/M1 With Heat Sink
125
50 60 70
50 60 70
Ambient Temperature Range (°C)
RP10-4805SE/M1
0
-40 -25 -10 0
Natural Convection
25
125
50
50 60 70 80 90 100
83
RP10-2405SE_DE/M1
125
0
-25
-10 0
Ambient Temperature Range (°C)
RP10-4805SE
50
Natural Convection
50
125
75
50 60 70 80 90 100
81
RP10-2405DE With Heat Sink
RP10-2405DE
125
67
-10 0
Ambient Temperature Range (°C)
80 90 100
85
50
Natural Convection
25
0
-40 -25 -10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
88
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at [email protected]
www.recom-international.com
April-2005
207
RP10-S_DE
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
Input Filter
Input Surge Voltage (100 ms max.)
9-18VDC
18-36VDC
36-75VDC
Pi Type
12V Input
24V Input
48V Input
36VDC
50VDC
100VDC
Input Reflected Ripple (nominal Vin and full load)
30mAp-p
Start Up Time (nominal Vin and constant resistor load)
20ms typ.
Remote ON/OFF (see note 8)
(Positive logic)
DC-DC ON
DC-DC OFF
Short or 0V < Vr < 1.2V
(Negative logic)
DC-DC ON
Short or 0V < Vr < 1.2V
DC-DC OFF
Open or 3.5V < Vr < 12V
Remote OFF input current
Nominal input
Output Power
±2%
Minimum Load (see Note 1)
10% of FL
Line Regulation (LL-HL at full load)
±1%
Single
Dual
Cross Regulation (asymmetrical load 25%/100% FL)
Ripple and Noise (20MHz bandwith)
±1%
±2%
±5%
Single
50mVp-p
Dual
75mVp-p
Temperature Coefficient
±0.02%/°C, max.
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp
2.5mA
10W max.
Output Voltage Accuracy (full Load and nominal Vin)
Load Regulation (25% to 100% FL)
Open or 3.5V < Vr < 12V
500µS
3.3V output
5V output
12V output
15V output
Over Load Protection (% of full load at nominal Vin)
3.9V
6.2V
15V
18V
150% typ
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage
1.600VDC min.
Isolation Resistance
109 Ω min.
Isolation Capacitance
300pF max.
Operating Frequency
300kHz typ.
Approved to Safety Standards
UL 1950, EN60950
Operating Temperature Range
Standard
-25°C to +85°C(with derating)
(Reference Derating Curve)
M1
-40°C to +85°C(non derating)
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +105°C
continued on next page
208
April-2005
www.recom-international.com
RP10-S_DE
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Thermal Impedance
Natural convection
12°C/Watt
Natural convection with Heat Sink
10°C/Watt
Thermal Shock
MIL-STD-810D
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel-Coated copper
Base Material
Non-conductive black plastic
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Epoxy (UL94-V0)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Weight
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
27g
Dimensions
50.8 x 25.4 x 10.2mm
1.976 x 106 Hours
MTBF (see note 2)
Notes :
1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listedspecification.
2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input.
Positive logic ON/OFF is standard, no suffix (Ex. RP10-2405SE)
Negative logic ON/OFF is marked with suffix-N (Ex. RP10-2405SE/N).
8. Heat sink is optional and P/N: 7G-0020A.
9. The M1 version (RP10-xxxxSE/M1, RP10-xxxxDE/M1) does not carry the UL certification.
10.M1 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
11. See application notes for EMI-filtering.
www.recom-international.com
April-2005
209
RP10-S_DE
Series
POWERLINE
DC/DC-Converter
Package Style and Pinning (mm)
3rd angle
projection
50.80
25.40
10.20
dia.
1.0
5.6
2.50
5.10
20.30
15.20
Pin Connections
3
1
2
6
210
Bottom View
10.20
4
10.20
5
12.70
Pin #
1
2
3
4
5
6
Single
+Vin
-Vin
+Vout
No Pin
-Vout
CTRL
Dual
+Vin
-Vin
+Vout
Com
-Vout
CTRL
Pin Pitch Tolerance ±0.35 mm
April-2005
www.recom-international.com