CONVENTIONAL LED LAMPS Standard Type φ2.0 Cylinder Type LED Lamps SLC-22 Series Yellow Green Emitting Surface Dimension (mm) Shape Cylinder Type GaP Orange Red GaAsP on GaP 563nm 585nm 610nm 650nm SLC-22MG SLC-22YY SLC-22DU SLC-22VR φ2.0 3.0±0.3 ■ External Dimensions(Unit:mm) Peak Forward Reverse Operating Stotage forward current voltage temperature temperature current IF VR Topr Tstg IFP (mW) (mA) (V) (°C) (°C) (mA) Power Yellow SLC-22DU Orange SLC-22VR Red 75 25 60 20 60 3 -25 to +85 2.6 (5.0) Green SLC-22YY -30 to +100 0.5 SLC-22MG φ3.8±0.3 φ3.4 φ2.0 1.0Max. 4−0.6 ■ Electrical Optical Characteristics(Ta=25℃) Part No. Resin Color Forward voltage VF Typ. (V) SLC-22MG SLC-22YY SLC-22DU SLC-22VR IF (mA) Reverse current IR Max. (µA) VR (V) Typ. (nm) Typ. (nm) 10 10 2.0 3 585 610 □0.5 Brightness IV (2.5) IF (mA) 563 2.1 Colored Diffused Light wavelength Peak Half-wave λp ∆λ Min. Typ. IF ( mcd) (mcd) (mA) 0.9 40 2.5±1.0 *IFP measured under duty ≦1/ 5,pulse width ≦1ms. 10 1.6 0.9 2.5 CATHODE Tolerance:±0.2 ■ Directivity 2.5 0.56 24.0Min. Part No. Emitting dissipation color PD 5.5±0.3 ■ Absolute Maximum Ratings(Ta=25℃) 10 0° 650 30° 30° 60° 60° 90° 100 50 0 50 90° 100 Relative Luminous Intensity (%) (TYP.) ■ Recommemded Pad Layout ■ Packaging Spacifications(Unit:mm) Packaging Bulk(3F):2000pcs/Box 1.0 ±0.1 2.0 2.5 70 170 100 (Unit:mm) CONVENTIONAL LED LAMPS ■ Electrical Characteristic Curves Relative Luminous Intensity - Case Temperature Forward Current - Forward Voltage SLC-22MG 20 SLC-22DU 10 SLC-22VR 5.0 2.0 1.0 0.5 0.2 0.1 1.0 SLC-22MG 1.4 SLC-22YY Ta=25℃ 1.5 2.0 2.5 RELATIVE LUMINOUS INTENSITY FORWARD CURRENT : IF (mA) 50 SLC-22DU 1.2 SLC-22VR 1.0 0.8 0.6 0.4 −20 3.0 SLC-22YY FORWARD VOLTAGE : VF (V) 0 20 40 60 80 CASE TEMPERATURE(℃) Ratio of Maximum Tolerable Peak Current - Pulse Duration Relative Luminous Intensity - Forward Current SLC-22MG SLC-22MG 0.1 0.1 1 10 1 MAXIMUM FORWARD CURRENT : IF Max. (mA) SLC-22MG SLC-22YY SLC-22DU SLC-22VR 40 50 60 70 80 90 30 AMBIENT TEMPERATURE : Ta (℃) 10 100 100Hz 200Hz 1kHz 2kHz 500Hz 1000 PULSE DURATION : Tw (usec) Derating 10 2.4 1 FORWARD CURRENT : IF (mA) 20 3 10kHz 5kHz SLC-22VR 20kHz SLC-22DU SLC-22VR 100 30 SLC-22YY SLC-22DU 1 0 20 10 SLC-22YY 50kHz Ta=25℃ IFP Max/IF Max RELATIVE LUMINOUS INTENSITY 10 10000 Appendix Notes No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and operation. Please pay careful attention to the peripheral conditions when designing circuits and deciding upon circuit constants in the set. Any data, including, but not limited to application circuit diagrams information, described herein are intended only as illustrations of such devices and not as the specifications for such devices. ROHM CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any third party's intellectual property rights or other proprietary rights, and further, assumes no liability of whatsoever nature in the event of any such infringement, or arising from or connected with or related to the use of such devices. Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. The products listed in this document are designed to be used with ordinary electronic equipment or devices (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger human life (such as medical instruments, transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other safety devices), please be sure to consult with our sales representative in advance. About Export Control Order in Japan Products described herein are the objects of controlled goods in Annex 1 (Item 16) of Export Trade Control Order in Japan. In case of export from Japan, please confirm if it applies to "objective" criteria or an "informed" (by MITI clause) on the basis of "catch all controls for Non-Proliferation of Weapons of Mass Destruction. Appendix1-Rev1.1