ASTRODYNE SB08-245S

SB08
I s o l a t e d a n d R e gulated 8 WATT Modular DC/DC Converters
series
6 Sided EMI Shielding
Regulated Outputs
1600V Isolation
Short Circuit Protection
2:1 Inputs
Input PI Filter
Unit measures 0.8”W x 1.25”L x 0.4”H
Model Number
SINGLE OUTPUT
SB08-123.3S
SB08-243.3S
SB08-483.3S
SB08-125S
SB08-245S
SB08-485S
SB08-1212S
SB08-2412S
SB08-4812S
SB08-1215S
SB08-2415S
SB08-4815S
SB08-1224S
SB08-2424S
SB08-4824S
DUAL OUTPUT
SB08-125D
SB08-245D
SB08-485D
SB08-1212D
SB08-2412D
SB08-4812D
SB08-1215D
SB08-2415D
SB08-4815D
Output Voltage
Output Amps
Input Range
3.3VDC
2
2
2
1.5
1.5
1.5
0.666
0.666
0.666
0.533
0.533
0.533
0.333
0.333
0.333
9-18 VDC
18.36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
+/-0.800
+/-0.800
+/-0.800
+/-0.333
+/-0.333
+/-0.333
+/-0.267
+/-0.267
+/-0.267
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
9-18 VDC
18-36 VDC
36-75 VDC
5 VDC
12 VDC
15 VDC
24VDC
+/-5 VDC
+/-12 VDC
+/-15 VDC
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
SB08
I s o l a t e d a n d R e gulated 8 WATT Modular DC/DC Converters
INPUT SPECIFICATIONS
Input Voltage Ranges:
GENERAL SPECIFICATIONS
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
9-18 VDC
18-36 VDC
36-75 VDC
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation
Line Regulation
Temperature Coefficient
Ripple/Noise(Single/Dual)
Voltage Accuracy
Short Circuit Protection
Efficiency
series
Input-Out Isolation
Isolation Resistance
Switching Frequency
1600VDC
10-9nth Ohm min.
300Khz
ENVIRONMENTAL SPECIFICATIONS
See Selection Chart
10% to FL
(HL-LL)
+/-0.02%/°C
0.7% +70mVp-p max.
+/- 2%
Continuous
123.3S, 125S, 125D,
243.3S, 245S, 245D,
483.3S, 485S,
485D
1212D, 1215D, 2412D,
2415D, 4812D, 4815D
1212S, 1215S, 1224S,
2412S, 2415S, 2424S,
4812S, 4815S, 4824S
+/- 1%
+/- 0.5%
-20 to +60°C(FL)
-55 to +105°C *
Free Air Convection
PHYSICAL SPECIFICATIONS
Case Material
78%
79%
Construction
Weight
Nickel-Coated Copper with
Non-Conductive Base
Fully Encapsulated
0.9 oz, (25g)
81%
82%
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Oper. Temperature
Storage Temperature
Cooling
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
SB08
I s o l a t e d a n d R e gulated 8 WATT Modular DC/DC Converters
series
MECHANICAL DIMENSIONS
ALL DIMENSIONS IN mm
PIN PITCH TOLERANCE +/- 0.35mm
Pin #
2
3
9
10
11
14
15
16
22
23
Single Outputs
-Vin
-Vin
NC
NC
NC
+ Output
NC
- Output
+Vin
+Vin
Dual Outputs
-Vin
-Vin
Common
NC
- Output
+ Output
NC
Common
+Vin
+Vin
OUTPUT DERATING CURVE
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181